Supply And Fixing Of Different Electric And Cables Accessories Near Maheshwari Samaj Dharmshala, Nathdwara. , Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point ( A ) , ( B ) , ( C ) , ( D ) , ( E ) , ( F ) , ( G ) , ( H ) As Below:- ( A ) Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided ( B ) Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam / Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness , Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment / Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. [ C ) Interconnection Between Bus Bar And Switchgears / Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires ( Up To 63 Amp ) And By Solid Bus Bar ( >63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) ( D ) Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. ( E ) All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ ( No Wire Splitting Or Tee Connections ) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. ( F ) Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) ( G ) Tests: The Insulation Resistance ( With 1000 V Megger ) And High Voltage Power Frequency Test ( By Applying A Voltage Of 2.5Kv For One Minute ) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. ( H ) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only ( Cpri Test Certificates To Be Submitted ) All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Supplying And Fixing Of Aluminium ( Iec 60105 Iso 209-1, 2 ) / Copper ( Iec 60028 ) Bus Bar By Means Of Smc / Dmc Type Insulator With Standard Short Circuit Withstand Capacity , High Tensile Nuts And Bolts Spring Washers In Existing Panel Including Bending , Cutting In Required Shape And Size And Colour Coding With Heat Shrinkable Pvc Sleeves. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Electrolytic Grade Aluminium Bus Bar 6010 Grade , Providing & Fixing Of Is: 13875 & Iec :61326 Confirming Led Digital Type ( Up To 500 ) V Range Volt Meter / Direct- Ammeter / Ct Oertated Ammeter / Frequency Meter / Kwh Meter / Multi Function Meter / Power Analyzer Of Class 1 Accuracy As Per Is : 1248 Of Size 96Mm X 96 Mm Including Making Connection By Pvc Insulated Copper Conductor With Pvc Sleeves / Channel Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Three Phase Ammeter With Inbuilt Selector Switch , Providing & Fixing Of Bis Approved Current Transformer As Per Pwd Specification For Electrical Works , Isi Marked As Per Is 2705-1992 / Conforming To Iec 60044-1, With Secondary Terminal Of Ct Shall Be Brought Out Suitable To A Terminal Block Which Shall Be Easier Accessible For Testing And Terminal Connection , With All Necessary Support In Existing Panel Including Connection Etc. As Required Current Transformer Ring Type Tape Wound / Resin Cast Wound As Per Is 16227 With, Accuracy Cl, Ct Ratio And Burden As Specified. Isf<=5, Cu Cross Section Of Secondary Wire 1.5Sqmm ( Minimum ) , Including All Necessary Support In Existing Panel Including Connection Etc. As Required . All As Per Pre Approved By Engineer In Charge.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr Resin Cast Wound Type Ct C T Class 1, Ratio 200 / 5 To 300 / 5, Burden 10 Va , Providing & Fixing Of Ip 51 ( Upto 500 ) V Range Volt Meter On Existing Panel As Per Pwd Specification For Electrical Works, Making Connection By Pvc Insulated Copper Conductor With Pvc Sleeves / Channel Etc. Meter Shall Give True Rms Measurments, Acc. Ci 1.0 Or Better , With Field Programmable Primary & Sec. Values Pt ( Vt ) Primary Upto 2000 Kv. Field-Programmable High And Low Threshold Values, Meter Shall Compliance Of Is 13875 & Iec 61236. As Required. Oem Must Have Bis Certificate And & Shall Have Submit Nabl / Cpri / Erda Lab Test Reports Before Execution &All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Digital , Providing & Fixing Of 110 / 220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass ( Tin Plated ) , Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Red / Yellow / Green Colour , Blue / White Colour , Providing & Fixing Of Electrical Insulating Rubber Matts As Per Pwd Specification For Electrical Works, Isi Marked Confirming To Is: 15652 / 2006 With One Side Anti Skid Abberation Marks And Pasting The Mat With Synthetic Rubber Adhesive As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 3.3 Kv, Class A 2 Mm Thick With Proof Voltage 10 Kv Ac ( Rms ) And Break Down Voltage 30 Kv Ac ( Rms ) , Sitc Of Ip 40 4 Pole Current Limiting Moulded Case Circuit Breaker ( Mccb ) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440 / 415 V, 50 Hz; O / L & S / C And Inst. Protection Setting , True Rms Sensing. As Per Pwd Specification For Electrical Works, Conforming To Is / Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Common Fault Led Indication, Thermal Memory, Release Trip Shall Confirm To Emc / Emi Compatability, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push ( Test ) To Trip, Trip Time Less Then 10 Ms Under S / C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 800 V, Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections With Lugs & Spreaders, Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 4 Pole Mccb Withwith Microprocessor Based Release 400 Amp , 50 Ka, Adjustable O / L & Adjustable S / C Setting, Ics = 100 % Icu , Providing & Fixing Of 240 / 415 V Isolator Isi Marked Is:13947- Iii / Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Four Pole Isolator 100 A Rating , Supply & Fixing Of Gi Pipes Confirming To Is : 1239 P - 1 ( 2004 ) With Flanges Duly Screwed & Welded Including Rubber Washer, Nuts & Bolts Of 8Mm Dia Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . B Class 50 Mm Dia , P / Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To Is:694 With Flexible Copper Conductor Including Making Connection Etc. As Required 10.0 Sq.Mm 3 Core Flat , Providing & Fixing Of Single Stage, Water Cooled, High Speed ( 2880 Rpm ) , Horizontal, Centrifugal, Openwell Submersible Pumps Set Pre Filled With Coolent Water And Fitted With Mechanical Seal - T / C Vs T / C, Thrust Bearing Shall Be Of Carbon + S.S.The Stator Body Of Single Phase Pump Shall Be Of Ss And Rest Of All Shall Be Of Cast Iron. All Casting Parts Should Be Cathod Electro Deposition ( Ced ) Coated And Other Construction Material Should Be Confirming To Is : 14220: 2018 . The Overall Performance Of Pump Shall Confirm To Bee Energy Efficiency Level Of 3 Star. Valid Bee Certificate From Oem Must Be Submitted For The Same. Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011, Including Making Connection Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 2.0 Hp, 1-Ø, ( 12 -25 ) Mtr, ( 350 - 115 ) Lpm , 5.0 Hp, 3-Ø, ( 14 -28 ) Mtr, ( 995-500 ) Lpm , Supply Installation Testing & Commissioning Of Iso Certified Company Made Dol / Star-Delta Starter Panel Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . For Three Phase Submersible / Mono Block Pump 3.0 Hp To 10.0 Hp ( Star / Delta Starter ) , Providing & Fixing In Position Frame Made Out Of M.S. Angle ( Riveted Or Welded ) As Per Is: 2062-2011 Finished With Two Coats Of Red Oxide And Two Coats Of Enamel Paint Including Cutting, Welding, Holes Etc. Of Following Sizes As Required. All Drawing As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 50Mm X 50Mm X6mm , Providing & Fixing Of Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . One Day & Week Reserve ( Mechanical Type ) , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc / Ms Conduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Bsr. 1 X 6.0 Sq.Mm , Providing & Fixing Of 240 / 415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-Iii / Conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Four Pole Isolator 63 A Rating , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Single Pole Mcb 6 A To 32 A Rating , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathedarmoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testingprocedures. ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. Armoured Cable 300 Sqmm 3.5 Core , 35 Sq. Mm 3.5 Core , 25 Sqmm 4 Core , 16 Sq.Mm 4 Core , 10 Sq.Mm 4 Core , 6 Sq.Mm 4 Core , 6 Sq Mm 2 Core , Supplying And Making One End Termination With Heavy Duty Brass Compression Gland ( As Per Is 12943- 1990 ) Sibg Type, Heavy Duty Aluminium Lugs ( As Per Is 8309 -1993 & Is 8337-1976 ) Duly Crimped With Crimping Tool, Pvc Tape As Per Pwd Specification For Electrical Works Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Of Size 3.5 X 70 Sq. Mm , Of Size 3.5 X 35 Sq. Mm , Of Size 4 X 10.0 Sq.Mm , Of Size 4 X 6.0 Sq.Mm , Of Size 4 X 16 Sqmm , Supplying And Making End Termination With Heavy Aluminium Lugs Pin / Ring Type ( As Per Is 8309 -1993 & Is 8337-1976 ) Duly Crimped With Crimping Tool, Pvc Tape As Per Pwd Specification For Electrical Works Etc Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Size 16.0 Sq Mm , Size 25.0 Sq Mm , Size 35.0 Sq Mm , Size 70.0 Sq Mm , Size 10.0 Sq Mm , Size 6.0 Sq Mm , Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls, Cc Road And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 50 Metres As Directed By Engineer. Cement Concrete Grade M-15 And Above And Pcc Blocks , Providing And Laying Of Double Wall Corrugated Pipe Confirming To Is :14930 P -1 & 2 With Hdpe Coupler At 1 Mtr. Depth Below The Ground For Laying Cable Including Making The Trench And Back Filling, Compaction Of Earth As Required ( Excavation Of Earth To Be Paid Extra As Required. ) Of Following Outer Dia. / Inner Dia As Per Is:4984:1994 All As Per Pre Approved By Engineer In Charge For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 55 / 50 Mm , 90 / 76 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc / Msconduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 2 X 2.5 Sq.Mm , 2 X 1.5 Sq Mm , Earth Work In Excavation For Roadway, Including Trimming Bottom And Side Slopes In Accordance With Requirement Of Line, Grades And Cross Sections, Including Disposal Of Surplus Material With All Lift And Lead Upto 1000 Metre As Per Mort&H Specification Clause 301. In Ordinary Rock , Earth Work In Excavation For Roadway, Including Trimming Bottom And Side Slopes In Accordance With Requirement Of Line, Grades And Cross Sections, Including Disposal Of Surplus Material With All Lift And Lead Upto 1000 Metre As Per Mort&H Specification Clause 301. In Hard Rocks ( Blasting Prohibited ) , Carriage Of Materials By Mechanical Transport Including Loading, Unloading And Stacking : 3 Km , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinthlevel 1:4:8 ( 1 Cement : 4 Fine / Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) . : , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc. Upto Two Stories, Excluding The Cost Of Centring, Shuttering And Finishing : 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Single Pole Mcb 0.5 A To 2 A Rating , Providing & Fixing Of Iso Certified Company Made 240 / 415 V Porcelain Kitkat Fuse ( / Hbc Type ) As Per Pwd Specification For Electrical Works Conforming To Is:2086, 1983 On Existing Board / Sheet Including Making Connections With Lugs, Testing Etc. As Required . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 63 A , 415 V , Providing & Fixing Of Ac Operated Heavy Duty 230 / 440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is / Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 4 Pole Power Contactors With Following Ac 3 Rating 63 Amp , S&F Following Sizes ( Dia. ) Of Isi Marked Medium Duty Pvc Conduit Along With Accessories In Surface / Recessed Using Saddles, Clamps, Fastener As Required Including Cutting The Wall And Making Good The Same As Required. 25 Mm , S&F Following Sizes ( Dia. ) Of Isi Marked Medium Duty Pvc Conduit Along With Accessories In Surface / Recessed Using Saddles, Clamps, Fastener As Required Including Cutting The Wall And Making Good The Same As Required. 40 Mm , Sitc Of Quick Make And Quick Break 4 Pole Current Limiting Mccb Having Following Current Rating, Short Circuit Breaking Capacity At 440 / 415 V, 50 Hz; O / L & S / C Settings And Conforming To Is 13947-2 / Iec 60947- 2 With Front Face And Centralised Adjustable, Line Load Interchangeability, Having Positive Isolation Capability, Provision For Uvr , Shunt Trip , Earth Fault Trip, Push ( Test ) To Trip , Including Making Connections With Lugs / Spreaders Etc. As Required With Thermal Magnetic Release Up To 100 Amp , 16 / 25 Ka, Adjustable O / L & Fixed S / C Setting , P & F In Position Frame Made Out Of M.S. Angle ( Riveted Or Welded ) Finished With Two Coats Of Red Oxide And Enamel Paint Of Following Sizes As Required. 25Mm X 25Mm X 5Mm , Sitc Of Chemical Gel Earthing System Of Dual Pipe Technology Made Of With B Class G I Pipe As Per Is 1239 ( Part-1 ) :2004 Of Medium Duty Of Following Sizes As Per Points Mentioned ( A ) , ( B ) , [ C ) , ( D ) , ( E ) Below :- ( A ) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri / Erda Tested With Rms Capacity Of Minimum 35- 40 Ka For Withstanding 1 Second . ( B ) To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043- 1987, Ieee 80-2013 ( Clause 14.5D ) , Ieee 837 & Ier 1956 With Latest Amendemnts ( C ) Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. ( D ) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. ( E ) Self Certificate For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . With Pipe In Pipe Technology ( Outer Pipe Dia. / Inner Pipe Dia. ) Minimum 100 Mm Dia Borewell Gi Pipe 2000 Mm Long, 80 / 50 Mm, Terminal 50Mm X 6 Mm Gi Strip , Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass ( For Cu Strip ) / Gi ( For Gi Strip ) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 25Mm X 3Mm Alum. Strip , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection With Gi / Cu Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ip54 On Front Microprocessor Based Three Phase Sensing Power Factor Correction Relay , Iec / En 61000-6- ( 2&4 ) Having 3 Ct Sensing, Sensitivity Up To 50 Milli Amp Secondary Current , Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Communication Interface With Rs 485, Indication Ofswitching On Units, Auto / Manual Status, And Shall Have Over Load Protection, No Volt Release , Having Multi Parameter Like Kw, Kva, Kvar, Vthd, Ithd, Metering Facility As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr 12 To 14 Stage , Providing & Fixing Of Self Healing Ip20 Mpp Type Shunt Capacitor ( Banks ) As Per Pwd Specification For Electrical Works, Isi Marked Is:13340-41 / Conforming To Iec :831-1&2 Or Iec : 60831-1& 2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.35 Watt Per Kvar. Min Over Current Capacity 1.8 Times Rated Current & Peak Inrush Current Min. 250 Times Of Rated Current, Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr Heavy Duty Three Phase 525 V, 50 Hz Cylindrical Capacitor ( Bank )

Tender Notice

37172712

Department Of Local Bodies

Indian


Rajasthan

April 18, 2023

Key Value

32.67 Lakhs

32.67 Lakhs

32.67 Lakhs

To Download Tender Document Click on the below link

Supply And Fixing Of Different Electric And Cables Accessories Near Maheshwari Samaj Dharmshala, Nathdwara. , Sitc Of Ip-42 And General Construction Confirming To Is:8623 : 1993, Wall / Free Standing Floor Mounted Dust And Vermin Proof Compartmentalised Cubical Panel As Specifications And Other Parameters Required As Per Point ( A ) , ( B ) , ( C ) , ( D ) , ( E ) , ( F ) , ( G ) , ( H ) As Below:- ( A ) Thickness Of Crca Sheet Shall Be 2.0 Mm, Cable Alley Compartments Having Concealed Hinged Type Doors With Key Type Lock With / Without Detachable Extension Type Structure. Removable 3 Mm. Thick Sheet Steel Gland Plates With Appropriate Size Of Knockouts For Cables Shall Be Provided ( B ) Complete Panel Shall Undergo A Process Of Degreasing, Water Rinsing, Activation, Derusting, Pickling In Acid Bath, Phosphatising & Shall Be Subjected To Nine Tank Process And Then Powder Coated With Approved Shade Of Minimum 70 Microns On Both Side Of Panel. The Panel Having Pe Foam / Neoprene Rubber Gasket Of Not Less Than 3Mm Thickness , Required Hardware , Concealed Hinged Door With Key Type Locking Arrangement For Equipment / Switchgear Earthed With 2.5 Sq.Mm Braided Copper Wire. [ C ) Interconnection Between Bus Bar And Switchgears / Cable Shall Be Rigidly Supported And Made Out By Flexible Copper Wires ( Up To 63 Amp ) And By Solid Bus Bar ( >63 Amp ) . Control Wiring Will Be Carried Out With 1.5 Sq.Mm, Earth Wire With 2.5 Sq.Mm And Ct With 2.5 Sq.Mm Flexible Copper Wire Only. All Joints / Interconnections Of Copper Bus Bar Shall Be Dully Tinned . Clearance Between Main Bus Bar And Risers / Metal Parts Shall Be At Least 10 Mm Additional To Width Of Bus Bar Bus Bar Is Insulated By Heat Shrinkable Sleeves . Earth And Neutral Bus Bar Shall Be Half Of The Size Of Phase Bus Bar. ( Cost Of Bus Bar / Flexible Wire For Interconnection Between Main Busbar And Switchgear Is To Be Paid Extra ) ( D ) Wiring Between Components Within Switchgear And Incoming / Outgoing Cable Shall Be Done Through The Terminal Block Only. Direct Connection Shall Not Be Permitted. Each Terminal Block Shall Be One Piece Moulded, Barrier Type, 650 Volt Grade, Complete With Washers, Heads, Studs With Two Nuts And Identification Strips And Shall Have Adequate Continuous Current Rating. For Tap-Offs, Adjacent Terminals With Shorting Strips Shall Be Used. 10% Spare Terminal Blocks Shall Be Provided. Wire Identification On Marking Strip Shall Correspond To The Designation Of The Wiring Diagrams. All Wire Terminals On The Equipment Shall Also Be Marked With Designation Corresponding To Those Of The Wiring Diagram. ( E ) All Wiring Shall Be Enclosed In Plastic Channels And Neatly Bunched And Closed In Metering Chamber, Wiring Between Terminals Of Various Devices Shall Be ‘Point To Point’ ( No Wire Splitting Or Tee Connections ) With Wires Neatly Trucked Along The Back Of The Panels, Adequately Supported To Prevent Sagging. ( F ) Floor Mounted Panel Shall Be Mounted On Base Frame Of Ismc Channel Size 100 X 50 X 5 Mm ( To Be Paid Extra ) ( G ) Tests: The Insulation Resistance ( With 1000 V Megger ) And High Voltage Power Frequency Test ( By Applying A Voltage Of 2.5Kv For One Minute ) Shall Be Measured Between Phases, Between Phase And Neutral And Between Phase And Earth. Both Before And After High Voltage Power Frequency Test. The Insulation Resistance Shall Not Be Less Than Three Megaohm. Ct Secondary Current Injection Test Shall Also Be Carried Out. ( H ) Only Outer Surface Area On All Sides Shall Be Measured & Panel To Be Fabricated Only From Cpri Approved Fabricator Only ( Cpri Test Certificates To Be Submitted ) All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . , Supplying And Fixing Of Aluminium ( Iec 60105 Iso 209-1, 2 ) / Copper ( Iec 60028 ) Bus Bar By Means Of Smc / Dmc Type Insulator With Standard Short Circuit Withstand Capacity , High Tensile Nuts And Bolts Spring Washers In Existing Panel Including Bending , Cutting In Required Shape And Size And Colour Coding With Heat Shrinkable Pvc Sleeves. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Electrolytic Grade Aluminium Bus Bar 6010 Grade , Providing & Fixing Of Is: 13875 & Iec :61326 Confirming Led Digital Type ( Up To 500 ) V Range Volt Meter / Direct- Ammeter / Ct Oertated Ammeter / Frequency Meter / Kwh Meter / Multi Function Meter / Power Analyzer Of Class 1 Accuracy As Per Is : 1248 Of Size 96Mm X 96 Mm Including Making Connection By Pvc Insulated Copper Conductor With Pvc Sleeves / Channel Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Three Phase Ammeter With Inbuilt Selector Switch , Providing & Fixing Of Bis Approved Current Transformer As Per Pwd Specification For Electrical Works , Isi Marked As Per Is 2705-1992 / Conforming To Iec 60044-1, With Secondary Terminal Of Ct Shall Be Brought Out Suitable To A Terminal Block Which Shall Be Easier Accessible For Testing And Terminal Connection , With All Necessary Support In Existing Panel Including Connection Etc. As Required Current Transformer Ring Type Tape Wound / Resin Cast Wound As Per Is 16227 With, Accuracy Cl, Ct Ratio And Burden As Specified. Isf<=5, Cu Cross Section Of Secondary Wire 1.5Sqmm ( Minimum ) , Including All Necessary Support In Existing Panel Including Connection Etc. As Required . All As Per Pre Approved By Engineer In Charge.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr Resin Cast Wound Type Ct C T Class 1, Ratio 200 / 5 To 300 / 5, Burden 10 Va , Providing & Fixing Of Ip 51 ( Upto 500 ) V Range Volt Meter On Existing Panel As Per Pwd Specification For Electrical Works, Making Connection By Pvc Insulated Copper Conductor With Pvc Sleeves / Channel Etc. Meter Shall Give True Rms Measurments, Acc. Ci 1.0 Or Better , With Field Programmable Primary & Sec. Values Pt ( Vt ) Primary Upto 2000 Kv. Field-Programmable High And Low Threshold Values, Meter Shall Compliance Of Is 13875 & Iec 61236. As Required. Oem Must Have Bis Certificate And & Shall Have Submit Nabl / Cpri / Erda Lab Test Reports Before Execution &All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Digital , Providing & Fixing Of 110 / 220 V, Unibody Led Indicating Lamp Iec 60947 With Integral Circuit, Ip 65 Above Panel & Ip 20 Terminal Block, Approx. Body Dia For Panel Not Less Then 20 Mm, Length Min. 50Mm, Front Led Cover Dia Min. 29 Mm, Contact Material Phospher Bronze For Led, Pcb Contacts Shall Be Of Brass ( Tin Plated ) , Impulse Dielectric Tested For 2.5 Kv, Rated Insulation Resistance Shall Be 100 M Ohm At 500Vdc Including Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Red / Yellow / Green Colour , Blue / White Colour , Providing & Fixing Of Electrical Insulating Rubber Matts As Per Pwd Specification For Electrical Works, Isi Marked Confirming To Is: 15652 / 2006 With One Side Anti Skid Abberation Marks And Pasting The Mat With Synthetic Rubber Adhesive As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 3.3 Kv, Class A 2 Mm Thick With Proof Voltage 10 Kv Ac ( Rms ) And Break Down Voltage 30 Kv Ac ( Rms ) , Sitc Of Ip 40 4 Pole Current Limiting Moulded Case Circuit Breaker ( Mccb ) Made Of Flame Retardent & Heat Resistant Material Having Following Current Rating, Short Circuit Breaking Capacity At 440 / 415 V, 50 Hz; O / L & S / C And Inst. Protection Setting , True Rms Sensing. As Per Pwd Specification For Electrical Works, Conforming To Is / Iec 60947 P -2 :2003 With Front Face And Centralised Adjustable, Common Fault Led Indication, Thermal Memory, Release Trip Shall Confirm To Emc / Emi Compatability, Trip Free Mechanisum, True Contact Position Indicator, Line Load Interchangeability, Designed For Both Horizontal & Vertical Mounting Without Any Adverse Effect On Electrical Performance, Suitable For Operation Upto 55 Degree And Without Derating Upto 40 Degree, Pollution Degree 3, Having Positive Isolation Capability, Push ( Test ) To Trip, Trip Time Less Then 10 Ms Under S / C Condition, Breaking Capacity Ics = 100% Icu. U Imp =8 Kv, Rated Insulation Voltage 800 V, Provision For Uvr , Shunt Trip , Earth Fault Trip, Door Interlock, Pad Lock & Rotary Handle , Including Making Connections With Lugs & Spreaders, Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Certificate Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 4 Pole Mccb Withwith Microprocessor Based Release 400 Amp , 50 Ka, Adjustable O / L & Adjustable S / C Setting, Ics = 100 % Icu , Providing & Fixing Of 240 / 415 V Isolator Isi Marked Is:13947- Iii / Conforming To Iec 60947-3, Suitable For Ac22a Utilization Category, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. Ip 20 Contact Protection And Fitted In Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Type Test Reports & All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr Four Pole Isolator 100 A Rating , Supply & Fixing Of Gi Pipes Confirming To Is : 1239 P - 1 ( 2004 ) With Flanges Duly Screwed & Welded Including Rubber Washer, Nuts & Bolts Of 8Mm Dia Complete In All Respect.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . B Class 50 Mm Dia , P / Laying Isi Marked P.V.C. Insulated Submersible Cable Confirming To Is:694 With Flexible Copper Conductor Including Making Connection Etc. As Required 10.0 Sq.Mm 3 Core Flat , Providing & Fixing Of Single Stage, Water Cooled, High Speed ( 2880 Rpm ) , Horizontal, Centrifugal, Openwell Submersible Pumps Set Pre Filled With Coolent Water And Fitted With Mechanical Seal - T / C Vs T / C, Thrust Bearing Shall Be Of Carbon + S.S.The Stator Body Of Single Phase Pump Shall Be Of Ss And Rest Of All Shall Be Of Cast Iron. All Casting Parts Should Be Cathod Electro Deposition ( Ced ) Coated And Other Construction Material Should Be Confirming To Is : 14220: 2018 . The Overall Performance Of Pump Shall Confirm To Bee Energy Efficiency Level Of 3 Star. Valid Bee Certificate From Oem Must Be Submitted For The Same. Motor Should Be Ie2 Class As Per Iec 60034-2-1: 2007, Iec 60034-30: 2008, & Is12615:2011, Including Making Connection Etc As Required Complete In All Respect. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 2.0 Hp, 1-Ø, ( 12 -25 ) Mtr, ( 350 - 115 ) Lpm , 5.0 Hp, 3-Ø, ( 14 -28 ) Mtr, ( 995-500 ) Lpm , Supply Installation Testing & Commissioning Of Iso Certified Company Made Dol / Star-Delta Starter Panel Made Out From 1.6 Mm Thick Powder Coated Crca Sheet, Enclosure Comprising Of Over Load Protection Relay, Short Circuit & Single Phasing Protection, Illuminated On / Off Push Buttons, Ammeter, Voltmeter, Indicating Lamps Etc. Suitable For Following Rating Motors Complete In All Respect. Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . For Three Phase Submersible / Mono Block Pump 3.0 Hp To 10.0 Hp ( Star / Delta Starter ) , Providing & Fixing In Position Frame Made Out Of M.S. Angle ( Riveted Or Welded ) As Per Is: 2062-2011 Finished With Two Coats Of Red Oxide And Two Coats Of Enamel Paint Including Cutting, Welding, Holes Etc. Of Following Sizes As Required. All Drawing As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 50Mm X 50Mm X6mm , Providing & Fixing Of Digital Time Switch Having Following Day / Week Programme And Minimum 100 Hours Reserve And Ac1 Rating Of 16-20 Amperes Including Making Connection, Programming Conforming To Iec 60730-1 And 60730-2-7 Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . One Day & Week Reserve ( Mechanical Type ) , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc / Ms Conduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Bsr. 1 X 6.0 Sq.Mm , Providing & Fixing Of 240 / 415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-Iii / Conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4Kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35Sq.Mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Four Pole Isolator 63 A Rating , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Single Pole Mcb 6 A To 32 A Rating , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathedarmoured Aluminium Cable Of 1.1 Kv Grade As Per Pwd Specification For Electrical Works In Existing Rcc / Hume / Stoneware / Pvc Pipe / Open Duct / Cable Trench With Filling Of Excavated Earth In Trench , On Existing Cable Trays Or On Surface Etc. Including Making Necessary Connection, Testing Etc. As Required Of Size And As Per Points ( A ) , ( B ) , ( C ) , Mentioned Below:- ( A ) Material :- H4- Grade Aluminium Conductor Of Purity >99.6 % & As Per Is:1554 P-I / Is :7098 P – I ( B ) Conductor Shall Have Electrolytic Aluminium Confirming To Is 8130, Is 3975-1999 For Armouring Of Cables In Armoured Cable Items , Is 5831 For Sheath, Is 10810 ( Part 0 To 64 ) For Testingprocedures. ( C ) Oem Must Have Iso 9001 & 14001 Certifications For Quality Assuarance & Its Own In House Nabl Lab Setup For All Testing Facilities For Cables . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All Above As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr. Armoured Cable 300 Sqmm 3.5 Core , 35 Sq. Mm 3.5 Core , 25 Sqmm 4 Core , 16 Sq.Mm 4 Core , 10 Sq.Mm 4 Core , 6 Sq.Mm 4 Core , 6 Sq Mm 2 Core , Supplying And Making One End Termination With Heavy Duty Brass Compression Gland ( As Per Is 12943- 1990 ) Sibg Type, Heavy Duty Aluminium Lugs ( As Per Is 8309 -1993 & Is 8337-1976 ) Duly Crimped With Crimping Tool, Pvc Tape As Per Pwd Specification For Electrical Works Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Of Size 3.5 X 70 Sq. Mm , Of Size 3.5 X 35 Sq. Mm , Of Size 4 X 10.0 Sq.Mm , Of Size 4 X 6.0 Sq.Mm , Of Size 4 X 16 Sqmm , Supplying And Making End Termination With Heavy Aluminium Lugs Pin / Ring Type ( As Per Is 8309 -1993 & Is 8337-1976 ) Duly Crimped With Crimping Tool, Pvc Tape As Per Pwd Specification For Electrical Works Etc Of Following Size. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Size 16.0 Sq Mm , Size 25.0 Sq Mm , Size 35.0 Sq Mm , Size 70.0 Sq Mm , Size 10.0 Sq Mm , Size 6.0 Sq Mm , Dismantling Of Existing Structures Like Culverts, Bridges, Retaining Walls, Cc Road And Other Structure Comprising Of Masonry, Cement Concrete, Wood Work, Steel Work, Including T&P And Scaffolding Wherever Necessary, Sorting The Dismantled Material, Disposal Of Unserviceable Material And Stacking The Serviceable Material With All Lifts And Lead Of 50 Metres As Directed By Engineer. Cement Concrete Grade M-15 And Above And Pcc Blocks , Providing And Laying Of Double Wall Corrugated Pipe Confirming To Is :14930 P -1 & 2 With Hdpe Coupler At 1 Mtr. Depth Below The Ground For Laying Cable Including Making The Trench And Back Filling, Compaction Of Earth As Required ( Excavation Of Earth To Be Paid Extra As Required. ) Of Following Outer Dia. / Inner Dia As Per Is:4984:1994 All As Per Pre Approved By Engineer In Charge For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 55 / 50 Mm , 90 / 76 Mm , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked ( Is:694 ) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm ) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A Or C , Flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc / Msconduit / Casing Capping Including All As Per Pre Approved By Engineer In Charge, Making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 2 X 2.5 Sq.Mm , 2 X 1.5 Sq Mm , Earth Work In Excavation For Roadway, Including Trimming Bottom And Side Slopes In Accordance With Requirement Of Line, Grades And Cross Sections, Including Disposal Of Surplus Material With All Lift And Lead Upto 1000 Metre As Per Mort&H Specification Clause 301. In Ordinary Rock , Earth Work In Excavation For Roadway, Including Trimming Bottom And Side Slopes In Accordance With Requirement Of Line, Grades And Cross Sections, Including Disposal Of Surplus Material With All Lift And Lead Upto 1000 Metre As Per Mort&H Specification Clause 301. In Hard Rocks ( Blasting Prohibited ) , Carriage Of Materials By Mechanical Transport Including Loading, Unloading And Stacking : 3 Km , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinthlevel 1:4:8 ( 1 Cement : 4 Fine / Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) . : , Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets Etc. Upto Two Stories, Excluding The Cost Of Centring, Shuttering And Finishing : 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , Providing & Fixing Of 240 / 415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka ( B / C Tripping Characteristic As Per Type Of Load And Site Requirement ) 4Kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828 ( 1996 ) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheets, Min. Operation 20, 000 Upto 32 A Rating And 10, 000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . Single Pole Mcb 0.5 A To 2 A Rating , Providing & Fixing Of Iso Certified Company Made 240 / 415 V Porcelain Kitkat Fuse ( / Hbc Type ) As Per Pwd Specification For Electrical Works Conforming To Is:2086, 1983 On Existing Board / Sheet Including Making Connections With Lugs, Testing Etc. As Required . Appropriate Type Test Certificate / Oem Test Report Shall Be Submitted . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 63 A , 415 V , Providing & Fixing Of Ac Operated Heavy Duty 230 / 440 Volt Power Contactor As Per Pwd Specification For Electrical Works, Isi Marked Is / Iec 60947-4-1 : 2000 Having Provision Of Mechanical Interlocking, Auxilary Contacts, Din Rail Mounting Type Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 4 Pole Power Contactors With Following Ac 3 Rating 63 Amp , S&F Following Sizes ( Dia. ) Of Isi Marked Medium Duty Pvc Conduit Along With Accessories In Surface / Recessed Using Saddles, Clamps, Fastener As Required Including Cutting The Wall And Making Good The Same As Required. 25 Mm , S&F Following Sizes ( Dia. ) Of Isi Marked Medium Duty Pvc Conduit Along With Accessories In Surface / Recessed Using Saddles, Clamps, Fastener As Required Including Cutting The Wall And Making Good The Same As Required. 40 Mm , Sitc Of Quick Make And Quick Break 4 Pole Current Limiting Mccb Having Following Current Rating, Short Circuit Breaking Capacity At 440 / 415 V, 50 Hz; O / L & S / C Settings And Conforming To Is 13947-2 / Iec 60947- 2 With Front Face And Centralised Adjustable, Line Load Interchangeability, Having Positive Isolation Capability, Provision For Uvr , Shunt Trip , Earth Fault Trip, Push ( Test ) To Trip , Including Making Connections With Lugs / Spreaders Etc. As Required With Thermal Magnetic Release Up To 100 Amp , 16 / 25 Ka, Adjustable O / L & Fixed S / C Setting , P & F In Position Frame Made Out Of M.S. Angle ( Riveted Or Welded ) Finished With Two Coats Of Red Oxide And Enamel Paint Of Following Sizes As Required. 25Mm X 25Mm X 5Mm , Sitc Of Chemical Gel Earthing System Of Dual Pipe Technology Made Of With B Class G I Pipe As Per Is 1239 ( Part-1 ) :2004 Of Medium Duty Of Following Sizes As Per Points Mentioned ( A ) , ( B ) , [ C ) , ( D ) , ( E ) Below :- ( A ) Filled With Anti Corrosive Conductive Compounds With The Permanent Sealings At Both The Ends, Cpri / Erda Tested With Rms Capacity Of Minimum 35- 40 Ka For Withstanding 1 Second . ( B ) To Ensure The Moisture Content And Electrical Conductivity, 25 Kg For 2000 Mm & 50 Kgs For 3000Mm Of Resistance Lowering Earth Enhancement Material Shall Be Used As A Backfill Compound. The Compound Shall Be Tested Form Nabl Acredeated Lab For Low Resistivity ( Less Than 0.12 Ohm - Meter ) & High Conductivity In Nature With Carbon As A Major Content As Per Referance Of Is 3043- 1987, Ieee 80-2013 ( Clause 14.5D ) , Ieee 837 & Ier 1956 With Latest Amendemnts ( C ) Heavy Duty Weather Proof Poly-Propylene Earth Pit Chamber With Lockable Jam Free Lid Suitable For Safe Working Load 5000 Kg Or More Of Size Top Dia. 225 To 260 Mm, Bottom Dia 300 To 350 Mm. And Height 250 To 300 Mm. ( D ) Testing Of Earth Resistance For Value Of 5 Ohms Or Less As Required & Must Record By Engineer In Charge During Site Visit And Ensure To Enter In Measurment Book. ( E ) Self Certificate For Confirming Above Standards From Oem Is Mandatory. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . With Pipe In Pipe Technology ( Outer Pipe Dia. / Inner Pipe Dia. ) Minimum 100 Mm Dia Borewell Gi Pipe 2000 Mm Long, 80 / 50 Mm, Terminal 50Mm X 6 Mm Gi Strip , Supply & Laying Following Size Earth Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Jointing Shall Be Done By Overlapping And With 2 Set Of Brass ( For Cu Strip ) / Gi ( For Gi Strip ) Nut Bolt & Spring Washer Spaced At 50Cm Making Connection Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 25Mm X 3Mm Alum. Strip , Supply & Laying Following Size Earth Wire In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection With Gi / Cu Thimble Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr . 8 Swg G.I. ( Hot Dipped ) Wire , Providing & Fixing Of Ip54 On Front Microprocessor Based Three Phase Sensing Power Factor Correction Relay , Iec / En 61000-6- ( 2&4 ) Having 3 Ct Sensing, Sensitivity Up To 50 Milli Amp Secondary Current , Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Communication Interface With Rs 485, Indication Ofswitching On Units, Auto / Manual Status, And Shall Have Over Load Protection, No Volt Release , Having Multi Parameter Like Kw, Kva, Kvar, Vthd, Ithd, Metering Facility As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr 12 To 14 Stage , Providing & Fixing Of Self Healing Ip20 Mpp Type Shunt Capacitor ( Banks ) As Per Pwd Specification For Electrical Works, Isi Marked Is:13340-41 / Conforming To Iec :831-1&2 Or Iec : 60831-1& 2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.35 Watt Per Kvar. Min Over Current Capacity 1.8 Times Rated Current & Peak Inrush Current Min. 250 Times Of Rated Current, Including Making Connections, Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products / Work , Refer Annexure A Attached With This Bsr Heavy Duty Three Phase 525 V, 50 Hz Cylindrical Capacitor ( Bank )