Rajasthan State Industrial Development And Investment Corporation Limited - Rajasthan

34186966 supply of different electrical materials at ind. area hanumangarh 1 p&f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( from 45 w onwards ) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree / / nichia / osram / philips / seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd ( i ) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark / name housing to allow traceability / authenticity till life of fixture. fixtures shall be ce complianced., high power led flood light 70 w composit 2 p&f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( from 45 w onwards ) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree / / nichia / osram / philips / seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd ( i ) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark / name housing to allow traceability / authenticity till life of fixture. fixtures shall be ce complianced., high power led flood light 80 w composit 3 p&f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( from 45 w onwards ) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree / / nichia / osram / philips / seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd ( i ) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark / name housing to allow traceability / authenticity till life of fixture. fixtures shall be ce complianced., led street light fixture 70 watt rate ( rs ) 4 p&f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( from 45 w onwards ) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree / / nichia / osram / philips / seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd ( i ) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark / name housing to allow traceability / authenticity till life of fixture. fixtures shall be ce complianced., led street light fixture 80 watt rate ( rs ) 5 p / laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size., 10.0 sq.mm, 2 core unarmoured 6 p / laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size., 10.0 sq.mm, 2 core labour rate 7 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface or recessed conduit / casing capping including making connections etc. as required., 1 x 1.5 sq.mm group 1 8 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface or recessed conduit / casing capping including making connections etc. as required., 1 x 1.5 sq.mm labour rate 9 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required, one day & week reserve ( digital type ) group 1 10 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required, one day & week reserve ( digital type ) labour rate 11 p&f 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections, testing etc. as required., single pole mcb, 6 a to 32 a rating group 1 12 p&f 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections, testing etc. as required., single pole mcb, 6 a to 32 a rating labour rate 13 p&f 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections, testing etc. as required., single pole mcb, 40 a to 63 a rating group 1 14 p&f 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections, testing etc. as required., single pole mcb, 40 a to 63 a rating labour rate 15 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating:, with sheet steel enclosure, 125 a group 1 16 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating:, with sheet steel enclosure, 125 a labour rate 17 s & f of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners etc. as required., 25 mm dia. group 1 18 s & f of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners etc. as required., 25 mm dia. labour rate...

Department Of Local Bodies - Rajasthan

34109210 supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. 6.0 sq. mm4 core , supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 10 swg g.i. ( hot dipped ) wire , supply & laying following size b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor / strip / cable in ground / surface / recess as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 50 mm dia , providing & laying of double wall corrugated pipe confirming to is : 14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling , compaction of earth as required ( excavation of earth to be paid extra as required. ) of following outer dia. / inner dia as per is:4984:1995. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 55 / 50 mm , labour charges for excavation of 30cmx75cm size trench in cc road including refilling of excavated earth, compaction of earth, making good the same complete as required . , labour charges for excavation of 30cmx75cm size trench in loose soil including refilling of excavated earth, compaction of earth, making good the same complete as required . , plate earthing as per pwd specification for electrical works as per is:3043 with hot dipped g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr .single pole mcb 06 amp rating , four pole mcb 32 amp rating , providing & fixing of ac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 pole power contactors with following ac 1 rating 32 amp. , sitc of wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as per pwd specification for electrical works, made out of crca sheet . other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) below: ( a ) thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. load bearing structure shall be of 2.0 mm thick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / without detachable extension type structure ( b ) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade the panel having pu / neoprene rubber gasket of not less than 3mm thickness , required hardware, separate detachable gland plate m.s. base channel ( min75mm ) , hinged door with locking arrangement for equipment / switchgear. ( c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 125 amp ) and by solid bus bar ( >125 amp ) . all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( d ) only outer area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator. all as per drawing pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar as per pwd specification for electrical works, by means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . electrolytic grade ( cu etp ) tin coated annealed copper bus bars iacs 100% grade , providing & fixing of 110 240 v, ac, 1 ph. , 2 w astronomical time switch with surge suppressor, memory card, sunrise / sunset selectable, software for programming including making connection, etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr .2 x 1.5 sq.mm , 1 x 4.0 sq.mm...

Urban Improvement Trust - Rajasthan

33945947 estimate for purchasing material for maintenance of road lights. nit21 / 2022 23 / item4 p.v.c. / xlpe insulated & p.v.c. sheat hed un armoured / armour ed copper cable, isolator, digital time switch, led street light, etc. ...

Department Of Local Bodies - Rajasthan

33944981 supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu supply and fixing of decorative poles in kamla nehru garden at muniicpal board mount abu , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. 6.0 sq. mm4 core , supply & laying following size earth wire in horizontal or vertical run in ground / surface / recess including riveting, soldering, saddles, making connection with gi / cu thimble etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 10 swg g.i. ( hot dipped ) wire , supply & laying following size b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor / strip / cable in ground / surface / recess as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 50 mm dia , providing & laying of double wall corrugated pipe confirming to is : 14930 p 1 & 2 with hdpe coupler at 1 mtr. depth below the ground for laying cable including making the trench and back filling , compaction of earth as required ( excavation of earth to be paid extra as required. ) of following outer dia. / inner dia as per is:4984:1995. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 55 / 50 mm , labour charges for excavation of 30cmx75cm size trench in cc road including refilling of excavated earth, compaction of earth, making good the same complete as required . , labour charges for excavation of 30cmx75cm size trench in loose soil including refilling of excavated earth, compaction of earth, making good the same complete as required . , plate earthing as per pwd specification for electrical works as per is:3043 with hot dipped g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe , including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and heavy duty weather proof poly propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000 kg or more of size top dia. 225 to 260 mm, bottom dia 300 to 350 mm. and height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke / charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load and site requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted with existing distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a rating including making connections, testing etc. as required. . oem shall have submit nabl / cpri / erda accrediated lab test reports before execution & all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . single pole mcb 06 amp rating , four pole mcb 32 amp rating , providing & fixing of ac operated heavy duty 230 / 440 volt power contactor as per pwd specification for electrical works, isi marked is / iec 60947 4 1 : 2000 having provision of mechanical interlocking, auxilary contacts, din rail mounting type including making connections, testing etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . 4 pole power contactors with following ac 1 rating 32 amp. , supplying and fixing of aluminium ( iec 60105 iso 209 1, 2 ) / copper ( iec 60028 ) bus bar as per pwd specification for electrical works, by means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . electrolytic grade ( cu etp ) tin coated annealed copper bus bars iacs 100% grade , sitc of wall / free standing floor mounted dust and vermin proof compartmentalised cubical panel as per pwd specification for electrical works, made out of crca sheet . other parameters required as per point ( a ) , ( b ) , ( c ) , ( d ) below: ( a ) thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. load bearing structure shall be of 2.0 mm thick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / without detachable extension type structure ( b ) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade the panel having pu / neoprene rubber gasket of not less than 3mm thickness , required hardware, separate detachable gland plate m.s. base channel ( min75mm ) , hinged door with locking arrangement for equipment / switchgear. ( c ) interconnection between bus bar and switchgears / cable shall be rigidly supported and made out by flexible copper wires ( up to 125 amp ) and by solid bus bar ( >125 amp ) . all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( d ) only outer area on all sides shall be measured & panel to be fabricated only from cpri approved fabricator. all as per drawing pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , providing & fixing of 110 240 v, ac, 1 ph. , 2 w astronomical time switch with surge suppressor, memory card, sunrise / sunset selectable, software for programming including making connection, etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . 2 x 1.5 sq.mm , 3 x 2.5 sq.mm , 1 x 4.0 sq.mm , providing & fixing of ik07 ip 66 protected high power led floodlight system with pressure diecast aluminium housing lm6 / adc12 material , toughened glass diffuser with suitable lenses on led to achieve various beam angles, 240 volt, 50hz, of high power led lamps . integrated driver must be potted & has a unique bis r number shall be high efficiency having efficiency more than 85 %and in compliance to bis certified and t.c. certificate. the system level luminaire efficacy >=120 lm / wt with high power leds is to be used . led driver input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety . input frequency 50hz±3%, power factor >0.95 , driver efficiency >85% , thd ( i ) <10% , driver current <1000ma shown in lm79 report. driver should be phase to phase protection of 440 v for 4 hrs. electrical connector must be provided, surge protection min >=4kv internaland 10kv external, system life of 30000 burning hours with 70% ofinitial lumens maintained, color rendering index >70 and cct 5700k±355k. driver current <1000ma shown in lm79 report. manufactures word mark / name engraved / embossing / screenprinting on die cast housing to allow traceability / authenticity. fixture shall be is 10322 complianced. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report withliable warranty of product / accessories from oem shal be submitted.all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . high power led flood light 200w...

Department Of Local Bodies - Rajasthan

33754183 street light supply work in ward no 1 to 30 street light supply work in ward no 31 to 60 , based on ruidp 2022 , providing & fixing of ik07 ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminum lm6 / adc12 material with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( uv stablzation report submitted for uv cover ) and secondary lens on each led & should be smd type . the system level luminaire efficacy >=120 lm / wt with high power leds is to be used and potted driver must be potted & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , input frequency 50hz±3% power factor >0.95 driver efficiency >85% , thd ( i ) <10% humidity 10% to 90% rh working temp 5c to 45c . driver current <1000ma shown in lm79 report. the luminaire shall be bis certified and t.c. certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , color rendering index >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced. , oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , led street light fixture 20 watt , led street light fixture 45 watt , led street light fixture 70 watt , led street light fixture 90 watt , providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 20 mm dia. , 25 mm dia. , 32 mm dia. , 40 mm dia. , supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discoms specifications. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , suspension clamp with eye hook & pole clamp , supply and fixing of lt porcelain pin insulator as per is 1445 1997 suitable for working voltage 1100 volts including all accessories like hot dip gi forged spindle of 260mm long and nuts etc as reqd as per standard discom specification. all as per pre approved by engineer in charge. for additional technical parameters of products / work refer annexure a attached with this bsr . , 105mm x 65mm , supply and fixing of porcelain shackle insulator as per is:1443 1979 suitable for working on 1100 volts including hot dipped gi accessories and heavy duty hardwares etc as requiredas per pwd / discom specification. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 75mm x 90mm , supplying and drawing of iso certified company made xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255 / 1995 and is 398 ( pt 4 ) / 1994 on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as requiredas per pwd / discom specification. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 1x16 sq. mm. ( insulated ) , 1 x 25 sq. mm. + 1x25 sq. mm. ( insulated ) , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 2 x 1.5 sq.mm , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose , suitable for 3 kw load direct lighting load ( single phase ) , suitable for 15 kw load ( three phase ) including contactor, mcb, cable glands, terminal block and locking arrangement , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. , 10.0 sq. mm 4 core , 16.0 sq. mm4 core , 25.0 sq. mm4 core...

Department Of Local Bodies - Rajasthan

33744040 street light supply work in ward no 1 to 30 street light supply work in ward no 1 to 30 , based on ruidp 2022 , providing & fixing of ik07 ip 66 protected led street light luminaire on existing bracket / pole. fixture made of powder coated single piece pressure die cast aluminum lm6 / adc12 material with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( uv stablzation report submitted for uv cover ) and secondary lens on each led & should be smd type . the system level luminaire efficacy >=120 lm / wt with high power leds is to be used and potted driver must be potted & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , input frequency 50hz±3% power factor >0.95 driver efficiency >85% , thd ( i ) <10% humidity 10% to 90% rh working temp 5c to 45c . driver current <1000ma shown in lm79 report. the luminaire shall be bis certified and t.c. certified. life expectancy equal or more than 50000 burning hrs with minimum 70% lumen maintened , color rendering index >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark / name engraved / embossing on die cast housing to allow traceability / authenticity. fixture shall be as per is 10322 complianced. , oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report with liable warranty of product / accessories from oem shall be submitted. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , led street light fixture 20 watt , led street light fixture 45 watt , led street light fixture 70 watt , led street light fixture 90 watt , providing & fixing of street light bracket made out from following size of b class , medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 20 mm dia. , 25 mm dia. , 32 mm dia. , 40 mm dia. , supply and fixing of following lt supporting accessories with nut bolt & clamps made out as per standard discoms specifications. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , suspension clamp with eye hook & pole clamp , supply and fixing of lt porcelain pin insulator as per is 1445 1997 suitable for working voltage 1100 volts including all accessories like hot dip gi forged spindle of 260mm long and nuts etc as reqd as per standard discom specification. all as per pre approved by engineer in charge. for additional technical parameters of products / work refer annexure a attached with this bsr . , 105mm x 65mm , supply and fixing of porcelain shackle insulator as per is:1443 1979 suitable for working on 1100 volts including hot dipped gi accessories and heavy duty hardwares etc as requiredas per pwd / discom specification. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 75mm x 90mm , supplying and drawing of iso certified company made xlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255 / 1995 and is 398 ( pt 4 ) / 1994 on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as requiredas per pwd / discom specification. all as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 1x16 sq. mm. ( insulated ) , 1 x 25 sq. mm. + 1x25 sq. mm. ( insulated ) , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from 99.99% purity copper, class 5 stranding in acc. to iec 60228 for lower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a or c , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existing surface or recessed pvc / ms conduit / casing capping including all as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work , refer annexure a attached with this bsr . , 2 x 1.5 sq.mm , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose , suitable for 3 kw load direct lighting load ( single phase ) , suitable for 15 kw load ( three phase ) including contactor, mcb, cable glands, terminal block and locking arrangement , providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed unarmoured / armoured aluminium cable of 1.1 kv grade as per pwd specification for electrical works in existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench , on existing cable trays or on surface etc. including making necessary connection, testing etc. as required of size and as per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) material : h4 grade aluminium conductor of purity >99.6 % & as per is:1554 p i / is :7098 p – i ( b ) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999 for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 ( part 0 to 64 ) for testing procedures. ( c ) oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities for cables . appropriate type test certificate / oem test report shall be submitted . all above as per pre approved by engineer in charge. for additional technical parameters of products / work , refer annexure a attached with this bsr. , 10.0 sq. mm 4 core , 16.0 sq. mm4 core , 25.0 sq. mm4 core...

Malaviya National Institute Of Technology - Rajasthan

33541574 open tender enquiry for procurement of street light materials 1 supply of p.v.c. / xlpe insulated & p.v.c. sheathed armoured cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make ( make rallison, havells, kei, polycab, rr kable, gloster , cci, finolex ) 1.1 6.0 sq.mm 4 core mtr. 1300 2 supply of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners. the pipe / bracket may be bend at desired angle as per the instruction of engineer in charge before supply of material. 2.1 40 mm dia. 7 feet pcs 40 3 supply of thermoplastic / pvc cable junction boxes of following sizes including clamps for holding the box, cost of din rail for mcb mounting, connectors for cables terminals, threaded cable glands made of polyamide material etc. complete in all respect. ( make hensel, spelsberg , neptune bals ) 3.1 175mm x 150mm x100mm each 40 4 supply of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( c tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 ( make schneider, l&t, legrand, abb, siemens, ge , havells, c & s ) 4.1 single pole mcb 6 / 10 a rating each 40 5 supply of isi marked p.v.c. insulated submersible cable confirming to is:694 with flexible copper conductor. ( make rr kabel , national, finolex, rallison, kei, l & t, polycab, havells ) 5.1 1.5 sq.mm 3 core flat / round mtr. 160 6 supply of out door timer panel complete with incomer mccb fp 16ka 63a thermal magnetic release, time switch, power contactor fp, power contactor fp, ind. light led r, y, b, control mcb 10ka c curve, outgoing mcb dp 10ka c curve control and power wiring, al bus bar of appropriate rating, enclsoure 1.6mm / 3.15mm outdoor type double door front opening with angle iron frame 35x35x5mm ( hight 600mm ) complete as required ( manufactured by : seimens, mile stone, coremetal craft ltd., adlac, advance, johns electric, neptune. make of the s / g: abb, legrand, schneider, seimens, l&t ) . the drawing of l.t. panel to be got approved from department before fabrication...

Department Of Local Bodies - Rajasthan

33241184 supply and fixing 20mtr. high mast light at bikaner stand reengus sikar supply and fixing 20mtr. high mast light at bikaner stand reengus sikar , supply, erection testing and commissioning of high mast lighting system (as per cp3 trt/1996 of ile, uk) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries, mast head assembly, two nos aviation obstruction neon lights, double drum type self sustaining winch, integral power tool( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes and cc foundation of m 15 grade complete as required. the mast is constructed from mild steel plates (as per bs en 10025) cut and folded to form a polygonal section, telescopic jointed and welding as per bs 5135. the complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. with all accessories, which also includs internal electrical cable and panel with foundation, erection & commissioning excluding luminaries and lamps 20 mtr hm (in 2 section) group 1 make :surya, utkarsh, aster,spark , p & f of ip 66 protected high power led flood light system with extruded aluminium housing , toughened glass diffuser with suitable lenses on led to achieve various beam angles, 240 volt, 50hz, of high power led lamps supplied with pre wired cable of 1 mtr. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumen be maintained. light output in red , green , blue, cool white or warm white colour as per engineers choice. fixtures shall be ce compliance high power led flood light 240 watt. group 1 , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose. suitable for 15 kw load (three phase) including contactor, mcb, cable glands, terminal block and locking arrangement , providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor armoured of is:7098 i/1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10.0 sq.mm 4 core , plate earthing as per is:3043 with copper earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c. finished chamber covered with hinged type with locking arrangement c.i. cover, c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. , supply following size b class g. i pipe confirming to is: 1239 p 1 (1990) with accessories for laying earth conductor/strip/cable in ground/surface/recess as required. 50 mm dia...

Department Of Local Bodies - Rajasthan

33241183 supply and fixing 20mtr. high mast light at bheraw ji modh shree madhopur road reengus sikar , supply, erection testing and commissioning of high mast lighting system ( as per cp3 trt / 1996 of ile, uk ) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries, mast head assembly, two nos aviation obstruction neon lights, double drum type self sustaining winch, integral power tool ( winch motor with control circuit ) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes and cc foundation of m 15 grade complete as required. the mast is constructed from mild steel plates ( as per bs en 10025 ) cut and folded to form a polygonal section, telescopic jointed and welding as per bs 5135. the complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. with all accessories, which also includs internal electrical cable and panel with foundation, erection & commissioning excluding luminaries and lamps 20 mtr hm ( in 2 section ) group 1 make :surya, utkarsh, aster, spark , p & f of ip 66 protected high power led flood light system with extruded aluminium housing , toughened glass diffuser with suitable lenses on led to achieve various beam angles, 240 volt, 50hz, of high power led lamps supplied with pre wired cable of 1 mtr. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumen be maintained. light output in red , green , blue, cool white or warm white colour as per engineers choice. fixtures shall be ce compliance high power led flood light 240 watt. group 1 , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose. suitable for 15 kw load ( three phase ) including contactor, mcb, cable glands, terminal block and locking arrangement , providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor armoured of is:7098 i / 1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10.0 sq.mm 4 core , plate earthing as per is:3043 with copper earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple , wire meshed funnel, and c.c. finished chamber covered with hinged type with locking arrangement c.i. cover, c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke / charcoal, testing of earth resistance as required. , supply following size b class g. i pipe confirming to is: 1239 p 1 ( 1990 ) with accessories for laying earth conductor / strip / cable in ground / surface / recess as required. 50 mm dia...

Rajasthan State Industrial Development And Investment Corporation Limited - Rajasthan

33141955 supply of different electrical and wss material at ind. area udyog vihar store room sriganganagar su 250 amp , 35 ka, adjustable o/l & adjustable s/c setting, ics = 100 % icu group 1 2 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947 4 1/iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required., 4 pole power contactors with following ac 1 rating, 160 amp group 1 3 250 amp , 35 ka, adjustable o/l & adjustable s/c setting, ics = 100 % icu labour rate 4 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947 4 1/iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required., 4 pole power contactors with following ac 1 rating, 160 amp labour rate 5 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required., single pole mcb, 6 a to 32 a rating group 1 6 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required., single pole mcb, 6 a to 32 a rating labour rate 7 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 10.0 sq.mm, 2 core armoured 8 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 16.0 sq.mm, 4 core armoured 9 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 25.0 sq.mm, 4 core armoured 10 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 50.0 sq.mm, 4 core armoured 11 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 10.0 sq.mm, 2 core labour rate 12 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 16.0 sq.mm, 4 core labour rate 13 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 25.0 sq.mm, 4 core labour rate 14 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 50.0 sq.mm, 4 core labour rate 15 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required, one day & week reserve (digital type ) group 1 16 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required, one day & week reserve (digital type ) labour rate 17 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of crca sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in group 1 18 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of crca sheet , required hardware ,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in labour rate ...

Department Of Local Bodies - Rajasthan

32913843 supply and fixing of accessory for led light 1 providing and fixing of street light bracket made out from following size of b class, medium class g.i. pipe confirming to is : 1239 p 1 ( 2004 ) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge. for additinal technical parameters of products / work, refer annexure a atteched with this bsr ( as per bsr pwd 2021 ) 25mm dia 2 32mm dia 3 p & f ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose. suitable for 15kw load ( three phase ) including contractor, mcb, cable glands, terminal block and locking arrangement. 4 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface or recessed conduit / casing capping including making connections etc. as required.2 x 1.5 sq.mm 5 fixing of led lights on existing poles with connecting wire etcall other works ( non bsr ) ...

Department Of Local Bodies - Rajasthan

32880751 supply and fixing of accessories for led lights. providing and fixing of street light bracket made out from following size of b class, medium class g.i. pipe confirming to is : 1239 p 1 (2004) with heavy duty pole clamp, saddles suitable fastners etc. as required. all as per pre approved by engineer in charge. for additinal technical parameters of products/ work, refer annexure a atteched with this bsr (as per bsr pwd 2021) 25mm dia 2354.00 mtr 220.00 517880.00 32mm dia 8903.00 mtr 271.00 2412713.00 p & f ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose. suitable for 15kw load (three phase) including contractor, mcb, cable glands, terminal block and locking arrangement. 195.00 each 20352.00 3968640.00 1 municipal corporation, bharatpur name of work : s&f of accessories for led lights. g schedule based on ruidp sor 2017 1 2 3 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 2 x 1.5 sq.mm 57000.00 mtr 26.00 1482000.00 4 fixing of led lights on existing poles with connecting wire etc all other works ( non bsr) ...

Department Of Local Bodies - Rajasthan

32616106 rate contract for supply of electric items for fy 2022 23 fr pvc insulated and sheated flexible aluminum conductor , fr pvc insulated and unsheathed flexible copper conductor , iso certified company made bee star rated copper wounded double ball bearing capacitor start , alumininum body and metallic blade ceiling fan pvc tap roll , isi marked dol starter, energy efficient energy saving ip 20 led bulb, ip 20 smd mid power led batten type integrated light , 12 13 ‘4 ‘5 16 17 t ..acth each each each each each each internal sunge protection of 2.s kv with siort & open circuit proection .thd < l0ao .p.r.o.q5. cri 80s. life time of minimum 500o0 burning hours with 70% of intial lunen inaintanned till life ends. cct 3000 k 4000 k i 57o0 k, .6000 ki’6500 k (as per ansi bin), naximum power consumption should nbi nore than the specified raring and fixture shall be or bis standard and trade mark certificate ( t.c.). manufactures word mark’ nune f.ngpnvwd/ennbossing screen _____ printing on housing, 4 ued tube shape nixtune 182o w (polycarbonatc base) ii supply of i5i marked cordiess beli with cordiess remnwe (230 volt ac operated) supply of street light bracket made out from following size of • b class. medium class 6.1. pipe confirming to is.: i2 p. i (c2004 ) with heavy’ dut) pole clamp. saddles suitable fastncrs etc. as reqinred. 25 mm dia. (o! mtr length) supply or street light tracket mude out from following size of • ii class:.medwm class (iul. ripe confirmine to is:it239 p . i (o20o4 ) with heavy duty pwle clamp. sadules suitable tds*ncrs etc. as required. 32 mm dia (01 mir length) supply of led street lieht drimer 20 25 wan (other speciiications as per requirement or ulb) is 19 supply of l.[l) street l.ighi drimer 40 50 wan (odier specificarinns as per requirement of ulb) supply of led street light driver 72 wait (other specifications as per reqpirenent of uli3i suoply of led street lighr driver 100 120 wan (other specifications as per requirenent of ulb) sgpply of led street light driver 200 watt other specificaiions as per requinenent ar ulh supply or surge protection dev ice (spd) 10 kv 20 sueply of 240415 v ac mcb with positive isolation of breaking capaci not less than 10 ka (13 c tripping characterisric as per type or load and site reqpirenent) 4kv impulse withstand voltage. as per pwd specification for electrical works with lsl marked is 8828(1996) conforming to iec 60898.1 2002. iec 6on47 2, low wan losses, trip tnee mechanisun . energ hmiting of class 3 as per iec, minimum phase termination capacity or 3ssqumm., conductorline load re.ersibilitk, label holuing facilitv. ip 20 contact protection. mmn. operation 20.000. rour pole mct3 6 a to 32 a raring e ____________________ suppiy of 240415 v ac mcb with posiiive isolation of breaking capaciiy not less than 10 ka (h c tripping charncteristic as per type of load and site requirmment) 4kv impulse withstand voltage, as per pwd specification for electrical works with lsl marked is 8828(1996) confonming to jec 6o898 i 2002. iec 60947 2, low watt losses. trip nnee mcctunisum . enengy limiting of class 3 as per iec, ninimum phnse termination capacity or 35sq.mn. . conductorline laad reversibilits, label holding facility. ii’ 20 contact prmtection. mmn. opcration’20,0w0, single poie mcii ôato32arating 4 a rating ______ 23 iroviding & using of ac operated heavy durb 230 /440 volt powrr cnntacwr as per pwd specification for electrisal works. isi marked isiec 60n47 4 i : 20wo having provision of’ mechankal iaterlocking, ausiliary coatacts, din rail mqunting — type 4 pole poner oontactorn with fallowing ac i ruting 2532 ame. _____ 24 sspply of 1ii0 240 v. ac, i ph. , 2 w astronomical time switch wiih surgc suppresspr, memrry cand. sunriwe i sunset selectable. sonfnare for programming including nauing connection, etc. as required. supply of 24i4i$ vacmcb with positive isolation of breaking capacity not less than 10 kx (b’ c tripping characteristic as per type of load and site reqrdrement) 4kv impulse withstand voltage. as per pwd specinication for electrical works wiah lsl marked is 8828(1996) conforming to iec 608?8 1 200c. if.c 60947 2. low watt losses. trip free mecharnsum , energy limiting or class 3 as per iec. mininum phase termination capacity or 3ssqumm. . conductorline load reversibilit3. label holuing facility . ip 20 contact protection. mmh. operat ion 20.00n. single pole mcii 21 i’ i— 25 t suppi of iz”.tens,on hoard with specification hasing 4 universal socker,,auto 1eaah detect wire connectionn. fuse protection • onuoff switch, posuer on lndicator 4 meter power cord. .1500 wan • 6 amp. maue:. anchor vinay bajaj. 26 supply of p.v.c. xlpe insulated & p.v.c. sheathed armouredaluminiuum cable meter of 1.1 kv grade as per pwd specification as required orsiie and as per points (a). (b). mentioned below: aa? material : fl4 gnade aluminium conductor of purity ;99.6 o & as per is:1554 p llls :7098 p ui8 (b) conductor shall hnse electrolytic aluminium confirming to is 8130. is 3975 lq.q for armouring or cables in armnoured cable items , is 5831 for sheath. is loxl0(part 01o64 )for testing procedtres. 16.0 sq.ntm 4 core • 27 supplyine of 1k07 ip 66 protected led street light luminaire on existing each brackerpok. fixture made or powder coated singk piece pressure die cast aluminum lm6 adci2 material with hear dissipation fins on housing ssith uv stabili,cd pctoughcncd glass cotter (uv stabltation report submitted tot’ uv coter ) and wecondary lens on each i.fd & should be smi) type the system lesel l.uminaire efmkacy 120 inn iwt with high powter lel)s is to he used and potted driser must be potted & has a unique bis r nunber ttith lnøut voltarc ac’l20 to led street light flood light l zau.h.1 with this rsr. high power ln)l 1ioou lignlt uu w 33 supply of isi make tp&n 4i5 v metal ciad hbc cuinrewire able switch fuse unit eaah with poncelain kit kat and confomming to is: 13947 p 1& iii. rating 63 a rating. make: l&tihavellsicg/abb ______________ 34 sgpply of isi make tp&n 4i5 v metal clad hbc cum rewire aaie switch fuse unit eaah with porcelain kit km and conforming to is: 13947 p l& ill. rating too a ratine. make: l&t,liavellscgdabh ________._. _____ 35 mcpcb wiih led 20 25 wait (other specifications as per requirement of ulb) each _mmm_ 36 mcpcb with lld 35 45 wan (other specifications as per requirement of uli) each 37 mcpcr with let) 90 i20 watt (other specifications as per requirement of ljlr) 38 suppi fr pvc insulated & unsheathed flexible copper conductor as per pwd meter specitication for electrisal works with isi marked (is:694) and as per is 8130 2013 or 1.1 kv grade wire should be made from 99.9wo purity copper. class 5 stranding in ace. to iec 60228 for lower watt loss, oxygen free ( <1o ppm) for less chances or oxidization and higher silver content for gives better conductivity insulmion pvc type a or c .flame retardant as wer is 1o8i0 53, better amperage rating as per vde 0298 part 4,4 x 6.0 sq.mm —..m 39 supplying and laying isi marked p.v.c. insuluted snbmersible cabie as per pwd meter specinication for electrical works confimmine to is:694 and as per is 8130 2013 of 1.1 kv grade .wire should be made from 99.99% purity copper, class 5 stranding in etc ...

Public Health Engineering Department - Rajasthan

32153283 supply of electrical and other items for operation and maintenance of urban and rural water scheme h3.i1ij.? £blame oritem 1. sparc parts for bcii make starter a contactor block 16 amp.(coon) 13 contactor block 25 amp. (noon) c contact kit set 16 amp. (sp90a) d contact kit set 25 amp. (sp90b) e auxiliary block f over load relay 13.2 20 amp. g over load relay 8.9 13.5 amp. h chtimer i on off switch i no volt coil k nc no 2 sparc j?arts for jyoti 1xiake oii immersed starter a relay 9 15 amp. b relay l2 20amp. c relay 15 25 amp. d relay 18 30 amp. e relay 24.40 amp. f base plate g contact kit set 16 amp. i contact kit set 25 amp. j timer 0.3sec. with transprain air brack k block 25 amp. l block l6amp.m moving bridge n star coil four wire 0 connection plate aidj.. vire j5xc fmscirc 100 am p. kuccha rubber fyoaniou2omr in m. seal compound mc.b. three phase lcj3. three phase 40 au m.cj3. three phase 63 m.c13. three phase 100 ami auto singel phase preventer three phase 4 pole mcb 40 ai three phase 4 nole mcb 63 amn.e mccb 4._pvc_copper wire as per isi marked (bsr pwd group i) a 0.75 sq mm b 1.00 sq mm c l.5sqmmn d 2.ssqmm e 4.oosgrnm 6.00 sq mm f g l0sqmm h flexible wire 23/76 as per is 5. ampere meter kound safe group ii pwd bsr electric a 0 30 amp. as per is b ‘ 0 50 amp. as per is c 0 100 amp. as per is 6. other lieu i a volt meter 0 500 volt three phase as per is b time switch one daily dial, 240 v ac fm/iqt c l&t rely 66 i 10 amp. d copper lugs 35 mm e copper lugs 70 mm r‘rsi4irtcr 200i250 taser for s/f saiier 36 mfd ase penal 2 hp exa blaj rubber bush rubte• l3usj with nut bolt trasfarmeroji isi mark gland don 10 mm gland don 12 mm ...

Department Of Local Bodies - Rajasthan

31773444 rate contract for supply of electric items for fy 2022 23. fr pvc insulated sheathed flexible aluminum conductor , double ball bearing capacitor start ceiling fan , pvc tap roll , dol starter , dol starter , ac with relay , led bulb , led tube lights , cordless bell , street light bracket led street ligth driver , surge protection device , , mcb ac operaed heavy power contractor , extension board , nlpe insulated street light luminaries , fixture , protected light controlled switch based mechnical digital time switch , metal clad hbc cum rewire switch fuese porcelam kit kat , ...

Department Of Local Bodies - Rajasthan

31767528 rate contract for supply of electric items for fy 2022 23. rate contract for supply of electric items for fy 2022 23. , supply of fr pvc insulated & sheathed flexible aluminum conductor isi marked ( is:694 ) of 1.1 kv grade and approved make. each coil have 90 mtr. length. 2.5 sq. mm 2 core . , supply of fr pvc insulated & sheathed flexible aluminum conductor isi marked ( is:694 ) of 1.1 kv grade and approved make. each coil have 90 mtr. length. 1.5 sq. mm 2 core. , supply offr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make.2 x 1.5 sq.mm make : group 1. , supply of double ball bearing capacitor start ceiling fan of approved make complete with regulator and other accessories as required. 1200 mm sweep make : cg / khaitan / baja / usha / orient / ortem / havells / polar , supply of pvc tap roll isi marked ( packet of 30 taproll ) , supply of isi marked dol starter. 3 phase 415 volt ac with relay range of 07 to 21 amp. , supply of isi marked 230 volt, 50 hz ac operated led bulb make: bajaj / surya / havells / cg.7 watt , supply of isi marked 230 volt, 50 hz ac operated led bulb make: bajaj / surya / havells / cg.15 watt , supply of isi marked led tube lights with following description: input power: 16w / 18w, input voltage: ac90~300v 50hz, color temperature: 3000k 6500k, beam angle: 120 deg, lumens: 1600, operating temperature: ( 20 deg to 60 deg centigrade ) make : bajaj / surya / havells / cg.watt: 16watt / 18 watt. , supply of isi marked cordless bell with cordless remote ( 230 volt ac operated ) , supply of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners etc. as required. 25 mm dia. , supply of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners etc. as required. 32 mm dia. , supply of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners etc. as required. 40 mm dia. , supply of led street light driver 20 25 watt ( other specifications as per requirement of ulb ) , supply of led street light driver 40 50 watt ( other specifications as per requirement of ulb ) , supply of led street light driver 72 watt ( other specifications as per requirement of ulb ) , supply of led street light driver 120 watt ( other specifications as per requirement of ulb ) , supply of led street light driver 200 watt ( other specifications as per requirement of ulb ) , supply of surge protection device ( spd ) 10 kv , supply of 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets make: group 1 ( ruidp sor 2017 ) four pole mcb 6 a to 32 a rating , supply of 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets make: group 1 ( ruidp sor 2017 ) single pole mcb 6 a to 32 a rating , supply of 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets make: group 1 ( ruidp sor 2017 ) single pole mcb 4 a rating , supply of ac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1having provision of mechanical interlocking, din rail mounting type make: group 14 pole ac 1 rating contactors up to 25 amp , supply of ac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1having provision of mechanical interlocking, din rail mounting type make: group 1 4 pole ac 1 rating contactors 33 to 45 amp , supply of analog time switch isi markedmake: l&t / havells / cg / abb , supply of extension board with specification having 4 universal socket , auto detect wire connection , fuse protection , on / off switch , power on indicator , 4 meter power cord, , 1500 watt , 6 amp. make: anchor / vinay / bajaj. , supply ofxlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminum conductor armored of is:7098 i / 1554 1 make : group 1 ( ruidp sor 2017 ) 16.0 sq.mm 4 core , supply of ip 65 / ip 66 protected street light luminaries. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power leds . diffuser / glass cover for ensuring ip 65 protection for lamp and control gear compartment, system lumen output of 100 lum / watt high power led. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumens maintained. fixture shall be in ce compliance. ip 65 protected led street light luminaries. led street light fixture 20 watt. make: group i ( ruidp sor 2017 ) , supply of ip 65 / ip 66 protected street light luminaries. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power leds . diffuser / glass cover for ensuring ip 65 protection for lamp and control gear compartment, system lumen output of 100 lum / watt high power led. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumens maintained. fixture shall be in ce compliance. ip 65 protected led street light luminaries. led street light fixture 45 watt. make: group i ( ruidp sor 2017 ) , supply of ip 65 / ip 66 protected street light luminaries. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power leds . diffuser / glass cover for ensuring ip 65 protection for lamp and control gear compartment, system lumen output of 100 lum / watt high power led. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumens maintained. fixture shall be in ce compliance. ip 65 protected led street light luminaries. led street light fixture 72 watt. make: group i ( ruidp sor 2017 ) , supply of ip 55 protected light controlled switch based mechanical / digital time switch without hampering of preset time and over ride facility for maintenance purpose. suitable for 3 kw load direct lighting load ( single phase ) including contactor, mcb, cable glands, terminal block and locking arrangement. make: group i ( ruidp sor 2017 ) , supply of ip 55 protected light controlled switch based mechanical / digital time switch withouthampering of preset time and over ride facility for maintenance purpose. suitable for 15 kw load ( three phase ) including contactor, mcb, cable glands, terminal block and locking arrangement. make: group i ( ruidp sor 2017 ) , supply of tp&n 415 v metal clad hbc cum rewire able switch fuse unit with porcelain kit kat and conforming to is:13947 p i&iii. rating 63 a rating. make: group i ( ruidp sor 2017 ) , supply of tp&n 415 v metal clad hbc cum rewire able switch fuse unit with porcelain kit kat and conforming to is:13947 p i&iii. rating 100 a rating. make: group i ( ruidp sor 2017 ) ...

Indian Army - Rajasthan

31436157 bids are invited for digital time switch 40a , digital time switch 65a total quantity : 18...

Panchayat Raj Department - Rajasthan

31404780 supply of items for providing of street light arrangement samast gram laxmipura me prakash vyavastha hetu strit light sthapana karya (gp laxmipura) samast gram laxmipura me prakash vyavastha hetu strit light sthapana karya (gp laxmipura) ubn zkt2122glob00123 , p & f ip 65protected led street light luminaire on existing bracket. fixture made from powder coated single piece pressure die cast aluminium housing with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( from 45 w onwards ) and should be secondary lens on each led. the system level luminaire efficacy >= 100 withhigh power leds of cree / nichia / osram / philips/seoulmake is tobe used. the led driver should be bis certified and input voltage frequency ac 110 to 270 v ac with input frequency 50 hz+ 3% power factor >.95 driver efficacy >85% thd (1) <10% humidity 10% to 90% rh working temperature 20c to 50c . life expectancy equal to or more than 50000burning hours with minimum 70% initial lumens maintained . rendering index >75%. surge protection shall be min>= 5kv internal and 10 kv external . manufacturer word mark/ name engraved / embossed on die cast housing to allow tracebility / authenticity till life of fixtures. fixtures shall be ce copmlianed bsr item no. pwd 2013 e304400 , led street light fixture 20 25 wattbsr item no. e304401 , s & f of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners etc. as required. 32mm dia 1200mm in lengthbsr item no. e203900 , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purposebsr item no. e204100 , suitable for 15 kw load (three phase) including contactor, mcb, cable glands, terminal block and locking arrangementbsr item no. e204102 , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.bsr item no. e040100 , 1 x 2.5 sq.mmbsr item no. e040106 , plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.bsr item no. e150300 , supplying and drawing ofxlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255/1995 and is 398 (pt 4)/ 1994 on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required as per discom specification.bsr item no. e212600 , 1 x 25 sq. mm. + 1x25 sq. mm. (insulated) bsr item no. e212603...

Directorate of Local Bodies - Rajasthan

31335752 rate contract for supply of electric items fr pvc insulated and sheathed flexible aluminum conductor, copper, ceiling fan, pvc tap roll, led tube lights, cordless bell, light bracket, led steet light, sugre protection device, analog time switch, extension board, fr pvc insualted and unsheathed flexible copper conductor, 1.1 kv grade with aluminum conductor armoured, isi marked pvc insulated submersible cable for fy2022 23....

Department Of Local Bodies - Rajasthan

31223093 supply of road light equipment 1. supply or fr pv ( insulated & sheathed flexible aluminum conductur 151 ( marked ( 15:694 ) or 1.1 ks grade and approved make. each coil have 90 mtr. length. 2.5 sq. mm 2 cores.. 2. supph of fr pwc insulated & sheathed flexibk aluminum conductor 1st marked ( 15:694 ) or 1.1 kv grade and *pproved make. each coil have 90 mtr. length. 1.5 sq. mm 2 core. 3. suppk of fr ps’c insulated & unsheathed flexible copper conductor 1s1 marked ( is:694 ) of 1.1 ks grade and approwed make. 2 z 1.s sq.mm %lake group i. supph or double ball bearing eapacitor start eeiling fan of approved nake complete with regulator and other accessories as required. 1200 mm ssweep slnke : ( :gi kbaltan1 baja / i ;hworirnt / orteni ) hlay elk! polar i.e supply of psc tap roll isi starked packet or 30 tap roll ) supply of 1st marked dol starter. 3 phase 415 ‘olt ac with relax range of 07 tos2l mp r ‘. supply of isi marked 230 volt. 50 hz ac operated led bulb slnke: bajaj / f surya / hlaxelkl cg. 7 watt n. supph of lsl marked 230 von. 54 ) hi ac operated lh ) bulb slake: llnjnjl surya / havetkl cc. lsswatt 9. supply of isi marked led tl be lights withfollowing description:i nppt? ponwer: 16wy1 1sv. input voltage: accs 3o0v 50hlz. color femperature: 3000k.bsook. beam angle: 120 deg, i.umens: 1600, operaing temperature: ( 20 deg to 60 deg centigrade ) slake : bajaji surya / has ellsj ( 1i. ‘att: lbwaw.13 watt. i 1i. suppiy of isi maried coriless beil wiih coriiess remote ( a30 sok ac i operated ii. lsppl of street lieht bracket made out from failowing size ofr’ b • class ( t! pipe with he*v dub pole clamp, saddles bultable fastners etc. as required. 2s nrnrndia 12. supph of street light bracket made out from following size or.’ b ‘ class gi pipe with heavy duty pole clamp. saddles suitable fastuers etc. us required. 32 mm dfia.. 13. supply of street light bracket made out from following size or.’ b clasn ( :1 pipe with heavy dut’ pole clamp. saddles suitable fastaera etc. is required. 40 mm dii. 14. supply or lee ) street light driver 20 2s watt ( other specifications as per eaci requirement of 1 ) 18 ) 15. supply or led street light driver 40 50 watt ( other specifications as per lad requlrernent of 1 ) 18 ) supply of led street light driver 72 watt ( other specifieations ns per lad 9uirement of lulb ) 17. supply of led street light driver 120 watt ( other specifications as per lad requirement or 11l8 ) _ 18. supply of led street light driver 200 watt ( othe’ specificatioiis as per fad requirementofulb ) _. 19. suppl of surge protection device ( spe ) ) ( 0 kv eacl 20. supply or 240 / 415 v mcb or breaking capadtv nnt less than i0 ka ( b / c / dteadi_ tripping characteristic ) is! marked is 8828 ( 1996 ) 1 / conforming to iec 60898 in existing board / sheets make: croup i ( rl1idp sor 2017 ) four pole %icb 6 a to 32 a rating _____ _______________ _____ eaci lac 21. 23. supply of 240 / 415 v %ich or breaking capacity not less than 10 ka ( hi cl d tripping characteristic ) is! marked is 8828 ( 1996 ) 1 / conrorming to iec 60898 in existing board, sheets make: group i ( rijidp 5ok 2017 ) single pole mcb 6 a to 32 a rating supply or 240 / 415 v nicb or breaking capacity not ies than 10 ka ( 81 c / d tripping characteristic ) isi marked is 8828 ( 1996 ) 11 conrorming to iec 60898 in existing board / sheets make: group i ( rtidp sor 2017 ) single pole mcb j:• rating supply of ae operated heavy duty 230 / 440 voltt power contactor conformlng to ead is: 13947 4 1 / i e ( :947 4 lhaving provision of mechanical interlocking, din rail mounting type make: group 1 4 pole ac i rating contactors up to 25 amp . uiouniin • 4npui nwiin nriataiors 33 10 mp 2$. supply of snalog time switch isi marked slnke:. l& r / havelk / cg, abb 26. %uppl or ikseension board with speeiflcation hsring 4 t ntversal socket , h.uto detect wire connection , fuse protection • ot%foff switch , power on indieator , 4 meter power cord, .1500 watt , 6 amp. make: anchor’ vinay / bajaj. _______ __ _______ ___e__________________e__ supply of xlpe insulated i p.v.c. sheathed cable or 1.1 kv grade with aluminum cunductor &rmored of is:’0w1* i / l$$4 l slake : ( roup i rt ii ) p soil 2017 ) 16.0 sq.mm4core ___e 28. supply of ( p 55 protected light controlled switch based mechanical i digital ll tine switch withour hampering or preser tine and over ride facility for i nnintenance purpse. suitable for 3 kw load direct lighring load ( single phasw ) including contactor. sick, cable glands, terminal block and locking arrangement. slake: group i ( rlli ) p sor 2017 ) 29. supply of ip ‘.s protected light eontrolled switch based mechanical i digital rine switch without hampering of preset time and over ride facitit for naintenance purpose. suitable for is kw load ( three phase ) including contactor. nick. cable glands. terminal block and locking arrangement. slake. ( group i ( rt idp soil 2017 ) — 30. supply of tp& 41s v metal elad hb ( eum rewire able switch fuse unit with porcelnin kit kat and eonforming to 15.s:13947 p i&lii. rating 63 a rating. slake: croup l ( r1uidp sor 2017 ) 31. supply of tp& 415 v metul clad hbc eun rewlreabue switch fuse unit with porcelnin klt kat and confonning to is: 13947 p l&lll. rating iou a rating. slake: group i ( rtiidp soil 2017 ) ...

Panchayat Raj Department - Rajasthan

31004657 supply of items installation of street light samast gram laxmipura me prakash vyavastha hetu strit light sthapana karya ( gp laxmipura ) samast gram laxmipura me prakash vyavastha hetu strit light sthapana karya ( gp laxmipura ) ubn zkt2122glob00107 , p & f ip 65protected led street light luminaire on existing bracket. fixture made from powder coated single piece pressure die cast aluminium housing with heat dissipation fins on housing with uv stabilized pc / toughened glass cover ( from 45 w onwards ) and should be secondary lens on each led. the system level luminaire efficacy >= 100 withhigh power leds of cree / nichia / osram / philips / seoulmake is tobe used. the led driver should be bis certified and input voltage frequency ac 110 to 270 v ac with input frequency 50 hz+ 3% power factor >.95 driver efficacy >85% thd ( 1 ) <10% humidity 10% to 90% rh working temperature 20c to 50c . life expectancy equal to or more than 50000burning hours with minimum 70% initial lumens maintained . rendering index >75%. surge protection shall be min>= 5kv internal and 10 kv external . manufacturer word mark / name engraved / embossed on die cast housing to allow tracebility / authenticity till life of fixtures. fixtures shall be ce copmlianed bsr item no. pwd 2013 e304400 , led street light fixture 20 25 wattbsr item no. e304401 , s & f of street light bracket made out from following size of b class gi pipe with heavy duty pole clamp, saddles suitable fastners etc. as required. 32mm dia 1200mm in lengthbsr item no. e203900 , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purposebsr item no. e204100 , suitable for 15 kw load ( three phase ) including contactor, mcb, cable glands, terminal block and locking arrangementbsr item no. e204102 , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existingsurface or recessed conduit / casing capping including making connections etc. as required.bsr item no. e040100 , 1 x 2.5 sq.mmbsr item no. e040106 , plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple , wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover, c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke / charcoal, testing of earth resistance as required.bsr item no. e150300 , supplying and drawing ofxlpe insulated lt aerial bunched aluminium conductor cable confirming to is 14255 / 1995 and is 398 ( pt 4 ) / 1994 on existing cross arms through i hook with all necessary t&p required including binding and twisting etc. complete in all respect as required as per discom specification.bsr item no. e212600 , 1 x 25 sq. mm. + 1x25 sq. mm. ( insulated ) bsr item no. e212603...

Department Of Local Bodies - Rajasthan

30453634 renovation work by installing decorative pole and post top led lights on heritage walk way in jaipur municipal corporation heritage area financial year 2021 22 , ( 44.1 ) supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make in existing surface or recessed conduit / casing capping including making connections etc. as required. , ( 44.1.7 ) 2 x 2.5 sq.mm , ( 45.2 ) p & f in position frame made out of m.s. angle ( riveted or welded ) finished with two coats of red oxide and enamel paint of following sizes as required. , ( 45.2.5 ) 50mm x 50mm x 6mm , ( 45.5 ) p & f sheet for boxes / frames including making holes for switches etc, with brass screws, washers / zinc plated nut and bolts as required. , ( 45.6 ) 3.0 mm thick synthetic phenolic resin bonded laminates confirming to is:2046 bakelite sheet , ( 46.6.2 ) 6.4 mm thick , ( 46.1 ) p&f 240 / 415 v mcb of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) ] / conforming to iec 60898 in existing board / sheets including making connections with lugs, testing etc. as required. , ( 46.1.1 ) single pole mcb , ( 46.1.1.2 ) 6 a to 32 a rating , ( 48.1 ) sitc of walll / free standing floor mounted dust and vermin proofcompartmentalised cubical panel made out of crca sheet, required hardware, duly painted by two coats of zinc / red oxide primer followed by powder coated / epoxy / pu painted with phosphatisation in grey or required shade after rinsing. the panel having pu / neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate m.s. base channel, hinged door with locking arrangement for equipment / switchgear. thickness of sheet shall not be less than 1.6mm up to 600mm length / width of any compartment and be of 2.0mm above 600mm. load bearing structure shall be of 2.0mm thick sheet supported by base m.s.channel if required. side walls and cable alley compartments having bolted type doors with detachable extension type structure ( only outer area on all sides shall be measured and panel to be fabricated from cpri approved fabricator ) . , ( 48.2 ) supplying and fixing of aluminium / copper bus bar by means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves , ( 48.2.1 ) electrolytic grade aluminium bus bar , ( 48.15 ) p & f of ac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1having provision of mechanical interlocking, din rail mounting type including making connections, testing etc. as required. , ( 48.15.2 ) 4 pole ac 1 rating contactors , ( 48.15.2.4 ) 46 to 60 amp , ( 48.20 ) p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required , ( 48.20.3 ) one day & week reserve ( digital type ) , ( 51.1 ) providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor armoured of is:7098 i / 1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. , ( 51.1.4 ) 10.0 sq.mm , ( 51.1.4.1 ) 2 core , ( 51.1.5 ) 16.0 sq.mm , ( 51.1.5.3 ) 4 core , ( 52.8 ) supplying and making one end termination with heavy duty double compression brass gland sibg type, aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed / xlpe aluminium conductor cable of 1100 volt grade as required of size. , ( 52.8.4 ) 2 x 10.0 sq.mm , ( 52.8.42 ) 4 x 16.0 sq.mm , ( 54.15 ) maintenance free gel earthing with pipe in pipe / strip in pipe technology filled with anti corrosive conductive compound ( cpri tested ) below the ground in 150 200 mm dia earth pit and surrounding filled with required mineral filling compound ( mfc should have hygroscopic proper ty to retain the moisture for long time to create low resistance zone ) and c.c. finished chamber covered with hinge type with locking arrangement c.i cover. c.i. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes with pipe in pipe technology ( inner pipe dia / outer pipe dia ) 80 100 micron g.i.coating , ( 54.15.1 ) with pipe in pipe technology with 80 100 micron g.i. coating , ( 54.15.1.2 ) g.i. pipe 2000 mm long , 80 / 40 mm , terminal 12 mm g.i. strip , ( 49.7 ) sitc of quick make and quick break 4 pole current limiting mccb having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings and conforming to is 13947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip , earth fault trip, push ( test ) to trip , including making connections with lugs / spreaders etc. as required , ( 49.7.1 ) with thermal magnetic release , ( 49.7.1.2 ) up to 100 amp , 16 / 25 ka, adjustable o / l & fixed s / c setting...

Department Of Local Bodies - Rajasthan

30332832 supply and fixing of high mast light in the municipal area banswara supply and fixing of high mast light in the municipal area banswara , providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor unarmoured of is:7098 i/1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.25.0 sq.mm4 core , supply, erection testing and commissioning of high mast lighting system (as per cp3 trt/1996 of ile, uk) consisting of totally hot dip galvanised by single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries, mast head assembly, two nos aviation obstruction neon lights, double drum type self sustaining winch, integral power tool( winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, suitable ropes and cc foundation of m 15 grade complete as required. the mast is constructed from mild steel plates (as per bs en 10025) cut and folded to form a polygonal section, telescopic jointed and welding as per bs 5135. the complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning of high mast. with all accessories, which also includs internal electrical cable and panel with foundation, erection & commissioning excluding luminaries and lamps 20mtr hm(in 2 section) make:aster,surya,utakersh , p & f of ip 66 protected high power led flood light system with extruded aluminium housing , toughened glass diffuser with suitable lenses on led to achieve various beam angles, 240 volt, 50hz, of high power led lamps supplied with pre wired cable of 1 mtr. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumen be maintained. light output in red , green , blue, cool white or warm white colour as per engineers choice. fixtures shall be ce compliance high power led flood light 200 watt , plate earthing as per is:3043 with copper earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c. finished chamber covered with hinged type with locking arrangement c.i. cover, c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. , g.i. pipe 50 mm dia as per is:1239 , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.3 x 2.5 sq.mm group 1 , p & f of aviation obstruction light luminaire comprising of yellow painted die cast aluminium alloy housing, built in 75 va step up transformer, heat resistant clear glass cover, neon spiral lamp complete in all respect group 1 , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purposesuitable for 15 kw load (three phase) including contactor, mcb, cable glands, terminal block and locking arrangement , supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required.6 x 4.0 sq.mm...

West Central Railway - Rajasthan

30257847 supply of supply of star delta starter panel boardsupply of star delta starter panel board,supply of star delta starter panel board suitable foe 7.5 hp submersible pump motor set 3 phase 415 volt ac complete as per following technical specification (1)push button with light 230v 2nos (2)auto time switch 16 amp230v 01 nos (3)single phasing preventer switch 415v 01 nos (4) digital ampere meter with selector switch 0 50amp 01nos(5)digital voltmeter 0 500 vac with selector switch 01 nos(6)mccb 3 pole breaking capacity 35ka. 32amp 01 nos(7)digital hour meter 230v 01 nos(8)hrc fuse unit 32 amp complete 3 nos(9)over load relay14 23 amp 01 nos (10)two way toggle switch 10 amp for manual and auto 01 nos(11) star dlta timer 0 60 sec. 01nos(12)03 pole power contactor 32 amp 3 phase with aux. block (2no+2nc) 03 nos (13)ct 50/5 per unit 3nos (14) control fuse 03 nos (15) water level control guard of 3 prode system 01nos (16)dimension 650x840x290mm. switch gear make abb,l&t,siemens,bch,hpl,gec or equivlant. note authorization certificate $ oem/challan/innvoice & test certificate with one year warranty on paper at the time of delivery. => limited...

Department Of Local Bodies - Rajasthan

30083845 supply of electrical equipment led bulb light , tube light danda , tube light choke , wire coil , ceiling fan , cooler motor water pump pad , mcb contactor, time switch , ...

Public Health Engineering Department - Rajasthan

29895246 supply electric and store material 1 armored aluminum cable isi marked 4 core – 25 sqmm. 2 tpn switch ( porcelain ) units isi marked 200a / 415 3 coupling rubber bush. i ) small ii ) medium iii ) big 4 cotton waste 5 hexa blade 6 transformer oil 7 pvc copper wire isi marked i ) 1.5 sqmm. ( 90 mt. per coil ) ii ) 2.5 sqmm. iii ) 5.0 sqmm ( 100 mt. per coil 8 pvc hose pipe : i ) 1” ii ) 1½” iii ) 2” iv ) 2½” v ) 3” 9 hrc fuse isi marked din type i ) 125 amp. ii ) 200 amp. iii ) 250 amp. iv ) 400 amp. 10 hrc fuse base isi marked i ) 250 a ii ) 400 a 11 oil paper size 12 ambari rope 13 segment time switch having power reserve 24 hour dial segment with 15 minute switching. 14 coupling bolts ½” x 3” coupling bolts ½” x 4” coupling bolts ¾” x 4” 15 c.t. operated square amp. meter isi marked 96 mm 0 to 100 a 16 c.t. operated square volt meter isi marked 96 mm 0 600 v 17 capacitor 36 mfd 18 mcb 16 amp. 2 pole 19 copper lugs heavy duty ( crimping type ) i ) 35 mm ii ) 50 mm iii ) 70 mm iv ) 95 mm v ) 120 mm vi ) 150 mm vii ) 300 mm viii ) 400 mm...

Department Of Local Bodies - Rajasthan

29620897 supply and erection of semi high mast lights at different palaces in nagar palika chaksu supply and erection of semi high mast lights at different palaces in nagar palika chaksu , supply and erection of octagonal pole of following length and dimension as per table 3 with base plate on the cement concrete foundation of m 15 /m 20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (is 1367 p iii ). the pole shall be made of s 355jo grade steel sheet , folded lengthwise to obtained octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with is 2629. the pole shall have a weatherproof flush door and locking arrangements. the complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 12 mtr , providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor armoured of is:7098 i/1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 3.5 core , providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor un armoured of is:7098 i/1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 2.5 sqmm, 2 core , plate earthling as per is:3043 with copper earth plate of size 600mm x 600 mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 25 mm dia. g.i. ‘b’ class watering pipe including allaccessories like nut, bolts, reducer, nipple, wire meshed funnel, andc.c. finished chamber covered with hinged type with lockingarrangement c.i. cover, c.i frame of size 300mm x 300mmcomplete with alternate layers of salt and coke/charcoal, testing ofearth resistance as required. , s & laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 25mm x 3mm g.i. strip , s & laying following size a class g.i. pipe with accessories for laying earth conductor/strip in ground/surface/recess as required 50 mm dia , p/ f ip 65/ ip 66 protected street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power leds . diffuser / glass cover for ensuring ip 65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power led. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumens maintained. fixture shall be in ce compliance. high power high power led flood light 180 watt , p & f of ip 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch off at preselected time. switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose suitable for 15 kw load (three phase) including contactor, mcb, cable glands, terminal block and locking arrangement , providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round hdpe dwc (double wall corrugated) pipes of sn8 grade as per is 16098 (part 2) amended upto date in trenches in complete including all material, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per technical...

West Central Railway - Rajasthan

29522192 supply of supply of direct on line starter panel 5 hp to 7.5 hp three phase 415 volt acsupply of direct on line starter panel 5 hp to 7.5 hp three phase 415 volt ac,supply of direct on line starter panel 5 hp to 7.5 hp three phase 415 volt ac , power coated 18swg sheet enclosure with pu gasket duly wiredand locking arrangement with key and two side ventilationlouvers having following specification (1) push button actuator with light 230 v 02 nos. (2) auto time switch withbypass (with switch ) arrangement 16 amp 01 nos. (3) single phase preventer 01 nos.(4) digital ampere meterwith selector switch 01 nos. (5) digital voltmeter 500v 01 nos.(6)mcb 32 amp 3 pole 01 nos. (7) hour meter230 v 01 nos. (8)hrc fuse unit 32 a complete 03 nos. (9) over load relay 9 14 amp 01 nos. (10)ledindicating lamp for motor on, motor trip &ryb phase indicator 05 nos. (11) 3 pole contactor 32 amp 3phase withaux. block (02no+02nc) 01 nos (12) ct 50/5 per unit 03 nos.(13) control fuse 2 amp 03 nos. (14) water levelcontroller with electrode 01 nos. (15) average dimension 840*650*290 mm. isi marks switch gear make: l&t ,siemens , bch , abb , minilec , havells , cg or equivalent. note : authorization certificate &oem/challan/innvoice & test certificate with one year warranty on paper at the time of delivery...

West Central Railway - Rajasthan

29298388 supply of supply of direct on line starter panel 5 hp to 7.5 hp three phase 415 volt acsupply of direct on line starter panel 5 hp to 7.5 hp three phase 415 volt ac, supply of direct on line starter panel 5 hp to 7.5 hp three phase 415 volt ac , power coated 18 swg sheet enclosure with pu gasket duly wiredand locking arrangement with key and two side ventilation louvers having following specification ( 1 ) push button actuator with light 230 v 02 nos. ( 2 ) auto time switch with bypass ( with switch ) arrangement 16 amp 01 nos. ( 3 ) single phase preventer 01 nos. ( 4 ) digital ampere meter with selector switch 01 nos. ( 5 ) digital voltmeter 500v 01 nos. ( 6 ) mcb 32 amp 3 pole 01 nos. ( 7 ) hour meter 230 v 01 nos. ( 8 ) hrc fuse unit 32 a complete 03 nos. ( 9 ) over load relay 9 14 amp 01 nos. ( 10 ) led indicating lamp for motor on, motor trip &ryb phase indicator 05 nos. ( 11 ) 3 pole contactor 32 amp 3phase with aux. block ( 02no+02nc ) 01 nos ( 12 ) ct 50 / 5 per unit 03 nos. ( 13 ) control fuse 2 amp 03 nos. ( 14 ) water level controller with electrode 01 nos. ( 15 ) average dimension 840*650*290 mm...

Urban Improvement Trust - Rajasthan

29138406 supply of electric items 1 led down light18 / 20 w round / square shape.bajaj, philips, surya, crompton, havells 2 led down light36 / 40 w 2x2 panel.bajaj, philips, surya, crompton, havells 3 led bulb 9 wattbajaj, philips, surya, crompton, havells 4 led bulb 15 wattbajaj, philips, surya, crompton, havells 5 led bulb 18 wattbajaj, philips, surya, crompton, havells 6 tube light led completebajaj, philips, surya, crompton, havells 7 tube lightcompletebajaj, philips, surya, crompton, havells 8 tube rode ledbajaj, philips, surya, crompton, havells 9 tube rodebajaj, philips, surya, crompton, havells 10 choke / ballastbajaj, philips, surya, crompton, havells 11 starterbajaj, philips, surya, crompton, havells 12 cfl 6 inch rode type four pin 18 wattbajaj, philips, surya, crompton, havells 13 cfl 6 inch rode type four pin 36 wattbajaj, philips, surya, crompton, havells 14 cfl 3inch rode type 2 pin 12 wattbajaj, philips, surya, crompton, havells 15 cfl 3inch rode type 2 pin 18 wattbajaj, philips, surya, crompton, havells 16 switch standard 6ampanchor, ssk, hi fi, precision, vimal 17 switch modular type 6 ampanchor, ssk, havells, abb, legrand, philips 18 non modular 6a hanging bell push one way switchanchor, ssk, havells, abb, legrand, philips 19 two way switch standard 6 amp.anchor, ssk, havells, abb, legrand, philips 20 two switch modular type 6 amp. anchor, ssk, havells, abb, legrand, philips 21 modular3 / 5 pin 6 amp.anchor, ssk, havells, abb, legrand, philips 22 standard3 / 5 pin 6 amp.anchor, ssk, hi fi, precision, vimal 23 power socket with switchmodular complete 16 amp.anchor, ssk, havells, abb, legrand, philips 24 power socket with switch standard complete 16 amp.anchor, ssk, hi fi, precision, vimal 25 power switch modular 16 amp.anchor, ssk, havells, abb, legrand, philips 26 power socket modular 16 amp.anchor, ssk, havells, abb, legrand, philips 27 power switch standard 16 ampanchor, ssk, hi fi, precision, vimal 28 power socket standardanchor, ssk, hi fi, precision, vimal 29 ceiling rose 6 amp.anchor, ssk, hi fi, precision, vimal 30 batten / angel lamp holder polycarbonate6 amp.anchor, ssk, hi fi, precision, vimal 31 3 pin plug top polycarbonate 6 amp. anchor, ssk, hi fi, precision, vimal 32 3 pin plug top polycarbonate 16 amp. anchor, ssk, hi fi, precision, vimal 33 2 pin telephone socket with plug topanchor, ssk, hi fi, precision, vimal 34 100 w rotary5 step fan regulatoranchor, ssk, hi fi, precision, vimal 35 buzzer 36 single / multi tone electronic call bell 37 3 way connector for fall ceiling 38 3 wire short connector 39 multiple socket with minimum four nos.universal6a socketone 6a switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr 40 following size mounting grid plates with coverplates 1 / 2 module 41 3 module 42 4 module 43 5 module 44 6 module 45 8 module 46 10 module 47 12 module 48 16 / 18 module 49 followingsizepolycarbonatemodular boxes 1 2 3 module 50 4 5 module 51 6 8 module 52 10 12 module 53 16 / 18 module 54 thermal overload relaywith buit in single phase protection and having atleast 1 no & 1 nc contactsup to 14 amp 55 14 to 23 amp. 56 20 to 33 amp. 57 modular mcb 6 to 32 amp. single polelegrand, abb, havells, l&t, schiender 58 modular mcb 6 to 32 amp. double polelegrand, abb, havells, l&t, schiender 59 mcb 6 32 a single polelegrand, abb, havells, l&t, schiender 60 mcb 6 32 a double polelegrand, abb, havells, l&t, schiender 61 mcb 32 a tri polelegrand, abb, havells, l&t, schiender 62 mcb 32 a four polelegrand, abb, havells, l&t, schiender 63 mcb 63 a triple polelegrand, abb, havells, l&t, schiender 64 mcb 63 a four polelegrand, abb, havells, l&t, schiender 65 supplyof quick make and quick break4 polecurrent limiting mccb having following current rating, short circuitbreaking capacityat 440 / 415 v, 50 hz; o / l & s / c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip , earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required.legrand, abb, havells, l&t, schienderup to 100 amp , 25 ka, adjustable o / l & fixed s / c setting, ics = 100 % icu 66 up to 125 amp , 25 ka, adjustable o / l & fixed s / c setting, ics = 100 % icu 67 160 amp, 25 ka, adjustable o / l & fixed s / c setting, ics = 100 % icu 68 200 amp , 25 / 35ka, adjustable o / l & fixed s / c setting, ics = 100 % icu 69 250 amp , 35 ka, adjustable o / l & fixed s / c setting, ics = 100 % icu 70 400 amp , 35 ka, adjustable o / l & adjustable s / c setting, ics = 100 % icu 71 supply ofac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required.legrand, abb, havells, l&t, schiender32 amp. 72 supply of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required.one day reserve ( mechanical type ) 73 one day & week reserve ( digital type ) 74 supply ofbus bar chamber housed in sheet metal box made out from 1.2 mm thick powder coated crca sheetfront openable bus bar made out of aluminium or wrought aluminium alloy suitable for 100 amp. capacity, bus barfixed on porcelain insulators at approved spacingincluding making connections etc. as required.300 mm long , 4 strip 75 supply of bus bar chamber housed in sheet metal box made out from 1.2 mm thick powder coated crca sheetfront openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. capacity, bus barfixed on porcelain insulators at approved spacingincluding making connections etc. as required.300 mm long , 4 strip 76 p&f recessed / surface mounting heavy duty vertical type 16 swg sheet steel distribution board with provision of incomer suitable for mcb / rccb and sp / tp mcb as outgoing , phophatised , powder painted complete with insulated suitable ratingcopper bus bar , neutral link, earth link and din bar, masking sheet, conforming to is13032 & is8623 including making internal db terminations with copper lugs , testing etc. as required.4 way single door 77 supply of oil / air breakdol / star deltastartermade out of sheet steelpowder coated enclosure withsingle phasing protection, on / offpush buttons, etc. complete in all respect suitable for following rating motors.dol starter3.0 h.p. to 10.0 hp 78 fully automatic star / deltastarter3.0 h.p. to 10.0 hp 79 12.5 hp to 17.5 hp 80 30.0 hp to 35.0 hp 81 40.0 hp to 50.0 hp 82 providingof hdpe pipe isi mark ( is:4984 / 95 ) for water supply ( suitable for submersible & jet pump ) with required fittings40 mm od4kg / cm2 83 50 mm od4 kg / cm2 84 fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv gradefinolex, polycab.kei 1 x 1.5 sq.mm 85 2 x 1.5 sq.mm 86 3x 1.5 sq.mm 87 4 x 1.5 sq.mm 88 1 x 2.5 sq.mm 89 2 x 2.5 sq.mm 90 2 x 2.5 sq.mm + 1 x 1.5 sq.mm 91 3 x 2.5 sq.mm 92 4 x 2.5 sq.mm 93 1 x 4.0 sq.mm 94 2 x 4.0 sq.mm 95 3 x 4 sq. mm. 96 4 x 4.0 sq.mm 97 isi marked ( is:694 ) 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor finolex, kei, polycab.4.0 sq.mm 98 6.0 sq.mm 99 10.0 sq.mm 100 p.v.c. insulated submersible cable confirming to is:694 with flexible copper conductorfinolex, polycab.kei, havells1.5 sq.mm 3 core flat / round 101 2.5 sq.mm 3 core flat / round 102 4.0 sq.mm 3 core flat / round 103 6.0 sq.mm 3 core flat / round 104 10.0 sq.mm 3 core flat / round 105 p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make .finolex, polycab.kei, havells, worldcab, paramount 10 sq. mm 4 core 106 16 sq. mm 4 core 107 f star rated double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cmas required.orient, bajaj, usha, crompton, havells.1200 mm sweep 5 star rated 108 pvc conduit pipe 25 mm 109 pvc conduit pipe 50 mm 110 pvc flexible pipe 25 mm 111 pvc flexible pipe 50 mm 112 pvc casing caping 25mmx12 mm 113 pvc casing caping38mmx25mm 114 pvc casing caping 50mmx50mm 115 multiple socket with 4 nos.6 a socket and one 6 a swith with 3 pin company fitted plug top 116 supply of b class g.i. pipe 50 mm 117 supply of ik09 recessed / surfaced mounting heavy duty horizontal type sheet steel of 1.6 mm thick distribution board.three phase 4 way 118 monoblock pressure boosting pump1 h.p. single phase.crompton, kirlosker 119 2 h.p.single phase crompton, kirlosker 120 submersible pump1 h.p. single phasecrompton, kirlosker 121 submersible pump 2 h.p. single phasecrompton, kirlosker 122 submersible pump3 h.p. single phasecrompton, kirlosker 123 submersible pump5 h.p. single phasecrompton, kirlosker...

State Agriculture Marketing Board - Rajasthan

29122638 supply of electrical items lt outdoor ht , ht joint , water level controller , sp mcb , pvc wire , cable , lt cable , change over switch pole , tape roll , delta starter , rcb mcb , time switch , mcb , high grade transformer oil , led street light flood light driver card , submersible cable indicator , digital meter ...

Rajasthan State Industrial Development And Investment Corporation Limited - Rajasthan

28876161 supply of different electrical material in store room at ind. area hanumangarh providing and fixing &f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc/toughened glass cover (from 45 w onwards) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree//nichia/osram/philips/seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd (i) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark/name housing to allow traceability/authenticity till life of fixture. fixtures shall be ce complianced., led street light fixture 80 watt composit 2 p&f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc/toughened glass cover (from 45 w onwards) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree//nichia/osram/philips/seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd (i) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark/name housing to allow traceability/authenticity till life of fixture. fixtures shall be ce complianced., led street light fixture 45 watt composit 3 p&f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc/toughened glass cover (from 45 w onwards) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree//nichia/osram/philips/seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd (i) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark/name housing to allow traceability/authenticity till life of fixture. fixtures shall be ce complianced., led street light fixture 80 watt rate (rs) 4 p&f ip 65 protected led street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with uv stabilized pc/toughened glass cover (from 45 w onwards) and should be secondary lens on each led. the system level luminaire efficacy >=100 with high power leds of cree//nichia/osram/philips/seoul make is to be used. the led driver shall be bis certified and input voltage ac 110 to 270 v ac with input frequency 50hz+ 3% power factor >0.95 driver efficiency >85%, thd (i) <10% humidity 10% to 90% rh working temp 20c to 50c. life expectancy equal or more than 50000 burning hrs with minimum 70% initial lumens maintained, rendering index >75%. surge protection shall be min> 5kv internal and min 10 kv external. manufactures word mark/name housing to allow traceability/authenticity till life of fixture. fixtures shall be ce complianced., led street light fixture 45 watt rate (rs) 5 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 6.0 sq.mm, 2 core unarmoured 6 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 10.0 sq.mm, 2 core unarmoured 7 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 10.0 sq.mm, 2 core labour rate 8 p/laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size., 6.0 sq.mm, 2 core labour rate 9 supply and fixing of oil / air break starter panel made out of sheet steel powder coated enclosure comprising of over load protection relay, short circuit & single phasing protection, on / off push buttons, ammeter, voltmeter, indicating lamps etc. complete in all respect suitable for following rating motors., for three phase submersible / mono block pump, 20.0 hp to 25.0 hp ( star / delta ) group 1 10 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required., single pole mcb, 6 a to 32 a rating group 1 11 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947 4 1/iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required., 3 pole power contactors with following ac 3 rating, 40 to 50 amp group 1 12 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required, one day & week reserve (mechanical type ) group 1 13 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required., single pole mcb, 6 a to 32 a rating labour rate 14 p & f of ac operated heavy duty 230 /440 volt power contactor conforming to is:13947 4 1/iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required., 3 pole power contactors with following ac 3 rating, 40 to 50 amp labour rate 15 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required, one day & week reserve (mechanical type ) labour rate ...

Rajasthan State Mines And Minerals Limited - Rajasthan

28506689 supply of electrical items 1.01 lamp, metal halide screw type single ended, 250 watt, 240 volts 1.02 lamp, metal halide screw type single ended 400 watt, 240 volts, 1.03 lamp metal halide screw type single ended , 70 watt, 240 volts, 1.04 lamp , metal halide screw type single ended, 150 watt, 240 volts 1.05 lamp, metal halide, double ended, 70 watt, 240 volts 1.06 lamp hpsv 70 watt 240 volt, screw cap type 1.07 lamp hpsv 250 watt 240 volt, screw cap type 1.08 lamp hpsv 150 watt 240 volt, screw cap type 1.09 lamp hpsv 400 watt 240 volt, screw cap type 1.10 halogen lamp / rod, 500 w, 240v 1.11 halogen lamp 1000 watt, 240 volts 1.12 bulb clear 500 watt, 240 volts 1.13 bulb pin type clear 240 volt 60 watt 1.14 choke ballast for hpsv 70w / 240v 1.15 choke ballast for hpsv 150w / 240v 1.16 choke ( ballast ) for hpsv lamp 250w, 240v 1.17 choke for hpsv lamp, 400 w, 240v 1.18 fitting of halogen lamp 1000 watt 1.19 fitting of halogen lamp 500 watt 1.20 igniter for hpsv lamp 70 400 watt, 240volts 1.21 ceiling fans single phase, size 48 with mounting gi pipe length 3 but without regulator 1.22 electronic regulator for above ceiling fan 1.23 automatic light control switch 25 amp, single phase ( photo switch ) with sensor complete ( indoor type ) 1.24 photosensor model pa 2 c sd 0.9 mtr 1.25 holder porclein screw type suitable for 150 / 250 / 400 w hpsv lamp 1.26 pvc insulation tape roll self adhesive tape ( 1.80 cm x 7 m x 0.125 mm ) 1.27 capacitor for ceiling fan 2.5 mfd 240v / 440 volts 1.28 capacitor for coolers , 4 mfd 240 volt 1.29 pvc insulated flexible copper wire size 1.5 sq. mm, ( red ) ( 90 meter / coil ) 1.30 pvc insulated flexible copper wire size 1.5 sq. mm, ( black ) ( 90 meter / coil ) 1.31 pvc insulated flexible copper wire size 1.0 sq. mm, ( red ) ( 90 meter / coil ) 1.32 pvc insulated flexible copper wire size 1.0 sq. mm, ( black ) ( 90 meter / coil ) 1.33 pvc insulated flexible copper wire size 0.75 sq. mm, ( green ) ( 90 meter / coil ) 1.34 pvc insulated flexible copper wire size 2.5 sq. mm, ( red ) ( 90 meter / coil ) 1.35 pvc insulated flexible copper wire size 2.5 sq. mm, ( black ) ( 90 meter / coil ) 1.36 pvc insulated flexible copper cable size 2 core , 1.5 sq. mm, ( 100 meter / coil ) 1.37 pvc insulated flexible copper cable size 3 core , 1.5 sq. mm, ( 100 meter / coil ) 1.38 pvc insulated flexible copper cable size 3 core , 2.5 sq. mm, ( 100 meter / coil ) 1.39 pvc insulated flexible copper cable size 4 core , 1.5 sq. mm, ( 100 meter / coil ) 1.40 pvc insulated aluminium conductor unarmoured cable size 2 core , 1.1 kv , 1.5 sq. mm 1.41 pvc insulated aluminium conductor unarmoured cable size 4 core , 1.1 kv , 1.5 sq. mm 1.42 pvc insulated aluminium conductor unarmoured cable size 4 core , 1.1 kv , 2.5 sq. mm, 1.43 gi earth wire, size 8 swg 1.44 gi earth plate size 2*2, thickness 6.00 mm 1.45 gi pipe size 1.c class for earthing work ( 6” x10 ) 1.46 mcb four pole 63 amps, 240 / 415 volts, c type. 1.47 mcb four pole 16 amps, 240 / 415 volts, c type. 1.48 mcb single pole 16 amps, 240 / 415 volts, c type. 1.49 mcb single pole 32 amps, 240 / 415 volts, c type. 1.50 mcb double pole 16 amps, 240 / 415 volts, c type. 1.51 mcb double pole 32 amps, 240 / 415 volts, c type. 1.52 mcb three pole 16 amps, 240 / 415 volts, c type. 1.53 mcb three pole 32 amps, 240 / 415 volts, c type. 1.54 mcb 4 pole , 32 ampere , 440 volt 1.55 elcb 63 ampere, 4 pole , 440 volt ( sensitivity= 30 ma ) din rail mounting 1.56 elcb 63 ampere, 4 pole , 440 volt ( sensitivity =300 ma ) din rail mounting 1.57 elcb 32 ampere , 4 pole , 440 volt ( sensitivity =300 ma ) din rail mounting 1.58 time switch / 24 hour day timer analog type 240 volt ac, 50 hz for automatic light control purpose 1.59 silica gel ( blue ) for use in the breather of transformers 1.60 led tubelight fitting 20w, 240v ac complete, 4feet long 1.61 led tubelight fitting 9 / 10w, 240v ac complete, 2feet long 1.62 led tube light 20 watt , 230 volt ac retrofit type , suited for installation in existing installed philips make ( 2x40 ) watt tube light fitting of 4 feet length 1.63 led street light fitting 30 / 40 watt , 230 volt ac suited for installation on pipe 1.64 led street light fitting 20 / 25 watt , 230 volt ac, suited for installation on pipe 1.65 led street light fitting 120 watt , 230 volt ac, suited for installation on pipe 1.66 led flood light fitting 30 / 40 watt, 230 volt ac clamp mounting type 1.67 led flood light fittings 120 watt , 230 volt ac clamp mounting type suitable for installation on flood light tower 18 meter 1.68 led flood light fittings 200 watt , 230 volt ac clamp mounting type suitable for installation on 20 meter high mast lighting tower 1.69 led industrial high bay light fittings 120 watt , 230 volt ac corvus / hemispherical hanging type 1.70 led tube light 9 / 10 watt , 230 volt ac retrofit type , suited for installation in existing installed philips / cgl make tube light fitting 20 watt in 2 feet length 1.71 led flood light fitting 350 watt , 230 v ac clamp mounting type suitable for installation on 20 meter hmlt 1.72 hrc fuse 16 ampere , 660 volt , round shape tia type of ge make or equivalent 1.73 hrc fuse 16 ampere , 415 volt , round shape eit compact type of ge make or equivalent 1.74 hrc fuse 25 ampere , 660 volt , round shape tia type of ge make or equivalent 1.75 hrc fuse 25 ampere , 415 volt , round shapeeit compact of ge make or equivalent 1.76 hrc fuse 32 ampere , 660 volt , round shape tia type of ge make or equivalent 1.77 hrc fuse 32 ampere , 415 volt , round shape eit compact of ge make or equivalent 1.78 hrc fuse , 63 ampere , 660 volt round shape tis type of ge make or equivalent 1.79 hrc fuse , 63 ampere , 415 volt round shape tss type of ge make or equivalent 1.80 hrc fuse 2 ampere , 415 volt round shape staggered tag type of ge make or equivalent 1.81 hrc fuse , 4 ampere, 415 volt , round shape ns offset type of ge make or equivalent 1.82 hrc fuse , 6 ampere, 415 volt , round shape ns offset type of ge make or equivalent 1.83 hrc fuse , 32 ampere, 415 volt , offset tag type eit of ge make or equivalent 1.84 hrc fuse , 63 ampere, 415 volt , offset tag type eit of ge make or equivalent 1.85 hrc fuse , 125 ampere, 415 volt , offset tag type tsds of ge make or equivalent 1.86 hrc fuse base with grip bakellite 100 ampere for offset tag round hrc fuse 1.87 hrc fuse base with grip bakellite 63 ampere for offset tag round hrc fuse 1.88 hrc fuse link 200 ampere , 415 volt size b2 , central tag type stf 200 ampere standard make or equivalent 1.89 hrc fuse link 100 ampere , 415 volt size b2 , central tag type stf 100 ampere standard make or equivalent 1.90 hrc fuse , 6 ampere, 415 volt , round shape , ns offset type type of ge make or equivalent 1.91 hrc fuse , 10 ampere, 415 volt , round shape ns offset type of ge make or equivalent 1.92 hrc fuse link , 125 ampere , 415 volt , offset tag type tsds of ge make or equivalent 1.93 hrc fuse , 16 ampere , 415 volt , round shape ns offset type of ge make or equivalent 1.94 hrc fuse 2 ampere , 415 volt , round shape hf type of l&t make or equivalent 1.95 hrc fuse 4 ampere , 415 volt , round shape , hf type of l&t make or equivalent 1.96 hrc fuse 6 ampere , 415 volt , round shape , hf type of l&t make or equivalent 1.97 hrc fuse 10 ampere , 415 volt , round shape , hf type of l&t make or equivalent 1.98 hrc fuse 16 ampere , 415 volt , round shape , hf type of l&t make or equivalent 1.99 hrc fuse 25 ampere , 415 volt , round shape , hf type of l&t make or equivalent 2.00 hrc fuse 32 ampere , 415 volt , round shape , hf type of l&t make or equivalent 2.01 hrc fuse 63 ampere , 415 volt , round shape , hf type of l&t make or equivalent 2.02 hrc fuse , 6 ampere , voltage 415 volt , eit type round shape of ge make or equivalent 2.03 hrc fuse 10 ampere , 415 volt , eit type of ge make or equivalent 2.04 hrc fuse 63 ampere , 415 volt , eit type of ge make or equivalent 2.05 hrc fuse, 100 ampere , 415 volt , tsdc central tag type of ge make or equivalent 2.06 hrc fuse 200 ampere , 415 volt , tsf central tag type of ge make or equivalent 2.07 hrc fuse 125 ampere , 415 volt , tsf central tag type of ge make or equivalent 2.08 hrc fuse 250 ampere , 415 volt , tsk central tag type of ge make or equivalent 2.09 hrc fuse 25 ampere , 415 volt square shape size 00 2.10 hrc fuse 32 ampere , 415 volt square shape size 00 2.11 hrc fuse 50 ampere , 415 volt square shape size 00 2.12 hrc fuse 63 ampere , 415 volt square shape size 00 2.13 hrc fuse 100 ampere , 415 volt square shape size 00 2.14 hrc fuse 125 ampere , 415 volt square shape size 00 2.15 hrc fuse 250 ampere , 415 volt square shape size 2 2.16 hrc fuse 250 ampere , 415 volt square shape size 3 2.17 hrc fuse , 400 ampere , 415 volt , square shape type iec size 3 2.18 hrc fuse , 315 ampere , 415 volt , square shape type iec size 3 2.19 ht hrc fuse 6.3 ampere , 11 kv , 40 kamp , type h3cas of ge make or equivalent 2.20 ht hrc fuse 100 ampere , 3.3 / 6.6 kv , offset tag type model no. k81pex of ee make equivalent 2.21 drop out fuse element for 11 kv , 10 ampere 2.22 drop out fuse element for 11 kv , 15 ampere 2.23 drop out fuse element for 11 kv , 20 ampere 2.24 drop out fuse element for 11 kv , 30 ampere 2.25 drop out fuse element for 11 kv , 40 ampere 2.26 drop out fuse element for 11 kv , 60 ampere 2.27 drop out fuse element for 11 kv , 75 ampere 2.28 wall fan, sweep 400mm, single phase 230v ac, 50hz , no of blade 3, 3 speed, motor type high speed, pull chord to operate fan, with complete accessories i.e. mounting kit , 2.29 exhaust fan single phase 230vac, 50hz, sweep 300mm, metal body with all accessories for mounting. 2.30 exhaust fan single phase 230vac, 50hz, sweep 380 mm, metal body with all accessories for mounting. 2.31 exhaust fan single phase 240vac, 50hz, sweep 450 mm, metal body with all accessories for mounting. 2.32 cable end termination kit for 3core xlpe cable 3x95 sqmm, heat shrinkable type, isi mark. 2.33 flexible cable repair and jointing kit resin type for atc trailing cable rated 1.1 kv power cable 50 square mm having 6 core of overall size ( 3 x 50 + 3 x 50 / 3 ) square mm and overall outer cable diameter 50 mm. 2.34 flexible cable repair and jointing kit resin type for atc trailing cable rated 1.1 kv power cable 95 square mm having 6 core of overall size ( 3 x 95 + 3 x 95 / 3 ) square mm and overall outer cable diameter 58 mm....

Department Of Local Bodies - Rajasthan

27542228 supply of electrical material and line extension work. mercury 125 watt complete bulb, chock, condesner, ignetor, cfl 45 watt complete set, led , wire, cable, main switch, automatic time switch, timer box, timer watch, fuse, hrc fuse, togal switch, indicator, coil, pvc pipe, gi pipe, himask pole, aluminium wire , tubularo pole, gardern pole, dourble rm nut botl with mcb box, abc cable, etc....

Urban Improvement Trust - Rajasthan

27490514 estimate for purchasing material for maintenance of road lights , high mast lights . nit21 / 2020 21 / item21 estimate for purchasing material for maintenance of road lights , high mast lights 1 providing of ac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type 3 pole power contactors with following ac 3 rating n70 amp 2 providing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes none day reserve ( mechanical type ) 3.1 providing of p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. ( make hevells, kei, plycab ) n4.0 sq.mm n2 core ( unarmoured ) 3.2 providing of p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. ( make hevells, kei, plycab ) n6.0 sq.mm n2 core ( unarmoured ) 4.1 supplying of fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make as required. n1 x 1.5 sq.mm 4.2 supplying of fr pvc insulated & unsheathed flexible copper conductor isi marked ( is:694 ) of 1.1 kv grade and approved make as required. n2 x 2.5 sq.mm 5.1 providing 240 / 415 v isolator conforming to is:13947 iii / iec 60947 3 as required. ( make hevells, c&s, schreider, l&t ) ntriple pole isolator n30 a / 40 a rating 5.2 providing 240 / 415 v isolator conforming to is:13947 iii / iec 60947 3 as required. ( make hevells, c&s, schreider, l&t ) nfour pole isolator n63 a rating 6.1 providing vacuum pressure impregnated copper ballast suitable for hpmv / hpsv / metal halide lamp luminaire as required. nfor hpsv / metal halide lamp n250 watt 6.2 providing vacuum pressure impregnated copper ballast suitable for hpmv / hpsv / metal halide lamp luminaire as required. nfor hpsv / metal halide lamp n400 watt 7.1 p & f normal / high output high pressure sodium vapour / metal halide / halogen lamp as required. nmetal halide lamp single ended tubular n250 watt 7.2 p & f normal / high output high pressure sodium vapour / metal halide / halogen lamp as required. nmetal halide lamp single ended tubular n400 watt 8 p & f electronic ignitor suitable for hpsv / metal halide lamp up to 30.0 mtr. distance as required. ( make hevells, c&s, schreider, l&t ) 9 wiring for sub mains isi marked ( is:694 ) 1100 volts grade pvc insulated flat twin core sheathed solid aluminium conductor with 10 swg g.i. support wire duly clipped etc. as required. ( make pollycab, havells, kei ) n4.0 sq.mm...

Department Of Local Bodies - Rajasthan

27428501 supply of time switch item. 25 ampiror conctecor 11 kv, gic timer watch, kitkit fuse, wire 7 / 16 aluminium single core, tape roll, led tube light, led bulb, gi pipe bracket with nut bolt complete , single pole...

Department Of Local Bodies - Rajasthan

27358556 rate contract for supply of electric items for fy 2021 22. fr pvc insulated , double ball bearing capacitor, dol starter, led tube lights, street light, led street light driver, protection device, mcb, ac operated , analog time switch, extension board, xlpe , ...

Development Authority - Rajasthan

27130621 rate contract for supply of electric items for annual maintenance of electric system at amber palace , jaipur. 1 supply of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c / d tripping characteristic ) isi marked is 8828 ( 1996 ) / conforming to iec 60898. as required. gr 1 item 1 2 1.1 single pole 6a to 32 a rating item 2 25 each 3 1.2 40a 63a double pole item 3 5 each 4 1.3 40 a 63 a rating tpn ( four pole ) item 4 10 each 5 2 supply of isi marked 6 amp bakelite batten / angle holder gr 1 item 5 60 each 6 3 supply of is: 371 marked 6 amp surface type ceiling rose as required gr 1 item 6 20 each 7 4 supply of following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts. as required item 7 8 4.1 6 a one way switch item 8 50 each 9 4.2 bell push item 9 16 each 10 4.3 16a one way switch item 10 30 each 11 4.4 6a socket item 11 30 each 12 4.5 16a socket item 12 20 each 13 4.6 5 srep fan regulator item 13 10 each 14 5 providing following size mounting grid plates with cover plates. gr. 1 item 14 15 5.1 1 / 2 module item 15 30 each 16 5.2 3 module item 16 30 each 17 5.3 4 module item 17 30 each 18 5.4 5 / 6 module item 18 20 each 19 5.5 8 module item 19 20 each 20 5.6 10 / 12 module item 20 10 each 21 6 p & f following size hot dip galvanized m.s. box of 20 swg with earthing terminal in recess / surface suitable for modular accessories as required. item 21 22 6.1 3 module item 22 20 each 23 6.2 4 module item 23 20 each 24 6.3 5 6 module item 24 20 each 25 6.4 8 module item 25 20 each 26 7 supply of quick make and quick break 4 pole current limiting mccb having following current rating, short circuit breaking capacity at 440 / 415 v, 50 hz; o / l & s / c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip , earth fault trip, push ( test ) to trip , including making connections with lugs & spreaders, etc. as required. nwith thermal magnetic release item 26 27 7.1 up to 100 amp , 16 ka, fixed o / l & s / c setting item 27 1 each 28 7.2 250 amp, 35ka, adjustable o / l & fixed s / c settings, lcs = 100% lcu item 28 1 each 29 8 supplying of end termination with heavy aluminium lugs ( pin / ring type ) duly crimped with crimping tool, pvc tape etc. of following size, gr. 1 item 29 30 8.1 10.0 sq.mm item 30 50 each 31 8.2 16.0 sq.mm item 31 50 each 32 8.3 25.0 sq.mm item 32 50 each 33 8.4 35.0 sq.mm item 33 50 each 34 8.5 50.0 sq.mm item 34 50 each 35 8.6 70.0 sq.mm item 35 40 each 36 8.7 95.0 sq.mm item 36 40 each 37 8.8 120.0 sq.mm item 37 40 each 38 8.9 150.0 sq.mm item 38 40 each 39 9 supply of fluorscent tube road in existing fixtures as required, minimum 3 star rating gr 1 flourscent powder coated n36 / 40 watts item 39 20 each 40 10 supplying fr pvc insulated& unsheathed flexible copper conductor isi marked ( is:694 ) 1.1kv grade and approved make etc. as required gr 1 item 40 41 10.1 1.5 sq.mm item 41 200 each 42 10.2 2.5 sq.mm item 42 200 each 43 10.3 4.0 sq.mm item 43 200 each 44 11 supplying of capacitor of 230v / 275v, 50hz rating of usha / punsumi / priya / capital / jec / amcap / concap make nrunning capacitor item 44 45 11.1 2.5 / 3.15 micro farad item 45 10 each 46 11.2 4.0 micro farad item 46 10 each 47 12 p / laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. item 47 48 12.1 10.0 sq.mm, 4 core item 48 50 mtr. 49 12.2 16.0 sq.mm, 4 core item 49 50 mtr. 50 12.3 25.0 sq.mm, 4 core item 50 50 mtr. 51 13 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required item 51 52 13.1 one day & week reserve ( digital type ) item 52 5 each 53 14 p & f of ac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required. item 53 54 14.1 4 pole power contactors with following ac 1 rating item 54 55 14.2 up to 32 amp item 55 7 each 56 14.3 100 amp item 56 2 each 57 15 p & f fluorscent tube rod in existing fixtures as required, flourscent powder coated 36 / 40 watts item 57 20 each 58 16 p & f ballast for existing ftl / cfl fixture as required., high frequency electronic ballast 18 / 36 watts for ftl item 58 15 each 59 17 p / laying isi marked p.v.c. insulated submersible cable confirming to is:694 with flexible copper conductor including making connection etc. as required. n6.0 sq.mm 3 core flat / round item 59 200 mtr....

Amber Development And Management Authority - Rajasthan

27116399 rate contract for supply of electric items for annual maintenance of electric system at amber palace, jaipur. 12 p / laying p.v.c. / xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 12.1 10.0 sq.mm, 4 core mtr. 50.00 120.00 6000.00 12.2 16.0 sq.mm, 4 core mtr. 50.00 128.00 6400.00 12.3 25.0 sq.mm, 4 core mtr. 50.00 172.00 8600.00 13 p&f of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and ac1 rating of 16 20 amperes including making connection, programming etc. as required 13.1 one day & week reserve ( digital type ) each 5.00 5746.00 28730.00 14 p & f of ac operated heavy duty 230 / 440 volt power contactor conforming to is:13947 4 1 / iec:947 4 1 having provision of mechanical interlocking, auuxilary contacts, din rail mounting type including making connections, testing etc. as required. 14.1 4 pole power contactors with following ac 1 rating 14.2 up to 32 a 15 p & f fluorscent tube rod in existing fixtures as required, flourscent powder coated 36 / 40 watts each 20.00 63.00 1260.00 16 p & f ballast for existing ftl / cfl fixture as required., high frequency electronic ballast 18 / 36 watts for ftl each 15.00 575.00 8625.00 17 p / laying isi marked p.v.c. insulated submersible cable confirming to is:694 with flexible copper conductor including making connection etc. as required. 6.0 sq.mm 3 core flat / round 1 pvc tape roll 3 / 4 steel grip make , led bulb, led , led driver...

LNM Institute of Information Technology - Rajasthan

26857750 supply of electrical material: 1 blanker (4 module) 2 choke ballast 28 watt 3 choke ballast 36 watt 4 electrical tape roll 5 led tube light 2 ft. 9 watt 6 led tube light 4’ 7 mcb 1 pole 16 a 8 mcb 1 pole 6 a 9 mcb 2 pole 32a 10 pvc modular plate (8x3) 8 module 11 socket 16 amp 12 socket 6 amp 13 switch 6 amp (one way) 14 top plug 16 amp 15 tube rod 36 watt 16 led bulb 4 watt 17 kwh meter 3 phase 4 wire base mtg. 10 60a make 18 kwh meter sp 5 30a (lcd display) 19 fan regulator modulator 20 time switch (road light timer) 21 water level controller (float switch) 22 brisk air fan 200 mm white 23 pvc saddle 32 mm 24 pvc saddle 10 mm 25 pvc saddle 25 mm for routine maintenance (housing)”....