Department Of Personnel And Training - Rajasthan

33719135 bids are invited for purchase and installation of various items for conference hall 1 sitc of digital chairman discussion unit with built in digital signal processing, unit with priority and next in line configuration, priority button silences all delegate microphones and allows only the chairperson to speak, next in line button gives the floor to the next speaker in a waiting list of speakers who requested to speak, user button with feedback, shielded microphone, immune to mobile phone interference, high quality integrated loudspeaker, gooseneck microphone of minimum length 400mm 500mm. headphone output with volume adjustment, loopthrough, daisy chain cabling, different led signalling for mic on / off or request to speak push button, audio quality 16bit digital, frequency response: 30hz 15khz.. 1 nos. 2 sitc of digital delegate discussion unit with built in digital signal processing, user button with feedback, shielded microphone, immune to mobile phone interference, high quality integrated loudspeaker, headphone output with volume adjustment, loop through, daisy chain cabling, different led signalling for mic on / off or request to speak push button, audio quality 16bit digital, frequency response: 30hz15khz.gooseneck microphone of minimum length 400mm 500mm. 44 nos. 3 sitc of digital central conference controller with recording & web server, conference controller with built in digital signal processing, control upto minimum 50 discussion unit and expandable upto 150 discussion unit by configuring master slave / power supply, controller unit with 4 bus connection. 4 branches. or 2 closed loop for redundancy mechanism, control & configure the controller via the integrated web server, two usb connections to connect usb storage device for direct recording of the meeting. the second usb storage device will take over automatically inscenaro the fist usb storage get full, camera control integration capability, controller with lcd display to implement several conference mode: direct access, request, push to talk, fifo, vox control, selectable voice activation, digital acoustic, feedback reduction, with audio input & output for connectivity with external sysytem like amplifier, microphone & audio / video conference system, audio quality 16bit digital, with power saving mode allows controller to sleep state if it has been left on, headphone port, 3 year standard oem warranty, certification: ce . 1 nos. 4 supply, installation, testing & commissoning of 3m bus cable to connect digital conference units. 46 nos. 5 supply, installation, testing & commissoning of 20m bus cable to connect digital conference units. 6 supply, installation, testing and commissioning of full range ip55 rated indoor / outdoor surface mounted music loudspeaker. the louspeaker shall meet the following performance criteria: usable frequency range ( 10db ) of 70hz to 19khz; power handling of 160 watt peak; nominal dispersion of 100° ( h ) × 100° ( v ) ; sensitivity of 87 db spl and max spl of 109 db spl peak; nominal impedence of 8 ohms and integral multi tap transformer with selectable tap settings of 5 / 10 / 20 / 40w@70v & 100v. the loudspeaker system shall be comprised of a 4.5 inch woofer; enclosed in engineered plastics and a powder coated tamperresistant steel grille. ul 1480 rated and en54 24 compliant for life safety / va applicatons. 6 nos. 7 supply, installation, testing and commissioning of intregrated high impedence class d dual zone amplifier with output power of 2 x 120 w @ 70 / 100 v ; frequency response 55 hz 20 khz ( +0 / 3 db, @ 1 w reference 1 khz ) ; thd+n ≤1 % ( at full rated power ) ; channel separation ( crosstalk ) ≤ 60 dbv ( below rated power, 1 khz ) ; a / d and d / a converters 24 bit / 48 khz; audio latency 10.4 ms ( any input to speaker output or aux output ) ; thd <0.3% at rated power. channel separation ≤ –60 dbv ( below rated power, 1 khz ) , dynamic range > 88 db. maximum input level : +10 dbv or better. 1 balanced page / priority input, 3 unbalanced line inputs; built in loudspaker eqs. shall include output for expansion amplifier and remote controller ( wired ) for source as well as volume control. 1 nos. 8 supply, installation, testing and commissioning of 17u equipment rack with power supply and fan. 1 nos. technical specifications for 10 kva on line ups system with battery back up 9 supply, installation, testing and commissioning of 10 kva online ups pure sinewave ( 10kw ) with 60 minutes battery backup, should work with 1ph 1ph and 3ph 1ph ( both ) , igbt based rectifier true online double conversion, new graphical lcd display. rackmount & tower convertible ( both ) , higher power density ( only 2u and <600mm depth for10k. double conversion efficiency upto 95%. wide input voltage window ( 110 – 275vac ) for indian environmental condition.inbuilt ovcd ( over voltage cut off device ) . active input power factor correction 0.99. unity output power factor. generator compatible with wide input voltage window, frequency range ( 40 hz 70 hz ) . total 4992vah or higher, digital charger technology provide 0 12 a charging current. adjustable battery no’s 16 to 20. 50 / 60 hz automatic frequency converter mode. winpower software support virtualization transfer application intelligent monitoring options, with battery racks & interconnecting cables etc as required.manufacture certifications ( documentary evidence to be furnished ) :qms: as per iso 9001: 2015, ems: as per iso 14001: 2015, occupational health & safety management system: as per iso 45001 : 2018 , quality management system tl 9000, nabl factory calibration lab of oem in india 10 supply, installation, testing and commissioning technology :inverter typ tonnage capacity , ton 2, star rating:3, btu / hr:24000, compressor :rotary, coil material : copper, refrigerant gas :r410a, rated power supply phase / volt / hz:1phase / 230volt / 50hz, air flow :850cfm, sound level ( idu ) :>30db to 52db, machine warranty :1 year, compressor warranty :5 year, iseer :3.50 total quantity : 1...

Department Of Personnel And Training - Rajasthan

33715549 supply installation testing commissioning of electrical and av items conference system various items for conference hall electrical work digital chairman discussion unit with built in digital signal processing, unit with priority and next in line configuration, priority button silences all delegate microphones and allows only the chairperson to speak, next in line button gives the floor to the next speaker in a waiting list of speakers who requested to speak, user button with feedback, shielded microphone, immune to mobile phone interference, high quality integrated loudspeaker,gooseneck microphone of minimum length 400mm 500mm. headphone output with volume adjustment, loop through, daisy chain cabling, different led signalling for mic on/off or request to speak push button, audio quality 16bit digital, frequency response: 30hz 15khz.. 1 nos. 2 sitc of digital delegate discussion unit with built in digital signal processing, user button with feedback, shielded microphone, immune to mobile phone interference, high quality integrated loudspeaker, headphone output with volume adjustment, loop through, daisy chain cabling, different led signalling for mic on/off or request to speak push button, audio quality 16bit digital, frequency response: 30hz 15khz.gooseneck microphone of minimum length 400mm 500mm. 44 nos. 3 sitc of digital central conference controller with recording & web server, conference controller with built in digital signal processing, control upto minimum 50 discussion unit and expandable upto 150 discussion unit by configuring master slave/power supply, controller unit with 4 bus connection. 4 branches. or 2 closed loop for redundancy mechanism, control & configure the controller via the integrated web server, two usb connections to connect usb storage device for direct recording of the meeting. the second usb storage device will take over automatically in scenaro the fist usb storage get full, camera control integration capability, controller with lcd display to implement several conference mode: direct access, request, push to talk, fifo, vox control, selectable voice activation, digital acoustic, feedback reduction, with audio input & output for connectivity with external sysytem like amplifier, microphone & audio/video conference system, audio quality 16bit digital, with power saving mode allows controller to sleep state if it has been left on, headphone port, 3 year standard oem warranty, certification: ce . 1 nos. 4 supply, installation, testing & commissoning of 3m bus cable to connect digital conference units. 46 nos. 5 supply, installation, testing & commissoning of 20m bus cable to connect digital conference units. 4 nos. 6 supply, installation, testing and commissioning of full range ip55 rated indoor/outdoor surface mounted music loudspeaker. the louspeaker shall meet the following performance criteria: usable frequency range ( 10db) of 70hz to 19khz; power handling of 160 watt peak; nominal dispersion of 100°(h) × 100°(v); sensitivity of 87 db spl and max spl of 109 db spl peak; nominal impedence of 8 ohms and integral multi tap transformer with selectable tap settings of 5/10/20/40w@70v & 100v. the loudspeaker system shall be comprised of a 4.5 inch woofer; enclosed in engineered plastics and a powder coated tamper resistant steel grille. ul 1480 rated and en54 24 compliant for life safety/va applicatons. 6 nos. 7 supply, installation, testing and commissioning of intregrated high impedence class d dual zone amplifier with output power of 2 x 120 w @ 70/100 v ; frequency response 55 hz 20 khz (+0/ 3 db, @ 1 w reference 1 khz) ; thd+n ≤1 % (at full rated power); channel separation (crosstalk) ≤ 60 dbv (below rated power, 1 khz); a/d and d/a converters 24 bit / 48 khz; audio latency 10.4 ms (any input to speaker output or aux output); thd <0.3% at rated power. channel separation ≤ –60 dbv (below rated power, 1 khz), dynamic range > 88 db. maximum input level : +10 dbv or better. 1 balanced page/priority input, 3 unbalanced line inputs; built in loudspaker eqs. shall include output for expansion amplifier and remote controller (wired) for source as well as volume control. 1 nos. 8 supply, installation, testing and commissioning of 17u equipment rack with power supply and fan. 1 nos. 9 supply, installation, testing and commissioning of 10 kva online ups pure sinewave (10kw) with 60 minutes battery backup, should work with 1ph 1ph and 3ph 1ph (both), igbt based rectifier true online double conversion, new graphical lcd display. rackmount & tower convertible (both), higher power density (only 2u and <600mm depth for10k. double conversion efficiency upto 95%. wide input voltage window (110 – 275vac) for indian environmental condition.inbuilt ovcd (over voltage cut off device). active input power factor correction 0.99. unity output power factor. generator compatible with wide input voltage window, frequency range (40 hz 70 hz). total 4992vah or higher, digital charger technology provide 0 12 a charging current. adjustable battery no’s 16 to 20. 50/60 hz automatic frequency converter mode. winpower software support virtualization transfer application intelligent monitoring options, with battery racks & interconnecting cables etc as required.manufacture certifications (documentary evidence to be furnished):qms: as per iso 9001: 2015,ems: as per iso 14001: 2015,occupational health & safety management system: as per iso 45001 : 2018 ,quality management system tl 9000,nabl factory calibration lab of oem in india 1 nos. 10 supply, installation, testing and commissioning technology :inverter typ tonnage capacity ,ton 2,star rating:3,btu/hr:24000,compressor :rotary,coil material : copper, refrigerant gas :r410a,rated power supply phase /volt/hz:1phase/230volt/50hz,air flow :850cfm, sound level(idu) :>30db to 52db,machine warranty :1 year,compressor warranty :5 year,iseer :3.50 8 nos. technical specifications for 10 kva on line ups system with battery back up technical specifications for inverter cassette air conditioner ...

North Western Railway - Rajasthan

32723667 supply of hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each.hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each.,hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each. carriage stores depot rajasthan 1037.00 kg ajmer , nwr division stores depot rajasthan 1383.00 kg...

Rajasthan Rajya Vidhyut Utpadan Nigam Limited - Rajasthan

32165886 extension 1. 730 (rvu2223glob00037) supply & etc of new 55 tr hvac system (2 nos.) with dismantling of existing systems 2. 731 (rvu2223gsob00038) supply of refrigerant gas mafron /freon (r 22/m 22) (10 nos. cylinders, 61 kg each cylinder) on returnable basis 3. 732 (rvu2223gsob00039) supply of c&i instruments for rgtpp, ramgarh 4. 733 (rvu2223gsob00040) supply of tubular level gauge (indicator) 5. 734 (rvu2223gsob00041) supply of plc card for air filter purge system and timer for air dryer 6. 736 (rvu2223gsob00044) supply of rtd for c&i system...

Rajasthan Rajya Vidhyut Utpadan Nigam Limited - Rajasthan

31762031 supply of refrigerant gas mafron / freon ( r 22 / m 22 ) ( 10 nos. cylinders, 61 kg each cylinder ) on returnable basis for central air conditioning system of stage i / ii and iii and administrative building at rgtpp, ramgarh....

Ministry Of Petroleum And Natural Gas - Rajasthan

31476205 bids are invited for custom bid for services total value incl gst for two years for services for control room and hvac op maint of mech pl elect inst telecom scada hr stores and finance jaipur under op and maint base nasirabad and finance at jaipur including night char.. , custom bid for services total value incl gst for 150 mandays on 12 hours basis of high skilled service crew supply during plantshutdown or pl pigging high skilled service crew without consumables for plantshutdown and pigging as per scc and sow , custom bid for services total value including gst for 1400 hours of highly skilled services on as when required basis as per scc and sow , custom bid for services total value including gst for 415 hours of skilled services on as when required basis as per scc and sow , custom bid for services total value including gst for 105 hours of semi skilled services on as when required basis as per scc and sow , custom bid for services total value including gst for total 200 quantity of refrigerant gas r22 or 410a or 134a including transporting storage and charging in equipment in contractor scope as per scc and sow , custom bid for services total value including gst for total 10 quantity for compressor compatible with existing make and model of any type of split ac voltas or godrage or carrier or blue star or hitachi or samsung etc as per scc and sow , custom bid for services total value including gst for total 20 quantity for fan or blower or motor compatible with existing make and model of any type of split ac voltas or godrage or carrier or blue star or hitachi or samsung etc as per scc and so.. , custom bid for services total value including gst for total 20 quantity for indoor or out door pcb card compatible with existing make and model of split ac with invertible voltas or godrage or carrier or blue star or hitachi or samsung etc as per s.. , custom bid for services total value including gst for total 10 quantity for condenser compatible with existing make and model of split ac with invertible voltas or godrage or carrier or blue star or hitachi or samsung etc as per scc and sow , custom bid for services total value including gst for total 10000 litre of dm water supply including transportation and testing report quality of dm water to supply as per scc and sow , custom bid for services total value including gst for total 460 cubic meter of nitrogen gas supply including transportation and testing report and installation in the cylinder bank as per scc and sow cylinder capacity 7 m3...

North Western Railway - Rajasthan

31368075 supply of r 32 refrigerant gas (eco friendlyr 32 refrigerant gas (eco friendly,r 32 refrigerant gas (eco friendly) for ac & fridge in cylinder., brand: stallion, fefron, fluoron. (cylinder will be returned to the firm after consumption) sse /electric /ac&p rajasthan 60.00 kg...

Rajasthan Rajya Vidyut Utpadan Nigam Limited - Rajasthan

30970982 tn mm 1649 refrigerants r 22,r 134a and r 410a supply of refrigerants r 22,r 134a and r 410a for air conditioning system at stps, suratgarh. , supply items: , hcfc refrigerant r 22 gas (chclf2); 99.8% pure as per is 5610/1983 with latest amendments in 61 kg packing cylinders , hfc refrigerant r 134a gas in 10kg packing cylinder iupac name:1,1,1,2 tetrafluroethane , eco friendly r 410 a refrigerant gas...

Indian Oil Corporation Limited - Rajasthan

30263186 bids are invited for pac unit 2 tr pac unit for server room (2tr nominal capacity @ min. 1100 cfm) , pac unit 1 tr pac unit for ups and battery room (1tr nominal capacity @ min. 600 cfm) , ict installation, commissioning & handing over of precision ac system. , accessories other accessories for installation , hot gas line hot gas line , liquid line liquid line , armoured copper cable interconnecting copper cabling between indoor & outdoor unitcopper piping shall be duly insulated with in the ac space. , copper cabling incoming copper cabling from incoming isolator to crac unit. , humidifier piping humidifier water piping with 25nb gi b class pipes. , outdoor stand outdoor stand , refrigerant refrigerant gas charge r 407 , cable tray cable tray for copper pipe laying , communication cable communication cable total quantity : 1...

Indian Oil Corporation Limited - Rajasthan

29897354 bids are invited for pac unit 2 tr pac unit for server room (2tr nominal capacity @ min. 1100 cfm) , pac unit 1 tr pac unit for ups and battery room (1tr nominal capacity @ min. 600 cfm) , ict installation, commissioning & handing over of precision ac system. , accessories other accessories for installation , hot gas line hot gas line , liquid line liquid line , armoured copper cable interconnecting copper cabling between indoor & outdoor unitcopper piping shall be duly insulated with in the ac space. , copper cabling incoming copper cabling from incoming isolator to crac unit. , humidifier piping humidifier water piping with 25nb gi b class pipes. , outdoor stand outdoor stand , refrigerant refrigerant gas charge r 407 , cable tray cable tray for copper pipe laying , communication cable communication cable total quantity : 1...

Military Engineer Services - Rajasthan

29883896 repair and maintenance of cooling towers, compressors and connected items of central ac plant at mh and ssa under ge jaipur 1.00 m&l for painting of 80tr central air conditioning plant equipments comprises of chiller, compressor, motors, pumps, lt panel refrigerant / water suction line, discharge lines of any specification with synthetic enamel paint of approved quality after preprations of surface including conceled fitments e.g., condenser, chiller, valves etc as per is colour code of central air conditioning plants including writing mes / sm no etc. complete all as specified and directed. 2.00 m&l for cleaning of condenser of 80 tr central ac plant by suitable chemical circulation and brushing of condenser tubes as required etc. complete all as specified and directed. 3.00 m&l for servicing of ahus cleaning cooling coils by non acidic chemical, cleaning of filters by suitable tools as required etc. complete all as specified and directed. 4.00 m&l for renewal of unserviceable mechanical oil seal of compressor at coupling end including testing and commissioning etc. complete all as specified and directed. note: gas / oil required to be changed after renewal of mechanical oil seal will be measured and paid separately in respective items of boq. 5.00 m&l for dismantling, opening, rewinding and refixing of, 3 phase, 440v, 50 hz induction motors capacity 3 to 7.5 hp with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechanical works for shaft / bearing housing , renewal of de and nde bearings, transportation from installation to workshop & back including connecting testing and commissioning at site for satisfactorily operation as required etc. complete all as specified and directed. 6.00 m&l for dismantling, opening, rewinding and refixing of, 3 phase, 440v, 50 hz induction motors capacity 10 hp with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechanical works for shaft / bearing housing , renewal of de and nde bearings, transportation from installation to workshop & back including connecting testing and commissioning at site for satisfactorily operation as required etc. complete all as specified and directed. 7.00 m&l for dismantling, opening, rewinding and refixing of, 3 phase, 440v, 50 hz induction motors capacity 12.5 to 20 hp with super enameled copper wire of existing gauge and existing class insulation including superior quality varnishing, heating / drying coils, making connections from coil to terminal box, spray painting with two coats of synthetic enamel paint, necessary mechanical works for shaft / bearing housing , renewal of de and nde bearings, transportation from installation to workshop & back including connecting testing and commissioning at site for satisfactorily operation as required etc. complete all as specified and directed. 8.00 m&l for dismantling and taking out defective monoblock pump of capacity 52 lps. make kirloskar from foundation and shifting to workshop for repair / replacement of impellers, bearings, seals etc. including refixing at foundation after repair testing and commissioning to the entire satisfaction etc. complete all as specified and directed. 9.00 m&l for dismantling and taking out defective centrifugal pump of capacity 123 cum / hr , make kirloskar from foundation and shifting to workshop for repair / replacement of impellers, bearings, seals etc, refixing at foundation after repair testing and commissioning complete to the entire satisfaction etc. complete all as specified and directed. 10.00 m&l for checking / repair / calibration of microm adjuster of compressor control panel, model vlrp single, type deluxe ( make softhard intelli sys ) etc. complete all as specified and directed. 11.00 s&f in repair microprocessor based controller of compressor control panel of 80 tr central ac plant with internal wiring and connections etc. complete all as specified and directed. make: voltas / softhard intelli / seimens. 12.00 m&l for replacement of pvc water tank heavy duty of capacity 5000 ltrs with ci strip ground around it to avoid bulging / deformation of tank as per existing including plumbing work etc. complete all as specified and directed. make sintex / polycon or equivalent in 13.00 m&l for refrigerant oil for compressor etc. complete all as specified and directed. make hpcl n 68 / indian oil servo friz / bpcl freezol 68. 14.00 s&f in repair contactor of lt panel of ac plant, mnx 18, ac supply, 230v, 50hz , 4 pole etc. complete all as specified and directed. make l&t / siemens / abb. 15.00 s&f in repair contactor of lt panel of ac plant, mnx 22, ac supply, 230v, 50hz , 3 pole etc. complete all as specified and directed. make l&t / siemens / abb 16.00 s&f in repair contactor of lt panel of ac plant, mnx 25, ac supply, 230v, 50hz , 3 pole etc. complete all as specified and directed. make l&t / siemens / abb 17.00 s&f in repair contactor of lt panel of ac plant, mnx 32, ac supply, 230v, 50hz , 3 pole etc. complete all as specified and directed. make l&t / siemens / abb 18.00 s&f in repair front mounting add on aux, contact block for contactor of lt panel of ac plant, mnx a1 or mnx a2, ac, 415v, 50 hz etc. complete all as specified and directed. make: l&t / siemens / abb 19.00 s&f in repair single phasing preventer of the lt panel of ac plant, 3 phase ac, 415 volt, 50 hz etc. complete all as specified and directed. make: l&t / minilec or equivalent in 20.00 s&f in repair mcb tp, 63 amps, ac, 10 ka, c series of the lt panel of ac plant etc. complete all as specified and directed. make legrand / schneider / hagar. 21.00 s&f in repair mcb tp, 40 amps, ac, 10 ka, c series of the lt panel of ac plant etc. complete all as specified and directed. make legrand / schneider / hagar. 22.00 s&f in repair contactor of compressor control panel ac, 415 v, 50 hz, 3 phase, model 3tf47 etc. complete all as specified and directed. make l&t / siemens / abb 23.00 s&f in repair contactor of compressor control panel, ac, 415 v, 50hz, 3 phases etc. complete all as specified and directed. model 3tf49. make l&t / siemens / abb. 24.00 s&f in repair thermal overload relay of range 9 15a, 14 23a, type direct mounting on mnx, for control panel etc. complete all as specified and directed. make l&t / siemens / bb. 25.00 s&f in repair contactor of compressor control panel, mnx 140, 3 phase ac, 415v, 50hz etc. complete all as specified and directed. make l&t / siemens / abb. 26.00 s&f in repair magnetic solenoid coil, 220 volts, ac supply as per existing etc. complete all as specified and directed. 27.00 s&f in repair transducer pt3 30 bar of compressor with harness as per existing etc. complete all as specified and directed. 28.00 s&f in repair digital timer of compressor control panel, time range 3 60 secs, 24 / 200 240v, 50hz as per existing etc. complete all as specified and directed. 29.00 m&l for filling of refrigerant gas r 22 for central ac plant in topping up during servicing / maintenance as required etc. complete all as specified and directed. 30.00 s&f in repair rubber coupling of motor and compressor as required etc. complete all as specified and directed. 31.00 s&f in repair v belts for ahu motors of existing size and type as required etc. complete all as specified and directed. 32.00 s&f in repair heating elements of 2.0 kw capacity of lengths from 1.5 to 2.5 ft as per site requirement etc. complete all as specified and directed. 33.00 s&f in repair heating elements of 3.0 kw capacity of lengths from 1.5 to 2.5 ft as per site requirement etc. complete all as specified and directed. 34.00 s&f in repair phase indicating lamps led type with the colour code as per existing etc. complete all as specified and directed. 35.00 s&f in repair water pressure indicating gauge fitted in water circulation circuit minimum range 0 to 7 kg / sqcm etc. complete all as specified and directed. make iebig / h guru / gluck. 36.00 s&f in repair water temperature gauge fitted in water circulation circuit minimum range 10 to 50 degree centigrade etc. complete all as specified and directed. make iebig / h guru / gluck 37.00 s&f in repair high flow hepa filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and eu 13, capacity 2000 cfm of size 610mm x 610mm x 305mm etc. complete all as specified and directed. make : thermadyne / puromatic / primide / dyna. 38.00 s&f in repair high flow hepa filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and eu 13, capacity 1000 cfm of size 610mm x 305mm x 305mm etc. complete all as specified and directed. make : thermadyne / puromatic / primide / dyna 39.00 s&f in repair high flow hepa filter, box type with aluminium frame, efficiency 99.97% down to 0.3 micron and eu 13 and of 1000 cfm of size 305mm x 610mmx305mm etc. complete all as specified and directed. make : thermadyne / puromatic / primide / dyna. 40.00 s&f in repair high flow hepa filter box type with aluminium frame, efficiency 99.97% down to 0.3 micron and eu 13 and of 500 cfm of size 305mm x 305mmx305mm etc. complete all as specified and directed. make : thermadyne / puromatic / primide / dyna. 41.00 s&f in repair fine fiter, flange type efficiency 99.00% down to 5.0 micron and eu 5 of size 610mmx610mm x305mm etc. complete all as specified and directed. make thermadyne / puromatic / primide / dyna. 42.00 s&f in repair fine filter, flange type, efficiency 99.00% down to 5.0 micron and eu 5 of size 305mm x 610mmx305mm etc. complete all as specified and directed. make thermadyne / puromatic / primide / dyana. 43.00 s&f in repair fine filter flange type, efficiency 99.00% down to 5.0 micron and eu 5 of size 610mmx 305mmx 305mm etc. complete all as specified and directed. make thermadyne / puromatic / primide / dyna. 44.00 s&f in repair fine filter flange type, efficiency 99.00% down to 5.0 micron and eu 5 of size 305mmx 305mm x305mm etc. complete all as specified and directed. make thermadyne / puromatic / primide / dyna. 45.00 s&f in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx610mmx50mm etc. complete all as specified and directed. make thermadyne / puromatic / primide / dyna. 46.00 s&f in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 610mmx305mmx50mm etc. complete all as specified and directed. make thermadyne / puromatic / primide / dyna. 47.00 s&f in repair pre filter aluminium box type epoxy filled, efficiency 90% down to 10 micron of size 305mmx305mmx50mm etc. complete all as specified and directed. make thermadyne / puromatic / primide / dyna. 48.00 s&f in repair hf type hrc cylindrical fuses of rating from 2a to 32a etc. complete all as specified and directed. make l&t / bch / havells. 49.00 s&f in repair hf type hrc cylindrical fuses of rating from 63a etc. complete all as specified and directed. make l&t / bch / havells. 50.00 s&f in repair hn type din fuse links of rating 200a etc. complete all as specified and directed. make l&t / bch / havells. 51.00 s&f in repair hn type din fuse links of rating 630a etc. complete all as specified and directed. make l&t / bch / havells. 52.00 repair and maint of 200tr capacity cooling tower including cleaning of cooling tower by removing scale and sludge formation, oiling & greasing of moving parts, replacement of pvc fills and other defective parts as required etc. complete all as specified and directed. ( note: parts replaced will be measured and paid separately under respective item of boq ) 53.00 s&f in repairs sprinkler head of size 6th with 4 blades and all accessories etc. complete all as specified and directed. 54.00 s&f in repairs pvc drift eliminator etc. complete all as specified and directed. 55.00 s&f in repairs pvc sprinkler pipe with end cap etc. complete all as specified and directed. 56.00 s&f in repairs tension devices viz. tie rod, turn buckle and clamp etc. complete all as specified and directed. 57.00 s&f in repairs pipe louver etc. complete all as specified and directed. 58.00 s&f in repairs pvc fills of cooling tower of size 600mm x 300mm x 150mm etc. complete all as specified and directed. 59.00 m&l earthing complete as per electrical plate no 3 of mes ssr part i with galvanised steel earth plate electrode 600 mmx600mmx6mm, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. earthing strip shall be protected by galvanised iron or steel pipe 40 mm bore light grade and connected to continuous earth wire on pole / test point. watering pipe shall be 20 mm bore gi medium grade. the earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel pcc pit and rcc cover complete all as specified & tested complete. note: ( i ) the concrete pit shall be made in pcc 1:2:4 type b o, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of rcc ( 1:2:4 ) , type b 1, using 20mm graded crushed stone aggregate with suitable ms handle in lieu of ci cover. reinforcement in cover shall be of 8mm dia tmt bars laid @150mm c / c both ways. ( ii ) quoted shall include the cost of 7.5 metre gi pipe for protection of earth wire. ( iii ) quoted shall include cost of 7.5 metre earth lead wire. ( iv ) earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides. 60.00 m&l for earthing with copper plate electrode 600 mm x 600 mm x 3.15 mm thick burried directly in ground ( earth pit not less than 2.25 metres deep below normal ground level ) with top edge of plate not less than 1.5 metre below normal ground level connected to copper earth strip 20x3 mm by means of steel bolts, nuts, check nuts and washers all as shown in electrical plate no 3 of mes schedule part i connected to earthing point and testing on completion with and including 15 mm bore light grade g.i. protection pipe ( upto 7.5 metre beyond outer edge of earth pit ) pcc pit in mix 1:3:6 type c1 with rcc 1:2:4 type b 1 40 mm thick cover reinforced with 6 mm dia m.s bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade g.i. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete. 61.00 supply only electrical insulating mat made of elastomeric polymers of size 1.0 m x 2.0 m x 2.0 mm, class a in blue colour confirming to is : 15652 of 2006 as approved etc. complete all as specified and directed. 62.00 supply, laying, connecting and testing of xlpe insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 240 sqmm, 3.5 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps / lugs / fixing arrangements etc. complete all as specified and directed. 63.00 supply, laying, connecting and testing of xlpe insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 185 sqmm, 3.5 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps / lugs / fixing arrangements etc. complete all as specified and directed. 64.00 supply, laying, connecting and testing of xlpe insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 120 sqmm, 3.5 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps / lugs / fixing arrangements etc. complete all as specified and directed. 65.00 supply, laying, connecting and testing of xlpe insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade cross sectional area 35 sqmm, 4 core from various panels upto their respective equipment on ground / floor / perforated trays with appropriate clamps / lugs / fixing arrangements etc. complete all as specified and directed. 66.00 m&l for dismantling of old ducting of any type and shape including all accessories viz. corner, cleat, carriage bolt, gasket etc. complete all as specified and directed. 67.00 supply , assembly and erection of gi sheet 24 gauge with c & ss rectangular / square duct made out of l shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc. complete all as specified and directed. 68.00 m&l for duct insulation with resin bonded fibre glass wool roll of density 24 kg / cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following: → ( a ) m&l for cleaning the duct surface ( to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. ( b ) m&l for applying rubber based adhesive cprx compound. ( c ) m&l for sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50 mm wide, to make the insulation leakproof. ( d ) m & l for securing the insulation with and including mechanically fastened nylon / steel straps of size 12 mm / 50 mm at maximum intervals of 1.2 mtr. etc. complete all as specified and directed. 69.00 schedule of credit total in figures...

Rajasthan State Mines And Minerals Limited - Rajasthan

29677784 supply installation testing and commissioning of rooftop packaged air conditioner supply installation testing and commissioning of rooftop packaged air conditioner , supply, installation, testing & commissioning of rooftop packaged air conditioner , rooftop packaged air conditioner of capacity 10 tons or above.mounting: rooftop, incoming power supply: 3 phase 415 vac / 50 hz, compressor: scroll type, operating range up to 52 deg c• supply, installation, testing and commissioning of complete system with all the parts / components on turnkey basis will be in supplier’s scope.• shifting of machines to site of installation shall also be carried out by the firm.• supply, installation and commissioning of required ducts will also be in suppliers scope.• onsite warrantee of 12 months. during onsite warrantee firm shall be responsible for keeping the machines operational, replacement of faulty parts, refrigerant gas filling etc. free of cost. all the maintenance works shall be carried out at our site only. all other specifications as per annexure i of tender...

Rajasthan Rajya Vidyut Utpadan Nigam Limited - Rajasthan

29346629 tn mm 1623 supply and etc of air cooled package ac unit (package air conditioner p.a.c.) of capacity 11 tr including all accessories and dismantling of the existing defective pacs stage i to iv and stps colony, suratgarh , requirement of air cooled package ac unit (package air conditioner p.a.c.) of capacity 11 tr (6 no. with opening and closing demper of required size),22 gauge galvanized sheet steel, rubber v.i. pad size 4”x4” & hard pvc drain pipes with hard copper refrigerant piping complete with fitting , size 1/2and 7/8) and nitrile sheet for insulation 9mm thick and erection testing, commissioning (etc) including dismantling of the existing defective pacs. (as per scope of work) , air cooled floor mounted ductable package unit capacity 11tr , sitc of hard pvc with 6mm insulation drain pipes fitting (32mm) , 22 gauge galvanized sheet steel size(1mtrx2.5mtr) , sitc of control cable single phase3 core 1.5 sq.mm copper , sitc ofhard copper refrigerant piping with nitrile insulation andfitting size ( 1/2and 7/8) , nitrile sheet for insulation 9mm thick , sitc of ms volume control damper , sub total(from 1.01 to 1.07) , total packing & forwarding charges(on 1.08) , sub total of suppy+p&f (including gst) , total freight , total insurance charges , other taxes/ charges(if any) , total supply amount (1.09 to 1.13) , etc ( as per scope of work) , etc of air cooled floor mounted ductable package unit capacity 11tr including fire retardant canvas connection, rubber pads, ms stand, refrigerant gas charging and lifting/ shifting of unit including dismantling of existing system( as per scope of work) , any other charges , total etc amount (2.01+2.02)...

North Western Railway - Rajasthan

28873230 supply of hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each.hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each., hfc refrigerant gas r 407 c in capacity of cylinder 45 kgs each. carriage stores depot rajasthan 1095.00 kg ajmer...

Department Of Police - Rajasthan

26598540 purchase and installation of duct able and other air conditioners for development centre in scrb , ductable air conditioners , duct able air conditioner ( 8 . 5 tr ) , duct able air conditioner ( 16 . 7 / 17 tr or more ) , air conditioners , hi wall split air conditioners ( 1 . 5 tr ) , hi wall split air conditioners ( 2 . 0 tr ) , installation of air conditioners , installation of duct able air conditioner ( installation , fixing , testing and commissioning of outdoor and indoor units including copper piping , installation of split air conditioner ( installation , fixing , testing and commissioning of outdoor and indoor units including copper piping , accessories and other items , m . s angle iron frames for condensing unit . , copper pipe 1 / 2 and 1 1 / 8 , refrigerant gas r 22 , copper pipe with nitrile rubber insulation sleeve , electrical cables interconnecting the indoor and outdoor units , drainpipe 6 mm thick nitrile rubber tube insulation complete with all necessary fittings such as elbows , tees , reducers etc . and support supports such as u clamps , civil work ( as per requirement ) , main db 1 ( 8 way spn db double door ) ( 8 . 25 kw ) , main db 2 ( 8 way tpn db double door ) ( 38 kw ) , main db 3 ( 6 way tpn db double door ) ( 42 kw ) , mcb spn ( single pole ) 32 amp , mcb tpn ( 4 pole ) 40 amp , mcb tpn 63 amp , mcb tpn 100 amp , dp mcb 2 pool 63 amp , main power cable ( 50 sq . mm x 4 core ) copper flexible electric cable ( 42 & 37 kw ) , main power cable ( 6 sq . mm x 4 core ) copper flexible electric cable ( 8 . 5 kw ) , outdoor to db cable ( 6 sq . mm x 4 core ) copper flexible electric cable , outdoor to db cable ( 4 sq . mm x 3 core ) copper flexible electric cable , any other unforseen expenditure...

Military Engineer Services - Rajasthan

26593505 repair and maintenance of summer cooling appliances and connected items at niwaru under ge ( south ) jaipur ceiling fan 2 supply only ball bearings/bush for ceiling fan of (1200/1400 mm) sweep. make: skf/ nbc 3 supply only ceiling fan downrod of size 12 inch to 24 inch or as per site requirement of material mild steel including clamp hook, rubber nut & bolt requiired for its proper mounting with ceiling.(note the mild steel downrod to be painted as per old u/s existing color with synthetic enamel paint) 4 re winding the burnt/short circuited winding for ceiling fan of (1200/1400 mm) sweep with same guage super enameled copper wire to maintain speed at load. 5 supply only in repairs of u/s capacitor from 2.15 to 3.15 mfd capacity for (600/1200/1400) mm sweep complete all as specified and directed. 6 s&f in repairs stepped type electronic fan regulator 240 v 50 hz,100 watts flush type (isi marked) on the existing phenolic laminated sheet etc complete all as specified and directed. 7 s&f in repairs modular type stepped electronic fan regulator 240 v 50 hz,100 watts modular type (isi marked) on the existing sheet etc complete all as specified and directed. make abb snieo or equivalent. 8 taking down the repairable exhaust fan of any size(300 / 450 mm) any make, single phase, 230 volts, 50 hz, ac after disconnecting electrically and mechanically incl transportation, dismantling, examine & carry out the repairs as required and brought back to site after servicing/repairing the exhaust fan by thoroughly cleaning the bearing/bush, shaft, stator, rotor & applying the lubricant / grease including one coat of super enameled varnish over the winding to improve the insulation value,re assembling, testing and refixing back to the site in all respect .note note “ spares required for replacement shall be measured and paid separately as supply only in respective items 9 supply only ball bearings/bush for exhaust fan of (300 / 450 mm). nmake : skf/nbc 10 re winding the burnt/shourt circuited winding for exhaust fan of (300 / 450 mm) with same cauge supper enameled copper wire to maintain speed at load. 11 supply and fix in repairs exhaust fan motor for (300/450) mm sweep of desired specifications (isi marked) to maintain current speed,air flow at load. 12 s&f in repairs blade of exhaust fan of size 300 mm sweep. 13 s&f in reapirs blade of exhaust fan of size 450mm sweep. 14 supply & fix in repairs louvers of appropriate size for exhaust fan of (300 / 450 mm) sweep. 15 supply & fix in repairs fasteners of appropriate size for exhaust fan of (300 / 450 mm) sweep. 16 supply & fix in repairs nut/bolts/screws of appropriate size for fixing loose exhaust fan of (300 / 450 mm) sweep. 17 fresh air fansnsupply & fix in repairs fresh air fans of size 200mm sweep of desired specifications(isi marked) for its smooth running at air flow load and all as directed by engr in charge. ( make: usha/bajaj/havells/crompton or equivalent) 18 supply & fix in repairs louvers of appropriate size for fresh air fans of size 200mm sweep and all as directed by engr in charge 19 desert coolerntaking down of desert cooler for repairs / servicing (3000/4000) cfm air flow capacity single phase 230 volts of any make after disconnecting electric/water connection drain out water and carry out minor repair work such as repairing of internal worn out wires, and for replacement of unserviceable parts such as motor, fan blade, lead wire and including testing complete all as specified and directed by engr in charge nnote “ spares required for replacement shall be measured and paid separately as supply only in respective items 20 re winding the burnt/shourt circuited winding for desert cooler (3000/4000) cfm air flow capacity single phase 230 volts of any make with same gauge super enameled copper wire to maintain speed at load. 21 supply only fan motor for desert cooler (3000/4000) cfm air flow capacity single phase 230 volts all as per existing one & all as directed by engr in charge. nmake: khaitan / summer king/shakti 22 supply only fan blade pvc/iron body with nut, bolt, washer for (3000/4000) cfm desert cooler of any make all as per existing one complete all as specified and directed by engr in charge nmake: khaitan / summer king/shakti 23 supply only flexible core pvc insulated with stranded copper conductor 70 / 0.0076 sqmm 3 core 600/1100 v isi marked all as directed.nmake : finolex,havells 24 supply and fix in repairs submersible vertical pump with suitable head for desert coolers (3000/4000) cfm air flow capacity single phase 230 volts & all as specified and directed by engr in charge. nmake: khaitan / summer king/shakti 25 supply & fix in repairs desert cooler fan regulator/selector switch for (3000/4000) cfm capacity of any make all as per existing one complete all as specified and directed by engr in chargen make: khaitan / summer king/shakti 26 supply and fix in repairs switch piano 5 amp single pole 230 volt 50 hz. nmake : anchor/kinjal/plaza / cona/ssk/ leader 27 s & f in reapirs plug top for desert cooler 3 pin 5 amps, 230 volt ac, isi marked complete all as specified and directed.nmake : anchor/plaza / cona/ssk/ leader 28 s&f in repair iron frame clamp as per existing one with required no. of nut & bolt to hold fan as well as motor of desert cooler all as specified and directed by engr in charge 29 supply and fix in repair front grill air divertor of pvc with selector switch for desert cooler 3000/4000 cum/hr 30 supply and fix in repair side panels(set of 3) made of ms sheet 2 mm thick for (3000/4000) cfm desert cooler. 31 supply & fix wooden shelving pad for desert cooler each set of three for 3000/4000 cfm & all as directed by engr in charge. 32 supply & fix in repairs pvc flexible pipe (from vertical pump to distributer and distributer to side shutter approx 2 mtr) 15mm dia for desert cooler including 3 way distributor junction tee set complete all as specified and directed by engr in charge. 33 water coolerndismantling/taking down of water cooler (40/80) ltr for repair such as fan motor,compressor and other minor rep & fixing works as in item no. 23.01 to 23.06 from any place any capacity, transported to workshop & back after repair and testing complete all as specified and directed n(i) spare parts required for replacement shall be measured separately under respective supply only items given here in after for item no. 23.01 t0 23.06n(ii) gas will be measured and paid separately. 34 supply only compressor ( sealed unit ) suitable for 40/80 ltr. water cooler make : blue stare/voltas/ushasriram 35 supply only fan motor 1/10 h.p single phase,230v for water cooler.n make : ge motors / air master 36 supply only thermostate for water cooler isi marked,complete all as specified and directed.n make : denfoss/indfos 37 supply only starting capacitor 60 to 80 mfd 230 volts, 50 hz. nmake : keltron / usha / siemens 38 supply only over load relay suitable for water cooler 40/80 ltr.nmake : sriram model sr 412/522 or equivalent of ae 39 supply only fan motor blade as per sample all as directed. 40 air conditioningndismantling/taking down air conditioner 1.5tr/2tr capacity window type from any place and install the ac at another location after proper repair and testing complete all as specified and directed. note: all works such as window cutting, drilling holes in wall and applying insulation coating on copper pipe are deemed to be included in this rate. n(repair work and replacement of damaged parts shall be measured and paid seperately). 41 all as per above item no 24.00. but for ac 1.5/2tr split type 42 servicing of 1.5tr/2tr capacity window type ac unit by cleaning with air pressure,tighting of bolts and nuts, arresting all leakages with necessary brazing/welding ensuring leak proof cleaning of condensor tubes ,checking of serviceability of fan motor,compressor,relay ,capacitors,pcb coli,control circuit remote,sensor indicator electric circuits etc. ,incl labour for replacing of unserviceable parts except compressor and changing of refrigerant gas complete all as specified and as directed by engr in charge. notes : n( i) replacement of compressor shall be measured and paid separatelyn( ii) spare parts required for replacement shall be measured separately under respective supply only items given here in after for item no. 26.01 & 32 to 36.n( iii) gas will be measured and paid separately. 43 supply only blower motor, single phase 230 volts 1500 rpm, suitable for window type ac 1.5 2 ton. make : aue / usha 44 all as per above item no 26.00 but for ac 1.5tr/2tr capacity split typennote : spare parts required for replacment shall be measured separately under respective supply only items given here in after for item no 27.01 & 32.00 to 37.00) 45 supply only blower motor, single phase 230 volts 1500 rpm, suitable for 1.5 2.0 tr split type air conditioner. make : aue / usha 46 m/l for disconnecting and removing u/s sealed compressor unit from 1.5 tr capacity window type ac including supply and connecting with original sealed compressor unit all as specified and as directed by engr in charge.n(make: carrier/voltas/blue star/usha daikin/lg/hitachi/godrej) 47 all as per above item no. 28.00 but for ac 2 tr capacity window type 48 all as per above item no. 28.00 but for ac 1.5tr capacity split type 49 all as per above item no. 28.00 but for ac 2 tr capacity split type 50 supply only running capacitor 45 to 50 mfd 230 volts, 50 hz for window/split ac. make : keltron / usha / siemens 51 supply only starting capacitor 100 to 120 mfd 230 volts, 50 hz for window/split ac. make : keltron / usha / siemens 52 supply only plastic filter as per existing makes for window/split type ac 1.5 2 ton capacity. 53 supply only over load protector relay suitable window/split type ac 1.5 2 ton capacity. make : sriram / ranutrol/ indfoss 54 supply only pcb coil suitable for window/split type ac 1.5/2.0 ton capacity complete all as directed..nmake : lg/carrier/blue star/voltas/fedder lloyd 55 m&l for gas freon 22(r22)/r 410a/ r32 all including filling of gas as directed by engr in charge.. 56 m&l for gas r 134a all including filling of gas as directed and checked by engr in charge. 57 replacement of u/s remote control with existing make for window/split type ac 1.5 2 ton capacity. 58 refrigeratornchecking of unservisable/ faulty refrigerator (180 to 320) ltr capacity installed in various locations for proper repair and testing of fan motor, thermostatic switch, over load protector relay, box type relay, evaporator coil assembly etc. complete all as specified and directed by engr in charge.n( i) replacement of compressor shall be measured and paid separatelyn( ii) spare parts required for replacement shall be measured separately under respective items as supply only given here in after (40.01 & 43 to 46)n( iii) gas will be measured and paid separately. 59 supply only fan motor with existing make for refrigerator of capacity (180 to 320) ltr all as specified and as directed by engineer in charge. 60 supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity (180 to 286) ltr all as specified and as directed by engineer in charge.n(make of compressor whirl pool / lg / godrej/samsung/voltas/hitachi) 61 supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity 320 ltr all as specified and as directed by engineer in charge.n(make of compressor whirl pool / lg / godrej/samsung/voltas/hitachi) 62 supply only in replacement of thermostatic switch with knob suitable for refrigerator.nmake : indfos / renutral 63 supply only in replacement of over load protector relay suitable for refrigerator of capacity ranging from 180 to 320 ltr all as directed by engr in charge.nmake : sriram / ranutrol/ indfossn n 64 supply only in replacement of box type relay suitable for refrigerator (180 to 320)ltr capacity engr in charge. make : sriram / ranutrol/ indfoss 65 supply only in replacement of evaporator coil assembly of existing make for refrigerator (180 to 320) ltr capacity engr in charge. 66 supply & fix in repairs of magnetic door gasket for refrigerator (180 to 320) ltr capacity engr in charge. 67 supply & fix in repairs of freezer door for refrigerator (180 to 320) ltr capacity engr in charge. make: e pack polymers. 68 voltage stabilisernre winding the burnt/short circuited winding for voltage stabilizer of 4/5kva rating capacity single phase 230 volts of any make with same gauge super enameled copper wire. 69 re winding the burnt/shourt circuited winding for voltage stabilizer of 2kva rating capacity single phase 230 volts of any make with same gauge super enameled copper wire. 70 re winding the burnt/short circuited winding for voltage stabilizer of 1kva rating capacity single phase 230 volts of any make with same gauge super enameled copper wire. 71 supply and replace unserviceable plug and socket board with metal plug and socket (1 phase+neutral & earth) with 20 amp rating dp mcb of make polycab with item code gpdps10004 in accordance with is 13032, is 8623, iec/bsen 61439 3. 72 supply and fix vegetable box for capacity 180 to 320 ltr refrigerator complete all as specified and directed by engr in charge. 73 supply and fix toughened glass for vegetable box for 180 to 320 ltr capacity refrigerator complete all as specified and directed. ( make: as per existing make and capacity of refrigerator) 74 supply and fix toughened glass bottle self of capacity 180 to 320 ltr capacity refrigerator complete all as specified and directed. ( make: as per existing make and capacity of refrigerator) 75 supply and fix lamp with holder/base plate and top toughened glass of capacity 180 to 320 ltr capacity refrigerator complete all as specified and directed. ( make: as per existing make and capacity of refrigerator) ...

North Western Railway - Rajasthan

26273843 supply of , hemitically sealed scroll compressor suitable for r 407c refrigerant gas, working on 415 v ac 50hz confirming to rdso spec no rdso / pe / spec / ac / 0061 / 2005 [ rev 1 ] or latest as per model no zr 61 kcetfd522 of m / s emerson make...

Rajasthan Rajya Vidyut Utpadan Nigam Limited - Rajasthan

25579803 supply of refrigerants r 22 r 134a and r 410a at stps suratgarh , supply items : , hcfc refrigerant r 22 gas ( chclf2 ) ; 99 . 8% pureas per is 5610/1983 with latest amendments in 61 kg packing cylinders , hfc refrigerant r 134a gas in 10kg packing cylinderiupac name:1 , 1 , 1 , 2 tetrafluroethane , ecofriendly r 410 a refrigerant gas...

Hindustan Copper Limited - Rajasthan

21870390 annual rate contract for servicing and maintenance of acs , refrigerators and water coolers installed at different locations at kcc as per nit , replacement of starting capacitor window/split ac having capacity 1 . 5t , replacement of credit cost of defective compressor complete etc for refrigeratot/water cooler required , rewinding of outdoor unit motor window/split ac having capacity 1 . 5t , replacement of cooling coil window/split ac having capacity 1 . 5t , replacement of credit cost of defective compressor complete etc as required window/split ac having capacity 1 . 5t , charging of refrigerant gas window/split ac having capacity 1 . 5t , servicing and overhauling of ac units like chemical servicing combing the coil , oiling , motor , tighting complete as required window/split ac having capacity 1 . 5t , replacement of fan blade for blower motor window/split ac having capacity 1 . 5t , replacement of credit cost of defective compressor complete etc for refrigerator required , replacement of running capacitor window/split ac having capacity 2t , replacement of condensor coil of window/split ac having capacity 2t , replacement of starting relay window/split ac having capacity 2t , replacement of starting capacitor window/split ac having capacity 2t , rewinding of indoor unit motor window/split ac having capacity 2t , rewinding of outdoor unit motor window/split ac having capacity 2t , replacement of cooling coil window/split ac having capacity 2t , replacement of credit cost of defective compressor complete etc as required window/split ac having capacity 2t , charging of refrigerant gas window/split ac having capacity 2t , servicing and overhauling of ac units like chemical servicing combing the coil , oiling , motor , tighting complete as required window/split ac having capacity 2t , replacement of fan blade for blower motor window/split ac having capacity 2t , replacement of running capacitor window/split ac having capacity 1 . 5t , replacement of condenser coil window/split ac having capacity 1 . 5t , replacement of starting relay window/split ac having capacity 1 . 5t , fan blade for blower motor of refrigeratot/water cooler , servicing and overhauling of refrigeratot/water cooler units like chemical servicing combing the coil , oiling , motor , tighting complete as required , charging of refrigent gas of refrigeratot/water cooler , replacement of capillary and stainer for refrigeratot/water cooler , repacement of starting relay for refrigeratot/water cooler , replacement of starting capacitor of refrigeratot/water cooler , rewinding of blower motor of refrigeratot/water cooler , replacement of olp of refrigeratot/water cooler , replacement of thermostat switch of refrigeratot/water cooler , rewinding of indoor unit motor window/split ac having capacity 1 . 5t...

Hindustan Copper Limited - Rajasthan

21607911 annual rate contract for servicing and maintenance of acs , refrigerators and water coolers installed at different locations at kcc as per nit , replacement of starting capacitor window/split ac having capacity 1 . 5t , replacement of credit cost of defective compressor complete etc for refrigeratot/water cooler required , rewinding of outdoor unit motor window/split ac having capacity 1 . 5t , replacement of cooling coil window/split ac having capacity 1 . 5t , replacement of credit cost of defective compressor complete etc as required window/split ac having capacity 1 . 5t , charging of refrigerant gas window/split ac having capacity 1 . 5t , servicing and overhauling of ac units like chemical servicing combing the coil , oiling , motor , tighting complete as required window/split ac having capacity 1 . 5t , replacement of fan blade for blower motor window/split ac having capacity 1 . 5t , replacement of credit cost of defective compressor complete etc for refrigerator required , replacement of running capacitor window/split ac having capacity 2t , replacement of condensor coil of window/split ac having capacity 2t , replacement of starting relay window/split ac having capacity 2t , replacement of starting capacitor window/split ac having capacity 2t , rewinding of indoor unit motor window/split ac having capacity 2t , rewinding of outdoor unit motor window/split ac having capacity 2t , replacement of cooling coil window/split ac having capacity 2t , replacement of credit cost of defective compressor complete etc as required window/split ac having capacity 2t , charging of refrigerant gas window/split ac having capacity 2t , servicing and overhauling of ac units like chemical servicing combing the coil , oiling , motor , tighting complete as required window/split ac having capacity 2t , replacement of fan blade for blower motor window/split ac having capacity 2t , replacement of running capacitor window/split ac having capacity 1 . 5t , replacement of condenser coil window/split ac having capacity 1 . 5t , replacement of starting relay window/split ac having capacity 1 . 5t , fan blade for blower motor of refrigeratot/water cooler , servicing and overhauling of refrigeratot/water cooler units like chemical servicing combing the coil , oiling , motor , tighting complete as required , charging of refrigent gas of refrigeratot/water cooler , replacement of capillary and stainer for refrigeratot/water cooler , repacement of starting relay for refrigeratot/water cooler , replacement of starting capacitor of refrigeratot/water cooler , rewinding of blower motor of refrigeratot/water cooler , replacement of olp of refrigeratot/water cooler , replacement of thermostat switch of refrigeratot/water cooler , rewinding of indoor unit motor window/split ac having capacity 1 . 5t...

Defence Research And Development Organisation - Rajasthan

21562674 tender for operation and maintenance of electrical and water supply installations including day to day maintenance at drdo complex and comprehensive maintenance of air conditioners at drdo guest house and otf at chandan range , operation and maintenance of electrical and water supply installations at drdo complex , chandan range by deploying 01 supervisor , 02 electricians cum dg operator , 01 plumber / fitter and 02 helpers as per the scope of work and inventory . , comprehensive annual service maintenance of the following air conditioners including the voltage stabilizers maintenance includes cost of replacing of minor components like filter pads , connectors , relays , gas charging pointing and control wires . a ) 1 . 5 ton split air conditioners 12 nos b ) 2 ton window air conditioners 24 nos , supply of the following replaceable spare parts at site at the rates quoted which shall be after considering the credit of old items etc . , excluding refrigerant . , gas filling r 22 kg , replacement of compressor for window air conditioner 1 . 5 ton to 2 ton . , replacement of compressor for split air conditioner 1 . 5 ton to 2 ton . , ...

Defence Research And Development Organisation - Rajasthan

21336416 tender for operation and maintenance of e / m and water supply installations including day to day maintenance to rcs facility ( nfdrf ) and maintenance of air conditioners installed at drdo guest house and officers transit and technical facility at dl jodhpur , tender for operation and maintenance of e / m and water supply installations including day to day maintenance to rcs facility ( nfdrf ) and maintenance of air conditioners installed at drdo guest house and officers transit and technical facility at dl jodhpur by deploying 01 electrician 01 plumber and 01 helper as per the scope of work and inventory mentioned at appendix a & b . , comprehensive annual service maintenance of the following split / window type air conditioners including voltage stabilizers by replacement of minor spare parts like thermostat , filter pads , contactors , capacitors , relays , pcb , control wiring complete all as per instructions of engineer in charge including pressure testing . a ) 1 . 5 ton window air conditioners 19 nos b ) 2 ton window air conditioners 6 nos c ) 1 . 5 ton window / split air conditioners 36 nos d ) 2 ton high wall split air conditioners 30 nos e ) 2 ton slim line split air conditioners 21 nos , supply of the following replaceable spare parts at site at the rates quoted which shall be after considering the credit of old items etc . , excluding refrigerant . , gas filling r 22 , replacement of compressor for window air conditioner 1 . 5 ton to 2 ton . , replacement of compressor for split air conditioner 1 . 5 ton to 2 ton . , ...

Defence Research And Development Organisation - Rajasthan

21323693 tender for operation and maintenance of electrical and water supply installations including day to day maintenance at drdo complex and comprehensive maintenance of air conditioners at drdo guest house and otf at chandan range , operation and maintenance of electrical and water supply installations at drdo complex , chandan range by deploying 01 supervisor , 02 electricians cum dg operator , 01 plumber / fitter and 02 helpers as per the scope of work and inventory . , comprehensive annual service maintenance of the following air conditioners including the voltage stabilizers maintenance includes cost of replacing of minor components like filter pads , connectors , relays , gas charging pointing and control wires . a ) 1 . 5 ton split air conditioners 12 nos b ) 2 ton window air conditioners 24 nos , supply of the following replaceable spare parts at site at the rates quoted which shall be after considering the credit of old items etc . , excluding refrigerant . , gas filling r 22 kg , replacement of compressor for window air conditioner 1 . 5 ton to 2 ton . , replacement of compressor for split air conditioner 1 . 5 ton to 2 ton . , ...