Medical Health And Family Welfare - Rajasthan

40141924 tender for purchase of c arm machine in orthopedic department at government y.n. hospital kishangrh ( ajmer ) , items : , c arm machine , technical specifications for all purpose latest c arm image intensifier system the c –arm unit should allow unobstructed positioning and should have the following features. , 1. mechanical motion requirements for c arm: motorized vertical travel: 400 mm or more, pivotal rotation / swivel range: + / 12.5° or more, arc orbital movement: 1200 ( 300 to + 900 ) or better, horizontal movement should be: 200mm or better, source to image intensifier distance ( sid range ) : 960mm or better, free space between inage intensifier and x ray tube: 760mm or better, rotation of c arm: + / 180° or more, depth of c arm should be adequate to encircle ot table & bulky patient: 630mm or better, the c arm should also have foot lock facility at console to immobilize the unit. it should have mechanical locks for all the movements of c arm. , 2. x ray generator & control panel: the x ray generator should high frequency of 100khz or more with maximum 3.5kw output. x ray generator should be capable of operating between 40 kv to 110 kv. the x ray generator should have 0.1 to 3 ma range for continuous fluoroscopy. monoblock tube head having dual focus rotating anode x ray tube of focal spot 0.3mm. ( small focus ) & large focus ( 0.6mm ) should be provided. the anode heat storage capcity of tube should be 80khu or more. the boosted / high definition fluoroscopy should be 7.0 ma or better. the radiography mas should be 200mas or better. the radiography ma should be 70ma or more. x ray exposure should be initiated through the foot switch & hand held switch. the c arm system should have digital control panel. the system should have facility of image rotation, averaging, edge enhancement, image invert, image flip & image save from control panel. the system should have a facility to select kv & ma in manual / auto mode. switches for up / down movement of “c” on both side of panel. collimator control switches. ( to open / close horizontal and vertical shutte. the control panel should have the facility of display of all fluoroscopic and radiographic parameters viz. kv, ma, time and operating mode, magnification. a five minute cumulative timer with buzzer should be five minute. audible and visual indication for x ray emission. emergency stop switch for manual shut off , 3. imaging section: ( image intensifier & tv camera ) : the image intensifier should have triple field 9” / 6” / 4.5”, 23cm input diameter, 25mm output diameter with central resolution of 52lp / cm in normal mode and 10:1, 100 lines x ray grid. tv camera should be compact ccd / cmos 1k² camera of pixel ( 1024 x 1024 pixels ) or more. 02 nos medical grade monochrome high brightness, high contrast 19” lcd ( or more ) monitors with height adjustaable and foldable / 01 no. 27” or more high resolution monitor with split screen mounted on mobile trolley. the system should have facility to rotate the image continuously without exposure , 4.digital imaging processing: the c arm unit should incorporate pc based image memory with the standard features as mentioned below: new patient registration with patient details, procedure details, doctors name, date and time, display of information like patient id, patient name, patient age, operating modes, rotation, kv & ma value display, hospital name display on monitor, real time brightness and contrast adjustments for improved image quality, real time brightness and contrast adjustments for improved image quality, permanent image storage capacity of 1, 00, 000 images or more, image rotation ( + / 180 degrees ) clockwise and anti clockwise at a 1 degree step, image orientation: left / right ( horizontal flip ) and top / bottom ( vertical flip ) , negative images ( grey level invert ) , image averaging for noise reduction ( 2, 4, 6, 8, 12, and 16 ) , real time edge enhancement, manual save and auto save facility for images, reference monitor – transfer the image from live to reference screen, multiple image views on reference monitor: single, quad, 9 images, cine loop acquisition: 1, 2, 4, 8, 15, 25 frames per second, cine loop display ( play, pause and stop ) and frame by frame review, quick exploration of stored images from search patient, thumbnail view for images and cine loop, cine loop display ( play, pause and stop ) and frame by frame review on the reference monitor, image post processing filters on saved images ( sharpening, mean filter and median filter ) , edge detection facility, image zoom in, zoom out and pan, measurements & annotation facility , 5. data documentation: software should have the facility to generate the patient report, usb image export facility, dvd burning facility , 6. power requirement: power input to be 230volts + 10% ac, 50 hz fitted with 15 amp plug , 7. essential accessories: the system should be supplied with aerb approved light weight lead aprons ( 2 nos ) , inbuilt ups for power backup to workstation , note: the quoted model must have valid indian bis / usfda / european ce & aerb certificates. manufacturing fir m must have the latest iso 13485: 2016 certificatio. the unit should be offered with a 3 year warranty. company should have a well established after sales service network with a toll free service call login facility. companies should also have a local service representative or service facility to provide fastest response time in case of breakdown of the equipment , note: if any deviation please cross in above required specifications...

RAJASTHAN MEDICAL EDUCATION SOCIETY - Rajasthan

40114077 rate contract of two years for supply and installation of cath lab for medical colleges located in rajasthan multi directional c arm positioned , patient table , x ray generator , x ray tabe , dynamic flat detector system , digital image system , archival system , cross sectional imaging , etc...

Medical College - Rajasthan

38384271 tender for purchase of endovascular lab multidirectional c arm / g arm positioner, patient table, x ray generator, x ray tube, radiation protection, dynamic flat detector system, monitors....

Sms Medical College - Rajasthan

36014554 supply of cardiac cath lab on turnkey basis ( in dedicated pediatric cardiac and ctvs unit ) ( nit 244 ) multi direction c arm positioneed patient table , x ray generator , x ray tube dynamic flat detector system digital image system archival system correctional imaging , hemodynamic monitoring time and amplitude measurement , monitor display , collimator , essential accessories radiation protection i single plane cardiovascular catheterisation with digital subtraction angiography lab ns per specification 2 dedicated 3d workstation 3 dicom workstations 3 hemodynamic 4 laser printer with minimum 16 mb memory with minimum 1200 dpi 5 ecg cables six 6 pressure transducers — six 7 foot switch for fluoroscopy and acquisition — two . ceiling suspended operation lamp — one 8 9 leadglass(l2oxi00cm)—one 10 radiation shield ceiling and table mounted! suspended — one 11 high power contrast injrctor with 200 syringes — one — — radiation protective apron light weight —20 12 a front type 10 b wraparound 6 c two piece rype .4 0 d lead cap 5 hanger stands to hold 5 apron 2 wall mounted hangers 2 hold 5 aprons 2 thyroid guards 10 lead spectacles 5 13 14 15 16 17 lead lined gloves 2 18 intercom between exam room and control room. 1 19 laser network printer 1 with 1000 glossy paper ...e 20 intra aortic balloon pump (iabp) with cmc 1 21 1 abg machine wilh cmc 1 22 online ups i 23 defibrillator with extemnal pacer 2 24 act machine 1 anaesthesiaworkstation 1 with cmc 25 26 furnitures a revolving chairs height adjustable 10 b tables for console and workstation as required c modular design walls cabinets 6 d cupboard with laminate door shutters 3 e instrument trolleys 2 f patient footstep 2 g drug trolley 2 h chairs for patient waiting area three seater (chrome plated) ten in number i patient trolley with rubber foam mattress 2 changing rooms should have change iocters and dressing table 2 dustbins (plastic wlth lid) 4 site modification — tihis is rough estimate civil works 1500 sq feet electrcal work— 1500 sq feet public health (plumbing and sanitary fittings). air conditioning 20 ton interior fumnishing & furniture 1500 sq feet knee controlled and free scrub station with disinfectantl soap dispenser 1edx ray film viewer (capable or holding 3 films of 14”x17”size) 2 cabling or network (lan) connectivity for camera system, console system, work station and computers ete l fire extinguisher dry c02 abc type as required for the building safety 2 etc ...

Government Medical College - Rajasthan

32779448 cardiac lab/cath lab on trunkey basis cardiac lab/cath lab on trunkey basis , rnt medical college, udaipur , cardiac lab/cath lab on trunkey basis , taxes , gst (in amount) , camc shall be given after 03 year warranty period c arm g arm multi directional floor ceiling mounted table x ray generator x ray tube radiation protection digital imaging system ,monitors display image processing and storage digital archiving cath lab recording system dedicated hemodynamic recording system from oem original equipment manufacturer essential accessories foot switch ceiling suspended operation lamp leasd glass , radiation shield ceiling and table mounted suspended , high power contrast injector , radiation protective apron , two hanger stands , thyroid guards , suction machine radiation protection installation site modification essential site electrical work public health plumbing sanitary fitting civil work flooring painting false ceiling electrical plumbing air conditioning work furniture chair table modular cupboard instrument trolley , drug trolley chair patient troley dustbin air conditioning sensor foot controlled hand free scrub station with disinfectant soap dispenser , led x ray film viewer , cabling of network connectivity for camera system console system workstation and computer , fire extinguisher dry co2 abc type ups lead etc ...

Rabindranath Tagore Medical College - Rajasthan

32746219 supply of cardiac lab / cath lab on trunkey basis c arm g arm multi directional floor ceiling mounted table x ray generator x ray tube radiation protection digital imaging system ,monitors display image processing and storage digital archiving cath lab recording system dedicated hemodynamic recording system from oem original equipment manufacturer essential accessories foot switch ceiling suspended operation lamp leasd glass , radiation shield ceiling and table mounted suspended , high power contrast injector , radiation protective apron , two hanger stands , thyroid guards , suction machine radiation protection installation site modification essential site electrical work public health plumbing sanitary fitting civil work flooring painting false ceiling electrical plumbing air conditioning work furniture chair table modular cupboard instrument trolley , drug trolley ...

Government Medical College - Rajasthan

31956794 supply and installation of cardiac cath lab and oct machine with accessories and site modification work multi directional c arm positioing patient table , x ray generator , x ray tube dyanamic flate detector system , digial image system , archial system , cross sectional imaging heyamonic monotiroring radiation protection civil work electrical public health plumbing and sanitary fittings air conditioning interior furnishing and furniture , flooring painting false ceiling electrical plumbing work , air conditioning electrical furniture etc 15 thyroid guards 10 — 17 uead lined gloves 2 intercom between exam room and control room. 1 18 19 laser network printer 1 with 1000 glossy caner 21 defibrillator with external pacer 1 22 furnitures revolving chairs height adjustable 5 a b tables for console and workstation as required c modular design walls cabinets 6 d cupboard with laminate door shutters 3 e instrument trollevs 2 f patient foot stepp — 2 g drug trolley 2 h chairs for patient waiting area three seater (chrome plated) 5 in number i • patient trolley with rubber foam mattress 2 j changing rxoms should have change lockers and dressing table 2 k dustbins plastic with lidd 4 23 site modification this is rough estimate a civil works 800 sq feet b electriaal work 800 sq feet c public health (plumbing and sanitary fittings) d air conditioning 10 ton e interior furnishing & furniture 80o sq feet ___.____ 24 knee controlled hand free scrub station with disinfectant/ soap dispenser 25 led x ray film viewer (capable of holding 3 films of 14x17” size) 2 26 cabling of network (lan) connectivity for camera system, console system, workstation and computer etc. 1 27 fire extinguisher dry c02 abc type as required for the building safety 2 16 lead spectacles 5 20 onnhineups 1t etc ...

Medical And Health Services - Rajasthan

31596365 chc sindhari digital x ray machine large focus 500ma high frequency with table & installation work as per requirement of full functions of xray machine. provide of x ray generator, line voltage regulation, ht transformer, ht cable, focal spoot, bucky device....

Medical And Health Services - Rajasthan

31594245 provide of sonography machine equipment prob, gps, monitor, thermal printer, hard disc, ram, x ray machine equipment x ray generator, output, ratig radiography, kvp range, radiographic timer, control, oveload, tube unit, collimator hv cable, tube stand, table, power supply, required lab equipment, auto processor, elisa micro plate reader, fully automated bio chemistry analyser, five part cbc machine....

Government Medical College - Rajasthan

30992771 iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv , radiodiagnosis department , iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv , taxes , gst ( in amount ) , camc shall be given after 03 year warranty period for 07 year @ 4% of the net rate ( excluding gst as applicable ) and yearly escalation of 5% on last years camc price will be considered....

Government Medical College - Rajasthan

30487773 supply of iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv...

Government Medical College - Rajasthan

29399176 iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv , radiodiagnosis dept. , iitv with 65 kw or more x ray generators system equivalent to 800 ma and above x ray machine with iitv , taxes , gst (in amount) , camc shall be given after 03 year warranty period for 07 year @ 4% of the net rate (excluding gst as applicable) and yearly escalation of 5% on last years camc price will be considered....

Medical College - Rajasthan

28964486 cardiac cath lab on turnkey basis cardiac cath lab on turnkey basis , single plane cardiovascular catheterisation with digital substraction angiography lab multi directional c arm positioned , patient table , x ray generator , x ray tube , dynamic flat detector system , digital image system , archival system , cross sectional imaging , time and amplitude measurement , essential accessories , radiation protection , etc ...

Sms Medical College - Rajasthan

28960608 supply of cardiac cath lab on turnkey basis ( nit 61 ) single plane cardiovascular catheterisation with digital substraction angiography lab multi directional c arm positioned , patient table , x ray generator , x ray tube , dynamic flat detector system , digital image system , archival system , cross sectional imaging , time and amplitude measurement , essential accessories , radiation protection , etc ...

Medical And Health Services - Rajasthan

28353905 supply of x ray machine with cr system and other hospital equipments. multi parameter patient monitor, oxygen flow meter with humidifier, attendant bench full box with cushain sheet gage pipe 18 gage, suction machine, x ray generator, x ray tube, control, hv tank, tube stand, table, vertical bucky stand, power requirement, other requirement cr system, lacer camera, acceptable film, cr workstation , cassette , suitable online ups, x ray film box...

Indian Army - Rajasthan

18019218 supply of rfp / mhj / dglp / mobile / c arm image intensifier tv system / 2018 19 for military hospital jodhpur, 1 mobile surgical c arm a full integrated mobile surgical c arm unit comprised of all the major components of the unit viz x ray, generator, x ray tube & image intensifier. the unit should have good maneuverability for easy positioning during surgey in ot. it should be a well balanced system for quick positioning. it should be of compact design and must have the following system configuration : 2 a . c arm unit : fully integrated and counter balanced c arm with individual locking of all movement. all c arm cables should be concealed in the body for maintaining proper hygienic and sterility in the ot room. 3 b. x ray high voltage generator : • inverter generator with inverter frequency of not less than 40 khz. • maximum power output 2 kw and above. • fluoroscopy / radiographic kv range : 40 110 kv or more • fluoroscopy ma range 0.2 4 ma or more. • radiography ma : 20 ma or more. • radiographic mas range : 50ma 70 ma or more. ...