Power Grid Corporation Of India Limited - Rajasthan

34896131 bids are invited for as per sample boq attached earthwire accessory , as per sample boq attached earthwire accessory , as per sample boq attached earthwire accessory , as per sample boq attached earthwire accessory , as per sample boq attached earthwire accessory , as per sample boq attached earthwire accessory , as per sample boq attached earthwire accessory , as per sample boq attached earthwire accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory , as per sample boq attached conductor accessory total quantity : 1216...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32465995 supply erection installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of dausa lot i circle under the domain of jaipur discom against supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32465992 supply erection installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of dholpur lot i circle under the domain of jaipur discom against tn 523. supply erection under the domain of jaipur discom against tn 523. supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32465910 supply erection installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of baran lot i circle under the domain of jaipur discom against tn 523. supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32072400 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of jaipur district circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064846 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of bharatpur circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064840 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of alwar circle lot iii under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064838 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of jhalawar circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064834 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of bundi circle lot ii under the domain of jaipur discom against tn 52 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064830 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of sawai madhopur circle lot i under the domain of jaipur discom against tn supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064827 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of sawai madhopur circle lot ii under the domain of jaipur discom supply of material ( all material shall be supplied as per specification enclosed with the bidding documents ) : 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s / c lattice structure ( 36 ungalvanised with 1 nos 33 kv cross arm ( channel ) with required nuts and bolts. 4 11 / 0.433 kv, 40 kva aluminium wound bis level 2 completely self protected ( csp ) distribution transformers with provisio of lt bushing box 5 25 kva, 11 / 0.433 kv, aluminium woundbis level 2 ( star 1 ) completely self protected ( csp ) distribution transformers with provision of lt bushing box. 6 16 kva, 11 / 0.433 kv, aluminium woundbis level 2 ( star 1 ) completely self protected ( csp ) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7 / 10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h / w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts ( assorted size ) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle ) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11 / 0.4 kv s / s structure set for 3 ph 40 / 25 / 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details ( 1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length ) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable ( armoured ) 23 m.s. angles 75 x 75 x 6 mm ( for guarding ) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box ( free issue ) . 25 m.s. channel 75 x 40 x 6 mm ( for extension bracket ) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches / plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation / pit. 35 ( a ) height of poles / r.s.joist / m.s. rail / size of pit 36 9 mtr / 1.2mx0.6mx1.50 m deep 37 ( b ) lattice tower / size of pit 38 11.4 / 10.8 mtr / 1.5mx1.5m x1.80 m deep 39 ( c ) stay set / depth of pit 40 6x5 / 8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation / pit. 42 ( a ) height of poles / r.s.joist / m.s. rail / size of pit 43 9 mtr / 1.2mx0.6mx1.50 m deep 44 ( b ) lattice tower / size of pit 45 11.4 / 10.8 mtr / 1.5mx1.5m x1.80 m deep 46 ( c ) stay set / depth of pit 47 6x5 / 8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c ) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof ( 50 km ) 53 safe carriage of steel ( fabricated and unfabricated ) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store / at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. ( 50 km ) 57 safe carriage of insulator, hardware, cable etc.including loading / unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. ( 50 km ) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading / unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof. ( 50 km ) 65 safe carriage of 11 / .4 kv 3 phase distribution transformer including loading / unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. ( 50 km ) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. ( 50 km ) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets, cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long ( 200kg. ) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long ( 200kg. ) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set / stay wire 82 6x5 / 8 with 7 / 10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement, river sand and 12 mm to 20 mm graded blast crusher broken in pit / foundation according to the size / type of supports / stay set including compaction / curing for 21days in steel plates shuttering / farmer base. ( 1.2x1.2 x2.1 m ) / tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s / t&c type disc insulator of 11kv lines ( each unit consiting of 1nos.disc.& 1set of h / w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set ( set of 3 nos ) on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11 / 0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs / clamping earth connections of body and neutral of transformer with wire / strip ( as already provided with earthing ) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports / structure 100 fixing of pg clamp of weasel / rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing, stringing, tensioning and clamping of g.i.earthwire continuosly on single / double pole by using earth clamps / nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 ( b ) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing / p&t crossing / railway track crossing ( for one span only ) with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire / gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates. ( in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom ) 109 earthing of 11 / 0.4 kv distribution transformer / sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9 / 16 dia. at flattened top and tightening of m.s. flat 50x6mm ( having 3 hole 2ends and 1mm middle ) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box ( complete unit ) at the premises of existing / new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical / plumb line, anchor fasteners are to be supplied / provided by the contractor including safe carriage from s / d store to consumers site and depositing removed meter and meter box if any in s / d store ) . 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 ( pt i ) ( latest amended ) overhead service line from pole to meter terminals for release of new lt connections / replacement of damaged / obsolete service line ( except agriculture one ) . the cable must be fixed on wall with clamps / hooks properly at a interval of one meter. 113 4 core 16 / 25 sq. mm 114 fixing of 3 phase lt shunt capacitor ( 3 / 6 / 9 / 12kvar ) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor ( the lt shunt capacitor shall be supplied by nigam ) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32064822 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of tonk circle lot i under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32062173 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of bundi circle lot i under the domain of jaipur discom against tn 523 3supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32050006 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of alwar circle lot ii under the domain of jaipur discom against tn 523 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of alwar circle lot ii under the domain of jaipur discom against tn 523 supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Jaipur Vidyut Vitran Nigam Limited - Rajasthan

32049979 supply, erection, installation and commissioning of material equipment for the work of release of ag connection in fy 2022 23 on turnkey basis in respect of alwar circle lot i under the domain of jaipur discom against tn 523supply of material (all material shall be supplied as per specification enclosed with the bidding documents): 2 9 mtr. long pcc poles of 200 kg working load with factor of safty 2.5. 3 33 kv s/c lattice structure (36 ungalvanised with 1 nos 33 kv cross arm(channel) with required nuts and bolts. 4 11/0.433 kv, 40 kva aluminium wound bis level 2 completely self protected (csp) distribution transformers with provisio of lt bushing box 5 25 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 6 16 kva, 11/0.433 kv, aluminium woundbis level 2 (star 1) completely self protected (csp) distribution transformers with provision of lt bushing box. 7 galvanised steel stay set 16x1800 mm 8 11 kv stay insulator 9 galvanised steel stay wire 7/10 swg 10 stay set clamps suitable for 9 mtr. long pcc poles 11 h/w for disc insulators 45kn t&c type 12 disc insulators 45kn t&c type 13 m.s. nuts & bolts (assorted size) 14 acsr rabbit conductor 15 11 kv v cross arm with top hamper and clamps ( angle) 16 galvanized m.s. froged 11 kv pin 17 11 kv pin insulator 18 11/0.4 kv s/s structure set for 3 ph 40/25/ 16 kva transformer on double pole 19 horn gap fuse set with post insulator 11 kv 20 ms rod type earthing set with wire & clamp with following details(1 no. galvanised m.s. rod 20 mm dia electrodes having3 meter length, 2 nos. galvanised earthing clamp of m.s.flat of size 50x6 mm 220 mm length. one welded with earthelectrode and loose to be bolted; 2 nos. galvanised bolts, nuts and spring washers and g.i.wire size 8 swg of 15 meter length) 21 1.4 mtr channel 100x50x6 mm bracket with clamp 22 4c x 16 sq. mm. lt pvc insulated pvc sheathed cable (armoured) 23 m.s. angles 75 x 75 x 6 mm (for guarding) 24 three phase four wire whole current meter of rating 10 60 a having backlit lcd display with meter box (free issue). 25 m.s. channel 75 x 40 x 6 mm (for extension bracket) 26 lt shunt capacotors 3 kvar 27 lt shunt capacotors 6 kvar 28 danger plate 29 11 kv line dp set 30 p.g. clamps for rabbit 31 g.s. earth wire 8 swg 32 erection of material: 33 trimming of tree branches/plants and preparing route approchases for proposed line. 34 excavation of pit in hard soil to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 35 (a) height of poles/r.s.joist/m.s. rail /size of pit 36 9 mtr/ 1.2mx0.6mx1.50 m deep 37 (b) lattice tower /size of pit 38 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 39 (c)stay set/depth of pit 40 6x5/8 0.75x0.5x1.35m 41 excavation of pit in ordinary rock which does not require blasting to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit. 42 (a) height of poles/r.s.joist/m.s. rail /size of pit 43 9 mtr/ 1.2mx0.6mx1.50 m deep 44 (b) lattice tower /size of pit 45 11.4/10.8 mtr/ 1.5mx1.5m x1.80 m deep 46 (c)stay set/depth of pit 47 6x5/8 0.75x0.5x1.35m 48 safe carriage of pcc poles including loading / un loading 49 c) 9 mtr.long 200 kg. pcc pole 50 within10 kms. 51 above 10 km. & upto 30 km. add foreach km. or part thereof 52 above 30 km. add for each km. or part thereof (50 km) 53 safe carriage of steel( fabricated and unfabricated) i.e.m.s. rails, r.s.joists, m.s.channels, m.s.angles, m.s.flat, g.i.stay sets, g.i. stay wire, g.i.wire nut & bolts etc. and acsr conductor including loading and unloading and stacking in nigam store /at work site 54 within10 kms. 55 above 10 kms. & upto 30 kms. add for each km.or part thereof. 56 above 30 kms. add for each kms. or partthereof. (50 km) 57 safe carriage of insulator, hardware, cable etc.including loading/unloading and stacking in nigam.stores etc. 58 within10 kms. 59 above 10 kms. & upto 30 kms. add for each km.or part thereof. 60 above 30 kms. add for each kms.or part thereof. (50 km) 61 safe carriage of fabricated lattice towers structures and sub station structures type ab, ab beams, isolators structures etc. including loading/unloading and stacking in the nigam. stores / at work site. 62 within10 kms. 63 above 10 kms. & upto 30 kms. add for each km.or part thereof. 64 above 30 kms. add for each kms.or part thereof.(50 km) 65 safe carriage of 11/.4 kv 3 phase distribution transformer including loading/unloading and stacking in nigam.stores etc. 66 10 &16 kva 67 within10 kms. 68 above 10 kms. & upto 30 kms. add for each km.or part thereof. 69 above 30 kms. add for each kms.or part thereof. (50 km) 70 25 & 40 kva 71 within10 kms. 72 above 10 kms. & upto 30 kms. add for each km.or part thereof. 73 above 30 kms. add for each kms.or part thereof. (50 km) 74 erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. the support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item no. 5.6 the remaining portion of the pit will be back filled with soil. the nuts & bolts will be provided by the contractor as per nigams specification for which payment will be made at the prevailing store issue rates. the cost muffing and grouting will be paid extra. 75 lattice structure 76 erection of pcc poles in excavated pit with fixing of brackets,cross arms & top hampers as required in alignment after checking the same with plumb line. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractor as per nigams specification for which the payment will be made at the prevailing discom store issue rates. 77 in rural area 78 pcc poles 9 mtr. long(200kg.) 79 erection & assembly of 2 pole structures ofof steel supports or of pcc poles in excavated pit in alignment afterchecking the same with plumb line. including fixing of top bracing of m.s. channels with pilot plates and clamps. the support is to be back filled with soil with proper ramming. the nuts & bolts are to be provided by the contractoras per nigams specfication for which the payment will be made at the prevailing discom store issue rates. 80 pcc poles 9 mtr. long(200kg.) 81 erection & fixing of g.i.stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.the work includes fixing of stay clamps. stay insulator with stay wire at both ends with proper tension.size of stay set/stay wire 82 6x5/8 with 7/10 swg stay wire 83 providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.(1.2x1.2 x2.1 m)/tower 84 fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub station. 85 fixing of guarding bracket arms with clamp on erected support as per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 86 11 kv line 87 fixing of earth wire clamp on erected supportas per design. the nuts &bolts will be supplied by the contractor as per nigams specification for which payment will be made as per prevailing discom store issue rates. 88 fixing and assembly of disc.point channel pair with pilot plates&clamps on erected double pole structure as per design. the nuts &bolts are to be provided by the contractor as per nigams specification for which payment will be made as perprevailing discom store issue rates. 89 11 kv line 90 fixing and assembly of disc. point channel pair with pilot plates & clamps on erected single pole structure as per design. the nuts & bolts are to be provided by the contractor as per nigams specification for which payment will be made as per prevailingdiscom store issue rates. 91 11 kv line 92 fixing of 11kv b&s/t&c type disc insulator of 11kv lines(each unit consiting of 1nos.disc.& 1set of h/ w ) on terminal point including fixing of hardware and strips. 93 fixing of 11 kv pininsulator with pins. 94 ssembly and installation of horn gap fuse set (set of 3 nos)on erected structure as per design, complete in all respectwith post insulator includingjumperingonbothendsforconnection with the system. the nuts & bolts will be supplied by the contractorfor which payment will be made as per prevailing discom store issue rates. 95 11kv horn gap fuse set. 96 installation testing as per nigams norm & commissioning of11/0.4 kv distribution transformer on erected supports including fixing of base channels as per requirement jumpering on hv&lv side, crimping of lugs/clamping earth connections of body and neutral of transformer with wire/strip (as already provided with earthing) complete in all respect. the pg clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing discom store issue rates. 97 10 & 16 kva 98 25 & 40 kva 99 fixing of danger plates on supports/structure 100 fixing of pg clamp of weasel /rabbit conductor 101 laying, jointing , stringingtensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire/p.g. clamps aluminium jointing sleeves will be used for jointing the conductor. the line must stand at proper voltage on charging. the contractor will be provide p.g. clamps for which payment will be made as per prevailing discom store issue rates. 102 acsr rabbit 103 laying, jointing,stringing,tensioning and clamping of g.i.earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.the nuts and bolts will be supplied by thecontractor for which payment will be made as per prevailing discom store issue rates. 104 (b) in rural area 105 g.i.earth wire 8 swg 106 drawing & strining of g.i 4 wire over the guarding brackets for guarding of road crossing /p&t crossing/railway track crossing (for one span only)with cross g.i wire laces at an intraval of two meter each or required as per location using eye bolt nuts. 107 8 swg with laces of 10 swg 108 earthing of line for all type of supports as per rec construction standards using stay wire/gi wire with one pcs of m.s. rod 20mm dia each 3 meter long and driving into earth by mechanical means ms rod, ms flat & stay wire will be supplied by the contractor. ifmaterial is supplied by the contractor the payment will be made as per prevailing discom store issue rates.(in case of pcc poles earthing mustbe connected with earthwire already available on pcc pole at bottom) 109 earthing of 11/0.4 kv distribution transformer /sub station with 3 pieces of m.s. rod 20 mm dia each 3 meter long and drivingthem in to earth by mechanical means at a distance as per approved design & drawing & specification. the work includes flattening of top ends of m.s. rod drilling a hole of 9/16 dia. at flattened top and tightening of m.s. flat 50x6mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with m.s. rod. top end hole. the flat will also be welded with m.s. rod. the end will be connected to equipments as under as under in sequence. 110 fixing of three phase meter cummeter box(complete unit)at the premises of existing/new consumerswith 4 nos anchor fastners with rust proof size m 6x50 mm on the wall as per the positionof holes already provided on the meter box. the meter box must be housed perfectly vertical/plumb line,anchor fasteners are to be supplied/provided by the contractor including safe carriage from s/d store to consumers site and depositing removed meter and meter box if any in s/d store). 111 in rural area 112 laying of 1100 volt heavy duty armoured xlpe cable of aluminum coudctor of following size conforming to is: 7098 (pt i) (latest amended) overhead service line from pole to meter terminals for release of new lt connections/replacement of damaged/obsolete service line (except agriculture one). the cable must be fixed on wall with clamps /hooks properly at a interval of one meter. 113 4 core 16/25 sq. mm 114 fixing of 3 phase lt shunt capacitor (3/6/9/12kvar) near starterof motor for agriculature consumers to be fixed with ms clamp of shape of size 2x10mm having two nos.holes for fixing of lt capacitors besides starter of consumer with the help of two no.machine screw. the starter shall be connected using pvc sheathed single core of 4 sq.mm ai. cable conforming to relevant is. the wire shall be cut in three pieces which shall be used for extending existing wire whith making proper joint and joint shall be taped with ms compoundpvc tape roll. the ends of wire shall be properly crimped with lugsthimble etc.all material shall be supplied by the contractor except lt shunt capacitor (the lt shunt capacitor shall be supplied by nigam) ...

Prime Ministers Office - Rajasthan

30144656 bids are invited for vrf part a: vrf equipments:sl.no.1.1: 8 hp outdoor unit. the outdoor unit shall meet minimum cooling requirement of 7 tr ( 21000 k cal / hr. ) makes: voltas / blue star / carrier / carrier midea / o general / mitsubishi / daikin / eta gree / toshiba / hitachi / trane , outdoor part a of sl.no.2.1:8 h.p. outdoor unit , min part a of sl.no.3.1:minimum 2.0 tr cassettee type units , tr part a of sl.no.3.2: minimum 1.5 tr cassettee type units , cordless part a of sl.no.3.3: supply of cordless remote controls with lcd display for indoor units. , panel part a of sl.no.3.4:supply and fixing of decorative panels for round flow cassettee type indoor units. , joints part a of sl.no.4: supply and laying of suitable refnet joints with suitable insulation to take care of connectivity and circuiting as detailed above and as per tender drawing. , ceiling part a of sl.no.5.1: vrf ceiling suspended cassettee indoor units. , wiring part a of sl.no.6: supply and laying of suitable size of control / communication wiring ofcopper cable through pvc conduit . scope of work includes supply and fixing of pvc conduit with clamps etc. , thick part a of sl.no.7.1: 28.6 mm od ( insulation = 19mm thick ) , insulation part a of sl.no.7.2: 22.2 mm od ( insulation = 13mm thick ) , clamps part a of sl.no.7.3: 19.1 mm od ( insulation = 13mm thick ) , supports part a of sl.no.7.4: 15.9 mm od ( insulation = 13mm thick ) , bends part a of sl.no.7.5: 12.7 mm od ( insulation = 13mm thick ) , pipes part a of sl.no.7.6: 9.5 mm od ( insulation = 13mm thick ) , cable part a of sl.no.7.7: 6.4 mm od ( insulation = 13mm thick ) , tray part a of sl.no.8: supply, installation of gi tray with support for covering of exposed refrigerant pipe. makes: slottco / profab engineer / hi reach / mm enterprises , gi part a of sl.no.9.1: 32 mm dia , utrap part a of sl.no.9.2: 25 mm dia , drain part a of sl.no.10:supply and installation of press fit casing capping / pvc trunking of size 100mm * 50mm along the exposed drain pipeline in the recess / surface as required and as directed by nrsc. , powre part a of sl.no.11.1:pvc insulated 3c x 1.5 sqmm power cable ( for vrf indoor units ) , installation part a of sl.no.11.2:xlpe insulated 4c x 6 sqmm power cable ( for vrf outdoor units ) , core part a of sl.no.12: minor civil works like foundations / pedestals foroutdoor units and core cutting / cutting away, making and finishing good of openings in walls / ceiling etc.: for passage of pipes, ducts, cables, etc. complete as required. , split part b: tower split ac:sl.no.1.1:tower split ac units with minimum 2 tr nominal capacity.makes:voltas / blue star / carrier midea / daikin / hitachi / panasonic / mitsubishi / toshiba / trane / o general / lloyd , ac part b of sl.no.2.1:suction copper pipe line as per manufacturer recommendation. , liquid part bof sl.no.2.2:liquid copper pipe line as per manufacturer recommendation . , condensate part b of sl.no.3:supply and erection of condensate drain pipe made out of 25mm ( 10 kg / cm2 ) dia cpvc pipe, water u trap, pipe supports, clamps including nitrile rubber insulation. makes: astral / supreme , rubber part b of sl.no.4:supply and installation of 75 mm durable pvc pipe with elbows, couplings / reducers as an enclosure for refrigerant copper pipes to protect against radiation, rain, wind and other external factors as required and as directed by nrsc. , angles part b of sl.no.5:supply and installation of ms angles fabrication and all necessary clamps etc., for mounting of ac outdoor units, plenum, ductsas and when required as directed by nrsc etc. , powder part b of sl.no.6:supply and installation of suitable height and thickness of powder coated floor mounted stands for ac indoor units , earthwire part b of sl.no.7.1:suitable size of power cable as per manufacturer recommendation , cement part b of sl.no.7.2 :suitable size of control cable as per manufacturer recommendation , runs part b of sl.no.7.3 :g.i. earth wire of two runs of size 8 swg , conductor part b of sl.no.8:supply and installation of covered type gi tray.makes: slottco / profab engineer / hi reach / mm enterprises , pedestal part b of sl.no.9:minor civil works like making pcc pedestal and core cuttingfor good of openings, plastering, finishing with white cement in walls / ceiling etc. for passage of refrigerant pipes, ducts along with repairof wooden wall panelling complete as required as directed by nrsc at site. total quantity : 1...

Rajasthan Rajya Vidhyut Prasaran Nigam Limited - Rajasthan

23641182 uprating of 132kv s/c jhunjhunu bissau line from 132 kv gss jhunjhunu to 132 kv malsisar line crossing uprating of 132kv s/c jhunjhunu bissau line from 132 kv gss jhunjhunu to 132 kv malsisar line crossing ( with dismantling of existing 132 kv h pole line ) , detail survey as per tentative route of line which includes: , pegging of line route , providing of survey pillar at an interval of 3 4 km in the line route with required jungle clearance for survey , profile prepration of approved route on graph sheet and marking of offset on either side of line , marking of side clearance for hills , sand dunes etc . as per specification and tower scheduling . , checked survey as per approved route of line which includes: , re checklng of the line route as per approved profile , chainage , tower center marking , pit marking , bisection of angle tower as required at site . , excavation excavation , excluding back filling , including shoring , shuttering , dewatering etc up to the required depth as per foundation specification/drawings , normal soil , setting of template & stub/anchor bolt: setting of template & stub/anchor bolt & removal after concreting , excluding cost of excavation and concreting but including back filling with excavated/borrowed earth ( with lead & lift ) in layers with ramming and watering as per specifications . , 132 kv s/c tower up to +6m extension , tower including extension upto 9 meters , concreting providing and laying cement concrete for all types of foundation as per latest iss:456 including cement , sand , stone aggregate 20mm nominal size , water etc . , preparing surfaces , shuttering , mixing , placing , ramming , curing , finishing as per specification and drawings . , 1:3:6 mix , 1:2:4 mix , 1:1 . 5:3 mix , steel reinforcement , cutting , bending , welding of joints if required , fixing and placing of steel reinforcement as per specification and drawings including material , earthing earthing of towers with pipe type earthing excluding the supply of pipes , wires , flats & connectors , but including coke/charcoal , etc . , excavation , augering and backfilling in all types of soil . , erection of towers erection of super structures including d shackles , acd , hangers , u bolts , step bolts , danger plate , phase plate , number plate etc . also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of zinc rich paint , 132 kv s/c tower , erection of towers including extension upto 09 meters , conductor stringing : stringing of acsr panther including hoisting of insulator string , laying , jointing & tensioning of conductor , clamping with armour rods and fixing of vibration damper per route km of the line . , 132 kv , single conductor , earth wire stringing : stringing of galvanised steel stranded wire including laying , jointing & tensioning , clamping , clipping and fixing vibration damper and earth bond etc . , 132 kv , one no 7/3 . 15 galvanised wire , dismantling of towers: dismantling of super structures including extensions , having tag welded bolts & nuts including d shackles , hangers , u bolts , acd . danger plate , phase & number plate of tower including transportation form site t our store and stacking of all material , ( a ) 132kv and 220kv s/cand d/c all types . , destringing of conductor / earthwire: destringing of acsr panther conductor : dismantling of vibration dampers and armour rods , removal of conductor from clamps and fitting in rollers , detensioning , dehoisting of insulator string as required and collecting the material & depositing the same in our store and stacking . , single conductor , destricting of earthwire: dismantling or earth bonds , vibration dampers , declipping & fitting in rollers , detensioning and collecting the material & depositing the same in our store and stacking . , one no . 7/3 . 15 mm galvanized wire...