Department Of Local Bodies - Rajasthan

33898629 tender for indra gandhi city rojgar yojna kota nagar nigam south putai various goods supply work 2 supply of different varieties enamel paint ( is: 29321 1964, is: 133 1975 ) in municipal corporation kota south building as per direction of engineer in charge. 3 supply of different varieties paint remover in municipal corporation kota south building as per direction of engineer in charge. 4 supply of different varieties plastic emulsion paint ( is: 541 ) in municipal corporation kota south building as per direction of engineer in charge. 5 supply of different varieties water proofing cementpaint ( snowcem ) in municipal corporation kota south building as per direction of engineer in charge. 6 supply of different varieties primer ( cement primer ) in municipal corporation kota south building as per direction of engineer in charge. 7 supply of different varieties primer ( distemper primer ) in municipal corporation kota south building as per direction of engineer in charge. 8 supply ofbirla putty for different civil work in municipal corporation kota south building as per direction of engineer in charge....

Indian Army - Rajasthan

33852388 bids are invited for bricks , cement make ultra tech ambuja acc , aggregate , sand , kota stone 360mm x 360mm , plywood 8x4x12mm , channel 75mm x 40mm , ms angles 30x30x4mm , ms angles 50x50x5mm , ms flat , nut and bolts 50mm x 12mm , paint black make asian nerolac , turpentine oil , paint redoxide , plastic emulsion paint make asian nerolac , stainergreen 100 ml , stainer brown 100 ml , paint brush 4 inch ,welding rod 3.15mm x 350mm total quantity : 28542...

Department Of Local Bodies - Rajasthan

33754277 fasade painting work in shop and wall fasade painting in shop and wall in heritage look. art painting work on walls situated different places on municipal area sawai madhopur with after duly rubbing the surface to make the surface even and smooth. the work includes one coast of exterior primer coat of approved brand and three or more coat of exterior plastic emulsion paint of approved brand over the prepared surface, over tis rajasthani art / heritage painting work to be done as per direction & design patter approved by engineer incharge. the work includes the coast of all centering & shuttering scaffloding and cleaning the side properly after completion of work the work also includes the cost of all material man power, stencils etc. required for at painting ...

Indian Army - Rajasthan

33697279 bids are invited for terracotta emulsion paint color 10 l pack berger , erracotta emulsion paint white 10 l pack berger , paint brush 4 inch , white liquid thinner , terracotta emulsion paint color 4 lpack berger , black enamel paint asian , brown enamelpaint asian , white enamel paint asian 300ml pack total quantity : 22...

RAJASTHAN COUNCIL OF SCHOOL EDUCATION - Rajasthan

33524957 remaining work at gsss salari ( art and craft room ) block kekri district ajmer civil work 2 earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kind of soil 3 providing and laying in position cement concrete including curing compaction etc. complete in spcified grade excluding the cost of centering and shuttering all work upto plinth level 1:4:8(1 cement:4 coarse sand :8 graded stone aggregate 40 mm nominal size). 4 random rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in cement mortat 1:6 (1 cement: 6 sand) 5 centering & shuttering with plywood or steel sheets including strutting propping, bracing both ways and removal of formworksfor foundation in basements rafts , footings , straps beams , base of coloumns etc upto plinth level. 6 providing and laying in position specified grade of cement concrete for all rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints excluding the cost of centering, shuttering and reinforcement . m20 grade nominal mix (with graded stone agg. 20mm nominal size 7 filling available excavated earth (excluding rock)in trenches, plinth side of foundation etc. in layers not exceeding 20cm in depth consolidating each depositedby watering ramming inc. lead upto 50 mtr and with all lift supply and stacking good earth at site complete inc. loading unloading and transportation etc 8 random rubble dry stone kharanja under floor . 9 brickmasonaryinfoundation and plinth withbricks of class designation75 incement mortar 1:6(1 cement : 6 corase sand) add extra item no. 5.1 for brick work in super structure upto third storey.add extra over respective items all types of bricks for using clay fly ash bricks 10 centering & shuttering with plywood or steel sheets including strutting propping, bracing both ways with wooden members and removal of formworks upto floor three levelfor suspended floors, roofs, landing staircase balconies, girders, cantivlevers bands & bed plates anchor blocks sill, chajjas, lintel beams etc. 11 centering & shuttering with plywood or steel sheets including strutting propping, bracing both ways with wooden members and removal of formworks upto floor three level columns pillars posts and struts etc. 12 providing and laying in position specified grade of cement concerete for rcc structural elements upto floor three level inclu. curing, compaction, finishing with rendering in cement sand mortar 1:3 making good and joints exclu, cost of centering, shuttering and reinforcement for walls (any thickness) including attached pilasters butteresses plinth and string courses fillets columns pillars piers abutmnets post and struts (m20 gradenominal mix) 13 providing and laying in position specified grade of cement concerete for rcc structural elements upto floor three level inclu. curing, compaction, finishing with rendering in cement sand mortar 1:3 making good and joints exclu, cost of centering, shuttering and reinforcement (m20 grade nominal mix beams suspended floors roofs girders having slopes upto 15 degree landing balconies shelves chajja lintel bands plain window sill staircases and spiralstaircases 14 p/f reinforcement using steel of sail/vizak rinl /tata tiscon /essar/ zindal vijaynagar is:1786 1989 for rcc work inc. straightening cutting bending placing inposition and binding (inc. cost of binding wire ) all complete upto floor three level. thermo mechanicaly trated bars ( conforming of relevent is code) 15 plaster(internal)plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 12 mm thick. 16 plaster(external)plaster on new surface on wall in cement sand mortar 1:6 including ranking of joints etc. complete fine finished 20 mm thick 17 plaster(ceiling)plaster on new surface on wall in cement sand mortar 1:3 including ranking of joints etc. complete fine finished 6 mm thick. 18 polished blue kota stoneflooring skerting,laid over20 mm thick base of cement mortar 1:4 and jointed with grey cement slurry to match of the shade of the slab including rubbing and polishing complete for area of each slab upto 900 sq.cm.25mm thick. deduct for using kota stone other than blue in colour 19 polished blue kota stoneflooring skerting,laid over20 mm thick base of cement mortar 1:4 and jointed with grey cement slurry to match of the shade of the slab including rubbing and polishing complete for area of each slab from 2001 to 5000sq.cm.25mm thick slab.deduct for kota stone other than blue colour 20 s&f in walls machine cut &polished stone shelves ,tands and sills in cm1:3 with machine cut edge kota stone 25mm to 30 mm thick. 21 polished blue kota stone slab in steps, walls, pillars having fine machine cut edges laid on 12mm (av) thickcement mortar 1:3 and jointed with grey cement slurry mixed with pigment to match of the shade of the slab including rubbing and polishing complete for area of each slab from 2001 to 5000sq.cm.30 mm thick slab.stair 22 providing and fixing ms sheet single leaf doors shutter in angle iron frame 35x35x5mm suitabilly digonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engineer incharge but excluding cost of chowkhats including two coates of anti corrastie red oxide primer pant m.s. sheet 22 s.w.g. add 20 % extra for double leaf shutter. 23 providing and fixing t iron / angle iron frame for door and windows and ventilators or mild steel tee or angle section joined mitered and welded with 15 x 3 mm lugs, 10cm . long embedded in cement concrete blocks, 15 x 15 x 10 mm size of 1:3:6 (1 cement, 3 coursed sand and 6 graded stone aggregate 20 mm nominal size or with wooden plugs and screws or rawl plugs and screw or with fixing clips or with bolt and nuts as requesting including fixing of necessary butt hinges and screw and applying a priming coat of approved steel primer 24 providing and fixing steel glazed doors windows and ventilator shutters of standarad rolled steel section joints mitred and welded with lugs 13x3mm,10cm long embeded in cement concrete block 15x10x10cm of 1:3:6 or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with coper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approved steel primer, excluding the cost of metal beading and other fittings expect necessary hings of pivots steel handles peg stay etc.as required partly fixed and partly openable.(fixed area not to exeed 33%) 25 supplying & fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 26 providing and fixing square bars or other flat welded to window ventilators etc 27 panting on doors & windowspainting with ready mix paint of approved brand and manufacture in all shade to give an even shadenew steel work (2 or more coat ). 28 applying birla/jk cement based putty over cement plaster surface for making even surface 29 applying exterior emulsion paint like ace, apex or equivelent brand and manufacture of required shade to give an even shade inc. all scaffolding on prepared surface new work two or more coat 30 distempering with oil bound washable distemper of appd. brand and manufacture to give an even shade inc. all scaffolding new work (2 more caot) over and inc. scrapping and priming coat with cement primer. 31 grading for roof water proofing tratment with cement concreate 1:2:4 (1cement :2coarse sand :4 graded stone sggregate 20mm nominal size) with water proof compound as per manfacuture specification 32 providing batta (gola) 75 mm x 75 mm in cement concrete (1:2:4) including finishing with cement mortar 1:3 as per standard design. 33 p& f rigid pvc pipe (is 4985 mark) class 2nd /(4 kg /sqcm) approved quality / make including joining the pipe with solvant cement rubber ring and lubricant 110 mm dia. 34 s/f rough dressed stone sills, dasa, coping, cornices, sriwan, string courses in cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade 50mm thick 35 electric work 36 s & f follwing sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface/ recessed using saddles, clamps, fastener as required including cutting the wall covering conduit and making good the same as required. group 1 (25 mm dia) 37 p & f 18 swg m.s. recessed fan box, hexagonal/round of size 130mm dia, depth 75mm length, 12mm dia rod fan hook with 100 mm length extended on each side. group 1 38 wiring of light point/ fan point/exhaust fan point/ call bell point with 1.5 sq. mmnominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make in surface / recessed isi marked mms(is:9537 p 111) pvc conduit and its accessories , round tiles ,18 swg ms box with earth terminal, 6a switch, 3.0mm thick isi marked phenolic laminated sheet, zink plated /brass screws cup washer making connection testing etc. as required group 1 short point (up to 3 mtr.) 39 medium point (up to 6 mtr) 40 long point (up to 10 mtr) 41 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvcinsulated unsheathed flexible copper earth conductor 1.1 kv grade (is: 694) of approved make in surface/recessed isi marked mms (is:9537 p iii ) pvc conduit & its accessories 18swg 175mm x100 mm x 60 mm m.s box with earth terminal 6 a phenolic laminated sheet making cnnection testing etc. as requiredgroup 1 on board 42 supplying and drawi;ng fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface ofr necessed conduit/ casting capping including making connections etc. as required. group 1 2x2.5sqmm+1x1.5sqmm 43 p & f 240/415 v ac mcb of with positive isolation of breaking capacity not less than 10 k.a (b/c/d tripping characterstic) isi marked is 8828(1996)/conforming to iec 60898 in existing board/sheets including making conections testing etc. as required. group 16 a to 32 a rating 44 p & f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated coppers bus bars shorting link neutral link,earth link, and din bars masking sheet conforming to isi2032 & is8623 including making internal db terminators with copper lugs testing etc. as requireddouble door single phase 4 way group 3 45 p & f strip fluorscent tube fitting fabricated from (crca sheet and finished with powder coating/stove enamelled paint)/( extruded non corrosive uv resist ep channel)complete with accessories(low loss copperchoke, starter, starter seat)/electronic choke with terminal block duely prewired with copper conducter including making connection, testing etc. as required(without tube) 1x36watts with eb gr. 1 46 p & f fluorscent tube rod in existing fixtures as required, ,36/40 watts group 1 47 p & f star rated double ball beari;ng capacitor start, aluminium bodyand blade ceiling fan with down rod upto 30 cm with 3x1.5 sqmm pvc insulated flexible copper conductor making connection testing etc as required. 1200mm sweep 5star rated group 1 48 p&f socketrsize flush type 120/280 watt rotary 5 step fan regulator including making conenction testing etc. as required 49 p & f 18 swg sheet steel boxes duly finisded with two coats of red oxide and with earthing terminal of following sizes (nominal size) on surfacae or in recessed as required. 175mmx 100mmx60mm 50 p/f pvc sheet of size 75mm dia inc. screw cup washer as required 51 p/laying p.v.c sheathed cable of 1.1 kv grade with aluminium conductor fo is:1554 p 1/is:7098 p 1 fo approved make in ground as per is:1255 including excavation fo 30cmx75cm size trench 25 cm thick under layer of sand iind class bricks covering refilling earth compaction of earth making necessary connection testing etc. as required of size 4.0 sq mm, 2 core ...

Department Of Local Bodies - Rajasthan

33263374 various construction work under camp abhiyan prasasan sahro ke sang aayojit shivir abiyan ke tahat nirman se sambandit vibin karya and rajsthan sampark portal complains work in ward 1 to 4, 6 to 11, 68 to 70. arc ( carriage of materials by mechanical transport including loading, unloading and stacking ::earth upto5km 2 dismantling stone masonry.rubble stone masonry in cement mortar. 3 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer incharge.in cement mortar 4 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 5 earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of engineer for following depths, below natural ground / road top level.in all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.depth upto 1.5 m 6 providing and fixing stone slab covering of required size over drains including filling of joints with cement sand mortar 1:3 complete as per direction of engineer in charge.average thickness 60 to 75 mm 7 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level :1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate 40 mm nominal size) 8 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 9 centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :foundations, footings, bases of columns, etc. for mass concrete. 10 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement all work upto plinth level :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 11 reinforcement for r.c.c. work at all levels including straightening,cutting, bending, placing in position and binding all complete.cold twisted bars 12 brick work with modular bricks of class designation 75 in foundation and plinth in:cement mortar 1:6 (1 cement : 6 coarse sand). 13 half brick masonry with fps bricks of class designation 75 in superstructure above plinth level upto two stories.cement mortar 1:4 (1 cement :4 coarse sand) 14 random rubble masonry with hard stone in foundation and plinth :cement mortar 1:6 (1 cement : 6 coarse sand) 15 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 16 providing and fixing 1st quality mat finished ceremic tile size 300x300 mm confirming to is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 17 providing & fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade :sal wood 18 providing and fixing fully panelled/partly panelled/ double leaf shutter frame for doors as per approved design and drawings with approved ordinary c.p./ oxidised steel fittings as per annexure a and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :35 mm thick.nigeria wood grade i 19 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesin in glue both sides including approved isi marked stainless steel butt hinges fittings with necessary screws complete as per annexure a :25 mm thick.decorative teak veneer both side 20 steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 21 providing and fixing gi wire gauge of average width of aperture 1.56mm with wire of 0.45mm to existing steel door, window shutter frames with necessary m.s. strip beading 20x3mm with suitable screw at not exceeding 150mm distance etc. complete. 22 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.using m.s. angels 40x40x6 mm for diagonal braces. 23 providing and fixing factory made isi marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazingclips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design. 24 random rubble dry stone kharanja (soling) under floor. 25 providing and fixing on wall face unplasticised rigid pvc single socketed pipes rain water pipes conforming to is : 13592 type a including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion.75 mm diameter 26 110 mm diameter 27 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion.coupler75 mm 28 110 mm 29 single tee with door75x75x75 mm 30 110x110x110 mm 31 single tee without door.75x75x75 mm 32 110x110x110 mm 33 bend 87.5°75 mm bend 34 110 mm bend 35 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of50x50x50mm hard wood plugs, screwed with m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete.75 mm 36 110 mm 37 cement plastering including t&p, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :1:6 (1 cement : 6 fine/ coarse sand) 38 neat cement punning 39 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.new work (two or more coats) over and including priming coat with cement primer. 40 finishing walls with water proofing cement paint of required shade :new work (two or more coats applied @ 3.84 kg/10 sqm). 41 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:two or more coats on new work 42 painting with synthetic enamel paint of approved brand and manufacture to give an even shade :two or more coats on new work 43 repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead :with cement mortar 1:4 (1 cement : 4 fine sand) 44 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 45 finishing walls with water proofing cement paint of required shade :old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of priming coat. 46 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge.internal work exposed on wall.15 mm nominal outer dia .pipes. 47 25 mm nominal outer dia .pipes. 48 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.concealed work including cutting chases and making good the walls etc.,15 mm nominal outer dia .pipes. 49 25 mm nominal outer dia .pipes. 50 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings. this included jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.external work.15 mm nominal outer dia .pipes. 51 25 mm nominal outer dia .pipes. 52 providing and fixing brass bib cock of approved quality :15 mm nominal bore 53 providing and fixing brass stop cock of approved quality :15 mm nominal bore 54 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete :25 mm nominal bore 55 providing and fixing gun metal non return valve of approved quality (screwed end) :25 mm nominal bore.horizontal 56 providing and placing on terrace (at all floor levels) polyethylene water storage tank isi : 12701 marked with cover and suitablelocking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 57 supplying and fixing c.i. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg. 58 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete.flexible pipe.40 mm dia 59 providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:with average thickness of 120mm and minimum thickness at khurra as 65 mm. 60 earth work for sewer line and manhole in excavation in foundation, trenches manholes, road side chambers etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of engineer for following depths, below natural ground / road top level including allowances for any additional excavation beyond the drawings (measurement for payment to be as per standard drawings), re handling of material/earth to complete the task.in all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. depth upto 1.5 m 61 dismantling of flexible pavements for sewer line and manholes and disposal of dismantled materials up to a lead of 50 metres as directed by engineer including allowances for any additional dismantling beyond the drawings (measurement for payment to be as per standard drawings), re handling of material/earth to complete the task.bituminous courses 62 granular courses 63 dismantling of cement concrete pavement for sewer line and manholes by mechanical means using pneumatic tools, cutting the peripheral edge by cc cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres including allowances for any additional dismantling beyond the drawings (measurement for payment to be as per standard drawings), rehandling of material/earth to complete the task. 64 providing and laying in position cement concrete 1:3:6 (1 cement : 1 graded stone aggregate 20 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration under sewer line and manhole workincluding allowances for any additional road restoration beyond the drawings (measurement for payment to be as per standard drawings) to complete the task 65 providing at site, lowering & laying in trenches, aligning & jointing of u pvc pipe as per is 13592 (amended up to date) and as per specifications with rubber rings with socket and spigot joint, (epdm/sbr) for all depths for pipe length as per drawing and specification including hydraulic field testing (including the cost and conveyance of water to site for testing) and commissioning etc complete as directed by engineer for house sewer connection work. note : e/w to be measured and paid separately. length of pipe shall be measured in between the outer wall of two manholes / inspection chambers. pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/ inspection chamber shall not be payable. 66 providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths full round hdpe dwc (double wall corrugated) pipes of sn8 grade as per is 16098 (part 2) amended upto date in trenches in complete including all material, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per technical specifications ,drawings and as per direction of engineer. note : e/w to be measured and paid separately. length of pipe shall be measured in between the outer wall of two manholes / inspection chambers. pipe in the manhole/inspection chamber’s wall shall deemed to be included in the item of manhole/inspection chamber shall not be payable.200 mm id 67 providing, fixing and constructing of pre cast rcc m 40 grade circular manholes with internal dia 1.0m and up to specified depth having pre cast rcc m 40 grade circular manhole cover frame (id 0.56m, od 0.92m), conical piece (top id 0.56m, bottom id 1.0m, vertical height 0.805m, wall thickness 125mm), and circular rings of required heights (id 1.0m, height 150/225/300/600 mm, wall thickness 125mm) below conical piece as per required depth of manhole and having steel reinforcement in conical piece @ not less than 80 kg per cum of concrete, including cast in situ pcc m 10 grade (1:3:6) foundation of 1.625m dia and 150mm thickness, pcc m15 grade circular wall id 0.925m, wall thickness 200mm, height equal to id of sewer pipe + one wall thickness of pipe + 50 mm (to flush the manhole frame with road top, height of wall can be increased but not more than 100mm), pcc m15 grade benching and channel portion and up to top level of sewer pipe etc complete with curing compaction and form work, supplying and fixing heavy duty sfrc manhole cover as per is 12592 (part i and ii), supplying and fixing plastic encapsulated ci/ms foot steps / sfrc foot steps, including cost of shuttering, steel reinforcement, testing for water tightness etc. complete in all respect as per drawing, as per specification and the direction of the engineer. note: excavation of earth work and road cutting for manhole will be measured and paid separately.pre cast rcc m 40 grade circular manhole conical piece with inbuilt cover and frame (height 0.805), cast in situ pcc m 10 grade foundation, pcc m15 grade circular wall id 0.925m, wall thickness 200mm, wall height equal to id of sewer pipe + one wall thickness of pipe + 50 mm, pcc m15 grade benching and channel portion. depth of manhole shall be measured from top of manhole cover upto lowest invert of pipe. (depth includes in the item = height of conical piece + id of sewer pipe + 1 wall thickness of pipe + 50mm) 68 providing and fixing pre cast rcc m 40 grade circular ring of id1.0m, wall thickness 125mm, height 150/225/300/600 mm forconstructing extra depth of manhole beyond depth mentioned in itemno 17.59.1 as per drawing. 69 constructing providing and fixing of pre cast rcc m 40 grade circular road side inspection chamber including earthwork using sulphate resistant cement with following dia and depth cylindrical piece with 100mm wall thickness, 100mm base slab, inbuilt cover & frame on top, provision for 110mm od in and out sewer connection with making proper in built benching and channel with pcc m 15 grade including providing cast in situ 100mm thick foundation of pcc m 10 grade, supplying and fixing circular precast sfrc circular 300 mm dia manhole cover with frame m.d. 10, including steel reinforcement minimum @ 80kg/cum, testing for water tightness complete in all respect as per drawing, specification and the direction of the engineer. 17.63.2 pre cast road side inspection chamber of 450mm dia (internal), 600mm depth and 750mm dia base foundation. 70 providing and making connection to the manhole/ road side chamber/ property chamber by cutting hole in wall, making good the same with brick work/ stone masonry work in cement mortar 1:4, plaster in cement mortar 1:3, encasement of pipe at manhole with 75mm thick m15 grade concrete etc complete as directed byengineer. 71 raising circular inspection chamber with circular cover 450mm dia and frame slab to required level including dismantling existing slab, taking out the existing ci frame & cover of inspection chamber and raising it upto ground/ road level, refixing of frame and cover in m15 (1:2:4) concrete all around the frame, including making good thedamage, form work, curing, complete as directed by engineer. (brick/ concrete work of raising depth of manhole to be paid separately) 72 raising precast circular manhole cover and frame by taking out existing precast frame and cover, providing and fixing precast sfrc circular spacer of required height, re fixing existing manhole cover frame and cover with cement sand mortar (1:3), including making good the damage, complete as directed by engineer. 73 lowering of circular brick / rr stone masonry manhole with circular opening 560mm dia and frame slab to required level including dismantling existing slab and manhole wall, taking out the existing ci frame & cover of manhole and lowering it upto ground/ road level, refixing of frame and cover in m15 (1:2:4) concrete all around the frame, including making good the damage, form work, curing, complete as directed by engineer. (dismantling of brick work / rr stone work depth of manhole to be paid separately) 74 lowering of circular inspection chamber with circular cover 450mm dia and frame slab to required level including dismantling existing slab and inspection chamber wall, taking out the existing ci frame & cover of inspection chamber and lowering it upto ground/ road level, refixing of frame and cover in m15 (1:2:4) concrete all around the frame, including making good the damage, form work, curing, complete as directed by engineer. (dismantling of brick/ concrete work depth of manhole to be paid separately) 75 supplying & fixing 560mm dia sfrc manhole frame & cover as per is : 12592 2002 in existing manholes including grouting the frame in pcc m 15 complete in all respect as directed by the engineer.hd 20 76 cleaning and flow test of rcc/sw pipes already laid but not commissioned (including cost and conveyance of water to site) complete in all respect as per direction of engineer in charge. 200 mm dia 77 constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast r.c.c. horizontal . grating with frame complete as per standard design : with bricks 78 providing and fixing of reinforced ferro cement drain covers designed for a class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted m.s. plate , rim and m.s. lifting hooks, admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc.standard size 1000x800mm (100mm thick) for span 451 to 700mm 79 standard size 1500x600mm (125mm thick) for span 701 to 1200mm 80 providing and fixing of reinforced ferro cement drain covers designed for aa class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted m.s. plate , rim and m.s. lifting hooks, admixtures like plasticizer, bond improving compound,shrinkage, resistance compound, abrasion resistant complete as per approved design etc.standard size 1000x800mm (100mm thick) for span 451 to 700mm 81 standard size 1500x600mm (125mm thick) for span 701 to 1200mm ...

Public Works Department - Rajasthan

33121873 construction of civil work for vrdl at medical college kota taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead: of area 3 square meter and below. 2 taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead: of area exceeding 3 square meter. 3 halfflyash lime gypsum brick worksin superstructure , above plinth level upto floor threelevelusing flyash bricks of designation 75cement mortar 1 : 4 (1 cement : 4 coarse sand) 4 flyash lime gypsum brick works withflyash lime gypsum brick works of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in : cement mortar 1 : 6 (1 cement : 6 coarse sand) 5 p & f 1st qualityheavy duty vitrified polished digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. size 600mm x 600mm 6 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. in cement mortar. 7 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). for fixed portionpowder coating aluminum( minimum thickness of powder coating 50 micron) 8 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).powder coating aluminum( minimum thickness of powder coating 50 micron) 9 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 10 providing and fixing horizontal blinds /venation blindshall be cold rolled formed u shape 23 mm high x 25 mm wide with flanged adages. it shall be made of heavy gaze 0.56 mm galvanized steel, slates shall be made of virgin al. alloy (having 3.5 – 4.5% of mg. content of width 25 mm. the slat shall have dust guard paint coating, the cord lock shall be of thick tomized steel and shall be securely attach in the head rail. it shall provide locking arrangement of the cord. tilt rod shall be made of galvanized steel it shall have a d shaped with an average cross section with diameter of 6 mm to achieve minimum torsional deflection. 11 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 12 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 13 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. new work 14 providing and fixing double action hydraulic floor spring of approved brand and manufacture is : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece m.s.with stainless steel cover plate 15 providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge.(cost of aluminium snap beading shall be paid in basicitem.) with glass panes of 5.0 mm thickness (weight not less than 13.75 kg./sqm) as per is : 2835. 16 providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, y and h aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.powder coating aluminum( minimum thickness of powder coating 50 micron) 17 providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade i, type ii conforming to is : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with c.p. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer in charge. prelaminated particle board with decorative lamination on both sides. 18 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of :south (red / choclate colour) above 3601 cm2 slabs 19 providing and fixing aluminium composite panel ofapproved make 3mm thick with 0.5mm thick skin & pvdf coated approved shade for wall panelling. main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. stainless steel screw to be used to fix the acp panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in all respect as approved by engineer in charge. 20 providing & applying three coat of pure acrylic water based elastomeric brush applied insulating coatingon exterior surface overwaterproofing slurry coat , initial coat of 50 75 micron thickness with diluting 1 part of chemicalwith 2 parts of clean water, over which applying 2 coats at 2 hrs, intervals each with diluting 1 part of chemical with 10% of clean water for total thickness of 400 to 450 microns (covering area 0.9 sq.m/kg of chemical) including preparation of surface by cleaning, brushing and dust removing, scaffolding if necessary etc., with contractors labour, tools,machinery etc, complete as directed by engineer in charge. 21 providing and filling block rubberized joint filler in all visible cracks of masonry / concrete / terrace concrete blocks / canal lining basement / a.c. / g.i. / sheets roofs gutters down pipes after removing existing treatment and cleaning with wire brush and joint should be free frome dust, loose particle, oil and grease than filling joints with filler putty knife spatula or brook knife and let it dry for atleast 72 hours complete (as per manufacturer specifications). 22 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor three level excluding the cost of centering and shuttering. m15 grade nominal mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 23 providing and fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture as per direction of engineer in charge of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm) consisting of main ‘t’ runner suitably spaced at joints to get required length and size of 24x38mm made from 0.33 mm thick (minimum) sheet, 1200mm centre to centre, and cross‘t’ of size 24x32mm made out of 0.33mm (minimum) sheet, 1200mm long spaced between main ‘t’ at 600mm centre to centre to form a grid of 1200x600mm and secondary cross ’t’ of length 600mm and size 24x32mm made out of 0.33 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle pre coated steel of size (24x24x3000mm made of 0.40mm thick (minimum) sheet with the help of rawlplugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick densified edged calcium silicate ceiling tiles of approved texture in the grid including cutting /making opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc., wherever required, main ‘t’ runners to be suspended from ceiling using 50 mm long m 6 dash fasteners, 6mm g.i. fully threaded rods with galvnised steel l cleat level adjusters of size 80x25x2mm, spaced at 1200mm centre to centre long main ‘t’ bottom exposed with 24mm of all t sections shall be pre painted with polyster baked paint, for all heights, as per specifications, drawing and as directed by engineer in charge. note : only calcium silicate false ceiling area will be measured from wall to wall. nodeduction shall be made for exposed frames/opening (cut outs)having area less than 0.30 sqm.the calcium silicate ceiling tiles shall have nrc. value 0.50 (minimum), light reflection> 85% non combustible as per b.s. 476 part iv, 100% humidity resistance and also having thermal conductivity <= 0.043 w/m0kc. 24 providing and fixing cushion vinyl/fully flexible vinyl flooring confirming to i.s. 3462 flooring of approved make with fibre base using rubber base adhesives including rolling with light wooden roller complete : 2.0 mm thick. 25 dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: 26 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 27 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 28 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor three level excluding the cost of centering and shuttering. m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 29 providing and fixing factory made p.v.c. door frame of size 50x47mm with a wall thickness of5mm, made out of extruded 5mm rigid pvc foam sheet mitred at corners and joined with 2 nos. of 150mm long brackets of 15x15mm m.s. square tube, the vertical door profiles to be reinforced with 19x19mm m.s. square tube of 19 gauge, epdm rubber gasket weather seal to be provided through out the frame. the door frame to be fixed to the wall using m.s. screws of 65/100mm size complete as per manufacturers specification and direction of engineer in charge. 30 providing and fixing to existing door frames.30mm thick factory made solid panel pvc door shutter consisting of frame made out of m.s. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles and 15 mm x15mm , top & bottom rails. m.s .frame shall have a coat of steel primers of approved make and manufacture m.s. frame covered with 5mm thick heat moulded pvc ‘c channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on either side forming stiles; and 5mm thick, 95mm wide pvc sheet out of which 75 mm shall be flat and 20mm shall be tapered in 45 degreeon the inner side to form top and bottom rail and 115mm wide pvc sheet out of which 75 mm shall be flat and 20mm shall be tapered on both sides to form lock rail. top bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2) thick, 20mm wide cross pvc sheet shall be provided as gap insert for top rail & bottom rail. panelling of 5mm thick pvc sheet to be fitted in the m.s. frame welded/ sealed to the stiles & rails with 7mm (5mm +2mm) thick x 15mm wide pvc sheet bending on inner side, and joined together with solvent cement adhesive. an additional 5mm thick pvc strip of 20mm width is to be stuck on the interior side of the ‘c channel using pvc solvent adhesive etc. complete as per direction of engineer in charge, manufacture’s specification & drawing.(for w.c.and bathroom door shutter).including all door fittings such as hinges, l drop, handles, locking bolts etc. as per approved of engineer in charge. 31 p & f w.v.c. (is: 2556 mark) squatting urinal of standard make complete. including cutting & making good the floor: size 450x350mm 32 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor:size 580x440mm. 33 double syphonic european w.c. with mounted w.v.c. flushing cistern of 10 litre capacity complete with all necessary internal fittings with hydraulic seat cover. 34 p & f water closet seat covers with brass hinges complete : non breakable of other approved make white. 35 p & f lst quality wvc urinal (is:2556 mark) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. flat back (large) or half stall size 610x400x80mm. 36 p & f low level flushing cistern of 10 litres capacity (is : 2556mark). of approved make with complete fittings c.i. brackets duly painted, brass ball cock with ball, (is: 1703 mark) complete including cutting and making good the wall: pvc withpvcbend and superior internal fittings 37 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) & 32 mm c.p. brass waste coupling of approved make,25 mm g.i. waste pipe complete including cutting & making good the wall.:size 550 mm x 400 mm dia for counter top 38 p & f kitchen & lab. sink of approved make with c.i. brackets duly painted, 40 mm c.p. waste coupling, c.p. brass chain with rubber plug, 40 mm g.i. waste pipe up to floor level complete including cutting and making good the wall & floor : wvc lab sink (is:2556 mark) size 530 x 430 x 180 mm 39 p & f bottle trap of approved make : c.p brass 40 mm 40 p & f looking mirrors with p.v.c. frame of approved (atul, modiguard , saint gobin or equivalent) round 500mm dia 41 labour charges for removing wvc pan: european w.c. 42 p & f jet spray for water closet with c.p. copper tube flange of approved make. 43 providing & fixing c.p.flange for 15mm dia taps. 44 p & f bib cock (is : 8931 mark), superior quality of approved make:cp brass long body, 15mm nominal bore weight not less than 690 gm 45 p & f ball cock (is :1703 mark) with rod& p.v.c. ball complete : brass wt. not less than 300 gm,15mm. 46 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc.c.p. inlet connection 15mm.brass (is : 8931 marked) 47 p & f 15 mm. dia connection pipe of approved quality/make : pvc pipe withc.p. brass nuts upto length, 600mm 48 p & f full way valve (is:778 mark) or wheel valve of approved make gun metal 15mm nominal bore. 49 p & f full way valve (is:778 mark) or wheel valve of approved make gun metal 25mm nominal bore. 50 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:500 litres capacity. including hosting charges 51 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000 litres capacity. including hosting charges 52 providing and fixingsuperior qualitycp brassfittings complete as per direction of ei sink cock with swinging casted spout (table mounted ) 15 mm nominal size 53 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work exposed on wall) 20 mm nominal outer dia pipes 54 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge. (internal work exposed on wall) 32 mm nominal outer dia pipes 55 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 20mm nominal outer dia pipes 56 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 32mm nominal outer dia pipes 57 providing & laying c.c. 1:3:6 (stone agreegate 20mm nominal size) all around pvc pipe including 7.5 cm thick bed concerte [width & height =dia of pipe in cm+15cm] excluding cost of pipe & excavation of trenches etc. pvc pipe 110 mm dia 58 construction of chamber in all type of soil with 300 mm thick brick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. inside size 300 x 300 mm depth upto 0.5 mcement cover with frame. 59 construction of chamber in all type of soil with 300 mm thick brick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. inside size 450 x 450mm depth upto0.5 m cement cover with frame 60 construction of cement concrete chamber 125mm dia. stainless steel sheet grating 61 providing & fixing spun –centrifugally cast iron pipes (is : 3989 mark ) of approved make in wall or in floor with m.s. holder bat clamps in 10 x 10 x10 cm. m 15 grade concrete blocks, joints filled with cm 1:4 with spun yarn including cutting holes and making good the wall: 100 mm dia 62 providing& fixing spun –centrifugally cast iron pipes fitting (is : 3989 mark ) in cm 1:4 with spun yarn. socket 100 mm w/o door 63 providing& fixing spun –centrifugally cast iron pipes fitting (is : 3989 mark ) in cm 1:4 with spun yarn. bend 100 mm w/o door 64 providing& fixing spun –centrifugally cast iron pipes fitting (is : 3989 mark ) in cm 1:4 with spun yarn. tee 100 mm w/o door 65 providing& fixing spun –centrifugally cast iron pipes fitting (is : 3989 mark ) in cm 1:4 with spun yarn. cowel 100 mm w/o door 66 providing& fixing spun –centrifugally cast iron pipes fitting (is : 3989 mark ) in cm 1:4 with spun yarn. bend 100mm with door 67 providing& fixing spun –centrifugally cast iron pipes fitting (is : 3989 mark ) in cm 1:4 with spun yarn. tee 100mm with door 68 providing and fixing spun –cast iron floor trap (nahani) of (is :3989 mark ) approved quality / make with socket down or hinged grating including cutting and making good the floor : size 100 x 100 mm 69 cleaning of c.i. pipe line of various sizse as per requirement at site of different sizes including 100mm,150mm & 225mm diaof c.i.pipesas per direction of engineer in charge. 70 p & f grating of approved quality/make: stainless steel sheet size 125mm dia. heavy quality of approved make ...

Urban Improvement Trust - Rajasthan

33117971 various civil works and maintenance works in sub division i area of division ii b ( arc ) civil works clearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000m from road boundary. (morth specification : clause 201).by manual means : in area of light jungle 2 clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 silt clearance of drains, channels and canals with lift 1.5 mtr. and lead up to 50 mtr. 4 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 5 add extra over item no. 1.8 and 1.9 (sechedule item no 1) for every additional lift of 1.5 m or part thereof : 6 above 1.50 to 3.00m 7 m 35,60mm thick to be used in light traffic (light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 kn laden weight, or an wquivalent up to 0.5 million standerd axles (msa) for a design life of 20 years (a standerd axle is defind as a single axle load of 81.6 kn ) like pedestrain plazes, shopping complexes ramps, car parks, office drveways , housing colonies , office complexes , rural roads with low volume traffic ,fram houses, beach sites, tourist resorts, local authority footwys ,residential roads, etc. 8 category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 9 random rubble dry stone kharanja under floor. 10 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 11 m10 grade nominal mix, 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 13 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 14 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix 15 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 16 anti termite treatment of floor using imidacloprid 30.5% ec non repellent, odorless, low dose, environimentally safe terniticide with rapid action non corrosive stain free manufactured by bayer or equivalent company by drilling 12mm diameter holes 300mm apart injecting the emulsion as specified by the manufacturer and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area dpe 12mm dia termitube system with required number of junction boxes are to be installed. the termitube will run all along the perimeter wall both inside and outside. in the middle area the termitube to be installed at an interval of 1.00 mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. after successful testing of termitube, pesticide emulsion of imidacloprid 30.5% ec mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. the plinth area of the area treated will be measured for payment. 17 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 18 columns, pillars, posts and struts etc. 19 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in: 20 cement mortar 1:6 ( 1 cement : 6 sand). 21 cement mortar 1:4 ( 1 cement : 4 sand). 22 cement mortar 1:3 ( 1 cement : 3 sand). 23 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : 24 cement mortar 1:3 ( 1 cement : 3 sand). 25 cement mortar 1:4 ( 1 cement : 4 sand). 26 cement mortar 1:6 ( 1 cement : 6 sand). 27 pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 28 flush / ruled/ struck or weathered pointing. 29 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete and not applying 2 coats of hot bitumen complete as per specifications. 75mm thick 30 50mm thick 31 75 mm thick 32 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 33 suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 34 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 35 thermo mechanically treated bars (conforming of relevent is code) 36 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in : 37 cement mortar 1 : 4 (1 cement : 4 coarse sand) 38 cement mortar 1 : 6 (1 cement : 6 coarse sand) 39 half flyash brick masonry in foundation & plinth using flyash bricks of designation 75 40 cement mortar 1 : 4 (1 cement : 4 coarse sand) 41 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 42 12mm thick. 43 20mm thick. 44 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 45 making grooves as per design in plaster 10mm to 20mm wide. 46 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 47 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 48 two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 49 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 50 new work 51 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 52 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 53 two or more coats on new work 54 150cm high fencing with angle iron 50x50x6mm. placed at every 3mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with g.i. staples including earth work in excavation etc. complete. 55 grading roof for water proofing treatment withwater proffing compound 56 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 57 providing and fixing pressed steel door frames confirming to is 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applyinga coat of approved steel primer after pre treatment of the surface including filling with cc 1:2:4(m15 grade) complete as directed by engineer in charge : 58 profile b 59 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 30 mm thick . 60 decorative teak veneer both side 61 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). : for fixed portion 62 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 63 providing and fixing of plastic shutter infill made from extruded multi chamber hollow p.v.c. section having cross section of 200 x 20 x 1 mm and shutter frame made from extrude p.v.c. section in the configuration of double walled c section having an overall cross section of 40 x 37 mm and door fittings such as hinges, aldrop, handles, stopper, locking bolt will be provided. 64 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 65 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 66 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 67 providing and fixing superior quality like hardvyn or equivalent hydraulic door closure. 68 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 69 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 70 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : 71 good quality south black above 3601 cm2 slabs 72 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 73 granite work (full edge moulding ) 74 p & f 1st quality heavy duty vitrified glazed mat tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. 75 size600 mm x 1200mm 76 providing & fixingbrown kota/ mandana / dholpur/ slate stone incladding / flooring structuralbase with white cement & tinex chemical& ss clamp and fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attachedcomplete in all respect as per direction of engineer in charge & architect with all lead & lift. the stone measurement will be done of outer most dimension. thickness of stone 25 30mm. 77 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 78 25 mm thick slab. 79 s/f of fire bricks on edg flooring with fire bricks suitable for 1300 degree centigrade safe working temperature as per is :8 specification laid on & filling of joint by fire resistant mortar/adhesive of required thickness as per directed on a bed of 20 mm thick 1:2 cement mortar of bricks 9 x 4.5x 3 (rate approved year 2008) 80 providing and fixing of glass moisac tiles ( bisseze marke ) size 20 x 20 x 4 mm applied with aaproved adhesive as per specification and direction of engineer in charge 81 providing and fixing staincase railing 90 cm high from nosing of made offollowing specifications. 82 50 mm outer dia (2 mm thick) s.s. pipe hand rail. 83 40 mm outer dia (2 mm thick) s.s. pipe baluster @ 1.00 mtr. 84 4 nos. 20 mm fs. s pipe intermediate runners parallel to hand. 85 s.s. shoe 1.60 mm thick 75 mm outer dia. at each baluster 86 baluster to be welded with s.s. plate 50 mm dia (3 mm thick) anchored in c.c. block with suitable dash fastners 87 50 mm dia & 2 mm thick s.s. pipe for start and end vertical ornamental posts to be provided as per direction of engineer in charge 88 the stainless steel work shall be brushed steel finish with all joints/welds properly grinded to final finish. the stainless steel shall be 304 grade and shall confirm to relevant i.s. 89 providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.extra if square,rectangular hollow tubularsections are used or grill made by flats only 90 decorative plaster work with spectrum textured coating as per approved colour and shade complete as per manufactures specifications. 91 grit textured @ 2.5 to 3.0 mm thick. 92 ornamental cement plaster in cement sand mortar1 : 4 making kangooras etc. as per jaipurpractice. 93 supplying and fixing machine cutdressed 75 mm pinksand stone (bansi paharpur) dasa/ coping wth ornamental shape having moulding and pan shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 94 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 95 0.63 mm thick with zinc coating not less than 275 gm/m2 96 supply & spreading ofgood earth at site complete including loading unloading & transportation etc. 97 supply of dry manure including loading unloading,transportation & stacking at site. 98 farm yard manure(organic) 99 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 100 laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc.(cost of manure or extra good earth to be paid seperately) maintenance of lawns for 30 daysor more till the grass forms a thick lawns free from weeds & fit fo 101 in rows 7.5 cms. apart in either direction 102 construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8 10 tonne to meet requirement of table 300 2 including cost of compensation for earth taken from private land with lead upto 1 km as per morth specification : clause no. 305. 103 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 104 p & f european type white glazed vitreous china 1st quality double syphonic w.c (is :2556 mark) with p or s trap including cutting and making good the wall and floor 105 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor: 106 size 580x440mm. 107 p & f low level flushing cistern of 10 ltr. capacity (is : 2556 mark) o9f approved make with colplete fitting ,c.i. brackets duly painted , brass ball cock with ball, (is :1703 mark)complete including cutting and making good the wall. 108 wvc with c.p. brass bend. 109 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) &32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall.: 110 size 550 mm x 400 mm dia for counter top 111 1.0 mm thick salem stainless steel aisi 304 & is 13983 1994kitchen sink of approved make (nirali, neel – kanth, jaina, faber castell )with large waste coupling. 112 (24 x 18 x 8) (20x16x8) 113 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. 114 c.p. inlet connection 15mm.brass (is : 8931 marked) with 37 cm long pipe and nut. 115 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 116 1000 litres capacity. 117 providing and fixingsuperior quality (jaguar contiental ) cp brassfittings complete as per direction of ei 118 bib cock with long thread 15 mm nominal size 119 brass / gunmetalhalf turnwt. 1 kg.ofapprovedquality / make,25mmnominalbore. 120 p & f full way valve (is:778 mark) or wheel valve of approved make 121 gun metal 32mm nominal bore. 122 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 123 20mm nominal outer dia pipes 124 32mm nominal outer dia pipes 125 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 126 110 mm dia 127 160 mm dia 128 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: 129 coupler (socket) 130 110mm dia 131 160 mm dia 132 plain tee 133 110mm dia 134 160mm dia 135 door tee 136 110mm dia 137 bend 45 138 110mm dia 139 vent cowel 140 110mm dia 141 door bend (left & right) 142 110mm dia 143 pipe clip 144 110mm dia 145 plain floor trap 146 110mm dia 147 p trap 148 110mm dia 149 socket plug 150 110mm dia 151 door cap 152 110mm dia 153 construction of chamber in all type of soil with 300 mm thick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 154 do size 450 x 450mm depth upto0.5 m cement cover with frame 155 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,hot dipped galvanized modular box with earth terminal, 6 a modular switch,modular plate with grid plate,screws,making connections, testing etc. as required. 156 short point (up to 3 mtr.) 157 medium point (up to 6 mtr.) 158 long point(up to 10 mtr..) 159 wiring of twin control light point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper earth conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 160 medium point (up to 6 mtr) 161 wiring of 3 pin 6 amp light plug point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp switch & 6 amp socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 162 on board 163 medium point (up to 6 mtr) 164 long point (up to 10 mtr) 165 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. 166 25 mm 167 32 mm 168 50 mm 169 supplying and fixing of power plug point modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. switch and socket outlet, making connection , testing , etc. as required. 170 p&f metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without mcb) including making connections, testing etc.as required 171 single / double pole(three pin) 172 32 a 173 providing & fixing isi marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. 174 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 175 2 x 2.5 sq. mm. + 1x1.5sqmm 176 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 177 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 178 single pole mcb 179 6 a to 32 a rating 180 four pole mcb 181 40 a 63 a rating 182 four pole mcb 183 6 a to 32 a rating 184 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required. 185 double door (single phase) 186 12 way 187 double door (three phase) 188 8 way 189 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 190 25.0 sq.mm 191 4 core 192 50.0 sq.mm 193 120.0 sq,mm 194 3.5 core 195 150.0 sq,mm 196 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 197 3.5 x 120.0 sq.mm 198 4 x 25.0 sq.mm 199 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 200 10.0 sq.mm 201 4 core 202 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty copper lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 203 4 x 10.0 sq.mm 204 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of crca sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadethe panel having pu/ neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate m.s. base channel ,hinged door with locking arrangement for equipment/switchgear. thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. load bearing structure shall beof 2.0 mmthick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from cpri approved fabricator) 205 supplying and fixing of aluminium / copper bus barby means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. 206 electrolytic grade aluminium bus bar 207 sf of (0 500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 208 analog type ( 96mm x 96mm ) 209 sf of ct operated direct reading typeampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 210 analog type ( 96mm x 96mm ) 211 below 500 a 212 sf ofcurrent transformer, with all necessary support in existing panel including connection etc. as required . 213 up to 150/5 ratio, 10 va, class 1 accuracy 214 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc.as required . 215 sf of ct linked selector switch of 10 aforampere meter (4 position ) including making connection etc.as required . 216 sf of110/220 v, led (22.5 mm dia ) indicatinglamp with integral circuit, terminal block, including connection etc. as required. 217 red/yellow/green colour 218 supplying and drawing fr pvc insulated & unsheathed flexiable copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 219 1 x 1.5 sq.mm 220 1 x 2.5 sq.mm 221 1 x 4.0 sq.mm 222 1 x 6.0 sq.mm 223 sitc of self healing mpp/mp type shunt capacitor (banks) conforming to is:13340 41 / iec :831 1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.5 watt per kvar . including making connections with suitable capacity conductors/cables testing etc. as required. 224 heavy duty three phase 440 v , 50 hz capacitor (bank) 225 sitc of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar,metering facility as required. 226 6 to 8 stage 227 sensitivity upto 50 milli amp 228 p & f ofcam operated rotary switchs on existing panel with 2 way and off postion 229 one pole 230 16 amp 231 p & f of440 volt 3 pole capacitor(ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to is:13947 4 1/iec:947 4 1, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 232 up to 6 kvar 233 7 to 10 kvar 234 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 235 triple pole mcb 236 6 a to 32 a rating 237 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating: 238 open execution type 239 200 amp 240 sitc of quick make and quick break4 polecurrent limiting mccb having following current rating, short circuitbreaking capacityat 440/415 v, 50 hz; o/l & s/c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 241 with thermal magnetic release 242 up to 160 amp , 25 ka, adjustable o/l & fixed s/c setting, ics = 100 % icu 243 plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 244 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 245 8 swg copper wire 246 providing & fixing of heavy duty capacitor start 900/1400 rpm single phase isi marked exhaust fan is:2312 marked in existing opening making connections, testing etc. as required 247 300 mm sweep (900/1400 rpm) 248 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 249 1400 mm sweep 250 p & f of ip 20 led tube light 20 watt with external batten made from crca sheet steel suitable to replace t 8/t 12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 lm/ watt minimum expected life time of 25000 burning hours, cct 5700 k ansi, cri 80, driver efficiency >85%, life expectancy of driver rnin 30000 hrs. pf 0,95 at full load/ 230 volt ac. 251 p & laying xlpe insulated is:7098/ii/85 of group1 and approved make h.t.cable for working voltage 11 k.v.earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 252 3 core 185.0 sq.mm ...

Rajasthan Tourism Development Corporation Limited - Rajasthan

33038325 furbishment work at paryatan bhawan jaipur furbishment work at paryatan bhawan jaipur carriage of building rubbish stone metal etc to a distance upto 10 km including safely stacking of material all as per instructions and directions. 2 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level.m15 grade nominal mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size) 3 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 4 centering & shuttering with plywood or steel sheets includingstrutting, propping bracing both ways with steel props and removalof formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders,cantilevers, bands, coping bed plates, anchor blocks, sills,chhajjas, lintel, beam, plinth beam etc. 5 providingandfabricatingreinforcement forr.c.c.workincludingstraightening, cutting, bending, placing in position and binding including cost of binding wire) all complete up to floor five level. thermo mechanically treated bars (conforming of relevent is code 6 brick work with f.p.s.bricks of class designation 75 in superstructure above plinth level up to floor v level in all shapes and sizes in : cement mortar 1 : 6 (1 cement : 6 coarse sand) 7 half brick masonry in superstructure , above plinth level upto floor v level using bricks of designation 75cement mortar 1 : 4 (1 cement : 4 coarse sand) 8 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 9 providing & fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade : ghana teak wood grade i. 10 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked usingphenol formal dehyderesin in glue both sides with approve steel fittings complete as per annexure a 35 mm thick. decorative teak veneer both side 11 extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) over item no. 8.13. 12 extra for providing other type of fittings as mention in annexure a ( as approved by ei) : brass fittings 13 providing and fixing is : 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. 14 providing and fixing nigeria / ghana /ivory coast, teak wood grade i mouldings and beadings in doors and windows size : 15 25x12 mm 16 25x20 mm 17 providing and fixing bright finished mortice lock of approved make godrej or equivalent with pair of cp handles for doors with necessary screws etc complete (best make of approved quality) as per direction of engineer in charge. 18 extra for providing brass handle instead of cp handle 19 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12mm (av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.good quality south black, area above 3601 cm2slabs 20 extra for providing edge moulding to 15 18mm thick marble/ granite/kota stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer incharge. granite/kota stone work half edge moulding 21 extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 22 extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location inmarble/granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 23 steel work in built up tubular trusses including cutting, hoisting (height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete. hot finished welded type tubes. 24 supply and installation of multi rib proofing/cladding sheet manufacture out of 0.60mm tct (total coated thickness) high tensile zinc aluminum alloy coated galvaiumeseel (as per 150gsm zinc aluminum coated 550mpa tuekd strength) confirming to is: 1397/astm a 792 sheet to have wide pens 30mm high nb at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at toprevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. the sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding. 25 removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) 26 french sprit polishing : two or more coats on new work including a coat of wood filler. 27 providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 28 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 29 providing and applying superior quality wall painting with velvet touch emulsion paint of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of engineer in charge. new work three or more coat 30 finishing walls with acrylic smooth exterior paint of required shade including all scaffolding.new work (two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 31 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work 32 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. 1: 3: 6 or richer mix. 33 dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead: for thickness of tiles 10mm to 25mm. 34 dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 35 removing aluminium/gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by engineer in charge. 36 providing and fixing sun control film, thickness of film 1 mil visible light transmittance 4 24% & solar energy transmittance 42 51% & total solar energy rejection 37 43% of approved colour and shade , complete in all respect , at all level , as directed by engineering charge. 37 providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 38 gi metal ceiling lay in perforated tegular edge global white colour tiles of size 595x595mm and 0.5 mm thick with 8 mm drop made of gi sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having nrc (noise reduction coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black glass fiber acoustical fleece. ...

Department Of Defence - Rajasthan

32925414 bids are invited for distemper colour pink make berger asian nerolac , distemper colour white make berger asian nerolac , distemper colour pale cream make berger asian nerolac , fevicol in 1 kg pack , snowcem pale cream , fevicol ddl in 1 kg pack , paint phiroze blue make berger asian nerolac , blue robin neel , painting brush nylon 75 mm , roller brush for painting 9 in , emulsion paint pale cream exterior make berger asian nerolac , emulsion white paint exterior make berger asian nerolac , stainer d colours make berger asian nerolac , white washing brush , cement primer , thinner , red oxide , wall putty , putty glass white , distemper brush 5 in 6 in , lime slacked unslacked , geru mitti , paint golden yellow make berger asian nerolac , paint white make berger asian nerolac , paint black make berger asiannerolac , paint synthetic enameled po red make bergerasian nerolac , paint synthetic enammeled blue makeberger asian nerolac , paint synthetic enamelled greenmake berger asian nerolac , painting brush nylon 1 in ,painting brush nylon 2 in , painting brush nylon 3 in ,painting brush nylon 4 in , glass putty , dendrite woodshine , varnish , kuchi for white wash , paint sky blue makeberger asian nerolac , paint pale cream make berger asiannerolac , paint og make berger asian nerolac , paintenamelled revera blue make berger asian nerolac , sandpaper no. 100 , writing brush 0 to 12 nos , distemper pinkoil bound make berger asian nerolac , wood primer total quantity : 2537...

Urban Improvement Trust - Rajasthan

32830880 various civil work and repairing work in sub div i of div. ii a area. ( arc ) civil works earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 2 earth work in excavation by mechanical means (hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed: all kinds of soil 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 4 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level.m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 5 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 6 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete as per specification . 50mm thick. 7 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 8 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 50mmthickwith20mmthicknominalsizeaggregate. 9 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 10 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 11 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 12 m 40,80mm thick to be used in medium traffic (medium trafficis defind as a daily traffic of 150 450 commercial vehicles exceeding 30 kn laden weight , or an equivalent of 0.5 to 2.0 msa for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 13 add extra over rates of 1a to e, if colored paver blocks are used 14 supply & stacking good soil of earth at site complete including loading unloading & transportation etc. good soil of earth 15 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 16 s & fcc 1:2:4 (m15) precast kerb on dand upto 60 cm length over 20 mm thick base of cement mortar 1:6 including jointing, earthwork, painting and jointing with cement mortar 1:4 of size.15 × 40 cm 17 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 2001 to 5000 sq.cm : 25 mm thick slab. 18 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 19 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 20 add extra if square, rectangular hollow tubular sections are used. 21 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 22 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : one or more coats on old work. 23 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: on new surface. 24 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: on old surface. 25 providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with : stone slab 40 to 50 mm thick average. 26 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 27 flyash brick masonry with flyash bricks of class designation 75infoundation and plinth. cement mortar 1 : 6 (1 cement : 6 coarse sand) 28 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 29 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) light shade using shade cement. 30 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 31 providing and laying reinforced cement concrete pipes np 3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (morth specification : clause 1000/2900). 32 300 mm dia 33 600 mm dia 34 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of :jhansi (red/chocolate colour) above 3601 cm2 slabs 35 transportation of excavated of earth from site including loading unloading etc. complete with all lead and lift. lead upto 5 km. 36 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 37 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. new work 38 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 39 providing, laying and spreading of granular sub base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at omc, and compacting with vibratory roller to achieve the desired density, complete as per morth specification : clause no. 401. grading iii 40 p & f stone cladding / flooring works dressed bansi paharpur stone 25mm thick in traditional style used in cladding/flooring with pattern over 25 to 50 mm thick base in cm 1:6 including pointing with cement mortar 1:2 (cement : 2 stone dust) matche the shade of stone with joint thickness upto 1.5mm as per direction of engineer in charge. 41 single piece of stone element with carving work in bansi paharpur stone includes stone pillar, stone base, todies and thabi etc carving work as per direction of engineer in charge 42 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 43 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 44 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 4.0 sq.mm 4 core 45 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 6.0 sq.mm 4 core 46 p&f strip type fluorescent tube fitting fabricated from (crca) sheet and finished with powder coating/stove enamelled paint/ (extruded non corrosive uv resist ep channel) complete with accessories like (occb, starter, starter seat) / eb, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required. (without tube) 1×36 watts with occb, group i 47 p&f fluorescent tube rod in existing fixtures as required. fluorescent powder coated 36/40 watts, group ii 48 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm sweep.group i 49 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) for fixed portion 50 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) 51 providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade i, type ii conforming to is : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with c.p. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer in charge. prelaminated particle board with decorative lamination on both sides. 52 providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge.(cost of aluminium snap beading shall be paid in basicitem.) with glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per is : 2835. 53 providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, y and h aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) 54 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a:30 mm thick commercial veneer both side 55 providing& fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade : sal wood grade i. 56 wiring of twin control light /fan / call bell point with 1.5 sq. mm nominal size fr pvc insulated unshethed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unslated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) of approved make in surface / recessed isi marked mms (is:9537 p iii) pvc conduit & its accessories, round tles, 18 swg m.s. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 a two way switch, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. short point (up to 3 mtr.) 57 (a) short point (up to 3mtr) 58 (b) medium point (up to 6mtr) 59 ( c ) long point (up to 10mtr) 60 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kg grade (is:694) of approved make in surface/ recessed isi marked medium duty pvc conduit & its accessories, hot dipped galvanized m.s modular box with earth terminal, screwless cage connectors for neutral looping in switch board , 6 a modular switch, 6 a modular socket, modular plate with grid plate, screws, making connections, testing etc. as required. on board 61 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 62 2 x 2.5 sq. mm + 1x1.5 sqmm 63 2 x 4.0 sq. mm + 1x1.5 sqmm 64 p & f following sizes (dia) of isi marked medium duty pvc coduit along with accessories in surface/ recessed using sadles, clamps, fastener, as required including cutting the wall and making good the same as required. group ii, 25 mm dia 65 s&f following sizesof isi marked ( is:14927 p ii ) pvc casing capping along with accessorieslike coupler, inner, outer, elbow, square box, tee etc. on surfacewith screws, expansionfastenersas required. 66 32 mm x 12 mm 67 50 mm x 20mm 68 cement concrete pavement of required thickness with 1:1.5:3 (1 cement:1.5 course sand : 3 graded stone aggregate 20 mm nominal size) including finishing complete. 69 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. 1: 3: 6 or richer mix. 70 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. in cement mortar. 71 cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealingcompound in groove including cost of sealing compound.100 mm depth 72 repair to cement plaster in cement mortar 1 : 6 (1 cement : 6 fine sand) including removal of old plaster in regular shape and white or colour washing. 73 providing and fixing stone jali 40mm thick red/pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 74 supplying and fixing machine cut fine dressedred/pink sand stone dasa orcoping,with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 25mm thick 75 half flyash brick masonry in superstructure , above plinth level upto floor three levelusing flyash bricks of designation 75 cement mortar 1 : 6 (1 cement : 6 coarse sand) 76 random rubble dry stone kharanja under floor. 77 surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 mtr. and lift up to 1.5 mtr.:all kinds of soil 78 filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 79 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 80 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : walls (any thickness) including attached pilasters,buttressesplinthandstring course. 81 supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 82 50mm x 50mm x 3.15mm 83 providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with :stone slab 100 to 150 mm thick average. 84 repair to stone masonary in cement sand mortar 1:6 with old and new stone. 85 repair to brick masonary in cement sand mortar 1:6 withnew brick. 86 filling expansion joint with bitumen filler in plain or reinforced cement concrete 25 mm width & 25 mm deep. 87 providing and laying water proofing treatment with thermalinsulation havingthickness of 2.5 3.0 mm over the existing r.c.c. roof by as per direction and satisfaction of engineer in charge and consisting of:(i) cleaning and washing of the existing roof including removing of loose material from the surface of cracks.(ii) widening and deepening of cracks to fill the approved crack filler as per direction of engineer in charge.(iii) application of one coat of approved sealing compound approved by engineer in charge with following specification or equivalent compound @ 0.17 litres per square meter with required brush as per direction of engineer in charge.(iv) application of the mesh approved by engineerin charge (made up of glass fiber , woven structure of leno make , reinforcing with alkali resistant coating having 10x10 mesh size, weight/sqm is 90gm to 120 gm and of 0.25 mm thickness including resin content (%) : 18% ) orequivalentand then application of coat of sealing compound approved by engineerin charge with specifications as narrated above ,without use of water @ 0.33 litre per square meter with brush and dryingof surface for24 hoursas perdirectionof engineerin charge. 88 providing and fixing aluminium composite panel ofapproved make 3mm thick with 0.5mm thick skin & pvdf coated approved shade for wall panelling. main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. stainless steel screw to be used to fix the acp panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in all respect as approved by engineer in charge. 89 providing & fixing uv stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘j’ or ‘l’ hooks, bolts & nuts 8mm dia. g.i plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. the sheets shall be manufactured out of 2400 tex panel rovigs incorporating minimum 0.3% ultra voilet stabiliser in resin system under approximately 2400 psi and hot cured. they shall be of uniform pigmentation and thickness without air pockets and shall confoim to is 10192 and is 12866.the sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 90 5.0mm thick (wt. 8.4 kg./mtr. sq.) 91 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : cement mortar 1:6 ( 1 cement : 6 sand). 92 providing and fixing marble stone flooring table rubbed, 15 18 mm thick over 20mm (av.) thick base of cm 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. white marble : makrana adanga. 801 cm2 to 1500 cm2 tiles 93 p & f g.i. pipes (internal work) with g.i. fittings excluding union (is:1239 mark) & ms clamps including cutting and making good the walls and floors: exposed on wall 94 15 mm dia nominal bore b class 95 25 mm dia nominal bore a class 96 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 97 4 x 10.0 sq.mm 98 4 x 16.0 sq.mm 99 sitc of 11 kv, 400/630 a, 20ka / 3 sec, out door,extensible type ring main unit (rmu) in suitable rcc foundation with 2 no. load break switch & 1 no. vcb / sf6 circuit breaker with over load, earth fault, short circuit relay, copper bus bar, earthing switch, mechanical on / off /earth indication, voltage presence indicator, ring core protection ct 2.5 va, 10p10 as per transformer rating, shunt trip coil, anti reflex operating handle, right angle boots etc. as required. 100 providing and fixing corrugated colour g.i sheet having thickness 0.50mm roofing fixed with g.i.j or l hooks bolts and nuts 8mm dia meetr with bitumen and g.i limpet washers or with g.i limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect. 101 providing & fixing of hdpe pipe isi mark (is:4984/95) for water supply (suitable for submersible & jet pump) with required fittings 102 40 mm od6 kg / cm2 103 50 mm od6 kg / cm2 104 63 mm od6 kg / cm2 105 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 106 10.0 sq.mm 107 4 core 108 16.0 sq.mm 109 4 core 110 70.0 sq,mm 111 3.5 core 112 120.0 sq.mm 113 3.5 core 114 sitc of radial / mixed flow submersible motor pump sets isi marked (is:8034 1989) of approved make with required accessories including making connection suitable for t.w./ d.c.b./ open well. the job includes lowering ofriser pipe, g.i./h.d.p.e. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. all labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.150 mm diameter submersible pump shall havefollowing hp rating, phase, head, minimum discharge respectively. 115 5.0 hp, 3 ø, (32 52)mtr, (400 167)lpm 116 7.5 hp, 3 ø, (45 73)mtr, (400 280)lpm 117 10.0 hp, 3 ø, (64 104)mtr, (400 167)lpm 118 construction of tube well upto 100 meter depth and above in all type of rocks by dth system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casingpipes as per is : 2800 (part i & ii) 1979 specifications. the work would be completed after obtaining sand free water. the tube well should have a throughout bore as per nominal dia of casing pipe: 119 200 mm –do 120 supply of erw m.s. black casing pipe isi marked (is:4270/1992) of grade fe410 of following sizes at site of work. 121 nominal bore of pipe (mm) 200 122 testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per is: 2800 (part ii) 1979. 123 s & f tube well cover ofm.s.sheet (6mm thick) with nuts and bolts complete for casing size: 124 200mm dia 125 s & f m.s. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 126 installation of submersible motor pump set in tube well/open well complete ( labour charges only) including transportation of tripod, chain pulley block & any other material required for lowering purpose. 127 p/laying isi marked p.v.c. insulated submersible cable confirming to is:694 with flexible copper conductor including making connection etc. as required. 128 6.0 sq.mm 3 core flat / round 129 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. group 1 130 1 x 1.5 sq.mm 131 1 x 2.5 sq.mm 132 1 x 4.0 sq.mm 133 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. group 1 134 25 mm 135 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required.single pole mcb , 6 a to 32 a rating group 1 136 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required. double door (three phase) 12 way group 1 137 p&f 240/415 v isolator conforming to is:13947 iii/ iec 60947 3 on existing board / sheet including making connections, testing etc. as required. four pole isolator 63 a rating group 1 138 providing and fixing corrugated colour g.i sheet having thickness 0.50mm roofing fixed with g.i.j or l hooks bolts and nuts 8mm dia meetr with bitumen and g.i limpet washers or with g.i limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect. ...

Urban Improvement Trust - Rajasthan

32713522 various civil miscellaneous work in div. ii a ( arc ) civil works earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 2 cement concrete pavement of required thickness with (b) 1:1.5:3 (1 cement:1.5 course sand : 3 graded stone aggregate 20 mm nominal size) including finishing complete. 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level.m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 4 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 5 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in :cement mortar 1:6 ( 1 cement : 6 sand). 6 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 7 pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : flush / ruled/ struck or weathered pointing. 8 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete as per specification .50mm thick. 9 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 50mmthickwith20mmthicknominalsizeaggregate. 10 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. 20 grade nominal mix 11 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. hot rolled deformed bars (is : 1139). 12 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 13 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 14 providing and fixing corrugated colour g.i sheet having thickness 0.50mm roofing fixed with g.i.j or l hooks bolts and nuts 8mm dia meetr with bitumen and g.i limpet washers or with g.i limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect. 15 supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 16 50mm x 50mm x 3.15mm 17 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 18 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 19 one or more coats on old work. 20 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 21 one or more coats on old work. 22 two or more coats on new work 23 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 24 old work 25 new work 26 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: new work (two or more coats applied @ 3.84 kg/10 sqm). 27 old work (one or more coats). 28 clearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000m from road boundary. (morth specification : clause 201). : in area of thorney jungle 29 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : walls (any thickness) including attached pilasters,buttressesplinthandstring course. 30 m 40,80mm thick to be used in medium traffic (medium trafficis defind as a daily traffic of 150 450 commercial vehicles exceeding 30 kn laden weight , or an equivalent of 0.5 to 2.0 msa for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. : category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 31 add extra for coloued 32 random rubble dry stone kharanja under floor. 33 providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with :stone slab 40 to 50 mm thick average. 34 transportation of excavatedearth from site including loading – unloading etc. complete with all lead and lift.(for 5 km lead) 35 providing and laying m30 grade controlled cement concretepavements including mixing and vibrations concrete with necessary needle vibrators and surface with screed board vibrating complete in all respect with 20/25 mm stone aggregate (crusher broken) including anti skid textured finish to required camber/ super lavation and grade including curing etc. as per specification with cement concrete m 30 grade including cost of steel frame work for sides of c.c. pavement consisting of m. s. channels flats and angles with required steel pegs ( some of them may left embedded in concrete/ including providing frame work 36 cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealingcompound in groove including cost of sealing compound.100 mm depth 37 expansion joints raised type as per approved drawing. 38 providing and fixing 3 layer pp r (polypropylene random coplymer ) pipes sdr 7.4 uv stabilized and antimicrobial fusion welded, having thermal stability for hot & cold water supply including all pp r plain & brass threaded polypropylene random fittings and fixing the pipe with clamps at 1.00 spacing. this includes testing of joint complete as per direction of engineer in charge.( internal work exposed on wall) pn 16pipe, 20 mm od 39 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. 1: 3: 6 or richer mix. 40 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. 41 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. in cement mortar. 42 demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge: in cement mortar. 43 dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead: of area exceeding 3 square meter. 44 taking out doors, windows and clearstory windows shutters (steel or wood) including stacking within 50 meters lead: of area exceeding 3 square meter. 45 dismantling wood work in frames, trusses, purlins andraftersupto10meterspanand5mheight including,levellingstackingthematerial within 50m lead: of sectional area 40 sq.cm and above 46 dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 47 dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 48 dismantling chajja and shelves with care including making jhiries and making good : stone shelves. 49 repair to cement plaster in cement mortar 1 : 6 (1 cement : 6 fine sand) including removal of old plaster in regular shape and white or colour washing. 50 patch repair to cement concrete floor including digging out old floor in regular shape and removal of rubbish curing etc. complete in all respects. 51 making the opening inmasonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground.for door/windows/clerestory windows 52 add extra item no. 13.15 for fixing of door / window frames (chowkhats or steel windows) in the opening including fixing hold fast in cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 stone grit 20 mm nominal grade) excluding the cost of frame or steel windows. 53 renewing glass panes, with putty and nails wherever necessary:float glass panes of thickness 4 mm 54 fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts embedding hold fasts in cement concrete blocks with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominaal size)painting two coats of coal tar to sides of chaukhats and making good the damages to walls and floors as required complete including disposal of rubbish to the dumping ground within 50 metres lead 55 door chowkhats 56 window chowkhats 57 providing and fixing double scaffolding system on the exterior side, upto five story made with 4 wodden member 1.5 m c/c horizontal and vertical direction joining with rassi, clamps, challies. the scaffolding system shall be stiffened with bracing, runner, connection of building if necessary with all essential safty features for the workmen etc complete as per direction of ei.the lavation area of the scaffolding shall be mearured for payment. the paeyment will be made once irrespective of duration of scaffolding.note : this item to be used for maintence work judically 58 repair of existing steel glazed doors, windows and ventilator, ms sheet door, garge doors, compound wall gates etc. by welding drilling complete include. cost of welding rods and hire charge of welding meachine and tp etc complete 59 providing and fixing fully panelled double leaf shutters for windows and ventilators as per approved design and drawings with approval steel fittings as per annexure a and width of styles, bottom and top rails 75 mm including beading of 25 mm x 15 mm size on both faces. 30 mm thick nigeria teak wood grade i 60 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 30 mm thick . decorative teak veneer both side 61 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm :35 mm thick red sand stone. 62 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 63 providing& fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade : sal wood grade i. ...

LNM Institute of Information Technology - Rajasthan

32692583 rate contract of paint work (services with material) 1 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:new work (two or more coats) over and including scrapping, primer, putty, lippy etc. complete in all respect. 2 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding:old work (one or more coats) including scrapping surface and necessary repairs (primer, putty, lippy etc. complete in all respect.). colour change 3 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: old work (one or more coats) including scrapping surface and necessary repairs(primer, putty, lippy etc. complete in all respect.). –same colour 4 painting with synthetic enamel paint of approved brand and manufacture to give an even shade:two or more coats on new work. 5 painting with synthetic enamel paint of approved brand and manufacture to give an even shade: one or more coats on old work. 6 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work.50mm dia. pipes. 7 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work.75mm dia. pipes. 8 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work.100mm dia. pipes 9 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work.150mm dia. pipes 10 applying priming coat: with ready mix pink or grey primer of approved brand and manufacture on wood work hard and soft wood. 11 applying priming coat:with ready mix of aluminium primer of approved brand and manufactured on resinous wood and plywood 12 applying priming coat:with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works 13 applying priming coat:with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 14 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:two or more coats on new work including preparation of base with primer, putty, lippy etc complete in all respect. 15 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: old work (one or more coats)on new work including preparation of base with primer, putty, lippy etc complete in all respect. 16 providing and applying superior quality wall painting with velvet touch emulsion paint of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of engineer in charge.new work three or more coat 17 providing and applying superior quality wall painting with velvet touch emulsion paint of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of engineer in charge.old work analysis 18 painting exterior surface of wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including preparation of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision. new work 19 painting exterior surface of wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including preparation of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision.old work 20 finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision. roller finish av. thickness 400 to 500 microns. 21 finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision. trowel finish av. thickness 1500 to 2000 microns. 22 polishing on wood work with ready mixed wax polish of approved brand and manufacture :new work 23 polishing on wood work with ready mixed wax polish of approved brand and manufacture: old work 24 m.s. pipe(20x20mm)with primer coatingupto 9 mtr 25 providing and applying melamine polish on teak wood work of approved brand and manufacture to give an even shade with two or more coats by compressor including sand papering, wood filler coat etc complete in all respect: new work 26 providing and applying melamine polish on teak wood work of approved brand and manufacture to give an even shade with two or more coats by compressor including sand papering, wood filler coat etc complete in all respect: old work 27 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: old work (one or more coats) including scraping the surface, etc. complete in all respects. – same/colour change. ...

Indian Institute Of Information Technology - Rajasthan

32598472 tender for rate contract of paint work (services with material) 1 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: new work (two or more coats) over and including scrapping, primer, putty, lippy etc complete in all respect. 2 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: old work (one or more coats) including scrapping surface and necessary repairs (primer, putty, lippy etc complete in all respect.). colour change 3 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: old work (one or more coats) including scrapping surface and necessary repairs (primer, putty, lippy etc complete in all respect.). – same colour 4 painting with synthetic enamel paint of approved brand and manufacture to give an even shade: two or more coats on new work. 5 painting with synthetic enamel paint of approved brand and manufacture to give an even shade: one or more coats on old work. 6 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work. 50mm dia. pipes. 7 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work. 75mm dia. pipes. 8 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work. 100mm dia. pipes 9 painting (two or more coats) on rain water, soil, waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on old work. 150mm dia. pipes 10 applying priming coat: with ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 11 applying priming coat : with ready mix of aluminium primer of approved brand and manufactured on resinous wood and plywood 12 applying priming coat : with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works 13 applying priming coat : with ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) 14 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: two or more coats on new work including preparation of base with primer, putty, lippy etc complete in all respect. 15 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: old work (one or more coats ) on new work including preparation of base with primer, putty, lippy etc complete in all respect. 16 providing and applying superior quality wall painting with velvet touch emulsion paint of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of engineer in charge. new work three or more coat 17 providing and applying superior quality wall painting with velvet touch emulsion paint of approved brand and manufacture to give an even shade with putty and preparation of surface applying with the help of paint roller the work complete in all respect as per direction of engineer in charge. old work analysis 18 painting exterior surface of wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including preparation of base with sandpapering, primer, putty, etc complete in all respect including scaffolding and safety provision. new work 19 painting exterior surface of wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including preparation of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision. old work 20 finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision. roller finish av. thickness 400 to 500 microns. 21 finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision. trowel finish av. thickness 1500 to 2000 microns. 22 polishing on wood work with ready mixed wax polish of approved brand and manufacture : new work 23 polishing on wood work with ready mixed wax polish of approved brand and manufacture: old work 24 m.s. pipe(20x20mm)with primer coating upto 9 mtr 25 providing and applying melamine polish on teak woodwork of approved brand and manufacture to give an even shade with two or more coats by compressor including sandpapering, wood filler coat etc complete in all respect: new work 26 providing and applying melamine polish on teak woodwork of approved brand and manufacture to give an even shade with two or more coats by compressor including sandpapering, wood filler coat etc complete in all respect: old work ...

Rajasthan State Agricultural Marketing Board - Rajasthan

32582101 various yard works ( 2 nos. ) / kums sri ganganagar ( fandv ) package 01 / 2022 23 / sgnr / development / provision of various facilities in mandi yard kums sri ganganagar (f&v) 2 part a (civil work) 3 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge : 1: 3: 6 or richer mix. 4 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge : in cement mortar 5 removing mortar from bricks and cleaning bricks including stacking within a lead of 50 meters (stacks of cleaned bricks shall be measured) : from brick work in cement mortar. 6 disposal of earth, sand, gravel, u/s kankar, lime, flyash, morrum, manure or sludge up to 5000 mtr. beyond ist 50 mtr. lead (including loading and unloading) 7 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. 8 demolishing mud phuska/ lime dhar/ kharanjain terracing and disposal of unserviceable material within 50 meters lead. 9 dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 10 repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : with cement mortar 1 :4 ( 1 cement : 4 coarse sand) 11 dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead : of area 3 square meter and below. 12 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter : all kinds of soils 13 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 14 a) m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 15 c) m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 16 brick work with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 infoundation and plinth with : cement mortar 1 : 6 (1 cement : 6 coarse sand) 17 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. : m20 grade nominal mix /design mix 18 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 19 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc : m20 grade nominal mix / design mix 20 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 21 brick work with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1 : 6 (1 cement : 6 coarse sand) 22 honeycombbrickworkhalfbrickthickwithcommon burnt clay f.p.s.(non modular) bricksofclassdesignation7.5uptofloor five level in : cement mortar 1 : 4 (1 cement : 4 coarse sand) 23 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level : cold twisted deformed bars (is : 1786). 24 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 25 plaster on new surface on wall in cement sand mortar 1:6 including racking of joints etc. complete fine finish : 26 a) 20mm thick 27 b) 12mm thick 28 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 29 grading roof for water proofing treatment withwater proffing compound : cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 30 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 31 kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : for area of each slab from 901 to 2000 sq.cm. 32 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 33 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 34 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 35 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 36 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect : on new work 37 providing&layingpopcorniceofrequireddesign&patterninceilingincludingnailing&scafolldingetc.completewithfinefinishing of size : 50mm x 50mm. 38 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 39 supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. m.s. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 27.5cm. long wire springs grade no. 2 and m.s. top cover 1.25mm thick for rolling shutters as per design. (clear openable area to be measured for payment). 40 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint 41 providing & fixing fly proof wire gauze to windows, clerestorywindows & doors with m.s. flat 15x3 mm and nuts & bolts complete : galvanised m.s. wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides 42 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : partly fixed and partly openable (fixed area not to exceed 33%) 43 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion.(i) single socketed pipes : type b, 110 mm diameter. 44 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion : single bend w/o door 87.5 deg. : 110mm dia 45 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12mm (av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete : south (red/cholate colour) : 1501 cm2 to 3600 cm2 tiles. 46 p & f wvc wash basin (ist quality is:2556 mark) of approved make with c.i. brackets duly painted 1 no. 15 mm c.p. pillar cock (is:8934 mark) & 32 mm c.p. brass waste coupling of approved make 32 mmwaste pipe complete including cutting & making good the wall : size 550 mm x 400 mm dia for counter top 47 p & f lst quality wvc urinal (is:2556 mark) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete : wvc flat back half stall urinal size 580x380x350 mm/ angle back 450x375x350 type liped front. 48 providing and fixing stainless steel a isi 304 (18/8) kitchen sink & is 13983 with c.i. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : stainless steel kitchen sink without drain board 470x420mm bowl depth 178 mm 49 p & f g.i. pipeswith g.i. fittings (is:1239 mark) & m.s. clamps including cutting and making good the walls and floors : (internal work ) medium duty pipes : internal work : 50 a) exposed on walli) 15 mm dia nominal bore 51 ii) 20 mm dia nominal bore 52 p & f bib cock (is : 8931 mark), superior quality of approved make : c. p. brass long body, 15mm nominal bore weight not less than 690 gm 53 p & f stop cock(is :8931 mark),superior quality & ofapproved make: 54 a) c.p. brass 15mm nominal bore. 55 b) cp brass concealed stop cock 15mm. 56 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. : c.p. inlet connection 15 mm brass (is:8931 marked). 57 p & f pvc storage tank (is:12701 marked indicating the bis license no.) of approved make with cover, 25 mm dia 1 m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including placing on terrace( at all floors),making connection etc. complete of approved design. details of cost for 500 litre 58 construction of open surfacedrain with 112mm thick brick masonry in cm 1:4,110mm thick base concrete 1:5:10, 37mm thick m 15 grade c.c. flooring ,12mm 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earth complete as per approved design/drawing : 150mm drain,225mm av. depth. 59 part b electric work 60 wiring of light point/ fan point/ exhaust fan point/ call bell point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade (is:694)and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694)in recessed isi markedmms ( is:9537 p iii ) vergin material pvc conduit & its all accessories( j.b. , bends etc.) , round tiles,18 swg hot dipped galvanized modular box with earth terminal, 6 a modular switch, modular face plate with grid plate, 3 pin ceiling rose / lamp holder/ 3 pin connector , screws etc, making connections,all as per pre approved by engineer in charge, testing etc. complete as required.for specification of copperconductor,phenolic laminated sheets & electrical/ wiring accessoriesrefer chapter e 04, e 05 & e 07 . for additional technical parameters of products/ work, referannexure a attached with this bsr . 61 (a) short point (up to 3 mtr.) 62 (b) medium point (up to 6 mtr.) 63 (c) long point (up to 10 mtr.) 64 wiring of 3/5 pin 6 amp. light plug point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv grade (is:694)and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694)in recessed isi markedmms ( is:9537 p iii ) vergin material pvc conduit & its all accessories( j.b. , bends etc.) , round tiles, 18 swg hot dipped galvanized modular box with earth terminal, 6 a modularswitch, 3/ 5 pin 6 a modular socket, modular face plate with grid plate, screws etc,all as per pre approved by engineer in charge,making connections, testing etc. complete as required.for specification of copperconductor,phenolic laminated sheets & electrical/ wiring accessoriesrefer chapter e 04, e 05 & e 07.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 65 (a) on board 66 (b) medium point (upto 6 mtr.) 67 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked (is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.99% purity copper, class 5 stranding in acc. to iec 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a ,flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4,, in existingsurface or recessed pvc/ ms conduit/casing capping includingall as per pre approved by engineer in charge,making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products/ work, referannexure a attached with this bsr . 68 (a) 2 x 2.5 sqmm + 1 x 1.5 sqmm 69 (b) 2 x 4 sqmm + 1 x 2.5 sqmm 70 providing & fixing of 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c tripping characteristic as per type of load andsite requirement) 4kv impulse withstand voltage,as per pwd specification for electrical works with isi marked is 8828(1996) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec,minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 71 contact protection and fitted withexisting distribution board/sheets, min. operation 20,000 upto 32 a rating and 10,000 upto 63 a, 5000 for 80 a ratingincluding making connections, testing etc. as required.. oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr.(a) single pole mcb6 a to 32 a rating 72 providing & fixing of 240/415 v isolator as per pwd specification for electrical works with isi marked is:13947 iii/conforming to iec 60947 3, suitable for ac22a utilization catagory, 4kv impulse withstand voltage,true contact indication,red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm. , label holding facility , ip 20 contact protection and fitted with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : double pole isolator : a) 63 a rating 73 providing & fixing of ik09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thickdistribution board as per pwd specificationfor electrical works isi marked conforming to is 13032 & is 8623 / conforming to iec 61439 3. phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal dbterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : ip 43 double door (single phase) : (a) 6 way (6 o/g + 2 i/c) 74 s&f following sizes (dia.) of isi marked mms ( is:9537 p iii ) vergin material pvc conduit as per pwd specification for electrical works along with its accessories (is: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. all relative and latest acceptance tests reports by any nabl accredited lab for the conduit shall be submitted before execution & all as per pre approved by engineer in charge. for additional technical parameters of products/ work, referannexure a attached with this bsr : mms (is : 9537 p iii) pvc conduit : 25 mm. 75 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un armoured / armouredaluminiumcable of 1.1 kv grade as per pwd specification for electrical worksin existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below: 76 (a) material : h4 gradealuminium conductor of purity >99.6 %& as peris:1554 p i / is :7098 p i 77 (b) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 (part 0 to 64 ) for testing procedures . 78 (c)oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities forcables . appropriate type test certificate / oem test report shall be submitted .all above as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : i) un armoured : a) 10 sqmm 2.0 core 79 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from polycarbonate /extruded aluminium powder coatedhousing with in built driver, power consumption of18w/20w ,system lumen efficacy = 120 lm/watt output, internal surge protection of 2.5 kv with short & open circuit protection ,thd < 10% ,p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k/ 5700°k /6000°k/6500°k (as per ansi bin) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. 80 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer annexure a attacheded with this bsr.a) 4 led tube shape fixture 18/20 w (polycarbonate base) 81 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 18 swg with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch (is :3854) and 3/5 pin 16 amp. socket outlet (is:1293) [ as per detailed in respective item in bsr] , making connection , testing , etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 82 supply installation testing & commissioning of iso certified manufacturer mademonoblock motor pump set isi marked (is:9079 2002) with tefc motor, motor should be ie2 class as per iec 60034 2 1: 2007, iec 60034 30: 2008,& is12615:2011. with stainless steel impellor, stainless steel shaft, mechanical seal, single/three phase ( 240 440 v ) permanent split capacitor type (psc), fitted with thermal overload protection, . including cost of hardware etc on existing platform complete. pump shall have following hp rating, phase, head, minimum discharge respectively complete in all respect. appropriate type test certificate / oem test report shall be submitted. all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : 0.5 hp, 1 ø, (3 18)mtr, (100 26) lpm 83 providing & fixing ofof m.s. j hook of standard design made out of 16 mm dia. m.s. round bar and fixed withcement concrete mortar with required support as required. 84 providing & fixing of modular type step fan regulator duly isi marked (is :11037) as per pwd specification for electrical works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width of 1 module switch toggle( push part ) should not less then 20mm,includingall as per pre approved by engineer in charge,making connections, testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : 5 step fan regulator 100 watt 2 module 85 providing & fixing of following modular accessories as per pwd specification for electrical works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width of 1 module switch toggle( push part ) should not less then 20mm,includingall as per pre approved by engineer in charge,making connections, testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : blanking plate. 86 widening & upgradation of gate no. 01 & 02 with check post at kums sri ganganagar (f&v) 87 part a (civil work) 88 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge : 1: 3: 6 or richer mix. 89 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge : in cement mortar 90 removing mortar from bricks and cleaning bricks including stacking within a lead of 50 meters (stacks of cleaned bricks shall be measured) : from brick work in cement mortar. 91 disposal of earth, sand, gravel, u/s kankar, lime, flyash, morrum, manure or sludge up to 5000 mtr. beyond ist 50 mtr. lead (including loading and unloading) 92 demolishing r.c.c. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. 93 demolishing mud phuska/ lime dhar/ kharanjain terracing and disposal of unserviceable material within 50 meters lead. 94 dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 95 repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : with cement mortar 1 :4 ( 1 cement : 4 coarse sand) 96 dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead : of area 3 square meter and below. 97 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter : all kinds of soils 98 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 99 a) m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 100 c) m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 101 brick work with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 infoundation and plinth with : cement mortar 1 : 6 (1 cement : 6 coarse sand) 102 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. : m20 grade nominal mix /design mix 103 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 104 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc : m20 grade nominal mix / design mix 105 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. : m20 grade nominal mix / design mix 106 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 107 brick work with common burnt clay f.p.s.(non modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1 : 6 (1 cement : 6 coarse sand) 108 honeycombbrickworkhalfbrickthickwithcommon burnt clay f.p.s.(non modular) bricksofclassdesignation7.5uptofloor five level in : cement mortar 1 : 4 (1 cement : 4 coarse sand) 109 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level : cold twisted deformed bars (is : 1786). 110 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 111 plaster on new surface on wall in cement sand mortar 1:6 including racking of joints etc. complete fine finish : 112 a) 20mm thick 113 b) 12mm thick 114 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 115 grading roof for water proofing treatment withwater proffing compound : cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 116 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting ,grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 117 kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : for area of each slab from 901 to 2000 sq.cm. 118 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 119 direction and place identification signs with size more than 0.9 sqm size board. (providing anderecting direction and place identification retro reflectorised sign asper irc: 67 made of ncasulated lens type reflective sheeting vide clause801.3fixed over aluminium sheeting ,2mm thick with area exceding 0.9 sqm supported on a mild steel angle iron post 75mm x75mm x6mm ,2 nos . firmly fixed to the ground by means of properly designed foundation with m 15 grade cement concrete45cm x 45 cm x 60 cm , 120 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 121 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 122 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 123 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect : on new work 124 providing&layingpopcorniceofrequireddesign&patterninceilingincludingnailing&scafolldingetc.completewithfinefinishing of size : 50mm x 50mm. 125 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 126 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). 127 a) for fixed portion : anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) 128 b) for shutters builtup standard tubular sections of openable doors , windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately) : anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) 129 providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge.(cost of aluminium snap beading shall be paid in basicitem.) : with float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 130 providing and fixing double action hydraulic floor spring of approved brand and manufacture is : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece m.s. : with stainless steel cover plate 131 providing and fixing 100mm brass locks (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 132 providing and fixing of double leaf steel shutterfor cupboard, the frame is made of pressed steelisi section 80x25 mmx1.25 mm thickwith 1.00 mm ms sheet to spot welded including holdfasts of 15x3mm, ms oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc completeincluding applying priming coat of approved steel primer of red oxide zinc chromate andspray painting in approved shade with deco paint of approved quality complete as per direction of engineer in charge 133 providing and fixing of reinforced ferro cement drain covers designed for a & aa class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted m.s. plate, rim and m.s. lifting hooks, admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. : for class aa loading : span 300 to 450mm standard size 600x800mm 134 providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, y and h aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge : anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer). 135 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion.(i) single socketed pipes : type b, 110 mm diameter. 136 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion : single bend w/o door 87.5 deg. : 110mm dia 137 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12mm (av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete : south (red/cholate colour) : 1501 cm2 to 3600 cm2 tiles. 138 providing and fixing clamps of required size & shape in rcc/ cc backing with cement mortar 1:2 ( 1 cement :2 coarse sand) including drilling necessary hole in stones and embedding the cramp in the hole : stainless steel cramps. 139 p & f wvc wash basin (ist quality is:2556 mark) of approved make with c.i. brackets duly painted 1 no. 15 mm c.p. pillar cock (is:8934 mark) & 32 mm c.p. brass waste coupling of approved make 32 mmwaste pipe complete including cutting & making good the wall : size 450mm x 300mm : size 550 mm x 400 mm dia for counter top 140 p & f lst quality wvc urinal (is:2556 mark) with 25mm dia g.i. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete : wvc flat back half stall urinal size 580x380x350 mm/ angle back 450x375x350 type liped front. 141 p & f g.i. pipeswith g.i. fittings (is:1239 mark) & m.s. clamps including cutting and making good the walls and floors : (internal work ) medium duty pipes : internal work : 142 a) exposed on walli) 15 mm dia nominal bore 143 ii) 20 mm dia nominal bore 144 p & f bib cock (is : 8931 mark), superior quality of approved make : c. p. brass long body, 15mm nominal bore weight not less than 690 gm. 145 p & f stop cock(is :8931 mark),superior quality & ofapproved make: 146 a) c.p. brass 15mm nominal bore. 147 b) cp brass concealed stop cock 15mm. 148 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. : c.p. inlet connection 15 mm brass (is:8931 marked). 149 p & f pvc storage tank (is:12701 marked indicating the bis license no.) of approved make with cover, 25 mm dia 1 m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including placing on terrace( at all floors),making connection etc. complete of approved design. details of cost for 500 litre 150 construction of open surfacedrain with 112mm thick brick masonry in cm 1:4,110mm thick base concrete 1:5:10, 37mm thick m 15 grade c.c. flooring ,12mm 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earth complete as per approved design/drawing : 150mm drain,225mm av. depth. 151 part b electric work 152 wiring of light point/ fan point/ exhaust fan point/ call bell point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade (is:694)and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694)in recessed isi markedmms ( is:9537 p iii ) vergin material pvc conduit & its all accessories( j.b. , bends etc.) , round tiles,18 swg hot dipped galvanized modular box with earth terminal, 6 a modular switch, modular face plate with grid plate, 3 pin ceiling rose / lamp holder/ 3 pin connector , screws etc, making connections,all as per pre approved by engineer in charge, testing etc. complete as required.for specification of copperconductor,phenolic laminated sheets & electrical/ wiring accessoriesrefer chapter e 04, e 05 & e 07 . for additional technical parameters of products/ work, referannexure a attached with this bsr . 153 (a) short point (up to 3 mtr.) 154 (b) medium point (up to 6 mtr.) 155 (c) long point (up to 10 mtr.) 156 wiring of 3/5 pin 6 amp. light plug point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv grade (is:694)and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694)in recessed isi markedmms ( is:9537 p iii ) vergin material pvc conduit & its all accessories( j.b. , bends etc.) , round tiles, 18 swg hot dipped galvanized modular box with earth terminal, 6 a modularswitch, 3/ 5 pin 6 a modular socket, modular face plate with grid plate, screws etc,all as per pre approved by engineer in charge,making connections, testing etc. complete as required.for specification of copperconductor,phenolic laminated sheets & electrical/ wiring accessoriesrefer chapter e 04, e 05 & e 07.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 157 (a) on board 158 (b) medium point (upto 6 mtr.) 159 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked (is:694) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.99% purity copper, class 5 stranding in acc. to iec 60228 forlower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a ,flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4,, in existingsurface or recessed pvc/ ms conduit/casing capping includingall as per pre approved by engineer in charge,making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products/ work, referannexure a attached with this bsr . 160 (a) 2 x 2.5 sqmm + 1 x 1.5 sqmm 161 (b) 2 x 4 sqmm + 1 x 2.5 sqmm 162 providing & fixing of 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c tripping characteristic as per type of load andsite requirement) 4kv impulse withstand voltage,as per pwd specification for electrical works with isi marked is 8828(1996) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec,minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted withexisting 163 distribution board/sheets, min. operation 20,000 upto 32 a rating and 10,000 upto 63 a, 5000 for 80 a ratingincluding making connections, testing etc. as required.. oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr.(a) single pole mcb6 a to 32 a rating 164 providing & fixing of 240/415 v isolator as per pwd specification for electrical works with isi marked is:13947 iii/conforming to iec 60947 3, suitable for ac22a utilization catagory, 4kv impulse withstand voltage,true contact indication,red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm. , label holding facility , ip 20 contact protection and fitted with existing distribution board / sheetincluding making connections, testing etc. as required. oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : double pole isolator : a) 63 a rating 165 providing & fixing of ik09 recessed/surface mounting heavy duty horizontal type sheet steel of 1.6 mm thickdistribution board as per pwd specificationfor electrical works isi marked conforming to is 13032 & is 8623 / conforming to iec 61439 3. phosphatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar,masking sheet, including making internal dbterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : ip 43 double door (single phase) : (a) 6 way (6 o/g + 2 i/c) 166 s&f following sizes (dia.) of isi marked mms ( is:9537 p iii ) vergin material pvc conduit as per pwd specification for electrical works along with its accessories (is: 3419 ) as requiredinrecess includingcutting the wall, covering conduit and making good the same as required. all relative and latest acceptance tests reports by any nabl accredited lab for the conduit shall be submitted before execution & all as per pre approved by engineer in charge. for additional technical parameters of products/ work, referannexure a attached with this bsr : mms (is : 9537 p iii) pvc conduit : 25 mm 167 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un armoured / armouredaluminiumcable of 1.1 kv grade as per pwd specification for electrical worksin existing rcc / hume / stoneware / pvc pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below: 168 (a) material : h4 gradealuminium conductor of purity >99.6 %& as peris:1554 p i / is :7098 p i 169 (b) conductor shall have electrolytic aluminium confirming to is 8130, is 3975 1999for armouring of cables in armoured cable items , is 5831 for sheath, is 10810 (part 0 to 64 ) for testing procedures . 170 (c)oem must have iso 9001 & 14001 certifications for quality assuarance & its own in house nabl lab setup for all testing facilities forcables . appropriate type test certificate / oem test report shall be submitted .all above as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : i) un armoured : a) 10 sqmm 2.0 core 171 providing & fixing of ip20 smd mid power led batten type integrated light fixture made from polycarbonate /extruded aluminium powder coatedhousing with in built driver, power consumption of18w/20w ,system lumen efficacy = 120 lm/watt output, internal surge protection of 2.5 kv with short & open circuit protection ,thd < 10% ,p.f.=0.95, cri >80 , life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k/ 5700°k /6000°k/6500°k (as per ansi bin) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing on housing. 172 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer annexure a attacheded with this bsr.a) 4 led tube shape fixture 18/20 w (polycarbonate base) 173 supplying and fixing of power plug point with modular accessories as per pwd specification for electrical works, on hot dipped galvanized modular box of 18 swg with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofisi marked modular 16 amp. switch (is :3854) and 3/5 pin 16 amp. socket outlet (is:1293) [ as per detailed in respective item in bsr] , making connection , testing , etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr . 174 providing & fixing of iso certified company made beestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanas per pwd specification for electrical works, conforming to is:374 2019, & is:1885 p v 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : 1200 mm sweep bee 3 star rated (service value >=5.0 to< 5.5 ) 175 providing & fixing ofof m.s. j hook of standard design made out of 16 mm dia. m.s. round bar and fixed withcement concrete mortar with required support as required. 176 providing & fixing of modular type step fan regulator duly isi marked (is :11037) as per pwd specification for electrical works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width of 1 module switch toggle( push part ) should not less then 20mm,includingall as per pre approved by engineer in charge,making connections, testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : 5 step fan regulator 100 watt 2 module 177 providing & fixing of following modular accessories as per pwd specification for electrical works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width of 1 module switch toggle( push part ) should not less then 20mm,includingall as per pre approved by engineer in charge,making connections, testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : blanking plate. 178 providing & fixing of ip40 led recessed / surface mounted, round / sqaure non dimmable back lit smd mid power led downlight with die cast aluminum housing & heat sink for heat dissipation with uv stabilized non yellowish diffuser with internal/ external bis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% and in compliance to iec standards. system lumen efficacy of = 120 lm / watt, thd < 10 % ,p.f.=0.95, cri >80,life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k/ 5700°k /6000°k/6500°k (as per ansi bin) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c.). manufactures word mark/ name engraved/ embossing/ screen printing onhousing. 179 oem must have its own in house nabl lab setup for all testing facilities for led fixtures. (lm79/lm80) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer annexure a attacheded with this bsr. : recessed mounting : led downlight 18/20w 180 providing & fixing of ik07 ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum lm6/ adc12 material with heat dissipation fins on housing with uv stabilized pc/toughened glass cover (uv stablzation report submitted for uv cover ) and secondary lens on each led & should be smd type . the system level luminaire efficacy >=120 lm/ wtwith high power leds is to be usedand potted driver must be potted & has a unique bis r number withinput voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety ,input frequency 50hz±3% power factor >0.95 driverefficiency >85%,thd(i) <10%humidity 10% to 90% rh working temp 5c to 45c .driver current <1000ma shown in lm79 report. the luminaireshall be bis certified and t.c. certified. life expectancyequal or more than 50000 burning hrs with minimum 70% lumen maintened ,color 181 rendering index >70 and cct 5700k +355k. surge protection shall be min = 4 kv internal and min 10 kv external. driver should be phase to phase protection of 440 v for 4 hrs.manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced. oem must have its own in house nabl lab setup for all testing facilities forled fixtures.(lm79/lm80) certificate/ report with liable warranty of product/accessories from oem shall be submitted.all as per pre approved by engineer in charge.for additional technical parameters of products/ work, refer annexure a attached with this bsr : led street light fixture 60 watt ...

Urban Improvement Trust - Rajasthan

32265199 various civil works and maintenance works in sub division i of division ii b ( arc ) civil worksclearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000m from road boundary. (morth specification : clause 201).by manual means : in area of light jungle 2 clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 silt clearance of drains, channels and canals with lift 1.5 mtr. and lead up to 50 mtr. 4 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 5 add extra over item no. 1.8 and 1.9 (sechedule item no 1) for every additional lift of 1.5 m or part thereof : 6 above 1.50 to 3.00m 7 m 35,60mm thick to be used in light traffic (light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 kn laden weight, or an wquivalent up to 0.5 million standerd axles (msa) for a design life of 20 years (a standerd axle is defind as a single axle load of 81.6 kn ) like pedestrain plazes, shopping complexes ramps, car parks, office drveways , housing colonies , office complexes , rural roads with low volume traffic ,fram houses, beach sites, tourist resorts, local authority footwys ,residential roads, etc. 8 category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 9 random rubble dry stone kharanja under floor. 10 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 11 m10 grade nominal mix, 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 13 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 14 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix 15 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 16 anti termite treatment of floor using imidacloprid 30.5% ec non repellent, odorless, low dose, environimentally safe terniticide with rapid action non corrosive stain free manufactured by bayer or equivalent company by drilling 12mm diameter holes 300mm apart injecting the emulsion as specified by the manufacturer and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area dpe 12mm dia termitube system with required number of junction boxes are to be installed. the termitube will run all along the perimeter wall both inside and outside. in the middle area the termitube to be installed at an interval of 1.00 mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. after successful testing of termitube, pesticide emulsion of imidacloprid 30.5% ec mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. the plinth area of the area treated will be measured for payment. 17 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 18 columns, pillars, posts and struts etc. 19 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in: 20 cement mortar 1:6 ( 1 cement : 6 sand). 21 cement mortar 1:4 ( 1 cement : 4 sand). 22 cement mortar 1:3 ( 1 cement : 3 sand). 23 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : 24 cement mortar 1:3 ( 1 cement : 3 sand). 25 cement mortar 1:4 ( 1 cement : 4 sand). 26 cement mortar 1:6 ( 1 cement : 6 sand). 27 pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 28 flush / ruled/ struck or weathered pointing. 29 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete and not applying 2 coats of hot bitumen complete as per specifications. 75mm thick 30 50mm thick 31 75 mm thick 32 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 33 suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 34 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 35 thermo mechanically treated bars (conforming of relevent is code) 36 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in : 37 cement mortar 1 : 4 (1 cement : 4 coarse sand) 38 cement mortar 1 : 6 (1 cement : 6 coarse sand) 39 half flyash brick masonry in foundation & plinth using flyash bricks of designation 75 40 cement mortar 1 : 4 (1 cement : 4 coarse sand) 41 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 42 12mm thick. 43 20mm thick. 44 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 45 making grooves as per design in plaster 10mm to 20mm wide. 46 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 47 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 48 two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 49 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 50 new work 51 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 52 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 53 two or more coats on new work 54 150cm high fencing with angle iron 50x50x6mm. placed at every 3mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with g.i. staples including earth work in excavation etc. complete. 55 grading roof for water proofing treatment withwater proffing compound 56 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 57 providing and fixing pressed steel door frames confirming to is 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applyinga coat of approved steel primer after pre treatment of the surface including filling with cc 1:2:4(m15 grade) complete as directed by engineer in charge : 58 profile b 59 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 30 mm thick . 60 decorative teak veneer both side 61 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). : for fixed portion 62 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 63 providing and fixing of plastic shutter infill made from extruded multi chamber hollow p.v.c. section having cross section of 200 x 20 x 1 mm and shutter frame made from extrude p.v.c. section in the configuration of double walled c section having an overall cross section of 40 x 37 mm and door fittings such as hinges, aldrop, handles, stopper, locking bolt will be provided. 64 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 65 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 66 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 67 providing and fixing superior quality like hardvyn or equivalent hydraulic door closure. 68 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 69 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 70 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : 71 good quality south black above 3601 cm2 slabs 72 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 73 granite work (full edge moulding ) 74 p & f 1st quality heavy duty vitrified glazed mat tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. 75 size600 mm x 1200mm 76 providing & fixingbrown kota/ mandana / dholpur/ slate stone incladding / flooring structuralbase with white cement & tinex chemical& ss clamp and fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attachedcomplete in all respect as per direction of engineer in charge & architect with all lead & lift. the stone measurement will be done of outer most dimension. thickness of stone 25 30mm. 77 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 78 25 mm thick slab. 79 s/f of fire bricks on edg flooring with fire bricks suitable for 1300 degree centigrade safe working temperature as per is :8 specification laid on & filling of joint by fire resistant mortar/adhesive of required thickness as per directed on a bed of 20 mm thick 1:2 cement mortar of bricks 9 x 4.5x 3 (rate approved year 2008) 80 providing and fixing of glass moisac tiles ( bisseze marke ) size 20 x 20 x 4 mm applied with aaproved adhesive as per specification and direction of engineer in charge 81 providing and fixing staincase railing 90 cm high from nosing of made offollowing specifications. 82 50 mm outer dia (2 mm thick) s.s. pipe hand rail. 83 40 mm outer dia (2 mm thick) s.s. pipe baluster @ 1.00 mtr. 84 4 nos. 20 mm fs. s pipe intermediate runners parallel to hand. 85 s.s. shoe 1.60 mm thick 75 mm outer dia. at each baluster 86 baluster to be welded with s.s. plate 50 mm dia (3 mm thick) anchored in c.c. block with suitable dash fastners 87 50 mm dia & 2 mm thick s.s. pipe for start and end vertical ornamental posts to be provided as per direction of engineer in charge 88 the stainless steel work shall be brushed steel finish with all joints/welds properly grinded to final finish. the stainless steel shall be 304 grade and shall confirm to relevant i.s. 89 providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.extra if square,rectangular hollow tubularsections are used or grill made by flats only 90 decorative plaster work with spectrum textured coating as per approved colour and shade complete as per manufactures specifications. 91 grit textured @ 2.5 to 3.0 mm thick. 92 ornamental cement plaster in cement sand mortar1 : 4 making kangooras etc. as per jaipurpractice. 93 supplying and fixing machine cutdressed 75 mm pinksand stone (bansi paharpur) dasa/ coping wth ornamental shape having moulding and pan shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 94 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 95 0.63 mm thick with zinc coating not less than 275 gm/m2 96 supply & spreading ofgood earth at site complete including loading unloading & transportation etc. 97 supply of dry manure including loading unloading,transportation & stacking at site. 98 farm yard manure(organic) 99 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 100 laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc.(cost of manure or extra good earth to be paid seperately) maintenance of lawns for 30 daysor more till the grass forms a thick lawns free from weeds & fit fo 101 in rows 7.5 cms. apart in either direction 102 construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8 10 tonne to meet requirement of table 300 2 including cost of compensation for earth taken from private land with lead upto 1 km as per morth specification : clause no. 305. 103 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 104 p & f european type white glazed vitreous china 1st quality double syphonic w.c (is :2556 mark) with p or s trap including cutting and making good the wall and floor 105 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor: 106 size 580x440mm. 107 p & f low level flushing cistern of 10 ltr. capacity (is : 2556 mark) o9f approved make with colplete fitting ,c.i. brackets duly painted , brass ball cock with ball, (is :1703 mark)complete including cutting and making good the wall. 108 wvc with c.p. brass bend. 109 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) &32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall.: 110 size 550 mm x 400 mm dia for counter top 111 1.0 mm thick salem stainless steel aisi 304 & is 13983 1994kitchen sink of approved make (nirali, neel – kanth, jaina, faber castell )with large waste coupling. 112 (24 x 18 x 8) (20x16x8) 113 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. 114 c.p. inlet connection 15mm.brass (is : 8931 marked) with 37 cm long pipe and nut. 115 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 116 1000 litres capacity. 117 providing and fixingsuperior quality (jaguar contiental ) cp brassfittings complete as per direction of ei 118 bib cock with long thread 15 mm nominal size 119 brass / gunmetalhalf turnwt. 1 kg.ofapprovedquality / make,25mmnominalbore. 120 p & f full way valve (is:778 mark) or wheel valve of approved make 121 gun metal 32mm nominal bore. 122 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 123 20mm nominal outer dia pipes 124 32mm nominal outer dia pipes 125 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 126 110 mm dia 127 160 mm dia 128 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: 129 coupler (socket) 130 110mm dia 131 160 mm dia 132 plain tee 133 110mm dia 134 160mm dia 135 door tee 136 110mm dia 137 bend 45 138 110mm dia 139 vent cowel 140 110mm dia 141 door bend (left & right) 142 110mm dia 143 pipe clip 144 110mm dia 145 plain floor trap 146 110mm dia 147 p trap 148 110mm dia 149 socket plug 150 110mm dia 151 door cap 152 110mm dia 153 construction of chamber in all type of soil with 300 mm thick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 154 do size 450 x 450mm depth upto0.5 m cement cover with frame 155 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,hot dipped galvanized modular box with earth terminal, 6 a modular switch,modular plate with grid plate,screws,making connections, testing etc. as required. 156 short point (up to 3 mtr.) 157 medium point (up to 6 mtr.) 158 long point(up to 10 mtr..) 159 wiring of twin control light point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper earth conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 160 medium point (up to 6 mtr) 161 wiring of 3 pin 6 amp light plug point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp switch & 6 amp socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 162 on board 163 medium point (up to 6 mtr) 164 long point (up to 10 mtr) 165 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. 166 25 mm 167 32 mm 168 50 mm 169 supplying and fixing of power plug point modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. switch and socket outlet, making connection , testing , etc. as required. 170 p&f metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without mcb) including making connections, testing etc.as required 171 single / double pole(three pin) 172 32 a 173 providing & fixing isi marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. 174 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 175 2 x 2.5 sq. mm. + 1x1.5sqmm 176 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 177 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 178 single pole mcb 179 6 a to 32 a rating 180 four pole mcb 181 40 a 63 a rating 182 four pole mcb 183 6 a to 32 a rating 184 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required. 185 double door (single phase) 186 12 way 187 double door (three phase) 188 8 way 189 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 190 25.0 sq.mm 191 4 core 192 50.0 sq.mm 193 120.0 sq,mm 194 3.5 core 195 150.0 sq,mm 196 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 197 3.5 x 120.0 sq.mm 198 4 x 25.0 sq.mm 199 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 200 10.0 sq.mm 201 4 core 202 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty copper lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 203 4 x 10.0 sq.mm 204 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of crca sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadethe panel having pu/ neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate m.s. base channel ,hinged door with locking arrangement for equipment/switchgear. thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. load bearing structure shall beof 2.0 mmthick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from cpri approved fabricator) 205 supplying and fixing of aluminium / copper bus barby means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. 206 electrolytic grade aluminium bus bar 207 sf of (0 500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 208 analog type ( 96mm x 96mm ) 209 sf of ct operated direct reading typeampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 210 analog type ( 96mm x 96mm ) 211 below 500 a 212 sf ofcurrent transformer, with all necessary support in existing panel including connection etc. as required . 213 up to 150/5 ratio, 10 va, class 1 accuracy 214 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc.as required . 215 sf of ct linked selector switch of 10 aforampere meter (4 position ) including making connection etc.as required . 216 sf of110/220 v, led (22.5 mm dia ) indicatinglamp with integral circuit, terminal block, including connection etc. as required. 217 red/yellow/green colour 218 supplying and drawing fr pvc insulated & unsheathed flexiable copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 219 1 x 1.5 sq.mm 220 1 x 2.5 sq.mm 221 1 x 4.0 sq.mm 222 1 x 6.0 sq.mm 223 sitc of self healing mpp/mp type shunt capacitor (banks) conforming to is:13340 41 / iec :831 1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.5 watt per kvar . including making connections with suitable capacity conductors/cables testing etc. as required. 224 heavy duty three phase 440 v , 50 hz capacitor (bank) 225 sitc of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar,metering facility as required. 226 6 to 8 stage 227 sensitivity upto 50 milli amp 228 p & f ofcam operated rotary switchs on existing panel with 2 way and off postion 229 one pole 230 16 amp 231 p & f of440 volt 3 pole capacitor(ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to is:13947 4 1/iec:947 4 1, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 232 up to 6 kvar 233 7 to 10 kvar 234 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 235 triple pole mcb 236 6 a to 32 a rating 237 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating: 238 open execution type 239 200 amp 240 sitc of quick make and quick break4 polecurrent limiting mccb having following current rating, short circuitbreaking capacityat 440/415 v, 50 hz; o/l & s/c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 241 with thermal magnetic release 242 up to 160 amp , 25 ka, adjustable o/l & fixed s/c setting, ics = 100 % icu 243 plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 244 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 245 8 swg copper wire 246 providing & fixing of heavy duty capacitor start 900/1400 rpm single phase isi marked exhaust fan is:2312 marked in existing opening making connections, testing etc. as required 247 300 mm sweep (900/1400 rpm) 248 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 249 1400 mm sweep 250 p & f of ip 20 led tube light 20 watt with external batten made from crca sheet steel suitable to replace t 8/t 12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 lm/ watt minimum expected life time of 25000 burning hours, cct 5700 k ansi, cri 80, driver efficiency >85%, life expectancy of driver rnin 30000 hrs. pf 0,95 at full load/ 230 volt ac. 251 p & laying xlpe insulated is:7098/ii/85 of group1 and approved make h.t.cable for working voltage 11 k.v.earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 252 3 core 185.0 sq.mm ...

Urban Improvement Trust - Rajasthan

32265166 various civil work and repairing work in sub div i of div. ii a area. ( arc ) civil works earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 2 earth work in excavation by mechanical means (hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed: all kinds of soil 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 4 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level.m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 5 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 6 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete as per specification . 50mm thick. 7 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 8 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 50mmthickwith20mmthicknominalsizeaggregate. 9 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 10 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 11 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 12 m 40,80mm thick to be used in medium traffic (medium trafficis defind as a daily traffic of 150 450 commercial vehicles exceeding 30 kn laden weight , or an equivalent of 0.5 to 2.0 msa for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc. category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 13 add extra over rates of 1a to e, if colored paver blocks are used 14 supply & stacking good soil of earth at site complete including loading unloading & transportation etc. good soil of earth 15 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 16 s & fcc 1:2:4 (m15) precast kerb on dand upto 60 cm length over 20 mm thick base of cement mortar 1:6 including jointing, earthwork, painting and jointing with cement mortar 1:4 of size.15 × 40 cm 17 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 2001 to 5000 sq.cm : 25 mm thick slab. 18 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 19 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 20 add extra if square, rectangular hollow tubular sections are used. 21 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 22 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : one or more coats on old work. 23 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: on new surface. 24 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: on old surface. 25 providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with : stone slab 40 to 50 mm thick average. 26 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 27 flyash brick masonry with flyash bricks of class designation 75infoundation and plinth. cement mortar 1 : 6 (1 cement : 6 coarse sand) 28 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 29 chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles includingrubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) light shade using shade cement. 30 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 31 providing and laying reinforced cement concrete pipes np 3 for culverts including jointing ends and fixing collar with cement mortar 1:2. (morth specification : clause 1000/2900). 32 300 mm dia 33 600 mm dia 34 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of :jhansi (red/chocolate colour) above 3601 cm2 slabs 35 transportation of excavated of earth from site including loading unloading etc. complete with all lead and lift. lead upto 5 km. 36 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 37 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. new work 38 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 39 providing, laying and spreading of granular sub base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at omc, and compacting with vibratory roller to achieve the desired density, complete as per morth specification : clause no. 401. grading iii 40 p & f stone cladding / flooring works dressed bansi paharpur stone 25mm thick in traditional style used in cladding/flooring with pattern over 25 to 50 mm thick base in cm 1:6 including pointing with cement mortar 1:2 (cement : 2 stone dust) matche the shade of stone with joint thickness upto 1.5mm as per direction of engineer in charge. 41 single piece of stone element with carving work in bansi paharpur stone includes stone pillar, stone base, todies and thabi etc carving work as per direction of engineer in charge 42 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 43 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 44 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 4.0 sq.mm 4 core 45 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 6.0 sq.mm 4 core 46 p&f strip type fluorescent tube fitting fabricated from (crca) sheet and finished with powder coating/stove enamelled paint/ (extruded non corrosive uv resist ep channel) complete with accessories like (occb, starter, starter seat) / eb, rotor holder, terminal block duly prewired with copper conductor including making connection, testing etc. as required. (without tube) 1×36 watts with occb, group i 47 p&f fluorescent tube rod in existing fixtures as required. fluorescent powder coated 36/40 watts, group ii 48 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm sweep.group i 49 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) for fixed portion 50 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) 51 providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board grade i, type ii conforming to is : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with c.p. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer in charge. prelaminated particle board with decorative lamination on both sides. 52 providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge.(cost of aluminium snap beading shall be paid in basicitem.) with glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per is : 2835. 53 providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, y and h aluminium sec (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge. anodised aluminum (anodised transparent 81 dyed to required shade according to is : 1868. (minimum anodic coating of grade ac 15, anodizing to be got done from approved anodizer) 54 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a:30 mm thick commercial veneer both side 55 providing& fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade : sal wood grade i. 56 wiring of twin control light /fan / call bell point with 1.5 sq. mm nominal size fr pvc insulated unshethed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unslated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) of approved make in surface / recessed isi marked mms (is:9537 p iii) pvc conduit & its accessories, round tles, 18 swg m.s. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point, 6 a two way switch, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. short point (up to 3 mtr.) 57 (a) short point (up to 3mtr) 58 (b) medium point (up to 6mtr) 59 ( c ) long point (up to 10mtr) 60 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kg grade (is:694) of approved make in surface/ recessed isi marked medium duty pvc conduit & its accessories, hot dipped galvanized m.s modular box with earth terminal, screwless cage connectors for neutral looping in switch board , 6 a modular switch, 6 a modular socket, modular plate with grid plate, screws, making connections, testing etc. as required. on board 61 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 62 2 x 2.5 sq. mm + 1x1.5 sqmm 63 2 x 4.0 sq. mm + 1x1.5 sqmm 64 p & f following sizes (dia) of isi marked medium duty pvc coduit along with accessories in surface/ recessed using sadles, clamps, fastener, as required including cutting the wall and making good the same as required. group ii, 25 mm dia 65 s&f following sizesof isi marked ( is:14927 p ii ) pvc casing capping along with accessorieslike coupler, inner, outer, elbow, square box, tee etc. on surfacewith screws, expansionfastenersas required. 66 32 mm x 12 mm 67 50 mm x 20mm 68 cement concrete pavement of required thickness with 1:1.5:3 (1 cement:1.5 course sand : 3 graded stone aggregate 20 mm nominal size) including finishing complete. 69 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge. 1: 3: 6 or richer mix. 70 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge. in cement mortar. 71 cutting of construction joint/ longitudinal joint 4 to 6 mm. wideusing mechanical concrete cutter including cost of diamond bit cutting wheel and filling of bitumen sealingcompound in groove including cost of sealing compound.100 mm depth 72 repair to cement plaster in cement mortar 1 : 6 (1 cement : 6 fine sand) including removal of old plaster in regular shape and white or colour washing. 73 providing and fixing stone jali 40mm thick red/pink sand stone throughoutin cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali patterns to be cut square to jali slab without any chamfers etc: 74 supplying and fixing machine cut fine dressedred/pink sand stone dasa orcoping,with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 25mm thick 75 half flyash brick masonry in superstructure , above plinth level upto floor three levelusing flyash bricks of designation 75 cement mortar 1 : 6 (1 cement : 6 coarse sand) 76 random rubble dry stone kharanja under floor. 77 surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 mtr. and lift up to 1.5 mtr.:all kinds of soil 78 filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 79 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 80 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : walls (any thickness) including attached pilasters,buttressesplinthandstring course. 81 supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 82 50mm x 50mm x 3.15mm 83 providing stone slab covering over drains including filling of joints in cement sand mortar 1 : 3 with 35 mm thick cement concrete flooring 1 : 2 : 4 mix complete with good finish with :stone slab 100 to 150 mm thick average. 84 repair to stone masonary in cement sand mortar 1:6 with old and new stone. 85 repair to brick masonary in cement sand mortar 1:6 withnew brick. 86 filling expansion joint with bitumen filler in plain or reinforced cement concrete 25 mm width & 25 mm deep. 87 providing and laying water proofing treatment with thermalinsulation havingthickness of 2.5 3.0 mm over the existing r.c.c. roof by as per direction and satisfaction of engineer in charge and consisting of:(i) cleaning and washing of the existing roof including removing of loose material from the surface of cracks.(ii) widening and deepening of cracks to fill the approved crack filler as per direction of engineer in charge.(iii) application of one coat of approved sealing compound approved by engineer in charge with following specification or equivalent compound @ 0.17 litres per square meter with required brush as per direction of engineer in charge.(iv) application of the mesh approved by engineerin charge (made up of glass fiber , woven structure of leno make , reinforcing with alkali resistant coating having 10x10 mesh size, weight/sqm is 90gm to 120 gm and of 0.25 mm thickness including resin content (%) : 18% ) orequivalentand then application of coat of sealing compound approved by engineerin charge with specifications as narrated above ,without use of water @ 0.33 litre per square meter with brush and dryingof surface for24 hoursas perdirectionof engineerin charge. 88 providing and fixing aluminium composite panel ofapproved make 3mm thick with 0.5mm thick skin & pvdf coated approved shade for wall panelling. main framing work to be done using 50mmx25mmx1.6mm tubular section of approved make. stainless steel screw to be used to fix the acp panel to be fixed to the main frame with industrial adhesive tape and panel groove to be sealed with weather proof silicon sealant suitable for glass/aluminium etc. complete in all respect as approved by engineer in charge. 89 providing & fixing uv stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘j’ or ‘l’ hooks, bolts & nuts 8mm dia. g.i plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. the sheets shall be manufactured out of 2400 tex panel rovigs incorporating minimum 0.3% ultra voilet stabiliser in resin system under approximately 2400 psi and hot cured. they shall be of uniform pigmentation and thickness without air pockets and shall confoim to is 10192 and is 12866.the sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 90 5.0mm thick (wt. 8.4 kg./mtr. sq.) 91 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : cement mortar 1:6 ( 1 cement : 6 sand). 92 providing and fixing marble stone flooring table rubbed, 15 18 mm thick over 20mm (av.) thick base of cm 1:4 (1 cement : 4 coarse sand) jointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. white marble : makrana adanga. 801 cm2 to 1500 cm2 tiles 93 p & f g.i. pipes (internal work) with g.i. fittings excluding union (is:1239 mark) & ms clamps including cutting and making good the walls and floors: exposed on wall 94 15 mm dia nominal bore b class 95 25 mm dia nominal bore a class 96 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 97 4 x 10.0 sq.mm 98 4 x 16.0 sq.mm 99 sitc of 11 kv, 400/630 a, 20ka / 3 sec, out door,extensible type ring main unit (rmu) in suitable rcc foundation with 2 no. load break switch & 1 no. vcb / sf6 circuit breaker with over load, earth fault, short circuit relay, copper bus bar, earthing switch, mechanical on / off /earth indication, voltage presence indicator, ring core protection ct 2.5 va, 10p10 as per transformer rating, shunt trip coil, anti reflex operating handle, right angle boots etc. as required. 100 providing and fixing corrugated colour g.i sheet having thickness 0.50mm roofing fixed with g.i.j or l hooks bolts and nuts 8mm dia meetr with bitumen and g.i limpet washers or with g.i limpet washers filled with white lead and including over lapping of sheet complete ( upto a pitch of 60 degree) & excluding the cost of purlins rafters and trusses etc complete in all respect. 101 providing & fixing of hdpe pipe isi mark (is:4984/95) for water supply (suitable for submersible & jet pump) with required fittings 102 40 mm od6 kg / cm2 103 50 mm od6 kg / cm2 104 63 mm od6 kg / cm2 105 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 106 10.0 sq.mm 107 4 core 108 16.0 sq.mm 109 4 core 110 70.0 sq,mm 111 3.5 core 112 120.0 sq.mm 113 3.5 core 114 sitc of radial / mixed flow submersible motor pump sets isi marked (is:8034 1989) of approved make with required accessories including making connection suitable for t.w./ d.c.b./ open well. the job includes lowering ofriser pipe, g.i./h.d.p.e. pipe with rope, cables, installation of complete fitting and accessories, jointing of electrical cables up to switch board. all labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.150 mm diameter submersible pump shall havefollowing hp rating, phase, head, minimum discharge respectively. 115 5.0 hp, 3 ø, (32 52)mtr, (400 167)lpm 116 7.5 hp, 3 ø, (45 73)mtr, (400 280)lpm 117 10.0 hp, 3 ø, (64 104)mtr, (400 167)lpm 118 construction of tube well upto 100 meter depth and above in all type of rocks by dth system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casingpipes as per is : 2800 (part i & ii) 1979 specifications. the work would be completed after obtaining sand free water. the tube well should have a throughout bore as per nominal dia of casing pipe: 119 200 mm –do 120 supply of erw m.s. black casing pipe isi marked (is:4270/1992) of grade fe410 of following sizes at site of work. 121 nominal bore of pipe (mm) 200 122 testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per is: 2800 (part ii) 1979. 123 s & f tube well cover ofm.s.sheet (6mm thick) with nuts and bolts complete for casing size: 124 200mm dia 125 s & f m.s. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 126 installation of submersible motor pump set in tube well/open well complete ( labour charges only) including transportation of tripod, chain pulley block & any other material required for lowering purpose. 127 p/laying isi marked p.v.c. insulated submersible cable confirming to is:694 with flexible copper conductor including making connection etc. as required. 128 6.0 sq.mm 3 core flat / round ...

Maharana Pratap University Of Agriculture And Technology - Rajasthan

32106120 miscellaneous work at sc/ st hostel ctae, udaipur. earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. all kinds of soil. 14.22 cum 164.00 2332.08 6.1.7 2 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand ) 9.01 cum 3672.00 33084.72 14.9. 2 3 dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead.in cement mortar 0.54 cum 370.00 199.80 14.27 4 dismantling stone slab tarrazo chips flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead 10.10 sqm 41.00 414.10 5 providing and laying in position cement concrete including curing compaction etc . complete in specified grade excluding the cost of centering and shuttering. all work up to plinth level using crusher broken aggregate : 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 9.57 cum 2896.00 27714.72 11.44 6 random rubble dry stone kharanja under floor 12.60 cum 979.00 12335.40 3.2.3 7 providing and laying in position cement concrete including curing compaction etc . complete in specified grade excluding the cost of centering and shuttering. all work up to plinth level using crusher broken aggregate : m15 grade nominal mix ( with graded stone aggregate 20mm nominal size) 0.54 cum 3802.00 2053.08 3.19.3 8 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.110mm dia 15.00 mtr 196.00 2940.00 3.20. 9 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:110mm dia 0.00 a bend 90 2.00 each 110.00 220.00 b plain tee 2.00 each 136.00 272.00 10 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.75mm dia 10.00 mtr 119.00 1190.00 11 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:75mm dia 0.00 a bend 90 2.00 each 79.00 158.00 office of the estate officer maharana pratap university of agriculture & technology, udaipur name of work : miscellaneous work at sc/ st hostel ctae, udaipur. 1 (b) estimated cost of : rs. 1.78 lakh (c) amount of earnest money : @ 2% rs. 3560/ @ 1/2 % rs. 890/ 1 (a) name of contractor:…………………………………………………………………. rates based on : bsr 2019 of pwd circle udaipur 1 (f) period of completion : two months 1 (e) time & date for opening : time 2.00 p. m. date 18.05.2022 1 (d) time & date for receipt : time 12.00 noon date 18.05.2022 1 (c) tender fees : rs. 300/ 1 (g) special conditions g schedule b plain tee 2.00 each 89.00 178.00 7.6 12 providing and fixing ist quality mat finished ceremic tiles size 300 x 300 mm confirming to is: 13755 & is: 15622 colour such as white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete (including the cost of cement mortar bed 1:4). 9.03 sqm 734.40 6631.63 7.3+7.3 .4 13 providing and fixing ist quality standard white/ ivory,grey, fuma red brown, light green, light blue and other light shades glazed tiles of (confirming to is : 13753 & is 13622) of size 300 mm x 200 mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls & pillars ).add extra for using tiles of size 300 x 450 mm over item 7.3, 7.3.1 & 7.3.2 2.16 sqm 860.60 1858.90 9.40.3 14 providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3 mm including top cross laps inside and out sides welding, iron bolts, screws, clips etc. complete (excluding frame work) of size. welded mesh 25x25mmx16 gauge. 8.67 sqm 556.00 4820.52 9.13 15 providing and fixing t iron frames for doors windows and ventilators of mild steel tee sections, joints mitred and welded with 15x3 mm lugs, 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 188.55 kg 96.00 18100.80 1.41.1 16 p &f kitchen & lab. sink of approved make with c.i. brackets duly painted 40 mm c.p. waste coupling, c.p. brass chain with rubber plug, 40 mm g.i. waste pipe up to floor level complete including cutting and making good the wall & floor. fire clay glazed kitchen sink (i.s. marked) size 600 x 450 x 250 mm 1.00 each 3322.00 3322.00 7.2.3 17 providing and fixing granite stone slab thickness 16 18 mm mirror polished and machine cut in walls, pillars, steps, shelves, counter, floors etc. laid on 12 mm (av.) thick base of cement mortar 1:3(1 cement : 3 coarse sand) jointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of.south (red/choclate colour) above 3601 cm2 slabs 3.23 sqm 3192.00 10310.16 7.12.2 18 extra for providing edge moulding to 16 18 mm thick marble stone counters . vantities etc. over item no. 7.1 & 7.2 including machines polishing to edge to give high gloss finish etc. complete as per design approved by engineer incharge.granite work 4.20 mtr 170.00 714.00 2.33.2 19 providing and fixing superior quality (premium range) cp brass fittings complete as per direction of engineer in charge.swan neck pillar cock 15 mm nominal size 1.00 each 1298.00 1298.00 1.51.2 20 p & f grating of approved quality /make stainless steel sheet size 125 mm dia heavy quality of approved make 1.00 each 50.00 50.00 2.1.1 21 p & f gi pipes ( internal works ) with gi fittings excluding union (is:1239 mark) and ms clamps, including cutting and making good the wall and floors.15mm dia nominal boreb class 3.00 mtr 176.00 528.00 2.3.1 22 making connection of gi distribution branch with gi main including all fitting.upto 25mm dia 2.00 each 235.00 470.00 2.13.4 23 p & f 15 mm. dia connection pipe of approved quality/make :pvc pipe with c.p. brass nuts upto length, 600mm 1.00 each 105.00 105.00 2.8.4 24 p & f stop cock (is :8931 mark), superior quality & of approved make:c.p. brass 15mm nominal bore. 1.00 each 501.00 501.00 12.67.2 25 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :one or more coats on old work 37.45 sqm 61.00 2284.45 12.68.1 26 painting with enamel paint of approved brand and manufacture to give an even shade:two or more coats on new work 11.23 sqm 78.00 875.94 10.50.3 27 p & f plain fiber glass sheet ( frp sheet fiber reinforcement product sheet conforming to is: 12866 1989 having minimum thickness as below including fixing with nuts, bolts hooks and bitumen washer etc. complete:3.0 mm thick (wt. 5.0 kg/mtr.sq) 5.70 sqm 1435.00 8179.50 11.58.2 28 providing and fixing of precast concrete interlocking block of m 30 grade manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class a1/a2 as per bs 6717:2001 with rubber mould technology including painting with lacker polising. the cc interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint on is to be filled with fine sand. laying procedure on compacted subbase as defined. complete job is to be executed as per the instruction of engineer incharge. the rates to be inclusive of all lead, lifts and taxes general specification of blocks:1) shape as defined by engineer incharge 2) tensile splitting strength and braking load as per bs 6717:2001 3) color : grey cement natural colour.4) variation in dimension : less than 1.6 mm.5) variation in thickness : less than 3.2 mm.6) abrasion : as per bs : 6717:2001:: 80mm thick interlocking blocks ...

Maharana Pratap University Of Agriculture And Technology - Rajasthan

32103881 remaining miscellaneous work at mining department , ctae, udaipur surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish lead up to 50 mtr and lift up to 1.5 mtr : all kinds of soil 1050.00 sqm 4.46 4683.00 2 earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. all kinds of soil. 19.80 cum 164.00 3247.20 2.2.6 3 p & f gi pipes ( external works ) with gi fittings eccluding union (is:1239 mark) and ms clamps, including trenching and refilling earth etc.50mm dia nominal bore. b class 50.00 mtr 517.00 25850.00 2.32.6 4 supply & fixing g.i. union isi marked in g.i. pipe line as required complete in all respect of size :50mm dia nominal bore 2.00 each 211.00 422.00 1.6. 5 earth work in excavation over area ( exceeding 30 cm in depth. 1.5 mtr in width as well as 10 sqm on plan) including disposal of excavated earth lead up to 50 m and lift up to 1.5 mtr. disposal earth to be leveled and neatly dressed.all kinds of soil 90.59 cum 134.00 12139.06 (h 1) 1.3.1 6 supply & stacking good soil of earth at site complete including loading and unloading & transportation etc. good soil of earth 63.53 cum 250.00 15882.50 3.1.1 7 laying of lawns including ploughing leveling breaking of clods manuring and removal of stone etc. (cost of manuare or extra good earth to be paid separately ) maintenance of lawn foe 30 days or more till grass forms thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost : in rows 15 cm apart in either direction 400.19 sqm 30.00 12005.70 5.1.1(6) 8 carriage of following material including loading unloading and stacking if required complete in all respect. eaeth, sand, lime, moorum, manure or sludge, building rubbish, stone metal (girt and ballast etc), stone for masonry work & soling and excavated rock etc. for 2 km 90.59 cum 142.00 12863.78 1.30 9 filling available excavated earth (excluding rock) in trenches plinth side of foundation etc. in layers not exceeding 20 cm in depth consolidation each deposited layer by ramming and watering including lead up to 50 mtr and with all lift. 90.59 cum 78.00 7066.02 10 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm thick wall in : cement mortar 1:6 ( 1 cement : 6 sand ) 16.43 cum 2072.00 34042.96 11.44 11 random rubble dry stone kharanja under floor 18.55 cum 979.00 18160.45 12 structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete above plinth level upto 4.5 mtr height in flates, tees, angles & channals 1000.00 kg 81.00 81000.00 13 add extra of square rectangular hollow tubular section are used. 700.00 kg 9.00 6300.00 9.67 14 providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by engineer in charge) 0.50 mm (+ 0.05 %), total coated thickness with zinc coating 120 grams per sqm as per is: 277, in 240 mpa steel grade, 5 7 microns epoxy primer on both side of the sheet and polyester top coat 15 18 microns. sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by engineer in charge. the sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with epdm seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 80.00 sqm 599.00 47920.00 office of the estate officer maharana pratap university of agriculture & technology, udaipur (raj.) name of work : remaining miscellaneous work at mining department ,ctae, udaipur g schedule (rates are based on pwd bsr:2019, udaipur) item no. s.no. particulars qty. unit rate amount 3.2.7 15 providing and laying in position cement concrete including curing compaction etc . complete in specified grade excluding the cost of centering and shuttering. all work up to plinth level using crusher broken aggregate 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 17.64 cum 2896.00 51085.44 3.2.3 16 providing and laying in position cement concrete including curing compaction etc . complete in specified grade excluding the cost of centering and shuttering. all work up to plinth level using crusher broken aggregate : m15 grade nominal mix ( with graded stone aggregate 20mm nominal size) 1.45 cum 3802.00 5512.90 5.1.7 17 brick masonary in foundation and plinthwith bricks of class designation 75 in : cement mortar 1:6 ( 1 cement : 6 coarse sand ) 0.28 cum 3672.00 1028.16 11.3.4 18 cement concrete flooring grade 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete:75mm thick with 20mm thick nominal size aggregate 51.28 sqm 381.00 19537.68 14.9.2 19 dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead.in cement mortar 2.00 cum 370.00 740.00 14.54 20 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 mtr lead 3.72 cum 8.00 29.76 21 repair to cement plaster in cement mortar 1:6 (1 cement :6 fine sand) including removal of old plaster in regular shape and white or colour washing 50.00 sqm 168.00 8400.00 12.9.1 22 plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish : 25mm thick 56.52 sqm 162.00 9156.24 3.12.2 23 s & fcc 1:2:4 (m 15) precast kerb on dand upto 60 cm length over 20mm thick base of cement mortar 1:6 including jointing, earthwork, painiting and jointing with cement mortar 1:4 of size : ( 20 + 25) /2 x 40cm 58.00 mtr 459.00 26622.00 11.58.2 24 providing and fixing of precast concrete interlocking block of m 30 grade manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class a1/a2 as per bs 6717:2001 with rubber mould technology including painting with lacker polising. the cc interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint on is to be filled with fine sand. laying procedure on compacted sub base as defined. complete job is to be executed as per the instruction of engineer incharge. the rates to be inclusive of all lead, lifts and taxes general specification of blocks:1) shape as defined by engineer incharge 2) tensile splitting strength and braking load as per bs 6717:20013) color : grey cement natural colour.4) variation in dimension : less than 1.6 mm.5) variation in thickness : less than 3.2 mm.6) abrasion : as per bs : 6717:2001 : 80mm thick interlocking blocks 97.00 sqm 559.00 54223.00 3.19.3 25 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant : 110mm dia 3.00 mtr 196.00 588.00 10.17.3 26 providing stone slab covering over drains including filling of joints in cement sand mortar 1:3 with 35mm thick cement concrete flooring 1:2:4 mix complete with good finish with : stone slab 40 to 50 mm thick average 1.96 sqm 356.00 697.76 12.67.2 27 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :one or more coats on old work 1300.00 sqm 61.00 79300.00 12.67.1 28 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including prepration of base with primer putty lippy complete in all respect. 210.00 sqm 92.00 19320.00 12.68.2 29 painting with enamel paint of approved brand and manufacture to give an even shade:one or more coats on old work 400.00 sqm 57.00 22800.00 12.68.1 30 painting with enamel paint of approved brand and manufacture to give an even shade:two or more coats on new work ...

Urban Improvement Trust - Rajasthan

31814282 various civil works and maintenance works in sub division i of division ii b ( arc ) civil work clearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000m from road boundary. (morth specification : clause 201).by manual means : in area of light jungle 2 clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 silt clearance of drains, channels and canals with lift 1.5 mtr. and lead up to 50 mtr. 4 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 5 add extra over item no. 1.8 and 1.9 (sechedule item no 1) for every additional lift of 1.5 m or part thereof : 6 above 1.50 to 3.00m 7 m 35,60mm thick to be used in light traffic (light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 kn laden weight, or an wquivalent up to 0.5 million standerd axles (msa) for a design life of 20 years (a standerd axle is defind as a single axle load of 81.6 kn ) like pedestrain plazes, shopping complexes ramps, car parks, office drveways , housing colonies , office complexes , rural roads with low volume traffic ,fram houses, beach sites, tourist resorts, local authority footwys ,residential roads, etc. 8 category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 9 random rubble dry stone kharanja under floor. 10 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 11 m10 grade nominal mix, 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 13 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 14 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix 15 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 16 anti termite treatment of floor using imidacloprid 30.5% ec non repellent, odorless, low dose, environimentally safe terniticide with rapid action non corrosive stain free manufactured by bayer or equivalent company by drilling 12mm diameter holes 300mm apart injecting the emulsion as specified by the manufacturer and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area dpe 12mm dia termitube system with required number of junction boxes are to be installed. the termitube will run all along the perimeter wall both inside and outside. in the middle area the termitube to be installed at an interval of 1.00 mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. after successful testing of termitube, pesticide emulsion of imidacloprid 30.5% ec mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. the plinth area of the area treated will be measured for payment. 17 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 18 columns, pillars, posts and struts etc. 19 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in: 20 cement mortar 1:6 ( 1 cement : 6 sand). 21 cement mortar 1:4 ( 1 cement : 4 sand). 22 cement mortar 1:3 ( 1 cement : 3 sand). 23 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : 24 cement mortar 1:3 ( 1 cement : 3 sand). 25 cement mortar 1:4 ( 1 cement : 4 sand). 26 cement mortar 1:6 ( 1 cement : 6 sand). 27 pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 28 flush / ruled/ struck or weathered pointing. 29 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete and not applying 2 coats of hot bitumen complete as per specifications. 75mm thick 30 50mm thick 31 75 mm thick 32 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 33 suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 34 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 35 thermo mechanically treated bars (conforming of relevent is code) 36 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in : 37 cement mortar 1 : 4 (1 cement : 4 coarse sand) 38 cement mortar 1 : 6 (1 cement : 6 coarse sand) 39 half flyash brick masonry in foundation & plinth using flyash bricks of designation 75 40 cement mortar 1 : 4 (1 cement : 4 coarse sand) 41 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 42 12mm thick. 43 20mm thick. 44 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 45 making grooves as per design in plaster 10mm to 20mm wide. 46 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 47 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 48 two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 49 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 50 new work 51 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 52 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 53 two or more coats on new work 54 150cm high fencing with angle iron 50x50x6mm. placed at every 3mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with g.i. staples including earth work in excavation etc. complete. 55 grading roof for water proofing treatment withwater proffing compound 56 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 57 providing and fixing pressed steel door frames confirming to is 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applyinga coat of approved steel primer after pre treatment of the surface including filling with cc 1:2:4(m15 grade) complete as directed by engineer in charge : 58 profile b 59 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 30 mm thick . 60 decorative teak veneer both side 61 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). : for fixed portion 62 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 63 providing and fixing of plastic shutter infill made from extruded multi chamber hollow p.v.c. section having cross section of 200 x 20 x 1 mm and shutter frame made from extrude p.v.c. section in the configuration of double walled c section having an overall cross section of 40 x 37 mm and door fittings such as hinges, aldrop, handles, stopper, locking bolt will be provided. 64 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 65 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 66 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 67 providing and fixing superior quality like hardvyn or equivalent hydraulic door closure. 68 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 69 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 70 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : 71 good quality south black above 3601 cm2 slabs 72 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 73 granite work (full edge moulding ) 74 p & f 1st quality heavy duty vitrified glazed mat tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. 75 size600 mm x 1200mm 76 providing & fixingbrown kota/ mandana / dholpur/ slate stone incladding / flooring structuralbase with white cement & tinex chemical& ss clamp and fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attachedcomplete in all respect as per direction of engineer in charge & architect with all lead & lift. the stone measurement will be done of outer most dimension. thickness of stone 25 30mm. 77 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 78 25 mm thick slab. 79 s/f of fire bricks on edg flooring with fire bricks suitable for 1300 degree centigrade safe working temperature as per is :8 specification laid on & filling of joint by fire resistant mortar/adhesive of required thickness as per directed on a bed of 20 mm thick 1:2 cement mortar of bricks 9 x 4.5x 3 (rate approved year 2008) 80 providing and fixing of glass moisac tiles ( bisseze marke ) size 20 x 20 x 4 mm applied with aaproved adhesive as per specification and direction of engineer in charge 81 providing and fixing staincase railing 90 cm high from nosing of made offollowing specifications. 82 50 mm outer dia (2 mm thick) s.s. pipe hand rail. 83 40 mm outer dia (2 mm thick) s.s. pipe baluster @ 1.00 mtr. 84 4 nos. 20 mm fs. s pipe intermediate runners parallel to hand. 85 s.s. shoe 1.60 mm thick 75 mm outer dia. at each baluster 86 baluster to be welded with s.s. plate 50 mm dia (3 mm thick) anchored in c.c. block with suitable dash fastners 87 50 mm dia & 2 mm thick s.s. pipe for start and end vertical ornamental posts to be provided as per direction of engineer in charge 88 the stainless steel work shall be brushed steel finish with all joints/welds properly grinded to final finish. the stainless steel shall be 304 grade and shall confirm to relevant i.s. 89 providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.extra if square,rectangular hollow tubularsections are used or grill made by flats only 90 decorative plaster work with spectrum textured coating as per approved colour and shade complete as per manufactures specifications. 91 grit textured @ 2.5 to 3.0 mm thick. 92 ornamental cement plaster in cement sand mortar1 : 4 making kangooras etc. as per jaipurpractice. 93 supplying and fixing machine cutdressed 75 mm pinksand stone (bansi paharpur) dasa/ coping wth ornamental shape having moulding and pan shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 94 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 95 0.63 mm thick with zinc coating not less than 275 gm/m2 96 supply & spreading ofgood earth at site complete including loading unloading & transportation etc. 97 supply of dry manure including loading unloading,transportation & stacking at site. 98 farm yard manure(organic) 99 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 100 laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc.(cost of manure or extra good earth to be paid seperately) maintenance of lawns for 30 daysor more till the grass forms a thick lawns free from weeds & fit fo 101 in rows 7.5 cms. apart in either direction 102 construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8 10 tonne to meet requirement of table 300 2 including cost of compensation for earth taken from private land with lead upto 1 km as per morth specification : clause no. 305. 103 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 104 p & f european type white glazed vitreous china 1st quality double syphonic w.c (is :2556 mark) with p or s trap including cutting and making good the wall and floor 105 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor: 106 size 580x440mm. 107 p & f low level flushing cistern of 10 ltr. capacity (is : 2556 mark) o9f approved make with colplete fitting ,c.i. brackets duly painted , brass ball cock with ball, (is :1703 mark)complete including cutting and making good the wall. 108 wvc with c.p. brass bend. 109 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) &32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall.: 110 size 550 mm x 400 mm dia for counter top 111 1.0 mm thick salem stainless steel aisi 304 & is 13983 1994kitchen sink of approved make (nirali, neel – kanth, jaina, faber castell )with large waste coupling. 112 (24 x 18 x 8) (20x16x8) 113 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. 114 c.p. inlet connection 15mm.brass (is : 8931 marked) with 37 cm long pipe and nut. 115 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 116 1000 litres capacity. 117 providing and fixingsuperior quality (jaguar contiental ) cp brassfittings complete as per direction of ei 118 bib cock with long thread 15 mm nominal size 119 brass / gunmetalhalf turnwt. 1 kg.ofapprovedquality / make,25mmnominalbore. 120 p & f full way valve (is:778 mark) or wheel valve of approved make 121 gun metal 32mm nominal bore. 122 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 123 20mm nominal outer dia pipes 124 32mm nominal outer dia pipes 125 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 126 110 mm dia 127 160 mm dia 128 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: 129 coupler (socket) 130 110mm dia 131 160 mm dia 132 plain tee 133 110mm dia 134 160mm dia 135 door tee 136 110mm dia 137 bend 45 138 110mm dia 139 vent cowel 140 110mm dia 141 door bend (left & right) 142 110mm dia 143 pipe clip 144 110mm dia 145 plain floor trap 146 110mm dia 147 p trap 148 110mm dia 149 socket plug 150 110mm dia 151 door cap 152 110mm dia 153 construction of chamber in all type of soil with 300 mm thick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 154 do size 450 x 450mm depth upto0.5 m cement cover with frame 155 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,hot dipped galvanized modular box with earth terminal, 6 a modular switch,modular plate with grid plate,screws,making connections, testing etc. as required. 156 short point (up to 3 mtr.) 157 medium point (up to 6 mtr.) 158 long point(up to 10 mtr..) 159 wiring of twin control light point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper earth conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 160 medium point (up to 6 mtr) 161 wiring of 3 pin 6 amp light plug point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp switch & 6 amp socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 162 on board 163 medium point (up to 6 mtr) 164 long point (up to 10 mtr) 165 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. 166 25 mm 167 32 mm 168 50 mm 169 supplying and fixing of power plug point modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. switch and socket outlet, making connection , testing , etc. as required. 170 p&f metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without mcb) including making connections, testing etc.as required 171 single / double pole(three pin) 172 32 a 173 providing & fixing isi marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. 174 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 175 2 x 2.5 sq. mm. + 1x1.5sqmm 176 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 177 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 178 single pole mcb 179 6 a to 32 a rating 180 four pole mcb 181 40 a 63 a rating 182 four pole mcb 183 6 a to 32 a rating 184 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required. 185 double door (single phase) 186 12 way 187 double door (three phase) 188 8 way 189 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 190 25.0 sq.mm 191 4 core 192 50.0 sq.mm 193 120.0 sq,mm 194 3.5 core 195 150.0 sq,mm 196 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 197 3.5 x 120.0 sq.mm 198 4 x 25.0 sq.mm 199 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 200 10.0 sq.mm 201 4 core 202 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty copper lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 203 4 x 10.0 sq.mm 204 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of crca sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadethe panel having pu/ neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate m.s. base channel ,hinged door with locking arrangement for equipment/switchgear. thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. load bearing structure shall beof 2.0 mmthick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from cpri approved fabricator) 205 supplying and fixing of aluminium / copper bus barby means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. 206 electrolytic grade aluminium bus bar 207 sf of (0 500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 208 analog type ( 96mm x 96mm ) 209 sf of ct operated direct reading typeampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 210 analog type ( 96mm x 96mm ) 211 below 500 a 212 sf ofcurrent transformer, with all necessary support in existing panel including connection etc. as required . 213 up to 150/5 ratio, 10 va, class 1 accuracy 214 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc.as required . 215 sf of ct linked selector switch of 10 aforampere meter (4 position ) including making connection etc.as required . 216 sf of110/220 v, led (22.5 mm dia ) indicatinglamp with integral circuit, terminal block, including connection etc. as required. 217 red/yellow/green colour 218 supplying and drawing fr pvc insulated & unsheathed flexiable copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 219 1 x 1.5 sq.mm 220 1 x 2.5 sq.mm 221 1 x 4.0 sq.mm 222 1 x 6.0 sq.mm 223 sitc of self healing mpp/mp type shunt capacitor (banks) conforming to is:13340 41 / iec :831 1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.5 watt per kvar . including making connections with suitable capacity conductors/cables testing etc. as required. 224 heavy duty three phase 440 v , 50 hz capacitor (bank) 225 sitc of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar,metering facility as required. 226 6 to 8 stage 227 sensitivity upto 50 milli amp 228 p & f ofcam operated rotary switchs on existing panel with 2 way and off postion 229 one pole 230 16 amp 231 p & f of440 volt 3 pole capacitor(ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to is:13947 4 1/iec:947 4 1, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 232 up to 6 kvar 233 7 to 10 kvar 234 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 235 triple pole mcb 236 6 a to 32 a rating 237 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating: 238 open execution type 239 200 amp 240 sitc of quick make and quick break4 polecurrent limiting mccb having following current rating, short circuitbreaking capacityat 440/415 v, 50 hz; o/l & s/c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 241 with thermal magnetic release 242 up to 160 amp , 25 ka, adjustable o/l & fixed s/c setting, ics = 100 % icu 243 plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 244 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 245 8 swg copper wire 246 providing & fixing of heavy duty capacitor start 900/1400 rpm single phase isi marked exhaust fan is:2312 marked in existing opening making connections, testing etc. as required 247 300 mm sweep (900/1400 rpm) 248 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 249 1400 mm sweep 250 p & f of ip 20 led tube light 20 watt with external batten made from crca sheet steel suitable to replace t 8/t 12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 lm/ watt minimum expected life time of 25000 burning hours, cct 5700 k ansi, cri 80, driver efficiency >85%, life expectancy of driver rnin 30000 hrs. pf 0,95 at full load/ 230 volt ac. 251 p & laying xlpe insulated is:7098/ii/85 of group1 and approved make h.t.cable for working voltage 11 k.v.earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 252 3 core 185.0 sq.mm ...

Urban Improvement Trust - Rajasthan

31814018 various civil works and maintenance works in sub division ii of division ii b ( arc ) civil works clearing and grubbing road land including uprooting rank vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm, removal of stumps, disposal of unserviceable material and stacking of serviceable material upto 1000m from road boundary. (morth specification : clause 201).by manual means : in area of light jungle 2 clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared. 3 silt clearance of drains, channels and canals with lift 1.5 mtr. and lead up to 50 mtr. 4 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 5 add extra over item no. 1.8 and 1.9 (sechedule item no 1) for every additional lift of 1.5 m or part thereof : 6 above 1.50 to 3.00m 7 m 35,60mm thick to be used in light traffic (light traffic is defined as a daily traffic up to 150 commercial vehicles exceeding 30 kn laden weight, or an wquivalent up to 0.5 million standerd axles (msa) for a design life of 20 years (a standerd axle is defind as a single axle load of 81.6 kn ) like pedestrain plazes, shopping complexes ramps, car parks, office drveways , housing colonies , office complexes , rural roads with low volume traffic ,fram houses, beach sites, tourist resorts, local authority footwys ,residential roads, etc. 8 category bdenated only two side like i,z,t shape etc. as per irc sp 63:2004 9 random rubble dry stone kharanja under floor. 10 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 11 m10 grade nominal mix, 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix 13 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 14 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix 15 centering and shuttering with plywood or steel plate including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 16 anti termite treatment of floor using imidacloprid 30.5% ec non repellent, odorless, low dose, environimentally safe terniticide with rapid action non corrosive stain free manufactured by bayer or equivalent company by drilling 12mm diameter holes 300mm apart injecting the emulsion as specified by the manufacturer and plugging with cement mortar 1:2 ( 1 cement : 2 coarse sand) in the whole floor area dpe 12mm dia termitube system with required number of junction boxes are to be installed. the termitube will run all along the perimeter wall both inside and outside. in the middle area the termitube to be installed at an interval of 1.00 mtr. or less both ways as required with sufficient number of junction boxes to pump the emulsion. after successful testing of termitube, pesticide emulsion of imidacloprid 30.5% ec mixed with water in the ration of 1:474 will be pumped by a motorized spray pump from the junction box in specified manner. the plinth area of the area treated will be measured for payment. 17 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 18 columns, pillars, posts and struts etc. 19 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in: 20 cement mortar 1:6 ( 1 cement : 6 sand). 21 cement mortar 1:4 ( 1 cement : 4 sand). 22 cement mortar 1:3 ( 1 cement : 3 sand). 23 random rubble stone masonry with hard stone in superstructure aboveplinth level and upto three levelabove 30cm. thick walls in : 24 cement mortar 1:3 ( 1 cement : 3 sand). 25 cement mortar 1:4 ( 1 cement : 4 sand). 26 cement mortar 1:6 ( 1 cement : 6 sand). 27 pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) : 28 flush / ruled/ struck or weathered pointing. 29 providing and laying damp proof course with cement concrete grade m 150 (1 : 2 : 4) mortar prepared with 1% solution of water proof compound complete and not applying 2 coats of hot bitumen complete as per specifications. 75mm thick 30 50mm thick 31 75 mm thick 32 centering & shuttering with plywood or steel plate including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor three level for : 33 suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 34 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 35 thermo mechanically treated bars (conforming of relevent is code) 36 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in : 37 cement mortar 1 : 4 (1 cement : 4 coarse sand) 38 cement mortar 1 : 6 (1 cement : 6 coarse sand) 39 half flyash brick masonry in foundation & plinth using flyash bricks of designation 75 40 cement mortar 1 : 4 (1 cement : 4 coarse sand) 41 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 42 12mm thick. 43 20mm thick. 44 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3 fine sand) 45 making grooves as per design in plaster 10mm to 20mm wide. 46 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 47 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : 48 two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 49 painting exterior surface ofwallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect. 50 new work 51 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 52 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 53 two or more coats on new work 54 150cm high fencing with angle iron 50x50x6mm. placed at every 3mtr. apart 30cm. in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with 50x50x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with g.i. staples including earth work in excavation etc. complete. 55 grading roof for water proofing treatment withwater proffing compound 56 cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 57 providing and fixing pressed steel door frames confirming to is 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applyinga coat of approved steel primer after pre treatment of the surface including filling with cc 1:2:4(m15 grade) complete as directed by engineer in charge : 58 profile b 59 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a: 30 mm thick . 60 decorative teak veneer both side 61 providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is :733 and is :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required pvc/neoprene felt etc. aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing /paneling , c.p. brass/ stainless steel screws al. tower bolt & al. handle & al. aldrop etc.,all complete as per architectural drawings and thedirections of engineer in – charge .(glazing and paneling to be paid for separately). : for fixed portion 62 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 63 providing and fixing of plastic shutter infill made from extruded multi chamber hollow p.v.c. section having cross section of 200 x 20 x 1 mm and shutter frame made from extrude p.v.c. section in the configuration of double walled c section having an overall cross section of 40 x 37 mm and door fittings such as hinges, aldrop, handles, stopper, locking bolt will be provided. 64 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 65 for shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). 66 polyester powder coating aluminum( minimum thickness of powder coating 50 micron) 67 providing and fixing superior quality like hardvyn or equivalent hydraulic door closure. 68 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 300mm x 450mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 69 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirmingto is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 70 providing and fixing 15 to 20 mm thick granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm (av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : 71 good quality south black above 3601 cm2 slabs 72 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 73 granite work (full edge moulding ) 74 p & f 1st quality heavy duty vitrified glazed mat tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1: 4 including grounting the joints with white cement and matching pigment etc complete. 75 size600 mm x 1200mm 76 providing & fixingbrown kota/ mandana / dholpur/ slate stone incladding / flooring structuralbase with white cement & tinex chemical& ss clamp and fasteners (of approved brand) laid and jointed with white cement slurry mixed with pigment to match the shade of the slab as per drawing attachedcomplete in all respect as per direction of engineer in charge & architect with all lead & lift. the stone measurement will be done of outer most dimension. thickness of stone 25 30mm. 77 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 78 25 mm thick slab. 79 s/f of fire bricks on edg flooring with fire bricks suitable for 1300 degree centigrade safe working temperature as per is :8 specification laid on & filling of joint by fire resistant mortar/adhesive of required thickness as per directed on a bed of 20 mm thick 1:2 cement mortar of bricks 9 x 4.5x 3 (rate approved year 2008) 80 providing and fixing of glass moisac tiles ( bisseze marke ) size 20 x 20 x 4 mm applied with aaproved adhesive as per specification and direction of engineer in charge 81 providing and fixing staincase railing 90 cm high from nosing of made offollowing specifications. 82 50 mm outer dia (2 mm thick) s.s. pipe hand rail. 83 40 mm outer dia (2 mm thick) s.s. pipe baluster @ 1.00 mtr. 84 4 nos. 20 mm fs. s pipe intermediate runners parallel to hand. 85 s.s. shoe 1.60 mm thick 75 mm outer dia. at each baluster 86 baluster to be welded with s.s. plate 50 mm dia (3 mm thick) anchored in c.c. block with suitable dash fastners 87 50 mm dia & 2 mm thick s.s. pipe for start and end vertical ornamental posts to be provided as per direction of engineer in charge 88 the stainless steel work shall be brushed steel finish with all joints/welds properly grinded to final finish. the stainless steel shall be 304 grade and shall confirm to relevant i.s. 89 providing and fixing steel gate grating and grills made of angles, tees, square bars or other flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide.extra if square,rectangular hollow tubularsections are used or grill made by flats only 90 decorative plaster work with spectrum textured coating as per approved colour and shade complete as per manufactures specifications. 91 grit textured @ 2.5 to 3.0 mm thick. 92 ornamental cement plaster in cement sand mortar1 : 4 making kangooras etc. as per jaipurpractice. 93 supplying and fixing machine cutdressed 75 mm pinksand stone (bansi paharpur) dasa/ coping wth ornamental shape having moulding and pan shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 94 providing corrugated g.s. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 95 0.63 mm thick with zinc coating not less than 275 gm/m2 96 supply & spreading ofgood earth at site complete including loading unloading & transportation etc. 97 supply of dry manure including loading unloading,transportation & stacking at site. 98 farm yard manure(organic) 99 spreading of manure and good earth in required thickness (cost of manure and good earth to be paid separately). 100 laying of lawns including ploughing levelling breaking of clods manuring & removal of stones etc.(cost of manure or extra good earth to be paid seperately) maintenance of lawns for 30 daysor more till the grass forms a thick lawns free from weeds & fit fo 101 in rows 7.5 cms. apart in either direction 102 construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8 10 tonne to meet requirement of table 300 2 including cost of compensation for earth taken from private land with lead upto 1 km as per morth specification : clause no. 305. 103 rough chisel dressed stone flooring over 20 mm (av.) thick base in cm 1 : 6 including pointing with cement mortar 1 : 2 (1 cement : 2 stone dust) with and admixture of pigment to match the shade of stone with joint thickness upto 15 mm : 35 mm thick red sand stone. 104 p & f european type white glazed vitreous china 1st quality double syphonic w.c (is :2556 mark) with p or s trap including cutting and making good the wall and floor 105 p & f indian type white glazed vitreous china 1st quality w.c. orissa pan (is :2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor: 106 size 580x440mm. 107 p & f low level flushing cistern of 10 ltr. capacity (is : 2556 mark) o9f approved make with colplete fitting ,c.i. brackets duly painted , brass ball cock with ball, (is :1703 mark)complete including cutting and making good the wall. 108 wvc with c.p. brass bend. 109 p & f wvc wash basin (1st quality, i.s. : 2556 mark) of approved make with c.i. brackets duly painted, 1 no. 15 mm c.p. pillar cock (is : 8934 mark) &32 mm c.p. brass waste coupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall.: 110 size 550 mm x 400 mm dia for counter top 111 1.0 mm thick salem stainless steel aisi 304 & is 13983 1994kitchen sink of approved make (nirali, neel – kanth, jaina, faber castell )with large waste coupling. 112 (24 x 18 x 8) (20x16x8) 113 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc. 114 c.p. inlet connection 15mm.brass (is : 8931 marked) with 37 cm long pipe and nut. 115 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 116 1000 litres capacity. 117 providing and fixingsuperior quality (jaguar contiental ) cp brassfittings complete as per direction of ei 118 bib cock with long thread 15 mm nominal size 119 brass / gunmetalhalf turnwt. 1 kg.ofapprovedquality / make,25mmnominalbore. 120 p & f full way valve (is:778 mark) or wheel valve of approved make 121 gun metal 32mm nominal bore. 122 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,) 123 20mm nominal outer dia pipes 124 32mm nominal outer dia pipes 125 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 126 110 mm dia 127 160 mm dia 128 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: 129 coupler (socket) 130 110mm dia 131 160 mm dia 132 plain tee 133 110mm dia 134 160mm dia 135 door tee 136 110mm dia 137 bend 45 138 110mm dia 139 vent cowel 140 110mm dia 141 door bend (left & right) 142 110mm dia 143 pipe clip 144 110mm dia 145 plain floor trap 146 110mm dia 147 p trap 148 110mm dia 149 socket plug 150 110mm dia 151 door cap 152 110mm dia 153 construction of chamber in all type of soil with 300 mm thick masonry in cm 1:6 m 10 cm thick c.c. 1:5:10 in foundation, 20mm thick insider plaster in cm 1:6, finished with floating neat cement, 50mm thick m 15 grade c.c. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 154 do size 450 x 450mm depth upto0.5 m cement cover with frame 155 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,hot dipped galvanized modular box with earth terminal, 6 a modular switch,modular plate with grid plate,screws,making connections, testing etc. as required. 156 short point (up to 3 mtr.) 157 medium point (up to 6 mtr.) 158 long point(up to 10 mtr..) 159 wiring of twin control light point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper earth conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp two way switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 160 medium point (up to 6 mtr) 161 wiring of 3 pin 6 amp light plug point with 1.5 sq.mm fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade and 1.5 sq.mm.fr pvc insulated unsheathed flexiable copper conductor 1.1 kv grade(is: 694) of approved make in surface/ recessd isi marked medium duty pvc conduit & its accessories, round tiles, 18 swg m.s. box with earthing terminal, 6 amp switch & 6 amp socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 162 on board 163 medium point (up to 6 mtr) 164 long point (up to 10 mtr) 165 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required. 166 25 mm 167 32 mm 168 50 mm 169 supplying and fixing of power plug point modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. switch and socket outlet, making connection , testing , etc. as required. 170 p&f metal clad industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in sheet steel enclosure (without mcb) including making connections, testing etc.as required 171 single / double pole(three pin) 172 32 a 173 providing & fixing isi marked 6 amp bakelite batten/angle holder including making connection testing etc. as required. 174 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required. 175 2 x 2.5 sq. mm. + 1x1.5sqmm 176 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 177 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 178 single pole mcb 179 6 a to 32 a rating 180 four pole mcb 181 40 a 63 a rating 182 four pole mcb 183 6 a to 32 a rating 184 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required. 185 double door (single phase) 186 12 way 187 double door (three phase) 188 8 way 189 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 190 25.0 sq.mm 191 4 core 192 50.0 sq.mm 193 120.0 sq,mm 194 3.5 core 195 150.0 sq,mm 196 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 197 3.5 x 120.0 sq.mm 198 4 x 25.0 sq.mm 199 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with copper conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size. 200 10.0 sq.mm 201 4 core 202 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty copper lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 203 4 x 10.0 sq.mm 204 sitc of wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel made out of crca sheet , required hardware,duly treated for derusting in 7 tank process with dephosphating and with powder coating on both side of panel in desired shadethe panel having pu/ neoprene rubber gasket of not less than 3mm thickness , separate detachable gland plate m.s. base channel ,hinged door with locking arrangement for equipment/switchgear. thickness of sheet shallnot be less than 1.6 mm up to 600 mm length / widthof any compartment and be of 2.0 mm above 600 mm. load bearing structure shall beof 2.0 mmthick sheet supported by base m.s. channel if required . side walls and cable alley compartments having bolted type doors with / withoutdetachable extension type structure. (only outer area on all sides shall be measured & panel to be fabricated from cpri approved fabricator) 205 supplying and fixing of aluminium / copper bus barby means of smc / dmc type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable pvc sleeves. 206 electrolytic grade aluminium bus bar 207 sf of (0 500) v range volt meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 208 analog type ( 96mm x 96mm ) 209 sf of ct operated direct reading typeampere meter on existing panel , making connection by pvc insulated copper conductor with pvc sleeves / channel etc. as required. 210 analog type ( 96mm x 96mm ) 211 below 500 a 212 sf ofcurrent transformer, with all necessary support in existing panel including connection etc. as required . 213 up to 150/5 ratio, 10 va, class 1 accuracy 214 sf of selector switch of 10 a for voltmeter (4 position ) including making connection etc.as required . 215 sf of ct linked selector switch of 10 aforampere meter (4 position ) including making connection etc.as required . 216 sf of110/220 v, led (22.5 mm dia ) indicatinglamp with integral circuit, terminal block, including connection etc. as required. 217 red/yellow/green colour 218 supplying and drawing fr pvc insulated & unsheathed flexiable copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 219 1 x 1.5 sq.mm 220 1 x 2.5 sq.mm 221 1 x 4.0 sq.mm 222 1 x 6.0 sq.mm 223 sitc of self healing mpp/mp type shunt capacitor (banks) conforming to is:13340 41 / iec :831 1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( psd ) and shall have dissipation factor less than 0.0025 at 50 hz and total wattage loss less than 0.5 watt per kvar . including making connections with suitable capacity conductors/cables testing etc. as required. 224 heavy duty three phase 440 v , 50 hz capacitor (bank) 225 sitc of microprocessor based three phase sensingpower factor correction relay having following sensing capacitysecondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like kw, kva, kvar,metering facility as required. 226 6 to 8 stage 227 sensitivity upto 50 milli amp 228 p & f ofcam operated rotary switchs on existing panel with 2 way and off postion 229 one pole 230 16 amp 231 p & f of440 volt 3 pole capacitor(ac 6 b ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current, conforming to is:13947 4 1/iec:947 4 1, din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank. 232 up to 6 kvar 233 7 to 10 kvar 234 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required. 235 triple pole mcb 236 6 a to 32 a rating 237 p&f on load change over switch, front handle operated, four pole 415 v conforming to is:13947 p iii including connections , testing etc. as required in the following rating: 238 open execution type 239 200 amp 240 sitc of quick make and quick break4 polecurrent limiting mccb having following current rating, short circuitbreaking capacityat 440/415 v, 50 hz; o/l & s/c settings and conforming to is 60947 2 / iec 60947 2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for uvr , shunt trip ,earth fault trip, push( test) to trip , including making connections with lugs & spreaders,etc. as required. 241 with thermal magnetic release 242 up to 160 amp , 25 ka, adjustable o/l & fixed s/c setting, ics = 100 % icu 243 plate earthing as per is:3043 withcopper earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 244 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 245 8 swg copper wire 246 providing & fixing of heavy duty capacitor start 900/1400 rpm single phase isi marked exhaust fan is:2312 marked in existing opening making connections, testing etc. as required 247 300 mm sweep (900/1400 rpm) 248 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 249 1400 mm sweep 250 p & f of ip 20 led tube light 20 watt with external batten made from crca sheet steel suitable to replace t 8/t 12 tube light, integral driver, 2000 luman + 5% tolerarrce system luman efficiacy of 100 lm/ watt minimum expected life time of 25000 burning hours, cct 5700 k ansi, cri 80, driver efficiency >85%, life expectancy of driver rnin 30000 hrs. pf 0,95 at full load/ 230 volt ac. 251 p & laying xlpe insulated is:7098/ii/85 of group1 and approved make h.t.cable for working voltage 11 k.v.earthed direct in ground including excavation of 30cmx100cm size trench, 25cmlayer of river sand, iind class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 252 3 core 185.0 sq.mm ...

Department Of Local Bodies - Rajasthan

31810325 civil work for auditorium for nagar parishad, dausa, rajasthan civil work for auditorium for nagar parishad, dausa, rajasthan earth workclearing grass and removal of rubbish (maximum 150mm) by manual means and disposal at a lead of 50 metres as per mort&h specification clause 201. 2 earth work in excavation in open area, stp, wtp, pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of engineer. (measurements for payment to be done as per standard drawings). in all type of soil. upto 3.0 m depth. 3 earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of engineer for following depths, below natural ground / road top level. in all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. depth upto 1.5 m. 4 add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.1.1 5 in ordinary rock. depth upto 1.5 m. 6 add extra for over all depth of excavation above 1.5 m and upto 3.0 m over item no 4.10.2.1 7 carriage of materials by mechanical transport including loading, unloading and stacking ::upto 1 km 8 stone, boulders, gravelly materia 9 earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceeding 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. 10 diluting and injection chloropyrifos emulsifiable concentrate 20% with 1% concentration for pre constructional anti termite treatment as per is 6313 part iii as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 11 providing and laying of filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of mort&h specifications with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specification including all material, labour, machinery as per clause 710.1.4 of irc:78 and clause 2200 of mort&h specification. 12 concrete work 13 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 14 making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. 15 reinforced cement concrete 16 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement all work upto plinth level 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (as per design mix). 17 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement :1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (as per design mix) 18 reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: m 30 grade concrete. 19 reinforced cement concrete work in arches, arch ribs, domes, vaults, shells, folded plate and roofs having slope more than 15° upto two stories excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 20 providing and laying upto two stories reinforced cement concrete in kerbs, steps and the like excluding the cost of centring, shuttering, finishing and reinforcement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). 21 add extra for laying reinforced cement concrete above two stories (or 7.50 mtr height above plinth level) for every one storey or 3.00 m height or part thereof. 22 centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete. 23 walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 24 suspended floors, roofs, landings, balconies and access platform. 25 lintels, beams, plinth beams, girders, bressumers and cantilevers. 26 columns, pillars, piers, abutments, posts and struts.22.1.5 27 stairs, (excluding landings) except spiral staircases. 28 extra for shuttering in circular work (20% of respective centring and shuttering items). 29 edges of slabs and breaks in floors and walls. under 20 cm wide. 30 weather shade, chajjas, corbels etc., including edges. 31 add extra for doing centering and shutteriing work for every additional height of 1 metre or part thereof beyond initial 7.5 metre height from plinth level. 32 reinforcement for r.c.c. work at all levels including straightening, cutting, bending, placing in position and binding all complete. thermo mechanically treated bars. 33 brick / stone masonery work 34 brick work with fps bricks of class designation 75 in foundation and plinth in cement mortar 1:4 (1 cement : 4 coarse sand). 35 brick work with fps bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in cement mortar 1:4 (1 cement : 4 coarse sand). 36 half brick masonry with fps bricks of class designation 75 in superstructure above plinth level upto two stories. cement mortar 1:3 (1 cement :3 coarse sand). 37 extra for providing and placing in position 2 nos. 6mm dia. m.s. bars at every third course of half brick masonry. 38 random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of mort&h specification including all scaffolding material, labour, machinery but excluding pointing and plastering. in cement mortar 1:4 (1 cement : 4 coarse sand). 39 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12mm (av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. green / black above 3601 cm2 slabs. 40 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. granite/kota stone work. moulding. 41 extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 42 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirming to is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 43 extra for using marble printed / granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and mat finished tiles 44 providing and fixing motive pieces all coloures for glazed tiles laid over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white mixed with pigment of matching shade complete. size 200 x 300mm. 45 p & f 1st quality vitrified porcelain polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm x 600 mm. 46 providing and fixing 1st quality mat & glossy finished ceramic tiles colour such as standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to is : 13753 & is : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the the cost of cement mortar bed 1:4) size 300mm x 450mm. 47 providing and fixing 1st quality ceramic glazed vitrified tiles of colour standard white, grey, ivory, fume, red brown, light green, light blue, and other light shades with water absorbtion less than or equal to 0.08% confirming to is : 13753 & is : 15622 in floor, steps etc laid on bed on neat cement slury finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete. (excluding the the cost of cement plaster on wall and pillar). size 600mm x 1200mm 48 38mm thick wood block flooring of first class teak wood laid over 25mm thick levelling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 10mm nominal size) to be paid separately coated with a thin layer of hot bitumen (blown type) @ 2.45 kg per sqm. including fixing blocks in position after dipping in hot bitumen (blown type) upto half depth, planed, levelled smooth and finished complete. 49 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 50 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. red sand stone. 51 extra for pre finished nosing in treads of steps of kota stone/ sand stone slab. 52 roofing 53 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75x75mm deep chase. 54 providing corrugated g.s. sheet roofing including vertical/ curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80mm thick with zinc coating not less than 275gm/m². 55 extra for circular cutting in c.g.s. sheet roofing for making opening of area exceeding 40 square decimetre 0.80 mm thick 56 providing and fixing 15 cm wide 45 cm over all semi circular plain g.s. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc. including making necessary connections with rain water pipes complete. 0.80mm thick with zinc coating not less than 275gm/m² 57 cement plastering including t&p, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement : 4 fine/ coarse sand) 58 cement plastering including t&p, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix : 1:4 (1 cement : 4 fine/ coarse sand). 59 cement plastering including t&p, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of r.c.c. slabs and beams. 60 extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 61 18 mm thick moulded cement mortar band in two coats under layer 12mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) toplayer 6mm thick with cement mortar 1:4 (1 cement : 4 fine sand). design on outer plaster. 62 extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 63 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: two or more coats on new work. 64 finishing walls with acrylic smooth exterior paint of required shade new work (two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 65 painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work. 66 providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 67 providing and fixing thermal insulation with resin bonded fibre glass wool conforming to is : 8193, density 16kg/m3 , 50mm thick, wrapped in 200g virgin polythene bags placed over existing false ceiling and held in position by criss crossing gi wire. 68 providing and fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving screws, over expansion joints on vertical surfaces/ceilings with full threaded, cadmium plated steel screws 4mm dia. stem, 30mm long and aluminium washers 2mm thick, 15mm dia. at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete. powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating 50 micron). 69 filling the gap in between aluminium frame & adjacent rcc/ brick/ stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of engineer in charge complete. upto 5mm depth and 5 mm width. 70 providing and laying expansion joint complete as per drawing and technical specification and as per clause 2605 of mort&h specification including all material, labour, machinary etc. 71 fillar joint with 20m thick compressible fibre board. 72 fillar joint with joint sealing compound with coarse sand and 6 %bitumen by weight. 73 structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: hot finished seamless type tubes. 74 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or with dash fastener or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 75 providing and fixing pressed steel door frames confirming to is: 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by engineer in charge: profile c 76 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing and staircase railing including applying a priming coat of approved steel primer. m.s. tube. 77 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of t iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 78 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesin in glue both sides including approved isi marked stainless steel butt hinges fittings with necessary screws complete as per annexure a : 30 mm thick decorative teak veneer both side. 79 extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (over all area of door shutter to be measured). decorative teak veneer both side. 80 extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) rectangular or square. 81 extra for cutting rebate in flush door shutters for making double leaf shutter(total area ofthe shutter to be measured). 82 providing and fixing expandable fasteners of specified size with necessary plastic sleeves and galvanised m.s. screws including drilling holes in masonry work /cc/ r.c.c. and making good etc. complete. 50 mm long. 83 providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with c.p. brass screws and wooden plugs, etc., wherever necessary complete: 20 mm dia. 84 providing and fixing to existing door frames. 30mm thick factory made solid both side pre laminated panel pvc door shutter consisting of frame made out of m.s. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. m.s. frame shall have a coat of steel primers of approved make and manufacture. m.s. frame covered with 5mm thick heat moulded pre laminated pvc c channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide pvc sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide pvc sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross pvc sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side pre laminated pvc sheet to be fitted in the m.s. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide pvc sheet beading on inner side, and joined together with solvent cement adhesive. an additional 5mm thick pvc strip of 20mm width is to be stuck on the interior side of the c channel using pvc solvent adhesive etc. complete as per direction of engineer in charge. manufacturer’s specification & drawing (for w.c. and bathroom door shutter). 85 aluminium work 86 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required pvc/neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / panelling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. (glazing and panelling to be paid for separately) : for fixed portion. anodised aluminium (anodised transparent or dyed to required shade according to is: 1868, minimum anodic coating of grade ac 15). 87 for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of pvc / neoprene gasket required (fittings shall be paid for separately). powder coated aluminium (minimum thickness of powder coating 50 micron). 88 providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood pre laminated one side decorative lamination on other side balancing lamination grade i, type ii, is : 12823 marked including priming coat on unexposed surface, with necessary fixing arrangement and screws etc. complete : 25 mm thick 89 providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with pvc/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer incharge . (cost of aluminium snap beading shall be paid in basicitem) : with float glass panes of 5.50 mm thickness. 90 providing and fixing double action hydraulic floor spring of approved brand and manufacture is : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece m.s. sheet outer box with slide plate etc. complete as per the direction of engineer in charge. with stainless steel cover plate. 91 providing and fixing stainless steel (ss 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of engineerin charge complete. 355 x 19 mm. 92 interior work 93 false ceiling 94 providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections power pressed from m.s. sheet and galvanised in accordance with zinc coating of grade 350 as per is : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to g.i. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick button wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to g.i. channel with connecting clips made out of 2.64mm diax230mm long g.i. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the engineer in charge but excluding the cost of painting with 12.5 mm thick tapered edge gypsum board conforming to is: 2095 part i, 95 sanitary items 96 plumbing 97 providing and fixing unplasticised p.v.c. connection pipe with ptmt nuts collar and bush of approved quality and colour. 98 15 mm nominal bore with 3 cm length. 99 15 mm nominal bore with 45 cm length. 100 providing and fixing ptmt ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with l.p./ h.p.h.d. plastic ball.20 mm nominal bore, 120 mm long. weighing not less than 198 gms. 101 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete : 102 15 mm nominal bore 103 20 mm nominal bore 104 25 mm nominal bore 105 providing and fixing gun metal non return valve of approved quality (screwed end) : 106 25 mm nominal bore horizontal 107 25 mm nominal bore vertical 108 providing and placing on terrace (at all floor levels) polyethylene water storage tank isi : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 109 sanitary 110 providing and laying flanged c.i. standard specials such as tees, bends, collars, tapers, caps etc., suitable for flanged jointing as per is : 1538 : upto 300 mm dia. 111 providing and laying s&s centrifugally cast (spun) iron pipes (class la) conforming to is 1536 : 112 100 mm dia. pipe 113 125 mm diameter pipe 114 providing lead caulked joints to spun iron or c.i. pipes and specials including testing of joints but excluding the cost of pig lead : 115 100 mm diameter pipe 116 125 mm diameter pipe 117 supplying pig lead at site of work. 118 providing, laying and jointing glazed stoneware pipes grade ‘a’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 200 mm diameter 119 constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) r.c.c. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 120 inside size 90x80 cm and 45 cm deep including c.i. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : with bricks with class designation 75 121 inside size 120x90 cm and 90 cm deep including c.i. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : with bricks class designation 75 122 providing and fixing square mouth s.w. gully trap grade a’ complete with c.i. grating brick masonry chamber with water tight c.i. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 100x100 mm size p type with bricks class designation 75. 123 constructing brick masonry road gully chamber 45x45x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast r.c.c. vertical grating complete as per standard design with bricks. 124 constructing brick masonry road gully chamber 110x50x77.5 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast r.c.c. horizontal grating with frame and vertical grating complete as per standard design with bricks 125 fixtures 126 providing and fixing white vitreous china pedestal type water closet (european type) with seat and lid, 10 litre low level white vitreous china flushing cistern & c.p. flush bend with fittings & c.i. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : w.c. pan with isi marked white solid plastic seat and lid. 127 providing and fixing wash basin with c.i. brackets, 15 mm c.p. brass pillar taps,32 mm c.p. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : white vitreous china surgeon type wash basin of size 660x460 mm with a pair of 15 mm c.p. brass pillar taps with elbow operated levers. 128 providing and fixing kitchen sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : white glazed fire clay kitchen sink of size 600x450x250 mm. 129 providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 130 rectangular shape 453x357mm 131 rectangular shape 1500x450 mm 132 providing and fixing 100 mm sand cast iron grating for gully trap 133 providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 134 providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors 100 mm inlet and 100 mm outlet 135 providing and fixing c.p. brass angle valve for basin mixer and geyser points of approved quality conforming to is:8931. 15 mm nominal bore 136 providing and fixing ptmt soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements. weighing not less than 106 gms. 137 providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50 cm deep and 1.8 cm thick fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of engineer incharge and finished smooth. granite stone of approved shade 138 providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. 139 providing and fixing g.i. pipes complete with g.i. fittings and clamps, including cutting and making good the walls etc. 140 internal work exposed on wall 15 mm dia. nominal bore 141 internal work exposed on wall 20 mm dia. nominal bore 142 internal work exposed on wall 25 mm dia. nominal bore 143 internal work exposed on wall 32 mm dia. nominal bore 144 concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 15 mm dia. nominal bore 145 concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall. 20 mm dia. nominal bore 146 providing and fixing g.i. pipes complete with g.i. fittings including trenching and refilling etc. external work : 147 15 mm dia. nominal bore 148 20 mm dia. nominal bore 149 25 mm dia. nominal bore 150 32 mm dia. nominal bore 151 painting g.i. pipes and fittings with synthetic enamel white paint over a ready mixed priming coat, both of approved quality for new work : 152 15 mm dia. nominal bore 153 20 mm dia. nominal bore 154 25 mm dia. nominal bore 155 32 mm dia. nominal bore 156 painting g.i. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality : 157 15 mm dia. nominal bore 158 20 mm dia. nominal bore 159 25 mm dia. nominal bore 160 32 mm dia. nominal bore 161 providing and fixing g.i. union in g.i. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 162 15 mm nominal bore 163 20 mm nominal bore 164 25 mm nominal bore 165 water harvesting system 166 construction of tube well upto 100 meter depth and above in all type of rocks by dth system and over burden to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes but excluding cost of casing pipes as per is : 2800 (part i & ii) 1979 specifications. the work would be completed after obtaining sand free water. the tube well should have a throughout bore as per nominal dia of casing pipe: 200 mm dia nominal bore 167 supply of strainer pipes made of erw m.s. black pipe isi mark of following sizes at the site of work including required size of slotting as per is:8110 1985 of following nominal bore sizes at site of work. 200 mm dia 168 supply and fixing of m.s. clamp set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 169 providing & lowering of g.i. flange pipe b class including rubber washer and nuts of 8 mm dia complete in all respect. 50 mm dia 170 development of tube well as per is specification using suitable compressor to give sand free water for required yield of the gravel packed tube well. 171 electrical g schedule 172 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi markedmms ( is:9537 p iii ) pvc conduit & its accessories, round tiles,18 swg m.s. box with earth terminal, 6 a switch, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 173 short point (up to 3 mtr.) 174 medium point (up to 6 mtr.) 175 long point(up to 10 mtr..) 176 wiring of twin control light / fan / call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) of approved make in surface / recessed isi marked mms ( is:9537 p iii ) pvc conduit & its accessories, round tles,18 swg m.s. box with earth terminal, 6 a two way switch, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required. 177 short point (up to 3 mtr.) 178 medium point (up to 6 mtr.) 179 long point(up to 10 mtr..) 180 wiring of 3 pin 6 amp. light plug point with 1.5 sq. mm fr pvc insulated unsheathed 1.1 kv grade flexible copper conductor and 1.5 sq.mm fr pvc insulated unsheathed 1.1 kv grade copper earth conductor (is:694) of approved make double lock/ isi marked single lock pvc casing capping & its accessories, 18 swg m.s. box with earth terminal, screwless cage connectors for neutral looping in switch board & falce ceiling point, 6 a switch, 6 a socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required. 181 on board 182 short point (up to 3 mtr.) 183 medium point (up to 6 mtr.) 184 long point(up to 10 mtr..) 185 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required including cutting the wall and making good the same as required. 186 20 mm 187 25 mm 188 32 mm 189 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existing surface or recessed conduit/casing capping including making connections etc. as required. 190 3x 1.5 sq.mm 191 2 x 2.5 sq. mm. + 1x1.5sqmm 192 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 193 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 194 4 x 10.0 sq.mm 195 4 x 16.0 sq.mm 196 supplying and drawing pvc jacketed with annealed bare copper inner conductor & tinned copper conductor shielding foam pe dielectric coaxial cable of approved make in existingsurface or recessed conduit/casing capping including making connections as required. 197 rg 6 198 rg 11 199 supplying and drawing pvc/ polythene insulated and pvc sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. tinned / annealed copper conductor taped &confirming to itd specification s/ws 112c &113 c of approved make in existing surface or recessed conduit/casing capping. 200 unarmoured 2 pair 201 unarmoured 10 pair 202 unarmoured 20 pair 203 unarmoured 50 pair 204 jelly filled armoured (pijf) 5 pair 205 jelly filled armoured (pijf) 10 pair 206 jelly filled armoured (pijf) 20 pair 207 jelly filled armoured (pijf) 50 pair 208 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar masking sheet conforming to is13032 & is8623 including making internal db terminations with copper lugs , testing etc. as required. double door (three phase) per phase isolation 209 2+8 way 210 2+12 way 211 providing & laying xlpe insulated / p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor armoured of is:7098 i/1554 1 approved make in ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 212 2.5 sq. mm 4 core 213 4.0 sq.mm 4 core 214 6.0 sq.mm 4 core 215 10.0 sq.mm 4 core 216 16.0 sq.mm 4 core 217 25.0 sq.mm 3.5 core 218 35.0 sq.mm 3.5 core 219 50.0 sq.mm 3.5 core 220 70.0 sq,mm 3.5 core 221 95.0 sq.mm 3.5 core 222 120.0 sq.mm 3.5 core 223 150.0 sq.mm 3.5 core 224 240.0 sq.mm 3.5 core 225 300.0 sq.mm 3.5 core 226 supplying and making one end termination with heavy duty single compression brass gland sibg type, heavy duty aluminium lugs duly crimped with crimping tool, pvc tape etc for following size of armoured pvc insulated & pvc sheathed/ xlpe aluminium conductor cable of 1100 volt grade as required of size. 227 3.5 x 25.0 sq.mm 228 3.5 x 35.0 sq.mm 229 3.5 x 50.0 sq.mm 230 3.5 x 70.0 sq.mm 231 3.5 x 95.0 sq.mm 232 3.5 x 120.0 sq.mm 233 3.5 x 150.0 sq.mm 234 3.5 x 240.0 sq.mm 235 3.5 x 300.0 sq.mm 236 4 x 2.5 sq.mm 237 4 x 4.0 sq.mm 238 4 x 6.0 sq.mm 239 4 x 10.0 sq.mm 240 4 x 16.0 sq.mm 241 supply, fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. hot dipped galvanized. 242 150mm x 50mm x 1.6mm 243 300mm x 50mm x 1.6mm 244 450mm x 50mm x 2.0mm 245 600mm x 50mm x 2.0mm 246 maintenance free gel earthing with pipe in pipe /strip in pipe technology filled with anti corrosive conductive compound (cpri tested) below the ground in 150 200 mm dia earth pit and surrounding filled with required mineral filling compound (mfc should have hygroscopic proper ty to retain the moisture for long time to create low resistance zone) and c.c. finished chamber covered with hinge type with locking arrangement c.i cover. c.i. frame of size 300mm x300mm complete testing of earth resistance as required of following sizes with pipe in pipe technology (inner pipe dia / outer pipe dia) 80 100 micron g.i. coating with pipe in pipe technology with 80 100 micron g.i. coating g.i. pipe 3000 mm long , 80/40 mm , terminal 14 mm g.i. strip 247 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 248 8 swg copper wire 249 25mm x 3mm copper strip 250 50mm x 6mm copper strip 251 25mm x 3mm g.i. ( hot dipped) strip 252 25mm x 6mm g.i. ( hot dipped) strip 253 p & f of ip20 led recessed/ surface mounted round/ sqaure non dimmable downlight with die cast aluminum housing & heat sink for heat dissipation, high purity reflector with external driver having efficiency > 85% and in compliance to iec standards. ( supplied together with luminaire) power consumption of =< 7w/10w/8w/12w/15w/18w with 100/500/750/1100/1250 lumens, system lumen, efficeancy of 70 lm / watt or 100 lm / watt output suitable to replace 1x18w/ 2x18w/2x26w cfl downlights, life time of 50000 burning hours with 70% of intial lumen maintained. cct 3000° k, 4000° k and 6000° k. fixture shall be ce compliance. 254 recessed mounting led downlight 18/20w 255 surface mounting led downlight 18/20w 256 p & f of ip20 led ceiling/ recessed/ suspended mounting light fixture made form crca sheet steel housing, high purity/ transmisivity diffuser for uniform light distrubution.high efficiency driver electronics having efficiency > 85% and in compliance to iec standards.(integral driver). power consumption of 40 w/50w/60w, 3000/3300/4200 lumens, system lumen efficiency of 70 80 lm / watt output suitable for 2x36w ftl/ 2x36w cfl/3x36w cfl light fixtures, life time of 50000 burning hours with 70% intial lumens maintained. cct 3000° k, 4000° k and 6000° k. fixture shall be ce compliance. surface mounting 36w led light 2’x2’ with acrylic/ prismatic front cover 257 p & f energy efficient direct fit (retrofit) led tube system (with integral driver), on existing fixture. power consumption of18w / 36w 1500 3000 lumens, system lumen efficiency 80 lm/watt output, life time of 50,000 burning hours with 70% initial lumen maintained. cct 3000°k, 4000°k& 6000°k. 4 led tube shape fixture 18w. 258 p/ f ip 65/ ip 66 protected street light luminaries on existing bracket. fixture made from powder coated single piece pressure die cast aluminum housing with heat dissipation fins on housing with high power leds . diffuser / glass cover for ensuring ip 65 protection for lamp and control gear compartment, system lumen output of 100 lum/watt high power led. integrated driver shall be high efficiency having efficiency more than 85 % and in compliance to iec standards. system life of 50000 burning hours with 70 % of initial lumens maintained. fixture shall be in ce compliance. ip 65 protected led street light luminaries led street light fixture 150 watt 259 supply and erection of octagonal pole of following length and dimension as per table 3 with base plate on the cement concrete foundation of m 15 /m 20 grade (1:1.5:3) with the help of anchor bolts of grade 6.8 (is 1367 p iii ). the pole shall be made of s 355jo grade steel sheet , folded lengthwise to obtained octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with is 2629. the pole shall have a weatherproof flush door and locking arrangements. the complete work shall be supervised and certified by the manufacturers for satisfactory supply, erection, testing and commissioning. 9 mtr. 260 supply, installation, testing and commissioning of copper wound transformers 33/0.433 kv, three phase, 50 hz, dyn 11, onan type , standard accessories with off load tap changer (+5% to 10% in steps of 2.5%), winding / top temperature rise of 45°c/40°c first fill oil, having permissible total loss values not exceeding 7.5% of the maximum total loss values for 11 kv as per energy efficiency level 2 at basic insulation level conferming to iss 2026 (part i to part ii), latest ammended and is 1180 part i : 2014. transformers described as above and as per the following continuous rating. 315kva 261 supply, installation, testing and commissiong of indoor type floor mounted metal clad, 11 kv incomer vcb panel up to 630 a equipped with following switchgears and accessories designed & tested as per latest standard i.e. iec 62271 200, suitable for stc 25ka/3 and iac a flr for 25ka/1sec. make of ht panel, vaccum interrupter and vcb should be of same make. 11 kv / 110 volts pt class 0.5 accuracy and 100 va burden with 1no. voltmeter (0 12 kv), analog type, selector switch for voltmeter and protection fuses/mcb for ht metering upto 12 kv on incomer, ammeter, analog type, selector switches for ammeters, microprocessor based numerical relay with o/l, e/f and s/c protection, set of dual core dual ratio 3cts of suitable ratio with sec 1 of 15 va burden and accuracy class – 0.5 for metering and class 5p10 for protection, multifunction meter. 262 sitc of dg set complete with 1500 rpm diesel engine of suitable bhp & ac brush less spdp alternator mounted on a common base frame & coupled through a flexible coupling or close coupled.alternator shall be self regulated with standard alternator protection( over voltage, over speed & under voltage). engine shall have residential silencer, up to 10 m exhaust piping , electronic / mechanical governor, manual & electric start, batteries, fuel tank ( with stand) & piping, control panel (16 g) with mccb (4p; 25 ka), ammeter, voltmeter, frequency meter, energy meter & hour meter, engine instruments panel, avm and with weatherproof, powder coated accoustic enclosure for dg set for sound attenuation fabricated from 1.6 mm crca sheet steel (structure) with side wall fabricated from 1.6 mm crca sheet and filled with foam as per cpcb norms latest amendments & is 8183 .the doors are fabricated from 1.6 mm crca sheet packed with accoustic material, floor of ms chequrred plate 5.0 mmthick, all doors/ opening are sealed with neoprene/ epdn gaskets. the enclosure has built in fuel tank, residential silencer (isolated from main dg chamber) with protection and tripping of dg set against temperature of more than 50 °c. all controls for operation of dg set are from outside the enclosure with dg control panel having microprocessor based genset monitoring and control system mccb ammeter, voltmeter, pf meter, frequency meter, kwh meter, ind. lamps etc. mounted inside enclosure , visible and accessible from outside. the enclosure should be suitable for following capacity dg sets and alternator. noise level is less than 75 db (a) at a distance of 1 mtrs. duly certified by authorized agency. complete in all respect of following capacity : radiator cooled and turbo charged 250 kva at 0.8 pf 415v 50hz 3 ?. 263 supply, installation, testing & commissioning of ht metering cubical panel as approved by discoms fabricated out of 14 swg crca sheet steel in two compartment & ms angle of size 60mmx6mm having provision for following: (i) provision for fixing trivector meter (to be supplied by discoms) (ii) provision for fixing of combined ct pt set (to be supplied by discoms) (iii)tt block (iv) 6mm bakelite sheet on all sides. 264 supply, installation, testing and commissioning of 11 kv double pole structure with air break switch having following specifications : (a) dp : double pole structure made of two nos. 9 meter long pcc poles (400 kg) & 7 nos. ms channel each of size 100 mmx50mmx2500mm complete with earthing of the structure as per rec standards in all respect with nuts, springs washers, clamps as required. (b) go:off load type gang operated 3 pole vertical flute type switch suitable for 11kv ; 400a ,3 phase, central post rotating double break isolator complete with ms hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,gi pipe of suitable length for operation.c) do: 3 nos. horizontal/vertical mounted 33kv horn gap fuse set / drop out fuse set, 33kv barrel fuses mounted on 6 nos. post insulators. (c) do: 3nos vertical / horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators (d) la:3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv oh linewith rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement gi bolts, nuts, washer etc as required. (e) jumpers: 3 no 11kv acsr conductors mounted on pin type insularors as required. general:the go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 265 fire alarm g schedule 266 sitc of microprocessor based 2 wire loop (each loop accessing 90 addressable units ) fire alarm control panel. the panel shall be able to give pin point location of addressable units via the address code for each unit. the panel shall also be able to automatically switch off all control switches when ever any alarm is triggered. the panel shall also be able to give voice announcement to individualized speakers. the panel shall have built in sounder, maintenance free batteries of minimum 15 ah of 24 volts capable of minimum of 12 hours with battery charger, rectifier. loop cards, lcd unit to indicate fire / fault signal of individual unit, built in built / external printer, to log all incoming data etc complete in all respect. 2 loop. 267 sitc manual call point complete with , glass, hammer and chain etc as required: analogue addressable type 268 sitc automatic commendable control switches for shutting downac plant, power supply, gas supply etc. response indicators. 269 sitc fault isolators for isolating shorted, dead wire and loose circuits between two successive fault isolators with automatic resetting arrangement. analogue addressable type. 270 fire fighting g schedule 271 sub head i (wet riser system pumping equipments)sitc of electric driven sprinkler / hydrant pump suitable for automatic operation consisting of the following (a) horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary sluice value on the suction side ( all items to be matching the suction side of the pump) and pressure gauge sluice value and non return valve on the delivery side side ( all of the necessary dia) and including bypass arrangement for testing of pump.(b) squirrel cage induction motor suitable for 415 v, 50 hz, ac supply of below mentioned hp for the above pump ,1450 rpm t.e.f.c confirming to ip:55 and flexible coupling and coupling guard with the pump. (c) common bed plate fabricated from mild steel channel or cast iron type1620 lpm at 70 mtr head ( 50 hp motor) 272 sitc of diesel engine drive standby pump suitable for automatic operation consisting of the following a, b, c. .the diesel driven pump shall be suitable for following discharge:(a) horizontal multi stage centrifugal suction type pump complete for delivery of below mentioned discharge complete with necessary flexible pipe, sluice value on the suction side (all items shall be matching the suction side of the pump) and pressure gauge, sluice valve and non return valve on the delivery side (all of the necessary dia) and including bypass arrangement for testing of pump.(b) water cooled diesel engine developing suitable bhp for the below mentioned discharge at 1800 rpm, flexible coupling and coupling guard with the pump, common bed plate for mounting of the engine and pump, d cushy foot, damping arrangement by cushy foot, diesel engine starting panel for starting of the engine automatically with a unit of battery of 12/24v, 88 ah, 13/21 plate, exhaust pipe of minimum 10 m length, with muffler, day oil tank of 300 1ts capacity with first charge and hand operated oil pumpingset, supply, installation, testing, & commissioning of electric driven automatic pressurization pump setc) horizontally mounted single stage centrifugal end delivery pump of below mentioned discharge with necessary sluice valve on the suction side (all items matching the suction side of the pump) and sluice valve, non return value, pressure gauge on the delivery side including by pass arrangement for testing of the working of the pumping set as required.1620 lpm at 70 mtr head ( 50 hp engine) 273 sitc of jockey pump having squirrel cage induction motor suitable for 415 v, 50 hz ac supply with synchronous speed of 2900 rpm t.e.f.c type confirming to ip:55 and flexible coupling and coupling guard with the pump ,common bed plate of fabricated mild steel channel or cast iron type. 180 lpm at 70 mtr (15 hp). 274 supplying & installing cylindrical type air vessel, 250 mm dia 1.5m high of thickness 6.0 mm m.s. complete with air release valve, safety valve, pressure gauge etc.along with two coats of red oxide and two coat of post office red enamel paint as required. 275 providing & fixing 100mm dia pressure gauge on pump deliveryline complete with shut off cock. 276 sitc of pressure switches for main, jockey, and standby pumps,including necessary wiring upto control panel and stop valve. 277 sub head ii (hydrants system) 278 providing and fixing single headed hydrant valves with flanged inletisi marked with 63 mm female instantaneous outlet of gun metalcomplete with blank cap and chain conforming to is : 5290 279 providing . 63 mm dia 15 m long reinforced rubber hose pipeconforming to is : 636 1962, part –a & isi marked with gun metalmale & female coupling wire wound with the pipe. 280 providing & fixing (1.0 m x .45 m x 0.6 m ) outdoor hosecabinet suitable for accommodating hydrants made of not lessthan 16 swg. m. s. sheet having central opening glazed doorincluding necessary locking arrangement, painting (one coat primer& two coats of paint ) and housing 2 nos. rrl hose pipe, 1 nobranch pipe. 281 providing and fixing swinging drum type hose reel isi marked 30m(l) x 20 mm (dia) rubber lined pipe with shut off nozzle of 6 mm diaincluding the cost of 25 mm dia pipe connection from riser to hosereel , all sockets, nipples, elbows and 25 mm globe valve. 282 providing and fixing isi marked three way fire brigade inlet to wetriser with non return valve complete in all respects 283 providing, fixing, jointing and testing of heavy gauge (c class ) mspipe isi marked with accessories like tees, elbows, flanged joints,reducers, compressed asbestos gaskets, nuts and bolts includingfixing the pipe with suitable flat iron strip clamps /bracket, paintingetc. complete as required for delivery/ suction manifold relating tothe pump including painting of two coats of red oxide and two coatof post office red enamel paint including all civil breakages andmaking good the same : 284 200mm dia 285 150 mm dia 286 80 mm dia 287 sub head iii (piping, valves and accessories) 288 ms (medium duty b class) pipe with cleaning,wrapping and coatingof the pipe as per is; 10221 in all kind of soil at 1.0 m depthincluding excavation as required. 289 150 mm dia 290 100 mm dia 291 80 mm dia 292 providing & fixing butterfly valve with cast iron body, cast iron discand seat of nitrile rubber bonded on bakelite with hard back to pn1.6 rating with following sizes complete with bolts, washers andcompressed asbestos gasket as required 293 150 mm dia 294 100 mm dia 295 80 mm dia 296 providing and fixing non return valve complete with bolts nuts washers and compressed asbestos gasket etc as required : 297 200 mm dia 298 150 mm dia 299 80 mm dia 300 carbon dioxide type fire extinguisher with cylinder fully charge of 4.5kg capacity. 301 providing, fixing, testing & commissioning of sprinkler heads of thefollowing type : pendant type with quartziod bulb, operating temperature at 68 deg cas per specifications. 302 providing & fixing 10 swg chrome plated brass 100 mm diadecorative flanges / escutcheon plates to be fixed at junction ofsprinkler piping with the false ceiling. 303 sub head iii (piping, valves and accessories) 304 sub head iv (fire electrical control panel) 305 supplying and making end termination with heavy copper lugs (pin/ring type) duty crimped with crimping tool, pvc tape etc of followingsize 306 1.5 sq.mm 307 10.0 sq.mm 308 35.0 sq.mm 309 supply, fabricating & installing following sizes of perforated cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with suspenders and including painting as required. 100mm x 50mm x 1.6mm 310 boundary wall g schedule 311 earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of engineer for following depths, below natural ground / road top level. in all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. depth upto 1.5 m 312 excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 313 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 314 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement all work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (as per design mix) 315 reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: m 30 grade concrete. 316 centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for foundations, footings, bases of columns, etc. for mass concrete. 317 lintels, beams, plinth beams, girders, bressumers and cantilevers. 318 reinforcement for r.c.c. work at all levels including straightening, cutting, bending, placing in position and binding all complete. thermo mechanically treated bars 319 pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : raised and cut pointing. 320 random rubble stone masonry work in cement mortar with mechanical mixer in foundation (at any level) complete as per drawing and technical specification and as per clause 1000 and 1400 of mort&h specification including all scaffolding material, labour, machinery but excluding pointing and plastering. in cement mortar 1:4 (1 cement : 4 coarse sand) 321 structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 322 earth work 323 dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 324 earth work in excavation in open area, stp, wtp, pumping station with mechanical means including dressing of sides and ramming of bottoms, including getting out the excavated material, disposal of excavated material lead upto 1000m at suitable site as per as per drawing and as per direction of engineer. (measurements for payment to be done as per standard drawings). in all type of soil upto 3.0 m depth. 325 external development 326 compacting original ground 327 loosening upto a level of 500 mm below the subgrade level watered, graded and compacted in layers by vibratory roller 8 10 tonne to meet requirement of table 300 2 for subgrade construction as per mort&h specification clause 305.3.4. 328 loosening and recompacting original ground below embankment including loosening leveling and recompacting original ground supporting embankment to facilitate placement of of first layer of embankment, scarified to a depth of 150 mm, mixed with water at omc and then compacted by rolling by vibratory roller 8 10 tonne so as to achieve minimum dry density as given in table 300 2 for embankment construction as per mort&h specification clause 305.3.4. 329 providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (wmm) base course comprising of graded stone aggregate and granular material conforming to mort&h specifications (table 400 ii) in layers of equal compacted thickness each consolidated, including pre mixing the material with water at omc in mechanical mixer (pug mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub base/ base course and compacting with power vibratory roller to achieve the desired density complete as per mort&h specification clause 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 330 cement concrete pavements 331 providing and laying lean cement concrete 1:4:8 in sub base over a prepared sub grade with coarse and fine aggregate conforming to is: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600 1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 mpa at 7 days, mixed in a batching plant, transported to site, laid manualy, compacting with surface vibrator, finishing and curing complete as per clause 601, 112 of mort&h specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 332 providing and laying un reinforced, dowel jointed, plain cement concrete mix with concrete mixer & vibrator pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to is: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed as per approved mix design, laid, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures (if required) as approved, curing compound, finishing to lines and grades complete as per drawing and as per clause 602, 112 of mort&h specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. pcc m 30. 333 providing and laying cast in situ cement concrete m 20 grade kerb stone channel top and bottom width 115 and 165 mm respectively, 250mm high laid with kerb laying machine, on 150 mm thick pcc m10 grade foundation (laid manually) as per design, including fixing at site as per clause 408 of mort&h specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. using concrete mixer. 334 providing and fixing of 60mm thick precast cement concrete interlocking paver block casted with rubber moulds in approved reflective colour and design having minimun compressive strength of 300 kg/ sq cm. the cc paving blocks be laid on average 50mm thick bed of coarse sand and the joint is to be filled with fine sand. laying procedure on compacted sub base as defined. complete job is to be executed as per the instruction of engineer incharge. the rates to be inclusive of all lead & lifts etc. complete as per specifications. 335 flooring with cobble stone of approx. size 125x125x75 mm (thick) laid on 25 mm average thick cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of engineer in charge. 336 providing at site, lowering & laying in trenches, aligning & jointing of rcc pipes np4 class (with s/s ends) is: 458 2003 (amended up to date) marked and pipes from 300 mm and upto 1800 mm manufactured through vertical casting process at all depths with rubber gaskets (epdm/sbr) for sewer lines as per is: 5382 (including cost of rubber gaskets, lubricants) as per drawing, sectional hydro testing of the sewer pipe line (including cost and conveyance of water to site for testing) etc., complete as per specification and / or as directed by engineer. note : e/w to be measured and paid separately. 300 mm internal diameter. 337 horticulture work 338 grassing with doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. in rows 7.5 cm apart in either direction. 339 supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 900 mm min. height plants at site in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 340 ficus panda 341 tecoma capensis ( ratanjot) 342 clerodendron inermii ( choti aari) 343 tabernaemontana variegated ( chandni) 344 hamelia patens ( firebush, thal kamal) 345 hibiscus variegated ( guddal) 346 supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 300 mm min. height ground covers at site in 0.3 m dia holes, 0.3 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 347 wedelia trilobata ( sunflower family) 348 alternathera green (parrot leaf) 349 iresine herbstii (blood leaf) 350 ophiopogon black ( lily turf, mondograss) 351 asparagus myerii (fox tail) 352 lantana sellowiana 353 rhoeo spathacea compacta‘ ( oyster, boat lily) 354 golden duranta 355 pennisetum setaceum (fountain grass) ...

Mohan Lal Sukhadia University - Rajasthan

31667958 miscellaneous work at mds hostel mlsu earthwork in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 mtr. including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50 mtr. all kind of soils. 2 providing and laying in position cement concrete including curing compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size ) 3 filling available excavated earth ( excluding rock ) in trenches plinth side of foundation etc. in layers not exceeding 20 cm in depth consolidation each deposited layer by ramming and watering including lead up to 50 mtrand with all lift. 4 carriage of earth including loading, unloadiing etc lead up to 1 km 5 excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto distance of 100 mtr. including trimming bottom and side slope in accordance with requirement of lines, grades and corss sections. 6 p & f plain fiber glass sheet ( frp sheet fiber reinforcement product sheet conforming to is: 12866 1989 having minimum thickness as below including fixing with nuts, bolts hooks and bitumen washer etc. complete:3.0 mm thick ( wt. 5.0 kg / mtr.sq ) 7 steel work in built up tubular trusses including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete above plinth level upto 4.5 mtr height.hot finished welded type tubes. 8 providing corrugated g.i. sheet roofing fixed with g.i. j or l hooks bolts and nuts 8mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coat of approved paint on over lapping of sheet complete ( upto a pitch of 60 degree ) & excluding the cost of purlins rafters and truses, for class of sheets. 1.60mm thick 9 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand ) 10 plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish:25mm thick 11 plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish:20mm thick 12 dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable materialwithin 50 mtr lead.in cement mortar 13 dismantling stone rubble masonry including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead.in cement mortar for thickness of tiles 25mm to 40mm 14 providing and fixing external grade board solid core ( tripple core ) single leaf boiling water and termite resistant flush door shutters isi 2202 67 marked using phenol formaldehyde resin in glue both sides with approved steel fittings complete as per annexurea. decorative teak veneer both sides ( factory fitted ) 35 mm thick 15 p / f ist quality vitrified porcelain polished tiles on floor skirting and steps etc. in different sizes ( thickness to be specified by manufacturer ) with water absorption less than 0.08% and confirming to is:15622 of approved make in all colour and shade, laid with 20mm thick c.m. 1:4 including grouting the joints white cement and matching pigment etc. complete size 600mmx600mm 16 providing and fixing ist quality mat finished ceremic tiles size 400x 400 mm confirming to is: 13755 & is: 15622 colour such as white, grey, ivory, fume red brown in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry including nicely finished joints using water proof joint filler powder and finishing with flush pointing in white cement mixed with pigment to match the shade of tile complete ( including the cost of cement mortar bed 1:4 ) . 17 providing and fixing ist quality standard white / ivory, grey, fuma red brown, light green, light blue and other light shades glazed tiles of ( confirming to is : 13753 & is 13622 ) of size 300 mm x 450 mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete ( excluding the cost of cement plaster on walls & pillars ) . 18 add extra for using coloured dark shade tiles instead of white / ivory / light grey / light green / sky blue / light brown and other ligh shade colours 19 add extra for plaster over item nocement mortar 1:4 20 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :two or more coats on new work including prepration of base with primer putty lippy complete in all respect. 21 brick masonaryin super structureup to third storeywith bricks of classdesignation 75 in cement mortar 1:6 ( 1 cement : 6 coarse sand ) 22 providing and layiny in position specified grade of cement concrete for rcc structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement ; 3 coarse sand ) and making good the joints excluding the cost of centering shuttering and reinforcement for beams, suspended floors, roofs, griders having slopes up to 15° , landings, balconies , shelves , chajjas, lintels, bands, plain window, sills , staircases and spiral staircases m20 grade design mix ( with weight batching plant only ) 23 providing and layiny in position specified grade of cement concrete for rcc structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement ; 3 coarse sand ) and making good the joints excluding the cost of centering shuttering and reinforcement for walls ( any thickness ) including attached pilasters buttresses, plinth and string courses fillets columns pillars pearsabutments posts struts etc.m20 grade design mix ( with weight batching plant only ) 24 centering & shuttering with steel plates including strutting , propping, barcing both ways with wooden members and removal of form work up to floor three level for:suspended floors, roofs, landings staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blockessills, chhajjas, lintel, beams etc. 25 providing and fabricating reinforcement for rcc workincluding straightening, cutting, bending, placing in position in binding ( including cost of binding wire ) all complete up to floor three level thermo mechanically treated bars ( conforming to relevant is:1786. ) 26 providing and fixing granite stone slab thickness 16 18 mm mirror polished and machine cut in walls, pillars, steps, shelves, counter, floors etc. laid on 12 mm ( av. ) thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand ) jointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust ) with pigment to match the shade of the granite slab complete including rubbingand polishing of.jhunjhunu / jalore ( red / choclate colour ) above 3601 cm2 slabs 27 extra for providing edge moulding to 16 18 mm thick marble stone counters . vantities etc. over item no. 7.1 & 7.2 including machines polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. 28 providing & fixing anodized aluminium work ( anodizing to be got done from approved anodizer ) for doors, windows, ventilators and partition with extruded built up standard tubular and other sections of approved make confirming tois : 733 & is: 1285 anodized transperent 81 dyed to required shade according to is:1868 ( minimum anodic coating grade ac 15 ) , fixed with rawl plugs and screws or with fixing clips or with expansion hold fasteners including necessary filling up of gap at junctions, at top, bottom and sides with required pvc / neoprene felt etc. aluminium section shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, al. tower bolt & al handle & al drop etc. all complete as per architectural drawings and the directions of engineer in charge. ( glazing and paneling to be paid for separately ) .for fixed portions. 29 do for shutters of openable doors, windows and ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required ( lockers shall be paid for separately. ) . 30 do for shutters of openable sliding , windows and making provision for fixing of fittings wherever required ( lockers shall be paid for separately. ) . 31 p&f glazing in aluminium door, window, ventilator, shutters and partitions etc. with p.v.c. / neoprene or gasket etc.complete as per the architectural drawings & the directions of engineer incharge. ( cost of aluminium snap beading shall be paid in basic item ) . with glass panes of 5.0mm thickness ( weight not less than 13.75 kg / sqm ) . 32 providing and fixing 12mm thick prelaminated three layer medium density ( exterior grade ) particle board grade i, type ii conforming to is:12823 bonded formaldehyde synthetic resin of approved brand and manufacture in paneling fixed in alluminium doors, windows, shutters and partition frames with c.p., brass / stainless steel screws etc.complete as per architectural drawings and direction of engineer incharge. prelaminated particle board with decorative lamination on one side and balancing lamination on other side. 33 p&f expanded grill made of anodised aluminium as per design and drawing having members section of 7.5mm x 6.0mm and opening of size 50 mm x 50 mm to aluminium window / vent with required screws, y and h aluminium sec ( as per drawing ) at the ends and middle joints respectively complete in all respect as per direction of engineer incharge 34 s / f fixed wire gaugeofstainless steel of 14 mesh x 24 gauge to the aluminium beading 20x3 mm with suitable screw at not exceeding 150 mm distance at all hight with all lead and lift with scaffolding. 35 p&f brass lock without handle for aluminium door, of approved quality, make & design as directed by engineer in charge. 36 p & f double action hydraulic floor spring of approved brand and manufacture to aluminium door shutter including cost of cutting floors as required embedding in floors and cover plate etc. complete as per directon of engineer in charge confirming to is:6315 make...

Military Engineer Services - Rajasthan

31643194 quotation for material and labour preparation of newly plastered concrete surfaces of walls and applying two coats of exterior grade acrylic emulsion paint over a coat of chalk whiting primer of ca no cewac / nal / 37 / 2018 19 as described in bill of quantities...

Department Of Local Bodies - Rajasthan

31523317 misc. works municipal office kotputli misc. works municipal office kotputli providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12mm (av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete green / black 1501 cm2 to 3600 cm2 tiles 2 extra for providing edge moulding to 15 18mm thick marble/ granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. granite work 3 finishing walls with textured exterior paint of required shade : new work (two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. 4 providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 5 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade two or more coats on new work 6 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 7 steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 8 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of t iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 9 dismantling of existing structures like culverts, bridges, retaining walls, cc road and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by engineer.cement concrete grade m 15 and above and pcc blocks 10 random rubble masonry with hard stone in foundation and plinth : cement mortar 1:6 (1 cement : 6 coarse sand) 11 brick work with fps bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : cement mortar 1:4 (1 cement : 4 coarse sand) 12 cement plastering including t&p, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix1:4 (1 cement : 4 fine/ coarse sand) : 13 reinforcement for r.c.c. work at all levels including straightening, cutting, bending, placing in position and binding all complete.thermo mechanically treated bars. 14 reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement : 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size 15 centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for : foundations, footings, bases of columns, etc. for mass concrete. 16 providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :in75x75mm deep chase 17 providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). 18 edging with 2nd class bricks,laid dry lengthwise,including excavation,refilling,consolidation,with a hand packing and spreading nearly surplus earth within a lead of 50 metres. 19 supply and planting following speciesbest quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes,1 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required. 20 plumeria alba ( champa) 21 gulmohar(delonix regia) 22 bottle brush(callistemon lanciolatous) 23 supplying, erecting and fixing in position specified precast rcc bench made of rcc grade m 30 consisting of 2 nos. “l” shaped base support of thickness 100 mm back height 1000mm, front height 450 mm, base width 420mm and 5 nos. rcc planks of size of 1500x100 x 50 mm and 1 nos rcc planks of 150x200x50mm including joining all parts with galvanised nuts and bolts of suitable size. all bolts to be sealed after assembly with nice finish and appearance and level complete in all respect as per direction of engineer in charge. every bench should have a manufacture‘s logo of appropriate size engraved at suitable place. ...

Rajasthan State Road Development And Construction Corporation Limited - Rajasthan

31253185 additional work in head office for home guard in vidhyadhar nagar, jaipur and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12mm (av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. south zed black above 3601 cm2 slabs 2 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12mm (av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. jhunjhunu / jalore (red/choclate/black/pink colour) above 3601 cm2 slabs 3 extra for providing edge moulding to 15 18mm thick marble/ granite/kota stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge. granite/kota stone workfull edge moulding 4 providing non slip grooves to granite/ kota stone flooring, counters, vanities etc. using groove cutter v type including machine polishing to groove to give high gloss finish etc. complete as per design approved by engineer in charge 5 providing and fixing stainless steel ( grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of engineer in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 6 providing and fixing tiled false ceiling of approved materials of size 595x595 mm in truehorizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams per sqm both side inclusive ) consisting of main “t” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet spaced at 1200 mm center to center and cross “t” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “t” at 600 mmcenterto center to form a grid of 1200x600 mm and secondary cross “t” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main “t” runners to be suspended from ceiling using gi slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm gi adjustable rods with galvanizedbutterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to centeralong main t, bottom exposed width of 24 mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by engineer in charge.gi metal ceiling lay in perforated tegular edge global white colour tiles of size 595x595mm and 0.5 mm thick with 8 mm drop made of gi sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having nrc (noise reduction coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation and backed with a black glass fiber acoustical fleece. 7 providing and fixing 12.5 mm thick tapered edge gypsum board conforming to is 2095 part i at all height false ceiling including providing and fixing of frame work made of special sections power pressed from m.s. sheet and galvanised in accordance with zinc coating of grade 350 as per is : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to g.i. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to g.i. channel with connecting clips made out of 2.64mm diax230mm long g.i. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the engineer in charge but excluding the cost of painting. 8 brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in :cement mortar 1 : 4 (1 cement : 4 coarse sand) 9 plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 12mm thick . 10 providing & applying one coat of uv resistant polymer cement based waterproofing slurry coating of approved make and quality on concrete or plastered surface as perspecifications including preparation of surface by cleaning brushing and dust removing, filling of cracks and making the surface leak proof by mixing one part of chemicalwith 2 parts of cement and 2 parts of water (covering area 1.86 sq.m/kg of chemical) including cost of cement, labour, tools & plant, scaffolding if necessary etc., complete as directed by engineer in charge.note: undulations/cracks found on the surface should be rectified with cement motor before application and the same will be paid under relavent items. 11 providing& fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade :nigeria teakwood grade i. 12 supplying and fixing wood work in frames of wall panelling, false ceiling partition wall etc. as per approved design and drawing including antitermite treatment.chir wood grade i. 13 providing and fixing wall panelling using soft wood frame of size 50x25mm @600 mm c/c in both directions duly treated with anti termite treatment making grooves painting of grooves specification and drawing using :isi 9 mm teak ply one side bwr 14 providing and applyingmelamine polish on teak wood work of approved brand and manufacture to give an even shade with twoor more coats by compressor including sand papering,wood filler coat etc complete in all respect:new surface 15 providing & fixing mica of approved make for inner/outer side of shutters with fevicol & nails completeas per approved by engineer in charge.0.8mm thick mica 16 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 17 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a:30 mm thick .decorative teakveneer one side 18 providing and fixing s.s. rod 30mm dia (304 grade ,16swg) includingbrackets fixed with c.p. brass screws and rawl plugs, etc., wherever necessary complete two side central all fittings. 19 spray painting in approved shade and approved qualitywith duco paint of required colour to give even shade with two or more coats by compressor including sand papering, nc putty filler coat etc complete in all respect as per design given by engineeer incharge on new work. 20 providing and fixing hollow core partition wall using 50x30 mm chir wood frame 600 mm c/c on both directions,door opening as per drawing with steel fittings antitermite treatment complete as per specifications using :isi 4 mm thick commercial ply with 0.80 mm mica with adhesive onboth sides. 21 providing & fixing of ward robe shutters made out of 19mm thick bwp block board isi of superior quality make. front side finishing with 4mm thick teak veneer approved make and 0.8mm thickapproved shade mica in the inner side. covering with teak wood beading 25x12mm all the sides of shutter & 35x12mm on outer frame for making good the wall joint including heavy brass s.s. fittings (handle 200mm 2 nos., tower bolt 150mm 2 nos., brass lock 1 nos., magnetic catcher 2 nos., brass hinges 75x40x2.5 mm 6 nos., ss hanger rod 20mm dia)complete with melamine polishing as per drawing and design approved by engineer in charge. 22 providingandfixingnigeria/ghana /ivory coast teakwood grade i mouldings and beadings in doors and windows size : 23 50x12 mm 24 50x20 mm 25 25x12 mm 26 25x20 mm 27 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge. (concealed work including cutting chases and making good the walls etc.,)20mm nominal outer dia pipes 28 p & f full way valve (is:778 mark) or wheel valve of approved make :20mm nominal bore.horizontal 29 providing and fixing unplasticized poly vinyl chloride (upvc) swr pipes type b for sciland waste discharge system (is:13592 : 1992 marked) of approved quality /make75 mm dia 30 providing and fixing unplasticized poly vinyl chloride (upvc) swr pipes fittings type b for sciland waste discharge system (is:13592 : 1992 marked) of approved quality /make 31 coupler75mm dia 32 bend 87.5 dg.75mm dia 33 providing and fixing sun control film, thickness of film 1 mil visible light transmittance 4 24% & solar energy transmittance 42 51% & total solar energy rejection 37 43%of approved colour and shade , complete in all respect , at all level , as directed by engineer in charge. 34 providinganderectingdirectionandplace identification retro reflectorised sign asper irc:67 madeofencapsulated lens type reflective sheeting vide clause 801.3.1, fixed over aluminium sheeting, 2 mm thickwith areaexceeding 0.9 sqm supported on mild steel angle iron posts 75 mm x 75 mm x 6 mm, 2 nos.firmly fixed to the ground by means of properly designed foundation with m 15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mmbelowgroundlevelasperapproveddrawing and morth specification clause 801 35 non bsr items 36 providing and fixing tuffened glass panels of asahi, saint gobain or any other equvialent make in straight position witch shall have 12 mm thickness and clear in appearance.this item includes all hardware fixtures like dorma magnet/pag magnet no. 1417 or any other equivalent make for floor, beam, and ceiling fitting to hold the glass in required stable position.the glass shall be sealed by 5 mm d profile white seal made from cellular epdm running through the entire profile length. 37 providing and fixing 900mm high 12mm thicktoughened glass railing using s.s.304 grade stainless steel stotted pipe 50mm (miniumum 4 mm thick) at top including fabricating ,fixtures, errecting , necessary ss screw,bolt, welding , grinding , finishing, buffing to stainless steel section etc. complete asper direction of engineer charge.work also include cost of design work on glass approved by the client. 38 supply & fixing of automatic power operated sensor sliding door opening size 4900x3200 mm(door size: 2000mm x 2400mm)remaining part from door opening (sides of the door) shall be fixed with 12mm thick toughened glass.door shall be complete with 12mm thick frameless toughenedclear glass leaf with all hardware and miscellaneous equipment. power connection and cabling: conceal within the door head unit cover. include operator, header with roller track, carrier assemblies, framing jambs, sliding door panel(s), activation, safety devices and accessories required for complete installation.accessories:• center lock housings• vertical stiles• floating header bars• door patches• channels and header bars• 12mm thick frameless toughened clear glass leaf etc.work is deemed to be completed after sucessfully demonstration to the client department. 39 supply&installationofcombinationfloor/dado(italianmarblebotticinoandblack/nero marquina)1. the best quality pre polished italian marble stone from approved quarry shall be machine cut and machine polished as specified in respective items and shall be of specified thickness and of approved quality and size, free from cracks and flakes and shall be uniform colour, with straight edges. the sides of machine cut, and machine polished stones shall have perfect right angles and surface smooth. the stone slabs shall be laid and finished on bedding of cement mortar 1:4 (1 cement: 4 coarse sand) 20 mm (average) thickness.2. the flooring work will be inclusive of 100mm high skirting which shall be flushed with the wall & with a 5mm high groove above it.3. the italian marble skirting to be laid on min 20mm thick cement mortar of ratio 1:3 (1 cement: 3 coarse sand) and joined with white cement slurry mixed with matching colour.4. the finished stone surface thus laid to the required degree as approved by the engineer in charge.5. white cement slurry should be used under slab. 40 p&f wall mounted curved shaped urinal partition with toughened glass and frosted both sides chrome finish of approved brand & size 900x450 mm with requisite hardware fitting (dorma, ozone or equvalent) completed in all respect with filling ofsilicon where necessary as per instruction of engineer in charge. 41 providing & fixing plastic film on glass of garware make or equivlentfor glass door, windows etc. complete as per design and instruction of engineer in charge 42 providing & fixing sliding cum folding ms door for campus main gate as per approve design using hollow pipe ,angle ,channel section,flats(isi marked) etc.including all necessary hinges,roller , cutting welding,bolting, wastage complete as per instruction of engineer in charge 43 providing and fixing of led strips of approved make and color with proper driver of required capacity for proper illumination of the led strip. the strip to be fixed in the coves/ glass etc in proper line and level complete and backing of 3m tape complete including connecting to the electrical point etc complete. 44 flaming treatment of granite for entrance using lpg gas and make the granite antiskid type complete on site as per complete satisfaction of the engineer in charge 45 providing and fixing roman fabric blind with manual folding mechanism,fixed on aluminium valcro fixed roman channelhaving width 32mm and weigt 284 gram per meter ,fixed on steel brackets of appropriate size ,9mm dia roman aluminium pipe at 200 mm spacing with nylon thread ,fixed at window level and curtain lift with pvc bead rope, design and colour as per instruction by engeer in charge with necessary hardware fitting, material and labour etc. complete. (vista or equivalent) the rate shall include all materials, hardware and lobour etc. complete as per instruction of engineer in charge and consultant. 46 providing and fixing roller blind curtain fixed at window level and curtain lift with pvc bead rope, design and colour as per instruction by engeer in charge with necessary hardware fitting, material and labour etc. complete. (vista or equivalent) the rate shall include all materials, hardware and lobour etc. complete as per instruction of engineer in charge and consultant. 47 supply & fixing fabric curtain (approx cost rs. 700/ to 800/ p. sqm) of superior quality and approved design. the curtain should be superior quality stitching duly backed by blackout lining cloth in approved colour design and as per sample approved.brand d decor or equivalent 48 supply & fixing sheer curtainof superior quality and approved design. ( polyester & viscose mix,gsm 115,width 56 inch) brand d decor or equivalent 49 reception table(size 8x3.5x3.75) as per drawingreception counter with pedestal storage cabinet &side storage cabinet : providing and placing reception counter counter ofrequired size with 01 nos. of movable pedestal storage cabinet and 01 no. of side storage cabinet.reception counter : reception counter shall havewriting height countertop at 750mm height and a raised counter top of 230mm depth at 1050mm heightmade up of 36 mm thick isi mark bwp plywood. top thickness 36mm thick plywoodfinished with 36mmx18mm teak wood lipping. side panels 18mm thick made ofplywood finished with 18mm teak wood lipping. all exposed surface finished with 1mm thick laminate and non exposed surface to be finished with 0.8mm thick laminate of approved shade and brand. teak wood lipping to be finished with melamine polish. the cost is inclusive of all labour and material etc. complete in all respect as per drawing and direction given by engineer in charge. please refer drawings for more details.fron part shall be venner finish as per drawing with led strip light.pedestal storage cabinet : providing and placing pedestal storage cabinet of size 450lx450dx700h mm with 03 drawers made up of 18mm thick isi mark bwp plywood. top/base/sides made of 18mm thick plywood finished with 18mmx10mm teak wood lipping. drawer front/side/back made with 18mm thick plywood & drawer base in 9mm thick plywood. drawers with 14” telescopic channels of approved brand, handles in antique finish 130mm & locks of approved brand to be provided. all exposed surface finished with 1mm thick laminate and non exposed surface to be finished with 0.8mm thick laminate of approved shade and brand. teak wood lipping to be finished with melamine polish. side storage cabinet : providing and placing storage cabinet of size 1050lx450dx750h mm made up of 18mm thick isi mark bwp plywood. top & sides made of 18mm thick plywood finished with 40mmx18mm teak wood lipping.cabinet base /shelf / vertical partition / shutter made with 18mm thick plywood finished with 18mmx10mm teak wood lipping. cabinet back made with 9mm thick plywood. all exposed surface finished with 1mm thick laminate and non exposed surface to be finished with 0.8mm thick laminate of approved shade and brand. teak wood lipping to be finished with melamine polish. s.s. hinges (75x12x30mm), locks, magnet catcher, handles in antique finish(150mm) & tower bolt (75mm)of approved brand to be provided.the cost is inclusive of all labour and material etc. complete in all respect as per drawing and direction given by engineer in charge. please refer drawings for more details. 50 providing & fixing door accessories with superior quality make 51 (a). jainson handle lockgloria rose with big body 3 key handle lock 52 (b). knob lockgodrej knob lock ultra key with stainless steel finished 53 (c). door closergodrej hydraulic door closerwith stainless steel finished ...

Maharana Pratap University Of Agriculture And Technology - Rajasthan

30720615 various civil work at mechanical engineering deptt., ctae dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead.of area 3 square meter and below 8.00 each 112.00 896.00 2 brick masonary in super structure up to third storey with bricks of class designation 75 in brick work in cement mortar 1:6 ( 1 cement : 6 coarse sand ) 3.00 cum 3864.00 11592.00 3 plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish:20mm thick 36.00 sqm 140.00 5040.00 4 repair to cement plaster in cement mortar 1:6 (1 cement :6 fine sand) including removal of old plaster in regular shape and white or colour washing 50.00 sqm 168.00 8400.00 5 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :one or more coats on old work. 2200.00 sqm 61.00 134200.00 6 providing and fixing m.s. sheet single leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally bracked with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engineer in charge but excluding cost of chowkhats: including two coats of anticorrosive red oxide primer paint.:m.s. sheet 18 s.w.g. add extra for double leaf door shutter 7.00 sqm 2181.60 15271.20 7 providing and fixing t iron frames for doors windows and ventilators of mild steel teesections, joints mitred and welded with 15x3 mm lugs, 10cm long embedded in cement concrete blocks 15x10x10cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screw or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 150.00 kg 96.00 14400.00 office of the estate officer maharana pratap university of agriculture & technology, udaipur (raj.) name of work: various civil work at mechanical engineering dept., ctae. g schedule (rates are based on pwd bsr:2019, udaipur circle) 1 (a) name of contractor: 1 (d) time & date for receipt : time 12.00 noon date 21.01.2022 1 (e) time & date for opening : time 2.00 p. m. date 21.01.2022 1 (f) period of completion : two month 1 (g) special conditions 8 painting with enamel paint of approved brand and manufacture to give an even shade:two or more coats on new work...

Medical Health And Family Welfare - Rajasthan

30598597 civil work for manifold room, h.t. room at chc sultanpur distt. kota civil work for manifold room, h.t. room at chc sultanpur distt. kota earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 2 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor three level excluding the cost of centering and shuttering.m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 3 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings,strap beam, raft , bases of columns etc. 4 providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering and reinforcement including curing, compaction finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints and admixtures in recommended proportions as per is : 9103 to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of engineer in charge. m 20 grade reinforced cement concrete. all work from plinth level up to floor three level.walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 5 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.hot rolled deformed bars (is : 1139). 6 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 7 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 8 filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 9 random rubble dry stone kharanja under floor. 10 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 11 structural steel work in single section fixed with or without connecting plate including cutting, hoisting (height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. 12 steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.hot finished welded type tubes. 13 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 14 supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 15 providing and fixing square bars or other flat welded to window, ventilatiors etc. 16 providing corrugated g.i. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.1.60 mm thick with zinc coating not less than 275 gm/m2 17 supplying and fixing rough dressed stone sills, dasa, coping, cornices sriwan, string courses etc. in cement mortar 1 : 4 including pointing with admixture of pigment matching with the stone shade : 100 mm thick. 18 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 19 providing and fixing m.s. sheetsingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paintm.s. sheet 20 s.w.g.extra for double leaf shutters. 20 providing and fixing m.s. sheetsingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paintm.s. sheet 20 s.w.g. 21 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 25 mm thick slab. 22 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 23 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 24 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 25 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi markedmms ( is:9537 p iii ) pvc conduit & its accessories, round tiles,18 swg m.s. box with earth terminal, 6 a switch, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.short point (up to 3 mtr.) 26 medium point (up to 6 mtr.) 27 long point(up to 10 mtr..) 28 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade(is:694) of approved makein surface / recessed isi marked mms ( is:9537 p iii ) pvc conduit & its accessories, 18 swg 175 mm x 100 mm x 60 mm m.s. box with earth terminal,6 aswitch, 6 a socket, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.on board 29 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required.20 mm 30 25 mm 31 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.2 x 2.5 sq. mm. + 1x1.5sqmm 32 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 33 supplying and fixing of power plug point accessories on 18 swg metal box of size 175 x 100 x 60 mm. on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. switch and socket outlet, making connection , testing , etc. as required. 34 p & f surface/recessed type 10 mm thick teak wood board duly antitermite treated, varnished and fixed by using gutties/ pvc fasteners of following size as required.250 mm x 300 mm 35 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required.single pole mcb 6 a to 32 a rating 36 double pole mcb 40 a 63 a rating 37 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required.double door (single phase) 8 way 38 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. 39 p & f is:371 marked6 amp surface type ceiling rose including making connection testing etc. as required. 40 p & f isi marked6 amp bakelite batten/angle holder including making connection testing etc. as required. 41 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.10.0 sq.mm2 core 42 plate earthing as per is:3043 with g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 43 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm sweep 44 p&f of heavy duty capacitor start, double ball bearing900/1400 rpm single phase isi marked exhaustfan,is:2312 marked in existing opening including making connections testing etc. as required.300 mm sweep(900/1400 rpm) 45 supply & fixingisi marked( is : 15683 )portable fire exitnguisher, abc type,finished externally with red enamel paint, completein all respects includinginitial fill and wall suspension of following capacity.4 kg 46 p & f of ip 65 protected led street light fixture 70 75 wall (with surge protection device 10ka) applicable for area lighting with extruded pressure diecast aluminium housing, system lumens efficacy of 100 lm/watt minimum, toughened glass with diffuser, suitable lenses on led, 240v,50 hz of high power led lamps supplied with pre wired cable of 1 mtr. integrated driver shall be high efficiency having efficiency > 85% and in compliance to iec standards system life of 50,000 burning hours, cri >80, pf>0.90 at full load, cct 5700 6500 k (per direction of engineer incharge]. fixtures shall be ce compliance. ...

Medical Health And Family Welfare - Rajasthan

30598591 civil work for manifold room, h.t. room at chc siswali distt. baran earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 2 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor three level excluding the cost of centering and shuttering.m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 3 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings,strap beam, raft , bases of columns etc. 4 providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering and reinforcement including curing, compaction finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints and admixtures in recommended proportions as per is : 9103 to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of engineer in charge. m 20 grade reinforced cement concrete. all work from plinth level up to floor three level.walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 5 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. hot rolled deformed bars (is : 1139). 6 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 7 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 8 filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 9 random rubble dry stone kharanja under floor. 10 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 11 structural steel work in single section fixed with or without connecting plate including cutting, hoisting (height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. 12 steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.hot finished welded type tubes. 13 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 14 supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 15 providing and fixing square bars or other flat welded to window, ventilatiors etc. 16 providing corrugated g.i. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.1.60 mm thick with zinc coating not less than 275 gm/m2 17 supplying and fixing rough dressed stone sills, dasa, coping, cornices sriwan, string courses etc. in cement mortar 1 : 4 including pointing with admixture of pigment matching with the stone shade : 100 mm thick. 18 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 19 providing and fixing m.s. sheetsingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paintm.s. sheet 20 s.w.g.extra for double leaf shutters. 20 providing and fixing m.s. sheetsingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paintm.s. sheet 20 s.w.g. 21 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 40 mm thick slab. 22 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 23 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 24 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 25 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi markedmms ( is:9537 p iii ) pvc conduit & its accessories, round tiles,18 swg m.s. box with earth terminal, 6 a switch, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.short point (up to 3 mtr.) 26 medium point (up to 6 mtr.) 27 long point(up to 10 mtr..) 28 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade(is:694) of approved makein surface / recessed isi marked mms ( is:9537 p iii ) pvc conduit & its accessories, 18 swg 175 mm x 100 mm x 60 mm m.s. box with earth terminal,6 aswitch, 6 a socket, 3.0 mm thick isi marked phenolic laminated sheet, zinc plated / brassscrews, cup washers, making connections, testing etc. as required.on board 29 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall, covering conduit and making good the same as required.20 mm 30 25 mm 31 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.2 x 2.5 sq. mm. + 1x1.5sqmm 32 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 33 supplying and fixing of power plug point accessories on 18 swg metal box of size 175 x 100 x 60 mm. on surface or in recessed with suitable size phenolic laminated sheet cover including cost of 6 pin 16 amp. switch and socket outlet, making connection , testing , etc. as required. 34 p & f surface/recessed type 10 mm thick teak wood board duly antitermite treated, varnished and fixed by using gutties/ pvc fasteners of following size as required.250 mm x 300 mm 35 p&f 240/415 v ac mcb with positive isolation of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections, testing etc. as required.single pole mcb 6 a to 32 a rating 36 double pole mcb 40 a 63 a rating 37 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required.double door (single phase) 8 way 38 p & f socket size flush type 120/280 watt rotary 5 step fan regulator including making connection testing etc. as required. 39 p & f is:371 marked6 amp surface type ceiling rose including making connection testing etc. as required. 40 p & f isi marked6 amp bakelite batten/angle holder including making connection testing etc. as required. 41 p/laying p.v.c./ xlpe insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i / is :7098 p i of group 1 of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.10.0 sq.mm2 core 42 plate earthing as per is:3043 with g.i. earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 25mm dia. g.i. b class watering pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and c.c.finished chamber covered with hinged type with locking arrangement c.i. cover,c.i. frame of size300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. 43 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.1200 mm sweep 44 p&f of heavy duty capacitor start, double ball bearing900/1400 rpm single phase isi marked exhaustfan,is:2312 marked in existing opening including making connections testing etc. as required.300 mm sweep(900/1400 rpm) 45 supply & fixingisi marked( is : 15683 )portable fire exitnguisher, abc type,finished externally with red enamel paint, completein all respects includinginitial fill and wall suspension of following capacity.4 kg 46 p & f of ip 65 protected led street light fixture 70 75 wall (with surge protection device 10ka) applicable for area lighting with extruded pressure diecast aluminium housing, system lumens efficacy of 100 lm/watt minimum, toughened glass with diffuser, suitable lenses on led, 240v,50 hz of high power led lamps supplied with pre wired cable of 1 mtr. integrated driver shall be high efficiency having efficiency > 85% and in compliance to iec standards system life of 50,000 burning hours, cri >80, pf>0.90 at full load, cct 5700 6500 k (per direction of engineer incharge]. fixtures shall be ce compliance. ...

Department Of Local Bodies - Rajasthan

30397882 finishing work in yadav samaj ward no.3 sanwad providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3mm m.s. gusset plates at the junctionsand corners, all necessary fittings complete, including applying a priming coat of approved steel primer.using m.s. angels 40x40x6 mm for diagonal braces. 2 brick work with fps bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in :cement mortar 1:6 (1 cement : 6 coarse sand) 3 cement plastering including t&p, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :1:6 (1 cement : 6 fine/ coarse sand) 4 providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rail of t iron 40x40x6mm with 40mm dia, steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer 5 steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 6 kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :area of each slab 900 to 2000 sqcm 7 p & f double ball bearing capacitor start ceiling fan of approved make complete with regulator and other accessories as required. (for estimation purpose only.1400 mm sweep 8 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq.mm fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) of approved make insurface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,18 swg m.s. box with earth terminal, screwless cage connectors for neutral looping in switch board & false ceiling point. 6 a switch, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.short point (up to 3 mtr.) 9 long point (up to 10 mtr..) 10 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm fr pvc insulated unsheathed flexible copper conductor 1.1 kv grade and 1.5 sq.mm fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade(is:694) of approved make in surface / recessed isi marked medium duty pvc conduit & its accessories, 18 swg m.s. box with earth terminal, screwless cageconnectors for neutral looping in switch board & false ceiling point, 6 a switch, 6 a socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.short point (up to 3 mtr.) 11 long point (up to 10 mtr..) 12 p & f surface/recessed type 10 mm thick teak wood board duly antitermite treated, varnished and fixed by using gutties/ pvc fasteners of following size as required.175 mm x 75 mm 13 200 mm x 250 mm 14 wall painting with plastic emulsion paint of approved brand andmanufacture to give an even shade:two or more coats on new work 15 painting with synthetic enamel paint of approved brand and manufacture to give an even shade :two or more coats on new work 16 providing corrugated g.s. sheet roofing including vertical/ curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275gm/m² ...

Public Works Department - Rajasthan

30264754 02 various works in mppg college chittorgarh 02 various works in mppg college chittorgarh part a water hut 2 earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. all kinds of soil. 3 providing and laying in position cement concrete including curing compaction etc . completein specified grade excluding the cost of centering and shuttering. all work up to plinth level using crusher broken aggregate1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 4 random rubble stone masonry for foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6( 1 cement : 6 sand ) 5 random rubble dry stone kharanja under floor 6 filling in plinth withlocally available river shingle under floors including watering ramming consolidating and dressing complete including cost of river shingles. 7 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formworks for foundation in basement rafts, footings, straps beams, bases of columns etc. up to plinth level. 8 providing and laying in position specified grade of reinforcement cement concrete all rcc structural elements upto plinth levelincluding curing compaction finishing with rendering in cement sand mortar 1:3 ( 1 cement : 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement m20 grade nominal mix (with graded stone aggregate 20mm nominal size) 9 brick work in super structure up to third storeycement mortar 1:6 ( 1 cement : 6 coarse sand ) 10 half brick masonry in superstructure up to third storey including cost of nominal hoopreinforcement ( 2 nos. 6 mm dia m.s. bar at every forth course )cement mortar 1:4 ( 1 cement : 4 coarse sand ) 11 35mm thick rough chiesel dressed stone flooring of approved shade set in pattern over 20mm thick base of cement mortar 1:6 ( 1 cement : 6 coarse sand) and jointed with cement sand mortar 1:3 complete in all respects:nimbahera stone 12 providing and fixing granite stone slab thickness 16 18 mm mirror polished and machine cut in walls, pillars, steps, shelves, counter, floors etc. laid on 12 mm (av.) thick base of cement mortar 1:3(1 cement : 3 coarse sand) jointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of.green/black/other graniteabove 3601 cm2 slabs 13 extra for providing edge moulding to 16 18 mm thick marble stonecounters . vantities etc. over item no. 7.1 & 7.2 including machines polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge.granite work 14 providing and laying in position specified grade of cement concrete for rcc structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement forbeams, suspended floors, roofs, griders having slopes up to 150 , landings,balconies , shelves ,chajjas, lintels, bands ,plain window, sills ,staircases and spiral staircases m 20 grade nominal mix (with graded stone aggregate 20mm nominal size) 15 centering & shuttering with ply wood or steel sheets including shuttering , propping, barcing both ways with wooden members and removal of form work up to floor three level for:suspended floors, roofs, landings staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blockes sills, chhajjas, lintel, beams etc. 16 plaster on new surface on wall in cement sand mortar 1:6 including raking of joints etc. complete fine finish:20mm thick 17 6 mm cement plaster to ceiling of mix 1:3 ( 1 cement : 3 fine sand) 18 polished blue kota stone flooring skirting laid over 20mm thick base of cm 1:4 and jointed with gray cement slurry to match the shade of the slab including rubbing and polishing completefor area of each slab from2001sq.cm to 5000 sq.cm20 mm thick slab 19 supplying and fixing in walls machine cut and polished stone shelves tands and sills in cm 1:3 with machine cut edgeskota stone 25 to 30 mm thick 20 grading roof water proofing treatment with :cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) with water proofing compound as per manufacturss specification 21 providing & laying broken glazed titles on 20mm thick in plain cement mortar 1:4 (broken glazed tiles not less than 9 kg/sqm) and joints filled with white cement with water proofing compund all complete as per direction of engineer in charge. 22 providing and fixing precast cement concrete coping 1:2:4 mix 50 mm thick complete as per specification: 23 providing batta (gola) 75mm x 75mm in cement concrete (1:2:4) including finishing with cement mortar 1:3 as per standard design. 24 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm, long embedded in cement concrete block 15x10x10cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with coper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer excluding the cost of metal beading and other fitting except necessary hings of pivots steel handles peg stay etc. as required.partly fixed and partly openable (fixed area not to exceed 33 %). 25 providing and fixing square bars or other flat welded to window ventilatiors etc. 26 s&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by aluminium beading 20x3 mm with suitable screwsat not exceeding 150mm distance at all height with all lead and lift with scaffolding 27 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexurea30 mm thick commercial veneer both sideadd extro for sunmica 0.8 mm thick. 28 providing and fixing fully panelled double leaf shutter for doors as per approved design and drawing with approval ordinary c.p./oxidised steel fittings as per annexure a and width of styles & top rails of 100 mm and lock rails width of 150 mm and bottom rails of 200 mm width including teak wood beading of size 19 mm x12 mm on both faces complete. 30 mm thick wood sqm local wood gr i wire gauge 24 gauge 14 mesh of is designation 85 gauge wires of dia 0.58 mm panels 29 providing and fixing pressed steel mitred doors frames manufactured from commercial mild steel sheet of 1.25 mm ( 16 gauge) thickness including hings jamb, lock jamb, head and if required angles threshold of mild steel angles of section 50x25mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split and tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre treatment of the surface as directed by engineer in charge.double pitam door frameprofile e : 165 x 60 30 applying birla /jk white cement based putty over cement plaster surface for making even surface 31 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade :two or more coats on new work including prepration of base with primer putty lippy complete in allrespect. 32 finishing walls with acrylic smooth exterior paint of required shade including all scaffolding.new work (two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 33 providing and fixing in position collapsible steel shutters with vertical m.s. , channels 20x10x2mm and bracket with flat iron diagonals 20x5mm, size with top and bottom rail of t iron 40x40x6mm . with top flat of 50 x 10 mm and bottom flat of 40 x 6 with 40mm dia steel pulleys/ ball bearing complete with bolts, nuts locking arrangements inside and outside stoppers, handles etc. as per specification including applying a priming coat of approved steel primer ( to be measured and paid as per outer dimension).with 75 mm opening when closed. 34 painting with enamel paint of approved brand and manufacture to give an even shade:two or more coats on new work 35 p&f seal coat with gril patti cement mortar 1:2, reinforced with 6mm wire fine finished with primer putty, paint complete in all respect as per design & direction by engineer incharge size 18 x 14 x 3 36 p&f chattri with dome of cement concrete 1:2:4 reinforced with 8mm wire fine finished with primer putty, paint complete in all respect as per design & direction by engineer incharge size 2 x 2 x 5 37 p & f bib cock (is : 8931 mark), superior quality of approved make:) brasslong body, 15mm nominal bore weight not less than 690 gm 38 p & f grating of approved quality /make stainless steel sheet size 125 mm dia 39 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.110mm dia 40 p&f rigid pvc pipe fittings (is: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 41 bend 87.5 42 110 mm dia 43 75mm 44 plain tee 45 110 mm dia 46 75 mm 47 vent cowel 110 mm dia 48 p trap 110 mm dia 49 p & f pvc storage tank (is : 12701marked indicating the bis license no), of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000 litres capacity. 50 p & f gi pipes ( internal works ) with gi fittings excluding union(is:1239 mark) and ms clamps, including cutting and making good the wall and floors.exposed on wall25mm dia nominal boreb class 51 p & f gi pipes ( internal works ) with gi fittings excluding union(is:1239 mark) and ms clamps, including cutting and making good the wall and floors.exposed on wall15mm dia nominal boreb class 52 p & f full way valve (is:778 mark) or wheel valve of approved make :gun metal 15mm nominal bore. 53 p & f full way valve (is:778 mark) or wheel valve of approved make :gun metal 25mm nominal bore. 54 p & f ball cock (is :1703 mark) with rod & p.v.c. ball complete :brass wt.400 gm,15mm. 55 construction of open surface drain with 112mm thick brick masonry in cm 1:4,110mm thick base concrete 1:5:10, 37mm thick m 15 grade c.c. flooring ,12mm 1:4 cement plaster on all exposed faces of walls including top surface excavation & disposal of earth complete as per approved design/drawing: 112mm drain,225mmm av. depth 56 providing & laying chequerred plain cement concrete embessed to specially manufactured non slipping tiles of approved make 20mm thick laid on 20mm thick bed of cement mortar 1:6 jointed with neat cement slurry complete 57 providing and fabricating reinforcement for rcc work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three levelthermo mechanically treated bars (conforming to relevant is code.) 58 p & f 1st qualityvitrified porcelain polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to is 15622 of approved make in all colour and shade,laid with 20 mm thick cm 1 : 4 including grounting the joints with white cement and matching pigment etc complete.size 600 mm x 600 mm 59 providing and fixing of all plastic fixed louvered ventilators shall be made from extruded pvc section reinforced with steel. the corners and joints shall be mitre cut and welded the outer frame shall be made from extruded pvc section having an overall cross section of 40 x37 mm suitable snap fit moulded louver ends louver blade of pvc/glass and safety bar shall be provided. 60 providing and fixing ist quality standard white/ ivory,grey, fuma red brown, light green, light blue and other light shades glazed tiles (confirming to is : 13753 & is 13622) of size 300 mm x 200 mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete (excluding the cost of cement plaster on walls & pillars ). 61 providing and fixing to existing door frame 30 mm thick factory made polyvinl chloride (pvc) door shutter made of styles and rails of upvc hollow section of size 60x30 mm and wall thickness 2 mm +/ 0.2 mm with inbuilt decorative moulding edging on one sides. the styles and rails mitred and jointed at the corners by means of m.s. galvanised / plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless of size screws. the style of the shutter reinforced by inserting galvanised m.s. tube of size 25x20 mm and 1 mm +/ 0.1 mm wall thickness. the lock rail made up of h section, a upvc hollow section of size 100 x30 mm and 2 mm +/ 0.2 mm wall thickness fixed to the shutter style by means of plastic/ galvanised m.s. u cleats. the shutter frame filled with a upvc multi chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm +/ 0.1 mm wall thickness. the panels filled vetically andtie bar at two places by inserting horizontally 6 mm galvanised m.s. rod and fastened with nuts and washers, complete as per manufactures specifications and directon of engineer in charge including all door fittings such as hinges, l drop, handles, locking bolts etc. as per approved of engineer in charge 62 p & f indian type white glazed vitreous china ist quality w.c.orissapan (i.s: 2556 mark) with 100 mm vitreous china p or s trap including cutting and making good the wall and floor. size 580 x 440 mm 63 p & f white vitreous china double syphonic european w.c. (i.s: 2556 mark) with mounted w.v.c. flushing cistern of (i.s. 2556 mark) of 10 litre capacity complete with all necessary internal fittings including cutting and making good the wall and floor. 64 p&f ist quality wvc urinal (is :2556 mark) with 25 mm dia g.i.waste pipe, dome waste couplings, concealed iron brackets or screw etc. completeflat back (large) or half stall size 610x400x80mm 65 p & f wvc wash basin (ist quality, i.s.: 2556 mark) of approved make with c.i. brackets duly painted 1 no 15 mm c.p. pillar cock (i.s. : 8934 mark) & 32 mm c.p. brass wastecoupling of approved make, 25 mm g.i. waste pipe complete including cutting & making good the wall. 66 p & f 15 mm. dia connection pipe of approved quality/make :pvc pipe with c.p. brass nuts upto length, 600mm 67 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc.c.p. inlet connection 15mm.brass (is : 8931 marked) 68 p & f flush cock / flush valve (is : 9758 mark) for wc of approved quality make :cp brass push type 20mm nominal bore. 69 p & f beveled edge mirror of special glass of approved make (atul modi guard saint gobin orequivalent) complete with 6 mm thick asbestos cement sheet ground fixed to wooden screw & washers.size 600 x 450 mm x 4 mm thick 70 p & f full way valve (is:778 mark) or wheel valve of approved make :gun metal 15mm nominal bore. 71 p&f rigid pvc pipe (is:4985 mark) class ii/ (4 kg. /cm2.) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.75mm dia 72 construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in cm 1:6, 80mm thick stone slab, jointing of slab in cm 1 : 3, ralthal, kharanja, 40 mm thick m 15 grade c.c flooring, earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:size 300 cm. dia outside & 300 cm. depth . 73 construction of septic tank in all types of soil with 40 cm .thick masonry in cm 1:6, 15 cm thick c.c bed of 1:5:10, m 15 grade c.c flooring & over stone slab covering ,80 mm thick slab ,jointing of slab in cm 1:3. ralthal, kharanja, 50 mm thick stone partition walls, 20 mm thick plaster in cm 1:6 finished with neat floating cement, 4 nos c.i foot rests of approved design ,two no. 450 mm dia each ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr: size 400x140x150 cms (for 50 users) 74 p & f gi pipes ( external works ) with gi fittings eccluding union(is:1239 mark )and ms clamps, including trenching and refilling earth etc.25mm dia nominal boreb class 75 centering & shuttering with ply wood or steel sheets including shuttering , propping, barcing both ways with wooden members and removal of form work up to floor three level for:walls (any thickness) including attached pilasters, buttresses, plinth and string course. 76 providing and laying in position specified grade of cement concrete for rcc structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement ; 3 coarse sand) and making good the joints excluding the cost of centering shuttering and reinforcement forwalls (any thickness) including attached pilasters buttresses, plinth and string courses fillets columns pillars pears abutments posts struts etc.m25 grade design mix 77 p & f inlet connection (angle valves) superior quality, of approved make, for wash basin, gyser etc.c.p. inlet connection 15mm.brass (is : 8931 marked) ...

Kendriya Vidyalaya Sangathan - Rajasthan

30163399 bids are invited for enamel, exterior, (a)undercoating, (b) finishing is:2933 (q3) , plastic emulsion paint is:15489 (q3) , gum spirit ofturpentine oil is:533 (q3)mse total quantity : 48...

Department Of Local Bodies - Rajasthan

29957791 miscellaneous construction related work in administrative city camp abhiyan ward 45 prasasan sahro ke sang aayojit shivir abiyan ke tahat nirman se sambandit vibin karya. 1 carriage of materials by mechanical transport including loading, unloading and stacking ::earth upto 5km 1.00 cum 165.00 165.00 2 dismantling stone masonry.rubble stone masonry in cement mortar. 1.00 cum 256.00 256.00 3 demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineerincharge.in cement mortar 1.00 cum 284.00 284.00 4 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 1.00 sqm 21.00 21.00 5 earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of engineer for following depths, below natural ground / road top level.in all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.depth upto 1.5 m 1.00 cum 164.00 164.00 6 providing and fixing stone slab covering of required size over drains including filling of joints with cement sand mortar 1:3 complete as per direction of engineer in charge.average thickness 60 to 75 mm 1.00 sqm 458.00 458.00 7 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level :1:5:10 (1 cement : 5 fine/ coarse sand : 10 graded stone aggregate 40 mm nominal size) 1.00 cum 3120.00 3120.00 8 providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 1.00 cum 4280.00 4280.00 9 centring and shuttering with plywood or steel sheet upto two stories or height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for :foundations, footings, bases of columns, etc. for mass concrete. 1.00 sqm 162.00 162.00 price schedule (this boq template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. bidders are allowed to enter the bidder name and values only ) percentage boq tender inviting authority: name of work: prasasan sahro ke sang aayojit shivir abiyan ke tahat nirman se sambandit vibin karya. (this tender amt. rs. 30.00) contract no: ruidp sor2017 validate print help 10 providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement all work upto plinth level :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 1.00 cum 4960.00 4960.00 11 reinforcement for r.c.c. work at all levels including straightening,cutting, bending, placing in position and binding all complete.cold twisted bars 1.00 kg 51.50 51.50 12 brick work with modular bricks of class designation 75 in foundation and plinth in:cement mortar 1:6 (1 cement : 6 coarse sand). 1.00 cum 3460.00 3460.00 13 half brick masonry with fps bricks of class designation 75 in superstructure above plinth level upto two stories.cement mortar 1:4 (1 cement :4 coarse sand) 1.00 sqm 528.00 528.00 14 random rubble masonry with hard stone in foundation and plinth :cement mortar 1:6 (1 cement : 6 coarse sand) 1.00 cum 3190.00 3190.00 15 providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 & is :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 1.00 sqm 679.00 679.00 16 providing and fixing 1st quality mat finished ceremic tile size 300x300mm confirming to is : 13755 and is : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 1.00 sqm 666.00 666.00 17 providing & fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade :sal wood 1.00 cum 67200.00 67200.00 18 providing and fixing fully panelled/partly panelled/ double leaf shutter frame for doors as per approved design and drawings with approved ordinary c.p./ oxidised steel fittings as per annexure a and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :35 mm thick.nigeria wood grade i 1.00 sqm 2870.00 2870.00 19 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesin in glue both sides including approved isi marked stainless steel butt hinges fittings with necessary screws complete as per annexure a :25 mm thick.decorative teak veneer both side 1.00 sqm 2260.00 2260.00 20 steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 1.00 kg 87.50 87.50 21 providing and fixing gi wire gauge of average width of aperture 1.56mm with wire of 0.45mm to existing steel door, window shutter frames with necessary m.s. strip beading 20x3mm with suitable screw at not exceeding 150mm distance etc. complete. 1.00 sqm 495.00 495.00 22 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6mm angle iron and 3mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.using m.s. angels 40x40x6 mm for diagonal braces. 1.00 sqm 2790.00 2790.00 23 providing and fixing factory made isi marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges, pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design. 1.00 kg 128.00 128.00 24 random rubble dry stone kharanja (soling) under floor. 1.00 cum 1360.00 1360.00 25 providing and fixing on wall face unplasticised rigid pvc single socketed pipes rain water pipes conforming to is : 13592 type a including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion.75 mm diameter 1.00 mtr 155.00 155.00 26 110 mm diameter 1.00 mtr 253.00 253.00 27 providing and fixing on wall face unplasticised pvc moulded fittings/ accessories for unplasticised rigid pvc rain water pipes conforming to is : 13592 type a including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal expansion.coupler75 mm 1.00 each 100.00 100.00 28 110 mm 1.00 each 152.00 152.00 29 single tee with door75x75x75 mm 1.00 each 187.00 187.00 30 110x110x110 mm 1.00 each 316.00 316.00 31 single tee without door.75x75x75 mm 1.00 each 173.00 173.00 32 110x110x110 mm 1.00 each 286.00 286.00 33 bend 87.5°75 mm bend 1.00 each 101.00 101.00 34 110 mm bend 1.00 each 128.00 128.00 35 providing and fixing unplasticised pvc pipe clips of approved design to unplasticised pvc rain water pipes by means of50x50x50mm hard wood plugs, screwed with m.s. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc.complete.75 mm 1.00 each 169.00 169.00 36 110 mm 1.00 each 173.00 173.00 37 cement plastering including t&p, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :1:6 (1 cement : 6 fine/ coarse sand) 1.00 sqm 192.00 192.00 38 neat cement punning 1.00 sqm 37.00 37.00 39 distempering with oil bound washable distemper of approved brand and manufacture to give an even shade.new work (two or more coats) over and including priming coat with cement primer. 1.00 sqm 86.00 86.00 40 finishing walls with water proofing cement paint of required shade :new work (two or more coats applied @ 3.84 kg/10 sqm). 1.00 sqm 55.50 55.50 41 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:two or more coats on new work 1.00 sqm 80.50 80.50 42 painting with synthetic enamel paint of approved brand and manufacture to give an even shade :two or more coats on new work 1.00 sqm 69.00 69.00 43 repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead :with cement mortar 1:4 (1 cement : 4 fine sand) 1.00 sqm 234.00 234.00 44 removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 1.00 sqm 9.50 9.50 45 finishing walls with water proofing cement paint of required shade :old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of priming coat. 1.00 sqm 53.00 53.00 46 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and testing of joints complete as per direction of engineer in charge.internal work exposed on wall.15 mm nominal outer dia .pipes. 1.00 mtr 171.00 171.00 47 25 mm nominal outer dia .pipes. 1.00 mtr 288.00 288.00 48 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer in charge.concealed work including cutting chases and making good the walls etc.,15 mm nominal outer dia .pipes. 1.00 mtr 277.00 277.00 49 25 mm nominal outer dia .pipes. 1.00 mtr 424.00 424.00 50 providing and fixing chlorinated polyvinyl chloride (cpvc) pipes, having thermal stability for hot & cold water supply including all cpvc plain & brass threaded fittings. this included jointing of pipes & fittings with one step cpvc solvent cement, trenching, refilling & testing of joints complete as per direction of engineer in charge.external work.15 mm nominal outer dia .pipes. 1.00 mtr 146.00 146.00 51 25 mm nominal outer dia .pipes. 1.00 mtr 262.00 262.00 52 providing and fixing brass bib cock of approved quality :15 mm nominal bore 1.00 each 215.00 215.00 53 providing and fixing brass stop cock of approved quality :15 mm nominal bore 1.00 each 240.00 240.00 54 providing and fixing ball valve (brass) of approved quality, high or low pressure, with plastic floats complete :25 mm nominal bore 1.00 each 478.00 478.00 55 providing and fixing gun metal non return valve of approved quality (screwed end) :25 mm nominal bore.horizontal 1.00 each 784.00 784.00 56 providing and placing on terrace (at all floor levels) polyethylene water storage tank isi : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 1.00 per litre 6.50 6.50 57 supplying and fixing c.i. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg. 1.00 each 285.00 285.00 58 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete.flexible pipe.40 mm dia 1.00 each 56.00 56.00 59 providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:with average thickness of 120mm and minimum thickness at khurra as 65 mm. 1.00 sqm 874.00 874.00 60 earth work for sewer line and manhole in excavation in foundation, trenches manholes, road side chambers etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of engineer for following depths, below natural ground / road top level including allowances for any additional excavation beyond the drawings (measurement for payment to be as per standard drawings), re handling of material/earth to complete the task.in all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc. depth upto 1.5 m 1.00 cum 197.00 197.00 61 dismantling of flexible pavements for sewer line and manholes and disposal of dismantled materials up to a lead of 50 metres as directed by engineer including allowances for any additional dismantling beyond the drawings (measurement for payment to be as per standard drawings), re handling of material/earth to complete the task.bituminous courses 1.00 cum 356.00 356.00 62 granular courses 1.00 cum 247.00 247.00 63 dismantling of cement concrete pavement for sewer line and manholes by mechanical means using pneumatic tools, cutting the peripheral edge by cc cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 metres including allowances for any additional dismantling beyond the drawings (measurement for payment to be as per standard drawings), rehandling of material/earth to complete the task. 1.00 cum 802.00 802.00 64 providing and laying in position cement concrete 1:3:6 (1 cement : 1 graded stone aggregate 20 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration under sewer line and manhole work including allowances for any additional road restoration beyond the drawings (measurement for payment to be as per standard drawings) to complete the task 1.00 cum 4500.00 4500.00 65 providing and constructing of sewer brick masonry circular manholes of type a with internal dia 0.90m and depth upto 1.65m having 230mm thick sewer brick masonry wall in cement sand mortar 1:4, including concreting pcc m 10 grade (1:4:8) for 225mm thick foundation including curing compaction and form work etc complete, pcc m15 for benching and channel portion, rcc m20 for 200mm thick cover slab including reinforcement, pcc m20 for fixing the manhole frame and cover using stone aggregate 20mm nominal size, 20mm thick inside and outside plaster in c. m. 1:3, inside plaster finished with floating coat of neat cement, vata in cm1:1 around pipe entering and leaving the manhole and also at the junction of masonry and concrete slab, providing and fixing of sfrc foot steps of approved make at every 0.30m height fixed in cm 1:3, supplying and fixing heavy duty sfrc manhole frame and cover as per is 12592 (part i and ii) having clear opening of 560mm, including refilling of jhiri, including curing, watering, ramming, hydro testing of manhole, conveyance & cost of water, and dewatering complete as directed by the engineer. manhole type a of depth 0.90 m 1.00 each 11500.00 11500.00 66 providing and making connection to the manhole/ road side chamber/ property chamber by cutting hole in wall, making good the same with brick work/ stone masonry work in cement mortar 1:4, plaster in cement mortar 1:3, encasement of pipe at manhole with 75mm thick m15 grade concrete etc complete as directed by engineer 1.00 each 707.00 707.00 67 raising precast circular manhole cover and frame by taking out existing precast frame and cover, providing and fixing precast sfrc circular spacer of height 100/125/150mm, re fixing existing manhole cover frame and cover with cement sand mortar (1:3), including making good the damage, complete as directed by engineer. 1.00 each 1510.00 1510.00 68 lowering of circular manhole with circular cover 600mm dia and frame slab to required level including dismantling existing slab and manhole wall, taking out the existing ci frame & cover of manhole and lowering it upto ground/ road level, refixing of frame and cover in m15 (1:2:4) concrete all around the frame, including making good the damage, form work, curing, complete as directed by engineer. 1.00 each 445.00 445.00 69 supplying & fixing 560mm dia sfrc manhole frame & cover as per is : 12592 2002 in existing manholes including grouting the frame in pcc m 15 complete in all respect as directed by the engineer.hd 20 1.00 each 2400.00 2400.00 70 providing, jointing, laying, testing and commissioning of hdpe pe100/pn 6 (suitable for pulling method for jointing) pipes for sewer line as per is 14333 by trenchless method adopting any suitable technology below ground at required depth including carriage etc. complete in all respect, construction of thrust pit and receiving pit of required size upto 3 metre depth and soil investigation, making suitable arrangement for barricading of pits, traffic diversion, lights, traffic permission from relevant authority (though department will assist in getting the permission), refilling of pits in compacted layers of 150 mm including disposal of surplus material with all lift and lead upto 50 metre as per specification and the direction of the engineer.in all types of soil .200 mm dia hdpe pipe . 1.00 meter 2260.00 2260.00 71 cleaning and flow test of rcc/sw pipes already laid but not commissioned (including cost and conveyance of water to site) complete in all respect as per direction of engineer in charge. 200 mm dia 1.00 meter 41.00 41.00 72 constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast r.c.c. horizontal . grating with frame complete as per standard design : with bricks ...

Urban Improvement Trust - Rajasthan

29927206 various miscellaneous work in converted colony, uit scheme in savina, savina kheda, titradi, dhol ki pati. 5908 earth work in excavation in foundation trenches or drains including dressing of sides and ramming of bottoms, lift up to 1.5 mtr, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr. all kinds of soil. 2 item code [2019 12.67]:item type [building] ::sub item code [2019 12.67 + 12.67.1]: wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including prepration of base with primer putty lippy complete in allrespect. 3 item code [2019 12.68]:item type [building] ::sub item code [2019 12.68 + 12.68.1]: painting with enamel paint of approved brand and manufacture to give an even shade: two or more coats on new work 4 item code [2019 12.8]:item type [building] ::sub item code [2019 12.8 + 12.8.2]: plaster on new surface on wall in cement sand mortar 1:4 including raking of joints etc. complete fine finish: 20mm thick 5 item code [2019 3.12]:item type [building] ::sub item code [2019 3.12 + 3.12.4]: s & fcc 1:2:4 (m 15) precast kerb on dand upto 60 cm length over 20mm thick base of cement mortar 1:6 including jointing, earthwork, painiting and jointing with cement mortar 1:4 of size. 15 x 40 cm 6 item code [2019 3.2]:item type [building] ::sub item code [2019 3.2 + 3.2.2]: providing and laying in position cement concrete including curing compaction etc . completein specified grade excluding the cost of centering and shuttering. all work up to plinth level using crusher broken aggregate m20 grade nominal mix (with graded stone aggregate 20mm nominal size) 7 item code [2019 3.2]:item type [building] ::sub item code [2019 3.2 + 3.2.4]: providing and laying in position cement concrete including curing compaction etc . completein specified grade excluding the cost of centering and shuttering. all work up to plinth level using crusher broken aggregate m10 grade nominal mix ( with graded stone aggregate 20mm nominal size) 8 item code [2019 4.12]:item type [building] ::sub item code [2019 4.12 + 4.12.2]: providing and fabricating reinforcement for rcc work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete up to floor three levelthermo mechanically treated bars (conforming to relevant is:1786.) 9 item code [2019 4.6]:item type [building] :: centering and shuttering with steel plates/ plywood sheet including strutting, propping bracing both ways and removal of formworks for foundation in basement rafts, footings, straps beams, bases of columns etc. up to plinth level. 10 item code [2019 9.19]:item type [building] :: providing and fixing steel gate grating and grills made of angles, tees, square bars orflats black pipe with holdfast and fittings complete as per deign and drawing including cutting welding and fabrication with priming coat of red oxide. 11 item code [2019.11.58]:item type [building] :: sub item code [2019.11.58 + 2019.11.58.2]: providing and fixing of precast concrete interlocking block of m 30 grade manufactured from fully computerised automatic stationery hydraulic vibropressed machine and fully computerised automatic batching plant of class a1/a2 as per bs 6717:2001 with rubber mould technology including painting with lacker polising. the cc interlocking paving blocks be laid on average 50 mm. thick bed of coarse sand and the joint on is to be filled with fine sand. laying procedure on compacted sub base as defined. complete job is to be executed as per the instruction of engineer incharge. the rates to be inclusive of all lead, lifts and taxes general specification of blocks:1) shape as defined by engineer incharge 2) tensile splitting strength and braking load as per bs 6717:20013) color : grey cement natural colour.4) variation in dimension : less than 1.6 mm.5) variation in thickness : less than 3.2 mm.6) abrasion : as per bs : 6717:2001 80mm thick interlocking blocks ...

Sarva Shiksha Abhiyan Authority - Rajasthan

29304143 civil work at gsss sangasar block ratangarh sl. no. item description 1 part a civil work 2 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means over areas ( exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan ) including disposal ofexcavated earth, lead upto 50m andlift upto 1.5 m , disposed earth to be levelled and neatly dressed:all kinds of soil 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 1:4:8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) . 4 random rubble stone masonary for foundation and plinth in cement sand mortar above 30 cm. thick wall in :cement mortar 1:6 ( 1 cement:6 sand ) . 5 providing & laying chequered terrazzo tiles of approved make 22mm thick with marble chips of size upto 6mm, in floors, jointed with neat cement slurry mixed wit pigment to match the shade of tiles including rubbing and polishing complete in all respect as per specification, on 28mm thick bed of c.m. 1:4 :dark shade using ordinary cement. 6 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix / design mix providing m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 7 supply & stacking good earth at site complete including loading unloading & transporation etc. 8 brick work with clay flyash f.p.s. brick ( is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) 9 stone kharanja: random rubble dry stone kharanja under floor 10 half brick masnory with clay flyash f.p.s. brick ( is 13757 1993 ) of class designation 75 in superstructureaboveplinth level upto floor five level in :cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) 11 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor walls ( any thickness ) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix / design mixproviding m 25 grade concrete by using min 410 kg of cement per cum instead ofm 20 grade design mix. 12 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 ( 1 cement: 3 coarse sand ) and making good the joints and cost of plastizers ( as required ) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 13 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchorblocks, sills, chhajjas, lintel, beam, plinth beam etc. 14 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. 15 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : columns, pillars, posts and struts etc. 16 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding ( including cost of binding wire ) all complete up to floor five level. thermo mechanically treated bars ( conforming of relevent is code ) 17 structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m ) , fixing in position and applying a priming coat of approved steel primer all complete. 40×40×5mm 3kg per rmt 18 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint extra for double leaf shutters. 19 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section ( is 1038 1983 ) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 ( 1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size ) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33% ] 20 supplying and fixing fixed wire gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150 mm distance.14 mesh x 24 gauge 21 guard bars:providing and fixing square bars or other flat welded to window, ventilatiors etc. 22 kota stone slab flooring 25 mm thick over 20 mm ( average ) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) for area of each slab from 2001 to 5000 sq.cm 23 kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average ) thick cement mortar 1:3 ( 1 cement 3 coarse sand ) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete for area of each slab from 2001to 5000 sqcm 24 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 12mm thick. 25 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 26 plaster ( ceiling ) : 6 mm thick cement plaster to ceiling of mix1:3 ( 1cement : 3 fine sand ) 27 making grooves as per design in plaster 10mm to 20mm wide. 28 green board : plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :12mm thick 29 m15 grade nominal mix 1: 2: 4 ( 1 cement : 2 coarse sand : 4 graded stoneaggregate 40mm nominal size ) . 30 providing gola 75x75 mm in cement concrete 1:2:4 ( 1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge ) includingfinishing with cement mortar 1:3 ( 1 cement : 3 fine sand ) as per standard design : 31 providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete 32 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 33 finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: new work ( two or more coats applied @ 3.84 kg / 10 sqm ) . 34 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 35 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxideextra if square, rectangular hollow tubularsections are used 36 copping:m20 grade nominal mix1: 1.5: 3 ( 1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size ) . 37 p&f rigid pvc pipe ( is:4985 mark ) class ii / ( 4 kg. / cm2. ) approved quality / makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 38 p&f rigid pvc pipe fittings ( is: 4985 mark ) of approved quality / make including joining the pipe with solvent cement rubber ring and lubricant: bend 87 .5 110mm dia 39 pipe clip110 mm dia 40 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills, counters. floors etc. laid on 12mm ( av. ) thick base of cement mortar 1:3 jointing with white cement mortar 1:2 ( 1 white cement: 2 marble dust ) with pigment to match the shade of the marble slab complete including grinding, rubbing and polishing of:above 3601 cm2 slabs 41 providing and fixing 20 mm thick precast terrazo tiles of approved make, with marble chips of size upto 6mm laid over roof with neat cement slurry mixed with pigment to match the shade of the tiles, including cutting , grinding rubbing with machinecomplete on 20 mm thick bed of cement sand mortar 1 : 4. 42 part b sanetarywork 43 p & f kitchen & lab. sink of approved make with c.i. brackets duly painted 40 mm c.p. waste coupling c.p. brass chain with rubber plug, 40 mm g.i. waste pipe up to floor level complete including cutting and making good the wall & floor. ( wvc lab sink ( i.s 2556 mark ) size 530 x430x180 mm ) 44 p & f chromium plated swan neck laboratory cock of approved quality / make: one way. 45 p & f bib cock ( is : 8931 mark ) superior quality of approved make.c.p. brass 400 gm, 15 mm nominal bore. 46 p & f ball cock ( is : 1703 mark ) with rod & p.v.c. ball complete.brass wt. 400 gm, 15 mm 47 p & f inlet connection ( angle valves ) superior quality of approved make c.p. intel connection 15 mmbrass ( is : 8931 ) 48 p & f 15 mm dia connection pipe of approved quality make pvc pipes with nuts 450 mm. 49 p & f full way valve ( is : 778 mark ) or wheel valve of approved make. gun metal 15 mm nominal bore. 50 p & f stop cock ( is:8931 mark ) , superior quality and of approved mark: brass 400 gm. 15 mm nominal bore 51 p & f pvc storage tank isi marked ( is: 12701 ) indicating the bis license no. of approved make with cover, 25mm dia 1 m long g.i. overflow pipe & 25 cm longwash out pipe with plug & socket including making connection etc. complete of approved design 500 litres capacity 52 p&f gi pipes ( external work ) with gi fittings excluding union ( si: 1239 mark ) including trenching and refilling each etc. 15 mm dia nominal bore b class 53 providing & fixing ist quality standard white, gray, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to is : 13753 and is: 15622 of size 300mm x 200mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of tile complete ( excluding the cost of cement plaster on walls and piller ) 54 part c electrical work 55 wiring of light point / fan point / exhaust fan point / call bell point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1kv grade ( is: 694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked ( is:9537 p ii ) rigid steel conduit & its all accessories, round tiles, 18 swg g.i.box with earth terminal, 6 a switch, 3 pin ceiling rose / lamp holder / 3 point connector, 3.0 mm thick isi markedphenolic laminated sheet, pvc bushes, check nuts, al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessoriesrefer chapter e 04, e 05 & e 07 .for additional technical parameters of products / work, referannexure a attached with this bsr . 56 light point 57 short point ( up to 3 mtr. ) 58 medium point ( up to 6 mtr ) 59 long point ( up to 10 mtr ) 60 fan point 61 short point ( up to 3 mtr. ) 62 medium point ( up to 6 mtr ) 63 long point ( up to 10 mtr ) 64 wiring of 3 / 5 pin 6 amp. light plug point as per pwd specification for electrical works with isi marked 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv grade ( is:694 ) and 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade ( is:694 ) inrecessed isi marked ( is:9537 p ii ) rigid steel conduit & its all accessories, required size 18 swg, g.i. box with earth terminal, 6 aswitch, 3 / 5 pin 6 a socket, 3.0 mm thick isi marked phenoliclaminated sheet, pvc bushes, check nuts, al. alloy / cadmium plated iron screws 20 mm cup washers etc. all as per pre approved by engineer in charge, making connections, testing etc. complete as required.for specification of copperconductor, phenolic laminated sheets & electrical / wiring accessoriesrefer chapter e 04, e 05 & e 07 .for additional technical parameters of products / work, referannexure a attached with this bsr . on board 65 s&f following sizes ( dia. ) of isi marked ( is:9537 p ii ) rigid steel conduit of apropriate thickness related to its dia as per pwd specification for electrical works along with accessories inrecessed using saddles, clamps, fasteners, pvc bushes, check nuts, screwas etc. as required includingcutting the wall and making good the same as required all as per pre approved by engineer in charge.for additional technical parameters of products / work, referannexure a attached with this bsr . 25 mm 66 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor as per pwd specification for electrical works with isi marked ( is:694 ) and as per is 8130 : 2013 of 1.1 kv grade . wire should be made from99.99% purity copper, class 5 stranding in acc. to iec 60228 forlower watt loss , oxygen free ( <10 ppm ) for less chances of oxidization and higher silver content for gives better conductivity , insulation pvc type a , flame retardant as per is 10810 53, better amperage rating as per vde 0298 part 4, , in existingsurface or recessed pvc / ms conduit / casing capping includingall as per pre approved by engineer in charge, making connections, etc. as required. oem must have its own in house nabl lab setup for all testing facilities for wires. for additional technical parameters of products / work, referannexure a attached with this bsr . 67 1 x 1.5 sq. mm 68 2 x 1.5 sq. mm 69 2 x 2.5 sq. mm 70 providing & fixing of 240 / 415 v ac mcb with positive isolation of breaking capacity not less than 10 ka ( b / c tripping characteristic as per type of load andsite requirement ) 4kv impulse withstand voltage, as per pwd specification for electrical works with isi marked is 8828 ( 1996 ) / conforming to iec 60898 1 2002, iec 60947 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per iec, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , ip 20 contact protection and fitted withexisting distribution board / sheets, min. operation 20, 000 upto 32 a rating and 10, 000 upto 63 a, 5000 for 80 a ratingincluding making connections, testing etc. as required.. oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 6 a to 32 a rating 71 providing & fixing of ik09 recessed / surface mounting heavy duty horizontal type sheet steel of 1.6 mm thickdistribution board as per pwd specificationfor electrical works isi marked conforming to is 13032 & is 8623 / conforming to iec 61439 3. phosphatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link , connecting wire of suitable rating and din bar, masking sheet, including making internal dbterminations with copper lugs and with detachable gland plate, including making connections, testing etc. as required.oem shall have submitnabl / cpri / erda accrediated lab test reportsbefore execution & all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . ip 43 double door ( single phase ) 8 way ( 8 o / g +2 i / c ) 72 providing & fixing of ip40 led recessed / surface mounted, round / sqaure non dimmable back lit smd mid power led downlight with die cast aluminum housing & heat sink for heat dissipation with uv stabilized non yellowish diffuser with internal / external bis complience 2.5 kv surge protected isolated driver, with short & open circuit protection, having efficiency > 85% and in compliance to iec standards. system lumen efficacy of = 120 lm / watt, thd < 10 % , p.f.=0.95, cri >80, life time of minimum50000 burning hours with , 70% of intial lumen maintaned till life ends, cct 3000°k / 4000°k / 5700°k / 6000°k / 6500°k ( as per ansi bin ) , maximum power consumption should not more than the specified rating and fixture shall be ofbis standard andtrade mark certificate ( t.c. ) . manufactures word mark / name engraved / embossing / screen printing onhousing. oem must have its own in house nabl lab setup for all testing facilities for led fixtures. ( lm79 / lm80 ) certificate / report from oem shall be submitted. all as per pre approved by engineer in charge . foe additional technical parameters of product / work, refer annexure a attacheded with this bsr.surface mountingled downlight 18 / 20w 73 providing & laying p.v.c. / xlpe insulated & p.v.c. sheathed un armoured / armoured copper cable of 1.1 kv grade as per pwd specification for electrical worksin existing rcc / hume / stoneware / pvc pipe / open duct / cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points ( a ) , ( b ) , ( c ) , mentioned below: ( a ) copper conductor of electrlytic grade copper, purity >99.97 % isi marked as peris:1554 p i / is :7098 p i 6.0 sq. mm 4 core 74 providing & fixing of iso certified company made beestar rated copper wounded double ball bearing capacitor start, aluminium body & metallicblade ceilingfanas per pwd specification for electrical works, conforming to is:374 2019, & is:1885 p v 1981. with down rod up to 30 cm with secondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.appropriate oem test certificate shall be submitted by contractor. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 1200 mm sweep bee 3 star rated ( service value >=5.0 to< 5.5 ) 75 providing & fixing ofisi marked ( is:371 ) 6 amp surface type 3 pin ceiling roses as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal & captive screws including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 76 providing & fixing of isi marked ( is:1258 ) 6 ampbatten / angle lampholder as per pwd specification for electrical works, made out from industrial grade polycarbonate or fire resistant abs material, brass terminal & captive screws including making connection testing etc. as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 77 p & f 18 swgm.s. recessed fan box, hexagonal / round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 100 mmlength extended on each side . all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 78 providing & fixing of 18 swg g. i. / m .s. sheet boxesas per pwd specification for electrical works, duly finished with two coats of red oxide and with earthing terminal of following sizes ( nominal size ) in recessed / surface as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr .175mm x 100mm x 60mm 18 swg m. s. sheet boxes 79 providing & fixing of paper phenolic resin bondedlaminates confirming to is : 2036 1995 for boxes / frames including making holes for switches etc, with brass / zinc plated screws, washers, nut and bolts as required. all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 3.0 mm thick 80 providing & fixing of modular type step fan regulator duly isi marked ( is :11037 ) as per pwd specification for electrical works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith ip 20 rating , minimum width of 1 module switch toggle ( push part ) should not less then 20mm, includingall as per pre approved by engineer in charge, making connections, testing etc. as required.all as per pre approved by engineer in charge.for additional technical parameters of products / work, refer annexure a attached with this bsr . 5 step fan regulator 100 watt 2 module 81 p & f socket size flush type 120 / 280 watt rotary 5 step fan regulator including making connection testing etc. as required....

Department Of Atomic Energy - Rajasthan

29263793 bids are invited for enamel, synthetic, exterior: (a) under coating (b) finishing paint is:2932 , plastic emulsion paint is:15489 , putty is:419 total quantity : 390...

Panchayat Raj Department - Rajasthan

28925330 fanicial year 2021 22 material supply for mgnrega in gp sankra fanicial year 2021 22 material supply in gp sankra , dismantling stone slab/ terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 2 demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge.1: 3: 6 or richer mix. 3 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 4 earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 sqm on plan including disposal of excavated earth up to 50 mtr. and lift up to 1.5 mtr. disposed soil to be levelled and neatly dressed:all kinds of soil 5 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m10 grade nominal mix 6 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m15 grade nominal mix 7 brick masonry with f.p.s. bricks of class designation 75 infoundation and plinth with bricks 8 brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in :cement mortar 1 : 4 (1 cement : 4 coarse sand) 9 plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :20mm thick 10 plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :20mm thick . 11 cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 12 finishing with neat cement (punning). 13 stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of engineer in charge 14 extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 15 steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.hot finished welded type tubes.for parking shed 16 supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 17 structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete. 18 providing and fixing cow catcher made of r.s. joist angles channels ms rounds including cutting welding and fabrication with priming coat of red oxide (as per design). gate 3 nos. 19 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 20 supply and installation of multi rib proofing/cladding sheet manufacture out of0.50mm tct (total coated thickness) high tensile zinc aluminum alloy coated galvaiumeseel (as per 150gsm zinc aluminum coated 550mpa tuekd strength) confirming to is: 1397/astm a 792 sheet to have wide pens 30mm high nb at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. the sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding. 21 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 22 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 23 providing and fixing designer cement concrete polished tiles over 20mm average thick base of cm 1 :4 (1 cement : 4 sand) jointing with cement mortar 1 :2 ( 1cement : 2 sand) with pigment to match the shade of the tiles complete with all respect. 24 providing and laying at or near ground level factory made kerb stone of m 25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand ) including making joints with without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete including painting etc. as per direction of engineer in charge (length of finished kerb edging shall be measured for payment). (precast c.c. kerb stone shall be approved by engineerin charge). 25 p & f pvc storage tank isi marked (is : 12701) indicating thebis license no),of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity. 26 hoisting charges for each floor :for items 2.26.5 to 2.26.8 27 p & f g.i. pipes (external work) with g.i. fittings excluding union (is : 1239 mark) including trenching & refilling earth etc. 28 50mm dia nominal bore b class 29 25mm dia nominal bore b class 30 15mm dia nominal bore b class 31 making connection of g.i. distribution branch with g.i. main including all fitting. 32 upto 25mm dia 33 beyond 25mm & upto 100mm dia 34 p & f gun metal non return valve or check valve (is :make) of approved make, superior quality:50mm nominal bore. vertical 35 p & f full way valve (is:778 mark) or wheel valve of approved make : 36 gun metal 50mm nominal bore. 37 gun metal 25mm nominal bore. 38 gun metal 15mm nominal bore. 39 p & f ball cock (is :1703 mark) with rod& p.v.c. ball complete : 40 brass wt. not less than 300 gm,15mm. 41 ( do ) wt.not less than 600 gm, 25mm. 42 p & f push cock superiorquality, of approved makec.p. brass 15 mm. 43 supply & fixing g.i. union isi marked in g.i. pipe line as required complete in all respect of size : 44 50mm dia nominal bore 45 25mm dia nominal bore 46 15mm dia nominal bore 47 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint 48 supplying and fixing machine cut fine dressedred/pink sand stone dasa orcoping,with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 75 mm thick 49 repair of existing steel glazed doors, windows and ventilator, ms sheet door, garge doors, compound wall gates etc. by welding drilling complete include. cost of welding rods and hire charge of welding meachine and tp etc complete 50 providing and fixing 12.5 mm thick tapered edge gypsum board conforming to is 2095 part i at all height false ceiling including providing and fixing of frame work made of special sections power pressed from m.s. sheet and galvanised in accordance with zinc coating of grade 350 as per is : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to g.i. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to g.i. channel with connecting clips made out of 2.64mm diax230mm long g.i. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the engineer in charge but excluding the cost of painting. 51 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:old work (one or more coats ) 52 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a:30 mm thick . 53 extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) over item no. 8.13. 54 providing& fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade : 55 providing and fixing fully panelled/partly panelled/double leaf shutter frame for doors as per approved design and drawings with approved ordinary c.p./ oxidised steel fittings as per annexure a and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : 56 providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). panelling for panelled and glazed shutter 25 mm to 40 mm thick8 mm thick glass 57 extra for providing is 1341 1992marked stainless steel butt hinges instead of black enamelled m.s. butt hinges with necessary screws. (shutter area to be measured). 58 extra for providing other type of fittings as mention in annexure a ( as approved by ei) :brass fittings 59 providing and applyingmelamine polish on teak wood work of approved brand and manufacture to give an even shade with twoor more coats by compressor including sand papering,wood filler coat etc complete in all respect: 60 carriage of building rubbish stone metal (grit and ballast etc.) ...

Development Authority - Rajasthan

28925323 miscellaneous civil works in ravindra manch, jaipur miscellaneous civil works in ravindra manch, jaipur dismantling stone slab / terrazo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 2 demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge.1: 3: 6 or richer mix. 3 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.all kinds of soils 4 earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 sqm on plan including disposal of excavated earth up to 50 mtr. and lift up to 1.5 mtr. disposed soil to be levelled and neatly dressed:all kinds of soil 5 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m10 grade nominal mix 6 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m15 grade nominal mix 7 brick masonry with f.p.s. bricks of class designation 75 infoundation and plinth with bricks 8 brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in :cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) 9 plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish :20mm thick 10 plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :20mm thick . 11 cement concrete flooring 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate ) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 12 finishing with neat cement ( punning ) . 13 stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4, with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of engineer in charge 14 extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 15 steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m ) fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.hot finished welded type tubes.for parking shed 16 supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 mtr. apart 30cm in ground embedded in cement concrete 1:3:6 ( 30x30x45cm ) corner and every tenth post to be strutted with ( 50 x 50 x 6cm ) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size. 17 structural steel work in single section fixed with or without connecting plate including cutting, hoisting ( height upto 10 m ) , fixing in position and applying a priming coat of approved steel primer all complete. 18 providing and fixing cow catcher made of r.s. joist angles channels ms rounds including cutting welding and fabrication with priming coat of red oxide ( as per design ) . gate 3 nos. 19 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 20 supply and installation of multi rib proofing / cladding sheet manufacture out of0.50mm tct ( total coated thickness ) high tensile zinc aluminum alloy coated galvaiumeseel ( as per 150gsm zinc aluminum coated 550mpa tuekd strength ) confirming to is: 1397 / astm a 792 sheet to have wide pens 30mm high nb at 250 centre and centre width of 1020mm shets be casted with regular modified plyster system on a continuous with line on centre for face and with a polyster coating respectively sheet shall have proportionality with siphoned plate at made at to prevent leakage sheet shall be fixed by more of sell drilling lift tapping hot dip zinc coated hox head fasterner of size 12x14x55mm long. the sheet shall be supplied in cost one length and foe a minimum up to 12mts with all scaffolding. 21 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m20 grade nominal mix1: 1.5: 3 ( 1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size ) . 22 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : 23 providing and fixing designer cement concrete polished tiles over 20mm average thick base of cm 1 :4 ( 1 cement : 4 sand ) jointing with cement mortar 1 :2 ( 1cement : 2 sand ) with pigment to match the shade of the tiles complete with all respect. 24 providing and laying at or near ground level factory made kerb stone of m 25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand ) including making joints with without grooves ( thickness of joints except at sharp curve shall not to more than 5mm ) including making drainage opening wherever required complete including painting etc. as per direction of engineer in charge ( length of finished kerb edging shall be measured for payment ) . ( precast c.c. kerb stone shall be approved by engineerin charge ) . 25 p & f pvc storage tank isi marked ( is : 12701 ) indicating thebis license no ) , of approved make with cover, 25mm dia 1m long g.i. over flow pipe & 25 cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity. 26 hoisting charges for each floor :for items 2.26.5 to 2.26.8 27 p & f g.i. pipes ( external work ) with g.i. fittings excluding union ( is : 1239 mark ) including trenching & refilling earth etc. 28 50mm dia nominal bore b class 29 25mm dia nominal bore b class 30 15mm dia nominal bore b class 31 making connection of g.i. distribution branch with g.i. main including all fitting. 32 upto 25mm dia 33 beyond 25mm & upto 100mm dia 34 p & f gun metal non return valve or check valve ( is :make ) of approved make, superior quality:50mm nominal bore. vertical 35 p & f full way valve ( is:778 mark ) or wheel valve of approved make : 36 gun metal 50mm nominal bore. 37 gun metal 25mm nominal bore. 38 gun metal 15mm nominal bore. 39 p & f ball cock ( is :1703 mark ) with rod& p.v.c. ball complete : 40 brass wt. not less than 300 gm, 15mm. 41 ( do ) wt.not less than 600 gm, 25mm. 42 p & f push cock superiorquality, of approved makec.p. brass 15 mm. 43 supply & fixing g.i. union isi marked in g.i. pipe line as required complete in all respect of size : 44 50mm dia nominal bore 45 25mm dia nominal bore 46 15mm dia nominal bore 47 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint 48 supplying and fixing machine cut fine dressedred / pink sand stone dasa orcoping, with full moulding if required laid on cement mortar 1:4 including pointing with admixture of pigment matching with the stone shade. 75 mm thick 49 repair of existing steel glazed doors, windows and ventilator, ms sheet door, garge doors, compound wall gates etc. by welding drilling complete include. cost of welding rods and hire charge of welding meachine and tp etc complete 50 providing and fixing 12.5 mm thick tapered edge gypsum board conforming to is 2095 part i at all height false ceiling including providing and fixing of frame work made of special sections power pressed from m.s. sheet and galvanised in accordance with zinc coating of grade 350 as per is : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of 25x25x0.55mm of required length, and other end of angle hanger being fixed with nut and bolts to g.i. channels 45x15x0.9mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to g.i. channel with connecting clips made out of 2.64mm diax230mm long g.i. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the engineer in charge but excluding the cost of painting. 51 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:old work ( one or more coats ) 52 providing and fixing external grade board solid core single leaf flush door shutters isi 2202 67 marked using phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure a:30 mm thick . 53 extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters ( over all area of door shutter to be measured ) over item no. 8.13. 54 providing& fixing door, window, chowkhats and other frames, including antitermite treatment, m.s. flat, hold fasts of size 250 x 40 x 3mm fixed with m.s. bolt 5mm dia 50mm long duly embedded in cement concrete m 15 grade : 55 providing and fixing fully panelled / partly panelled / double leaf shutter frame for doors as per approved design and drawings with approved ordinary c.p. / oxidised steel fittings as per annexure a and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete : 56 providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows ( area of opening for panel inserts excluding portion inside grooves or rebates to be measured ) . panelling for panelled and glazed shutter 25 mm to 40 mm thick8 mm thick glass 57 extra for providing is 1341 1992marked stainless steel butt hinges instead of black enamelled m.s. butt hinges with necessary screws. ( shutter area to be measured ) . 58 extra for providing other type of fittings as mention in annexure a ( as approved by ei ) :brass fittings 59 providing and applyingmelamine polish on teak wood work of approved brand and manufacture to give an even shade with twoor more coats by compressor including sand papering, wood filler coat etc complete in all respect: 60 carriage of building rubbish stone metal ( grit and ballast etc. ) ...

Public Works Department - Rajasthan

28879170 various civil works in govt. polytechnic college bikaner 2 dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 3 dismantling stone slab / terrazzo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 4 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) .cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) . 5 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc upto floor five level excluding the cost of centering and shuttering. m15 grade nominal mix 1: 2: 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 6 providing and fixing 50 mm thick cement concrete flooring with metallic concrete hardener topping, under layer of 38 mm thick cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm thick nominal size ) and top layer of 12 mm thick metallic concrete hardener consisting of mix 1:2 ( 1 cement : 2 stone aggregate, 6 mm nominal size ) by volume & mixed with metallic hardening compound of approved quality @ 2 kg. / sqm including cement slurry, rounding off edges etc. but excluding the cost of nosing of step etc. complete. 7 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 8 providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying :a ) after surface preparation, first layer of slurry of cement @ 0.488 kg / sqm mixed with water proofing cement compound @ 0.253 kg / sqm.b ) laying second layer of fiber glass cloth when the first layer is still green. overlaps of joints of fiber cloth should not be less than 10 cm.c ) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg / sqm mixed with water proofing cement compound @ 0.670 kg / sqm and coarse sand @ 1.289 kg / sqm. this will be allowed to air cure for 4 hours followed by water curing for 48 hours. the entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.d ) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. ( which will be paid for separately ) for the purpose of measurement the entire treated surface will be measured. 9 supplying and fixing in walls machine cut and polished stone shelves, tands and in cm 1:3 with machine cut edges : sand or other approved stone 50 mm thick. 10 providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting, welding and fabrication with priming coat of red oxide : 11 p & f g.i. pipes with g.i. fittings excluding union ( is : 1239 mark ) including trenching & refilling earth etc. : ( external work ) medium duty pipes : 50 mm dia nominal bore. 12 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc upto floor five level excluding the cost of centering and shuttering. m15 grade nominal mix1: 2: 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size ) . 13 kota stone slab flooring 25 mm thick over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : for area of each slab from 2001 to 5000 sq. cm. add extra for combined flooring kota stone & marble flooring : for marble flooring area upto 20%. 14 part b : smart class room of civil department 15 dismantling stone slab / terrazzo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 16 demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge : in cement mortar. 17 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) .cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) . 18 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc upto floor five level excluding the cost of centering and shuttering. m15 grade nominal mix 1: 2: 4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) . 19 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 20 removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandal / loi and all scaffolding. ( for colour changing only ) . 21 6 mm thick cement plaster to ceiling of mix 1:3 ( 1 cement : 3 fine sand ) . 22 providing and fixing 12.5 mm thick tapered edge gypsum board conforming to is 2095 part i at all height false ceiling including providing and fixing of frame work made of special sections power pressed from m.s. sheet and galvanised in accordance with zinc coating of grade 350 as per is : 277 and consisting of angle cleats of size 25 mm wide × 1.6 mm thick with flanges of 22 mm and 37 mm at 1200 mm centre to centre one flange fixed to the ceiling with dash fastener 12.5 mm dia × 40 mm long with 6mm dia bolts to the angle hangers of 25×25×0.55 mm of required length, and other end of angle hanger being fixed with nut and bolts to g.i. channels 45×15×0.9 mm running at the rate of 1200 mm centre to centre to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450 mm centre to centre shall be fixed in a direction perpendicular to g.i. channel with connecting clips made out of 2.64 mm dia × 230 mm long g.i. wire at every junction including fixing the gypsum board with ceiling section and perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall / partition with the help of rawl plugs at 450 mm centre to centre with 25 mm long drive all screws @ 230 mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer suitable for board as per manufactures specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the engineer in charge but excluding the cost of painting. 23 dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead : of area 3 square meter and below. 24 providing and fixing aluminium work for doors, windows, ventilators and partition with extruded built up standard tubular / appropriate z sections and other sections of approved make conforming to is:733 and is:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gap. at junctions, at top, bottom and sides with required pvc / neoprene felt etc. aluminium section shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws al. tower bolt & al. handle & al. aldrop etc., all complete as per architectural drawings and the directions of engineer in charge. ( glazing and paneling to be paid for separately ) . 25 for fixed portion : polyester powder coating aluminium ( minimum thickness of powder coating 50 micron ) . 26 for shutters builtup standard tubular sections of openable doors, windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required ( lockes shall be paid for separately ) : polyester powder coating aluminium ( minimum thickness of powder coating 50 micron ) . 27 providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with pvs / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge. ( cost of aluminium snap beading shall be paid in basic item. ) : with float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg / sqm. ) . 28 providing and fixing expanded grill made of aluminium as per design and drawing having members section of size 7.5 mm × 6.0 mm and opening of size 102 mm × 99 mm to aluminium window / vent with required screws, y and h aluminium sec ( as per drawing ) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge : polyester powder coating aluminium ( minimum thickness of powder coating 50 micron ) . 29 providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. 30 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding : new work ( two or more coats ) including preparation of base with primer, putty, lippy etc. complete in all respect. 31 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work 32 providing and fixing external grade board solid core single / double leaf flush door shutters is: 2202 ( part ii ) 1996 marked using phenol formal dehyderesin in glue both sides with approved stainless steel fittings complete as per annexure a : 35 mm thick : commercial veneer both side 33 p & f 1st quality stain free double charge vitrified tiles on floor, skirting and steps etc. in different sizes ( thickness to be specified by manufacture ) with water absortion less than 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1 : 4 including grounting the joints with white cement and matching pigment etc. complete : size 600 mm × 600 mm. deduct for not using 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) bedding in laying of floor tiles. 34 add extra for fixing glazed / ceramic / vitrified floor tiles with cement based high polymer modified quick set tile adhesive ( water based ) conforming to is: 15477, using 5 kg. adhesive per sum of tile area, in average 3 mm thickness instead of cement mortar 35 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded with 15×3 mm lugs 10 cm long embedded in cement concrete blocks 15×10×10 cm of 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 36 providing and laying brick kharanja on roofs with cement mortar 1:4 ( 1 cement : 4 coarse sand ) mixed with 2% integral water proofing compound in square pattern : 75 mm to 100 mm thick average. 37 providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting, welding and fabrication with priming coat of red oxide : 38 providing & fixing fly proof wire gauze to windows, clerestory windows & doors with m.s. flat 15×3 mm and nuts & bolts complete. galvanised m.s. wire gauze with 0.63 mm dia wire and 1.4 mmaperture on both sides. 39 providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. 40 part c : renovartion of physics lab 41 removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandal / loi and all scaffolding. ( for colour changing only ) . 42 6 mm thick cement plaster to ceiling of mix 1:3 ( 1 cement : 3 fine sand ) . 43 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : with cement mortar 1 :4 ( 1 cement : 4 coarse sand ) . 44 providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. 45 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding : new work ( two or more coats ) including preparation of base with primer, putty, lippy etc. complete in all respect. 46 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work 47 providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting, welding and fabrication with priming coat of red oxide : 48 providing & fixing fly proof wire gauze to windows, clerestory windows & doors with m.s. flat 15×3 mm and nuts & bolts complete. galvanised m.s. wire gauze with 0.63 mm dia wire and 1.4 mmaperture on both sides. 49 providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel isi section 80×25 mm ×1.25 mm thick with 1.00 mm ms sheet to spot welded including holdfasts of 15×3 mm, ms oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of engineer in charge. 50 p & f 1st quality stain free double charge vitrified tiles on floor, skirting and steps etc. in different sizes ( thickness to be specified by manufacture ) with water absortion less than 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1 : 4 including grounting the joints with white cement and matching pigment etc. complete : size 600 mm × 600 mm. deduct for not using 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) bedding in laying of floor tiles. 51 add extra for fixing glazed / ceramic / vitrified floor tiles with cement based high polymer modified quick set tile adhesive ( water based ) conforming to is: 15477, using 5 kg. adhesive per sum of tile area, in average 3 mm thickness instead of cement mortar 52 p & f wvc wash basin ( ist quality is:2556 mark ) of approved make with c.i. brackets duly painted 1 no. 15 mm c.p. pillar cock ( is:8934 mark ) & 32 mm c.p. brass waste coupling of approved make 32 mm waste pipe complete including cutting & making good the wall : size 580 mm × 450 mm. 53 p & f g.i. pipes with g.i. fittings excluding union ( is : 1239 mark ) including trenching & refilling earth etc. : ( external work ) medium duty pipes : 54 25 mm dia nominal bore. 55 20 mm dia nominal bore. 56 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 10.0 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) .cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) . 57 p & f pillar cocks ( is : 8934 mark ) of superior quality and approved make : c.p. pillar cock, swan neck with casted spout, 15 mm nominal bore 58 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding : new work ( two or more coats ) including preparation of base with primer, putty, lippy etc. complete in all respect. 59 part d : renovartion of stage and tennis court 60 earth work in excavation by mechanical means ( hydraulic excavator ) / manual means in foundation trenches or drains ( not exceeding 1.5 m in width or 10 sum on plan ) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils. 61 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work upto plinth level. 1: 4: 8 ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size ) . 62 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 10.0 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) .cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) . 63 filling available excavated earth ( excluding rock ) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead upto 50 meter and with all lift. 64 kota stone slab flooring 25 mm thick over 20 mm ( average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand ) : for area of each slab from 2001 to 5000 sq. cm. add extra for combined flooring kota stone & marble flooring : for marble flooring area upto 20%. 65 extra for mirror polishing on terrazzo / kota stone work wherever required to give high gloss finish complete. 66 providing and fixing welded mesh / expanded metal mesh in frame work, flat iron beading 20×3 mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete ( excluding frame work ) of size : welded mesh 25 mm × 25 mm × 2.1 mm. 67 6 mm thick cement plaster to ceiling of mix 1:3 ( 1 cement : 3 fine sand ) . 68 providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting, welding and fabrication with priming coat of red oxide : 69 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 70 providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete. 71 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding : new work ( two or more coats ) including preparation of base with primer, putty, lippy etc. complete in all respect. 72 dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 73 part e : renovation and repair work of phe lab 74 dismantling stone slab / terrazzo chip flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 75 demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge : in cement mortar. 76 brick work with common burnt clay f.p.s. ( non modular ) bricks of class designation 10.0 in superstructure above plinth level upto floor five level in all shapes and sizes in : cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) .cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) . 77 removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandal / loi and all scaffolding. ( for colour changing only ) . 78 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish : 20mm thick. 79 6 mm thick cement plaster to ceiling of mix 1:3 ( 1 cement : 3 fine sand ) . 80 providing and fixing stainless steel a isi 304 ( 18 / 8 ) kitchen sink & is 13983 with c.i. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : kitchen sink with drain board stainless steel kitchen sink with drain board 510×1040 mm bowl depth 200 mm. 81 p & f wvc wash basin ( ist quality is:2556 mark ) of approved make with c.i. brackets duly painted 1 no. 15 mm c.p. pillar cock ( is:8934 mark ) & 32 mm c.p. brass waste coupling of approved make 32 mm waste pipe complete including cutting & making good the wall : size 580 mm × 450 mm. 82 p & f pillar cocks ( is : 8934 mark ) of superior quality and approved make : c.p. pillar cock, swan neck with casted spout, 15 mm nominal bore 83 p & f 1st quality stain free double charge vitrified tiles on floor, skirting and steps etc. in different sizes ( thickness to be specified by manufacture ) with water absortion less than 0.08% and conforming to is 15622 of approved make in all colour and shade, laid with 20 mm thick cm 1 : 4 including grounting the joints with white cement and matching pigment etc. complete : size 600 mm × 600 mm. deduct for not using 20 mm thick cement mortar 1:4 ( 1 cement : 4 coarse sand ) bedding in laying of floor tiles. 84 add extra for fixing glazed / ceramic / vitrified floor tiles with cement based high polymer modified quick set tile adhesive ( water based ) conforming to is: 15477, using 5 kg. adhesive per sum of tile area, in average 3 mm thickness instead of cement mortar 85 providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats, or black pipe with holdfast and fittings complete as per design and drawing including cutting, welding and fabrication with priming coat of red oxide : 86 painting with synthetic enamel paint of approved brand and manufacture to give an even shade : two or more coats on new work 87 supplying and fixing in walls machine cut and polished stone shelves, tands and in cm 1:3 with machine cut edges : sand or other approved stone 25 mm thick. 88 half brick masonry with common burnt clay f.p.s. ( non modular ) bricks of class designation 7.5 in foundation & plinth : cement mortar 1 : 6 ( 1 cement : 6 coarse sand ) . 89 providing and fixing granite stone slab mirror polished and machine edge cut in walls, pillars, steps, shelves, sills counters, floors etc. laid on 12 mm ( av. ) thick base of cement mortar 1:3 ( 1 cement : 3 coarse sand ) jointing with white cement mortar 1:2 ( 1white cement : 2 marble dust ) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. black / south : above 3601 cm2 slabs 90 extra for providing edge moulding to 15 18 mm thick marble / granite stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge granite work. 91 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead : with cement mortar 1 :4 ( 1 cement : 4 coarse sand ) ....

Medical Health And Family Welfare - Rajasthan

28639367 civil work for ogp at chc siswali distt. baran earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 2 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor three level excluding the cost of centering and shuttering.m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 3 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings,strap beam, raft , bases of columns etc. 4 providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering and reinforcement including curing, compaction finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints and admixtures in recommended proportions as per is : 9103 to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of engineer in charge. m 20 grade reinforced cement concrete. all work from plinth level up to floor three level.walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 5 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. hot rolled deformed bars (is : 1139). 6 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 7 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 8 filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 9 random rubble dry stone kharanja under floor. 10 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 11 structural steel work in single section fixed with or without connecting plate including cutting, hoisting (height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.add extra if i/rail section is used 12 steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.hot finished welded type tubes. 13 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 14 supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 15 providing and fixing square bars or other flat welded to window, ventilatiors etc. 16 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 17 providing corrugated g.i. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.1.60 mm thick with zinc coating not less than 275 gm/m2 18 providing and fixing m.s. sheetsingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paintm.s. sheet 20 s.w.g. 19 supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. m.s. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade no. 2 and m.s. top cover 1.25mm thick for rolling shutters as per design & is 6248 1979. (clear openable area to be measured for payment). 20 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 40 mm thick slab. 21 providing& fixing ball bearing for rolling shutters 22 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m15 grade nominal mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 23 grading roof for water proofing treatment withwater proffing compoundcement mortar 1:3 (1 cement : 3 coarse sand) 24 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 25 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 26 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 27 providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.welded mesh 25 mmx 25 mm x 2.1 mm ...

Medical Health And Family Welfare - Rajasthan

28639211 civil work for ogp at dh baran distt. baran civil work for ogp at dh baran distt. baran earth work in excavation by mechanical means (hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils 2 providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor three level excluding the cost of centering and shuttering.m10 grade nominal mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 3 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation, footings,strap beam, raft , bases of columns etc. 4 providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centering, shuttering and reinforcement including curing, compaction finishing with rendering in cement sand mortar 1 : 3 (1 cement : 3 coarse sand) and making good the joints and admixtures in recommended proportions as per is : 9103 to accelerate, retard setting of concrete improve workability without impairing strength and durability as per direction of engineer in charge. m 20 grade reinforced cement concrete. all work from plinth level up to floor three level.walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc.m20 grade nominal mix 5 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. hot rolled deformed bars (is : 1139). 6 flyash flyash brick work with flyash flyash bricks of class designation 75 in superstructure above plinth level upto floor three level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 7 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 8 filling in plinth with locally available river shingle under floors including watering ramming consolidating and dressing complete including cost of shingle sand. 9 random rubble dry stone kharanja under floor. 10 filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 11 structural steel work in single section fixed with or without connecting plate including cutting, hoisting (height upto 10 m), fixing in position and applying a priming coat of approved steel primer all complete.add extra if i/rail section is used 12 steel work in built up tubular trusses including cutting, hoisting ( height upto 10 m)fixing in position and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete.hot finished welded type tubes. 13 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (is 1038 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required :partly fixed and partly openable [ fixed area not to exceed 33%] 14 supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 15 providing and fixing square bars or other flat welded to window, ventilatiors etc. 16 providing and fixing t iron frames for doors, windows and ventilators of mild steel tee sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. 17 providing corrugated g.i. sheet roofing including vertical / curved surface fixed with polymer coated j or l hooks, bolts and nuts 8 mm diameter with bitumen and g.i. limpet washers or with g.i. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.1.60 mm thick with zinc coating not less than 275 gm/m2 18 providing and fixing m.s. sheetsingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paintm.s. sheet 20 s.w.g. 19 supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. m.s. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade no. 2 and m.s. top cover 1.25mm thick for rolling shutters as per design & is 6248 1979. (clear openable area to be measured for payment). 20 polished blue kota stone flooring skirting, laid over 20 mm thick base of c.m. 1 : 4 and jointed with grey cement slurry to match the shade of the slab including rubbing and polishing complete :for area of each slab from 901 to 2000 sq.cm : 40 mm thick slab. 21 providing& fixing ball bearing for rolling shutters 22 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m15 grade nominal mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 23 grading roof for water proofing treatment withwater proffing compoundcement mortar 1:3 (1 cement : 3 coarse sand) 24 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick. 25 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : two or more coats on new work including preparation of base with primer, putty, lippy complete in all respect. 26 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 27 providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.welded mesh 25 mmx 25 mm x 2.1 mm ...

Medical Health And Family Welfare - Rajasthan

28638001 civil work of ogp room at janana hospital, distt. alwar 2 earth work in excavation by mechanical means (hydraulic excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. all kinds of soils. 3 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. 4 random rubble stone masonry for with hard stone in foundation and plinth in cement sand mortar above 30 cm thick wall in:cement mortar 1:6 ( 1 cement : 6 sand). 5 providing and laying in position specified grade ofcement concrete forall rcc structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. m20 grade nominal mix / design mix 6 providing and laying in position specified grade ofcement concrete for rcc structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.m20 grade nominal mix / design mix 7 centering and shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 8 centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 9 providing and fabricating reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. thermo mechanically treated bars (conforming of relevent is code) 10 random rubble dry stone kharanja under floor. 11 brick work with f.p.s. bricks of class designation 75 in superstructure above plinth level upto floor v level in all shapes and sizes in :cement mortar 1 : 6 (1 cement : 6 coarse sand) 12 plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick 13 providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering all work up to plinth level. m20 grade nominal mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20 mm nominal size). 14 finishing walls with acrylic smooth exterior paint of required shade including all scaffolding. new work (two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 15 wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 16 painting with synthetic enamel paint of approved brand and manufacture togive an even shade : two or more coats on new work 17 providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : windows side hung /ventilators top or centre hung (openable) 18 supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. 19 providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 20 providing and fixing welded mesh/expanded metal mesh in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. complete (excluding frame work) of size.welded mesh 25 mmx 25 mm x 2.1 mm 21 providing & fixing uv stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated ‘j’ or ‘l’ hooks, bolts & nuts 8mm dia. g.i plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. the sheets shall be manufactured out of 2400 tex panel rovigs incorporating minimum 0.3% ultra voilet stabiliser in resin system under approximately 2400 psi and hot cured. they shall be of uniform pigmentation and thickness without air pockets and shall confoim to is 10192 and is 12866.the sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified.3.0mm thick (wt. 5.0 kg./mtr. sq.) 22 structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete: 23 providing and fixing m.s. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of engg. incharge but excluding cost of chowkhats: including two coats of anit corrosive red oxide primer paint. extra for double leaf shutters. 24 part b : electrical work 25 wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade (is:694) ofapproved make in surface / recessed isi marked medium duty pvc conduit & its accessories, round tiles,hot dipped galvanized modular box with earth terminal, 6 a modular switch,modular plate with grid plate,screws,making connections, testing etc. as required.gr 1 26 short point (up to 3 mtr.) 27 medium point (up to 6 mtr.) 28 long point(up to 10 mtr.) 29 wiring of 3 pin 5 amp. light plug point with 1.5 sq. mm nominal sizefr pvc insulated unsheathed flexible copper conductor 1.1 kv gradeand 1.5 sq. mm nominal size fr pvc insulated unsheathed flexible copper earth conductor 1.1 kv grade(is:694) of approved makein surface / recessed isi marked medium duty pvc conduit & its accessories, hot dipped galvanized m.s modular box of 20 swg with earth terminal, 6 a modularswitch, 6 a modular socket, modular plate with grid plate, screws, making connections, testing etc. as required.gr 1 30 on board 31 supplying and fixing of power plug point modular accessories on hot dipped galvanized modular on surface or in recessed with suitable size of grid plate with cover plate including cost ofmodular 16 amp. switch and socket outlet, making connection , testing , etc. as required.gr 1 32 supplying and drawing fr pvc insulated & unsheathed flexible copper conductor isi marked (is:694) of 1.1 kv grade and approved make in existingsurface or recessed conduit/casing capping including making connections etc. as required.g1 33 2 x 2.5 sq. mm. + 1x1.5sqmm 34 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 35 p&f recessed/ surface mounting heavy duty horizontal type sheet steel distribution board phophatised/ powder painted complete with copper bus bar, shorting link , neutral link, earth link and din bar, conforming to is13032 & is8623 including making internal dbterminations with copper lugs , testing etc. as required.g1 36 double door (single phase) 37 12 way 38 p&f 240/415 v mcb of breaking capacity not less than 10 ka (b/ c/ d tripping characteristic) isi marked is 8828(1996)]/ conforming to iec 60898 in existing board/sheets including making connections with lugs, testing etc. as required.group 1 39 single pole mcb 40 6 a to 32 a rating 41 double pole mcb 42 40 63 a 43 s&f following sizes (dia.) of isi marked medium duty pvc conduit along with accessories in surface / recessed using saddles, clamps, fastener as required includingcutting the wall and making good the same as required.group 1 44 25 mm 45 p & f phenolic laminated sheet 2.0 mm thick of size 75 mm dia. including screws, cup washer as required. 46 p & f following modular accessories made out of unbreakable and fire retardant poly carbonate with silver contacts including making connections testing etc. as required 47 5 step fan regulator 2 modulegr 1 48 p & f 18 swgm.s. recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . 49 p&f of heavy duty capacitor start 900/1400 rpm single phase isi marked exhaustfan,is:2312 marked in existing opening including making connections testing etc. as required.group 1 50 450 mm sweep(900/1400 rpm) 51 p & f of gravity louver shutter of superior quality made out of frame of18 swg m.s. sheet & louvers made from 24 swg ms sheetwith enamel paint including cost of nuts, bolts, etc as reqd. 52 up to 380 mm size 53 p & f of ip 20 led tube light 20 watt with external batten made from crca sheet steel suitable to replace t b/t 12 tube light, integral driver, 2000 luman + 5olo tolerarrce system luman efficiacy of 100 lm/ watt minimum expected life time of 25000 burning hours, cct 5700 i( ansi, cri 80, driver efficiency >850/o, life expectancy of driver rnin 30000 hrs. pf 0,95 at full load/ 230 volt ac.gr 1 54 p & f double ball bearing capacitor start, aluminium body & blade ceilingfanwith down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. 1200 mm sweep gr 1 55 p/laying p.v.c. insulated & p.v.c. sheathed cable of 1.1 kv grade with aluminium conductor of is:1554 p i of group2of approved makein ground as per is:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand,iind class bricks covering, refilling earth,compaction of earth, making necessary connection, testing etc. as required of size.group 1 (armoured) in existing rcc/hume/stoneware pipe 56 70.0 sq,mm 57 3 core 58 s & laying following size earth wire/stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 59 8 swg copper wire 60 25 mm dia. 61 supplying and drawing pvc/ polythene insulated and pvc sheathed unarmoured/ armoured telephone cable with 0.5 mm dia. tinned /annealed copper conductor taped &confirming to itd specification s/ws 113c ofapproved make in existingsurface or recessed conduit/casing capping. 62 unarmoured telephone cable in existingsurface or recessed conduit/casing capping. 63 2 pair 64 p & f isi markedflush type single line telephone jack including making connection testing etc. as required. 65 supply , drawing and testing of 4 pair, 24 awg utp cat 6 cable as per latest ammendments of tia /eia 568 b.2 1 specifications in existing ms/pvc conduits including making connections to information outlets and patch panels with ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing required 66 supply and installation of information outlets made of high impact plastic body abs fr grade with spring loaded collapsible shutters in jack recess, suitable for cat 6 application complying to latest ammendments eia/ tia 568 b.2 1 specifications in existing modular /ms boxes along with necessory connections as required 67 supply & fixing of faceplate for flush / surfacemount information outlets single aperture with screw hole covers & icon tree size 86mmx86mm 68 single aperture ...

Public Works Department - Rajasthan

28376942 supply of civil, sanitary, and painting material for sub division ii new delhi: 1 supply of glue kg 2 2 brass tower bolt ( barrel type ) 250xl0 mm each 5 3 brasstower bolt ( barrel type ) 200x10 mm each 5 4 brass tower bolt ( barrel type ) 150xl0 mm each 5 5 brass handles 125 mm with plate 175x32 mm each 5 6 brass door latch 300x16x5 mmweighing not less than 0.380 kg each 2 7 brass door latch 250x16x5 mm weighing not less than 0.350 kg each 2 8 chromium plated brass handles 125 mm with plate 175 x32 mm each 2 9 oxidised mild steel sliding door bolt 300xl6 mm each 2 10 supply of hydraulic open door closer of godrej make or equivalent and as approved by engineer each 5 in charge 11 supply of wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm of sqm 20.00 width 2.5 as approved by engineer in charge 12 stainless steel butt hinges 75x4 7x 1.8 mm is : 12817 marked 10 5.00 nos 1 / 4 s. description unit quantity rate to be quoted amount no. t 2 3 4 5 13 stainless steel butt hinges 100x58x1.9 mm is: 12817 marked 10 5.00 nos 14 m.s. tower bolt ( 6 ) nos 5.00 part a total rs. part b ( painting items ) i supply of plaster of paris as approved by engineer in charge kg 100.00 2 supply of jk wall / birla putty as approved by engineer in charge kg 100.00 3 supply of premium acrylic exterior paint as approved by engineer in charge litre 20.00 4 supply of synthetic enamel paint in black or chocolate shade as approved by engineer in charge litre 5.00 5 supply of synthetic enamel paint in all shades except black or chocolate shade as approved by litre 5.00 engineer in charge 6 supply of plastic emulsion paint as approved by engineer in charge litre 5.00 7 supply of oil bound washable distemper / acrylic distemper as approved by engineer in charge kg 50.00 8 supply of white cement as approved by engineer in charge kg 20.00 9 water proofing cement paint kg 100.00 10 turpentine oil ltr 20.00 11 spirit ltr 5 2 / 4 s. description unit quantity rate to be quoted amount no. 1 2 3 4 5 12 red oxide zinc chromate primer ltr 10 13 linseed oil ( double boiled ) ltr 10 part b total rs. part c ( civil items ) 1 supply of portland cement ( opc 43 grade ) 50 kg bag bags 5.00 2 supply of coarse sand ( zone iii ) as approved by engineer incharge. cft 50.00 3 supply of fine sand ( zone iv ) as approved by engineer incharge. cft 50.00 part c total rs. part d ( sanitary items ) 1 supply of 15 mm ptmt bib cock of prayag make or equivalent as approved by engineer in each 5 charge 2 supply of 15 mm ptmt angle cock of prayag make or equivalent as approved by engineer in each 2 charge 3 supply of2 in i faucat ofprayag make. ( i mtr. braided tude ) with hook each 2 4 flexible ( coil shaped ) pvc waste pipe for sink and wash basin 32mm dia with length not less each 5 than 700 mm i / c pvc waste fittings 5 supply of h.p. or l.p. ball valve with polythene floats: 15 mm dia as approved by engineer in each 2 charge 6 supply of h.p. or l.p. ball valve with polythene floats: 25 mm dia as approved by engineer in each 2 charge 7 8 mm dia c.p. brass / s.s. jet with flexible tube upto 1 metre long with s.s. tringular plate for each 2 eureopean type w.c. 3 / 4 s. description unit quantity rate to be quoted amount no. r 2 3 4 5 8 supply of unplasticised p.v.c. connection pipe with brass union 45 cm long 15 mm bore. as each 6 approved by engineer in charge 9 ptmt ball cock 15mm of prayag make or equivalent complete with epoxy coated aluminium each 10 rod & h.d. ball 10 ptmt ball cock 25mm of prayag make or equivalent complete with epoxy coated aluminium each 2 rod & h.d. ball 11 ptmt ball cock 40mm of prayag make or equivalent complete with epoxy coated aluminium each 4 rod & h.d. ball 12 ptmt soap dishlholder 138xl02x75 mm each 5 13 c.p. brass centre hole basin mixer with cast spout each 1 14 stainless steel kitchen sink with drain board 510 x 1040 mm bowl depth 250 mm each 1 15 ptmt liquid soap container of 400 ml capacity each 2 16 vitreous china orrisa type w.c. pan of size 580 mm each 2 17 floor mounted white vitrous china double trap syphonic wc with 10 litre cistern and all fittings each 1...