26593505
repair and maintenance of summer cooling appliances and connected items at niwaru under ge ( south ) jaipur ceiling fan 2 supply only ball bearings/bush for ceiling fan of (1200/1400 mm) sweep. make: skf/ nbc 3 supply only ceiling fan downrod of size 12 inch to 24 inch or as per site requirement of material mild steel including clamp hook, rubber nut & bolt requiired for its proper mounting with ceiling.(note the mild steel downrod to be painted as per old u/s existing color with synthetic enamel paint) 4 re winding the burnt/short circuited winding for ceiling fan of (1200/1400 mm) sweep with same guage super enameled copper wire to maintain speed at load. 5 supply only in repairs of u/s capacitor from 2.15 to 3.15 mfd capacity for (600/1200/1400) mm sweep complete all as specified and directed. 6 s&f in repairs stepped type electronic fan regulator 240 v 50 hz,100 watts flush type (isi marked) on the existing phenolic laminated sheet etc complete all as specified and directed. 7 s&f in repairs modular type stepped electronic fan regulator 240 v 50 hz,100 watts modular type (isi marked) on the existing sheet etc complete all as specified and directed. make abb snieo or equivalent. 8 taking down the repairable exhaust fan of any size(300 / 450 mm) any make, single phase, 230 volts, 50 hz, ac after disconnecting electrically and mechanically incl transportation, dismantling, examine & carry out the repairs as required and brought back to site after servicing/repairing the exhaust fan by thoroughly cleaning the bearing/bush, shaft, stator, rotor & applying the lubricant / grease including one coat of super enameled varnish over the winding to improve the insulation value,re assembling, testing and refixing back to the site in all respect .note note “ spares required for replacement shall be measured and paid separately as supply only in respective items 9 supply only ball bearings/bush for exhaust fan of (300 / 450 mm). nmake : skf/nbc 10 re winding the burnt/shourt circuited winding for exhaust fan of (300 / 450 mm) with same cauge supper enameled copper wire to maintain speed at load. 11 supply and fix in repairs exhaust fan motor for (300/450) mm sweep of desired specifications (isi marked) to maintain current speed,air flow at load. 12 s&f in repairs blade of exhaust fan of size 300 mm sweep. 13 s&f in reapirs blade of exhaust fan of size 450mm sweep. 14 supply & fix in repairs louvers of appropriate size for exhaust fan of (300 / 450 mm) sweep. 15 supply & fix in repairs fasteners of appropriate size for exhaust fan of (300 / 450 mm) sweep. 16 supply & fix in repairs nut/bolts/screws of appropriate size for fixing loose exhaust fan of (300 / 450 mm) sweep. 17 fresh air fansnsupply & fix in repairs fresh air fans of size 200mm sweep of desired specifications(isi marked) for its smooth running at air flow load and all as directed by engr in charge. ( make: usha/bajaj/havells/crompton or equivalent) 18 supply & fix in repairs louvers of appropriate size for fresh air fans of size 200mm sweep and all as directed by engr in charge 19 desert coolerntaking down of desert cooler for repairs / servicing (3000/4000) cfm air flow capacity single phase 230 volts of any make after disconnecting electric/water connection drain out water and carry out minor repair work such as repairing of internal worn out wires, and for replacement of unserviceable parts such as motor, fan blade, lead wire and including testing complete all as specified and directed by engr in charge nnote “ spares required for replacement shall be measured and paid separately as supply only in respective items 20 re winding the burnt/shourt circuited winding for desert cooler (3000/4000) cfm air flow capacity single phase 230 volts of any make with same gauge super enameled copper wire to maintain speed at load. 21 supply only fan motor for desert cooler (3000/4000) cfm air flow capacity single phase 230 volts all as per existing one & all as directed by engr in charge. nmake: khaitan / summer king/shakti 22 supply only fan blade pvc/iron body with nut, bolt, washer for (3000/4000) cfm desert cooler of any make all as per existing one complete all as specified and directed by engr in charge nmake: khaitan / summer king/shakti 23 supply only flexible core pvc insulated with stranded copper conductor 70 / 0.0076 sqmm 3 core 600/1100 v isi marked all as directed.nmake : finolex,havells 24 supply and fix in repairs submersible vertical pump with suitable head for desert coolers (3000/4000) cfm air flow capacity single phase 230 volts & all as specified and directed by engr in charge. nmake: khaitan / summer king/shakti 25 supply & fix in repairs desert cooler fan regulator/selector switch for (3000/4000) cfm capacity of any make all as per existing one complete all as specified and directed by engr in chargen make: khaitan / summer king/shakti 26 supply and fix in repairs switch piano 5 amp single pole 230 volt 50 hz. nmake : anchor/kinjal/plaza / cona/ssk/ leader 27 s & f in reapirs plug top for desert cooler 3 pin 5 amps, 230 volt ac, isi marked complete all as specified and directed.nmake : anchor/plaza / cona/ssk/ leader 28 s&f in repair iron frame clamp as per existing one with required no. of nut & bolt to hold fan as well as motor of desert cooler all as specified and directed by engr in charge 29 supply and fix in repair front grill air divertor of pvc with selector switch for desert cooler 3000/4000 cum/hr 30 supply and fix in repair side panels(set of 3) made of ms sheet 2 mm thick for (3000/4000) cfm desert cooler. 31 supply & fix wooden shelving pad for desert cooler each set of three for 3000/4000 cfm & all as directed by engr in charge. 32 supply & fix in repairs pvc flexible pipe (from vertical pump to distributer and distributer to side shutter approx 2 mtr) 15mm dia for desert cooler including 3 way distributor junction tee set complete all as specified and directed by engr in charge. 33 water coolerndismantling/taking down of water cooler (40/80) ltr for repair such as fan motor,compressor and other minor rep & fixing works as in item no. 23.01 to 23.06 from any place any capacity, transported to workshop & back after repair and testing complete all as specified and directed n(i) spare parts required for replacement shall be measured separately under respective supply only items given here in after for item no. 23.01 t0 23.06n(ii) gas will be measured and paid separately. 34 supply only compressor ( sealed unit ) suitable for 40/80 ltr. water cooler make : blue stare/voltas/ushasriram 35 supply only fan motor 1/10 h.p single phase,230v for water cooler.n make : ge motors / air master 36 supply only thermostate for water cooler isi marked,complete all as specified and directed.n make : denfoss/indfos 37 supply only starting capacitor 60 to 80 mfd 230 volts, 50 hz. nmake : keltron / usha / siemens 38 supply only over load relay suitable for water cooler 40/80 ltr.nmake : sriram model sr 412/522 or equivalent of ae 39 supply only fan motor blade as per sample all as directed. 40 air conditioningndismantling/taking down air conditioner 1.5tr/2tr capacity window type from any place and install the ac at another location after proper repair and testing complete all as specified and directed. note: all works such as window cutting, drilling holes in wall and applying insulation coating on copper pipe are deemed to be included in this rate. n(repair work and replacement of damaged parts shall be measured and paid seperately). 41 all as per above item no 24.00. but for ac 1.5/2tr split type 42 servicing of 1.5tr/2tr capacity window type ac unit by cleaning with air pressure,tighting of bolts and nuts, arresting all leakages with necessary brazing/welding ensuring leak proof cleaning of condensor tubes ,checking of serviceability of fan motor,compressor,relay ,capacitors,pcb coli,control circuit remote,sensor indicator electric circuits etc. ,incl labour for replacing of unserviceable parts except compressor and changing of refrigerant gas complete all as specified and as directed by engr in charge. notes : n( i) replacement of compressor shall be measured and paid separatelyn( ii) spare parts required for replacement shall be measured separately under respective supply only items given here in after for item no. 26.01 & 32 to 36.n( iii) gas will be measured and paid separately. 43 supply only blower motor, single phase 230 volts 1500 rpm, suitable for window type ac 1.5 2 ton. make : aue / usha 44 all as per above item no 26.00 but for ac 1.5tr/2tr capacity split typennote : spare parts required for replacment shall be measured separately under respective supply only items given here in after for item no 27.01 & 32.00 to 37.00) 45 supply only blower motor, single phase 230 volts 1500 rpm, suitable for 1.5 2.0 tr split type air conditioner. make : aue / usha 46 m/l for disconnecting and removing u/s sealed compressor unit from 1.5 tr capacity window type ac including supply and connecting with original sealed compressor unit all as specified and as directed by engr in charge.n(make: carrier/voltas/blue star/usha daikin/lg/hitachi/godrej) 47 all as per above item no. 28.00 but for ac 2 tr capacity window type 48 all as per above item no. 28.00 but for ac 1.5tr capacity split type 49 all as per above item no. 28.00 but for ac 2 tr capacity split type 50 supply only running capacitor 45 to 50 mfd 230 volts, 50 hz for window/split ac. make : keltron / usha / siemens 51 supply only starting capacitor 100 to 120 mfd 230 volts, 50 hz for window/split ac. make : keltron / usha / siemens 52 supply only plastic filter as per existing makes for window/split type ac 1.5 2 ton capacity. 53 supply only over load protector relay suitable window/split type ac 1.5 2 ton capacity. make : sriram / ranutrol/ indfoss 54 supply only pcb coil suitable for window/split type ac 1.5/2.0 ton capacity complete all as directed..nmake : lg/carrier/blue star/voltas/fedder lloyd 55 m&l for gas freon 22(r22)/r 410a/ r32 all including filling of gas as directed by engr in charge.. 56 m&l for gas r 134a all including filling of gas as directed and checked by engr in charge. 57 replacement of u/s remote control with existing make for window/split type ac 1.5 2 ton capacity. 58 refrigeratornchecking of unservisable/ faulty refrigerator (180 to 320) ltr capacity installed in various locations for proper repair and testing of fan motor, thermostatic switch, over load protector relay, box type relay, evaporator coil assembly etc. complete all as specified and directed by engr in charge.n( i) replacement of compressor shall be measured and paid separatelyn( ii) spare parts required for replacement shall be measured separately under respective items as supply only given here in after (40.01 & 43 to 46)n( iii) gas will be measured and paid separately. 59 supply only fan motor with existing make for refrigerator of capacity (180 to 320) ltr all as specified and as directed by engineer in charge. 60 supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity (180 to 286) ltr all as specified and as directed by engineer in charge.n(make of compressor whirl pool / lg / godrej/samsung/voltas/hitachi) 61 supply and fixing in repair of compressor (sealed unit) with relay suitable for refrigerator of capacity 320 ltr all as specified and as directed by engineer in charge.n(make of compressor whirl pool / lg / godrej/samsung/voltas/hitachi) 62 supply only in replacement of thermostatic switch with knob suitable for refrigerator.nmake : indfos / renutral 63 supply only in replacement of over load protector relay suitable for refrigerator of capacity ranging from 180 to 320 ltr all as directed by engr in charge.nmake : sriram / ranutrol/ indfossn n 64 supply only in replacement of box type relay suitable for refrigerator (180 to 320)ltr capacity engr in charge. make : sriram / ranutrol/ indfoss 65 supply only in replacement of evaporator coil assembly of existing make for refrigerator (180 to 320) ltr capacity engr in charge. 66 supply & fix in repairs of magnetic door gasket for refrigerator (180 to 320) ltr capacity engr in charge. 67 supply & fix in repairs of freezer door for refrigerator (180 to 320) ltr capacity engr in charge. make: e pack polymers. 68 voltage stabilisernre winding the burnt/short circuited winding for voltage stabilizer of 4/5kva rating capacity single phase 230 volts of any make with same gauge super enameled copper wire. 69 re winding the burnt/shourt circuited winding for voltage stabilizer of 2kva rating capacity single phase 230 volts of any make with same gauge super enameled copper wire. 70 re winding the burnt/short circuited winding for voltage stabilizer of 1kva rating capacity single phase 230 volts of any make with same gauge super enameled copper wire. 71 supply and replace unserviceable plug and socket board with metal plug and socket (1 phase+neutral & earth) with 20 amp rating dp mcb of make polycab with item code gpdps10004 in accordance with is 13032, is 8623, iec/bsen 61439 3. 72 supply and fix vegetable box for capacity 180 to 320 ltr refrigerator complete all as specified and directed by engr in charge. 73 supply and fix toughened glass for vegetable box for 180 to 320 ltr capacity refrigerator complete all as specified and directed. ( make: as per existing make and capacity of refrigerator) 74 supply and fix toughened glass bottle self of capacity 180 to 320 ltr capacity refrigerator complete all as specified and directed. ( make: as per existing make and capacity of refrigerator) 75 supply and fix lamp with holder/base plate and top toughened glass of capacity 180 to 320 ltr capacity refrigerator complete all as specified and directed. ( make: as per existing make and capacity of refrigerator) ...
Due Date : February 09, 2021
Tender Value : ₹ Ref. Documents